• Title/Summary/Keyword: In-water cleaning

Search Result 653, Processing Time 0.035 seconds

A Study on the Treatment Performance of Coalescer to Treat Exhaust Gas Cleaning Water (콜레이서를 이용한 배기가스 세정수 처리 성능에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • This study was conducted on a circulation system which can recycle waste water from EGCS(Exhaust Gas Cleaning System) using a wet scrubber that is used to treat air pollutants from ships. Though we developed a water treatment system that could remove effectively particulate matters and dispersed oil included in cleaning water for Ship Exhaust Gas Recycle System(DePM & DeSOx), we found that it is difficult to treat minutely dispersed oil only by means of centrifugal-typed purifier. Therefore, to this system, we applied a coalescer that coalesces emulsified minute oil particles in the 2nd phase of dispersion state after being filtered through the centrifugal-typed purifier. After we treated cleaning water drained out of Ship Exhaust Gas Recycle System(DePM & DeSOx) by using both purifier and coalescer, we found that particulate matters and dispersed oil were removed more than 55% and 99%, respectively, in comparison with those contained in cleaning water influent. Putting the results together, we conclude that the treated cleaning water can be recycled as normal cleaning water if this cleaning water treatment system is employed by the wet cleaning tower system for the reduction of air pollutants from ships.

Efficiency Evaluation of Wind Power Blade Surface Cleaning using Brush and Water Jet (브러시 및 워터젯을 이용한 풍력 발전 블레이드 표면 청소 효율 측정)

  • Jeon, Minseok;Kim, Byunggon;Park, Sora;Hong, Daehie
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.9
    • /
    • pp.977-982
    • /
    • 2013
  • Blades of wind energy plants are exposed to external shocks or internal cracks during operation. Furthermore, the blade surfaces can be contaminated by substances such as dust, blood of birds, salt or insects which can decrease the electricity generation efficiency significantly. For this reason, many blade cleaning companies started to appear and a variety of methods for cleaning were suggested. Despite these diverse methods, there has been no study to investigate how effectively to clean the substances in quantitative manner. In this paper, the cleaning efficiency of two rotor blade cleaning methods, brush and water-jet, is examined through experiments by changing operating parameters. Then, the optimal operating conditions for both methods are derived.

Development of Aqueous/Semi-Aqueous Cleaning Agent and its Field Application to Cleaning Process of Electronic Parts (수계/준수계 세정제의 개발 및 전자부품 세정공정 현장적용 연구)

  • Kim, Han-Seong;Cha, An-Jeong;Bae, Jae-Heum;Lee, Ha-Yeoul;Lee, Myung-Jin;Park, Byeong-Deog
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.61-72
    • /
    • 2004
  • In this study, aqueous/semi-aqueous cleaning agents which consist of organic solvent, surfactant, cosurfactant, and water were developed by changing formulation parameters such as organic solvent type and contents, surfactant type and contents, and cosurfactant/surfactant(A/S) ratio, etc.. And physical properties and flux removal of the formulated cleaning agents have been evaluated. Also, the performance of oil-water separation from the rinse water contaminated during the cleaning process was evaluated for its recycling. The formulated cleaning agents in this work expected to have good penetration because of their low viscosity and low surface tension values of 30.2~32.5 dyne/cm. The flux removal with the terpene type cleaning agent was higher than that with hydrocarbon type cleaning agent and two commercial products (CPA(commercial product A), CPB(commercial product B)). And the performance of oil-water separation by gravity settling from the rinse water contaminated with formulated cleaning agent and soils was shown to be very good. The cleaning agents developed in this work were applied to surface mounting technology(SMT) cleaning process for manufacturing electronic parts at L electronic company. As a result, the newly developed cleaning agents showed two times better cleaning speed for removal of solder cream than the conventional ond containing ethanol and IPA(isopropyl alcohol). In addition, malodor and VOC problems generated by the previous organic cleaning agents have been solved in the manufacturing field through introduction of the non-volatile and environmental-friendly cleaning agents to the field.

  • PDF

Effect of Road Sweeping on the Abatement of Runoff Pollution Loads from in the Highway (고속도로 노면 청소에 따른 강우시 유출오염부하 저감 효과 분석)

  • Kang, Heeman;Lee, Doojin;Yoon, Hunsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.851-860
    • /
    • 2012
  • In this study, to evaluate the abatement of runoff pollution loads by the road sweeping(cleaning), various investigations are implemented at the sample area of the highway. As the results of evaluating the removal efficiency of pollutants along road cleaning, TSS showed about 78 % of the removal efficiency and COD showed 49 % of removal efficiency through the operation of cleaning vehicle of vacuum suction method. In case of TN and TP, they showed the relatively-lower removal efficiency by 30~35 %. TSS removal efficiency along the number of cleaning appeared about 60 % in case of one time of cleaning and the additional removal effect did not appear though the number of cleaning increased to two times. With running speed of cleaning vehicle, TSS removal ratio is lessened from 60 % to 20 % when cleaning vehicle speed up to 20 km/hr from 6 km/hr. It seems that the reasons why the removal efficiencies are inversely proportional to its speed are related to the lower vacuum efficiencies and the disturbed particles on the road. In the pollutant build-up analysis, it is showed that it takes more time to the critical pollutant build-up in the shoulder than the center of the road. It is also showed that the proper cleaning cycle is recommended as 4~6 dry weather days without rainfall events.

A New Algorithm for Complete Coverage Path-Planning of Cleaning Robots (청소 로봇을 위한 경로 계획의 새로운 알고리즘)

  • Jiang, Liu;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.252-254
    • /
    • 2005
  • Completer coverage path planning requires the robot path to cover every part of the workspace, which is an essential issue in cleaning robots and many other robotic applications such as vacuum robots and painter robots. In this paper, a novel Water Flowing Algorithm (WFA) is proposed for cleaning robots to complete coverage path planning in unknown environment without obstacles. The robot covers the whole workspace just like that water fills up a container. First the robot goes to the lowest point in the workspace just like water flows to the bottom of the container. At last the robot will come to highest point in the workspace just like water overflows from the container and simultaneously the robot has covered the whole workspace. The computer simulation results show that the proposed algorithm enable the robot to plan complete coverage paths.

  • PDF

Fouling and cleaning protocols for forward osmosis membrane used for radioactive wastewater treatment

  • Liu, Xiaojing;Wu, Jinling;Hou, Li-an;Wang, Jianlong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.581-588
    • /
    • 2020
  • The membrane fouling is an important problem for FO applied to the radioactive wastewater treatment. The FO fouling characteristics for simulated radioactive wastewater treatment was investigated. On-line cleaning by deionized (DI) water and external cleaning by ultrasound and HCl were applied for the fouled membrane. The effectiveness and foulant removing amount by each-step cleaning were evaluated. The membrane fouling was divided into three stages. Co(II), Sr(II), Cs(I), Na(I) were all found deposited on both active and support layers of the membrane surface, resulting in membrane surface became rougher and more hydrophobic, which increased membrane resistance. On-line cleaning by DI water recovered the water flux to 69%. HCl removed more foulants than ultrasound.

A Study on Economic Evaluation and Energy Efficiency for the Installation of Water Control Device in Building (급수제어장치 설치에 따른 건축물의 에너지 효율 및 경제성 평가)

  • Park, Kang-Hyun;Cha, Jung-Hoon;Kim, Su-Min
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.338-341
    • /
    • 2011
  • Water usage for cleaning the toilet bowl accounts for 27% of the total water usage. Water-saving valve that can select the amount of water for cleaning toilet bowl can be reduced expenditure. After installing water-saving valve, analysed the economic effects. Water-saving valves compared with flush valves, and researched the amount of water usage. Then analyzed fort he economic effects. Water-saving valve was used 5.6 ${\ell}/time$ for cleaning toilet bowl. In contrast, flush valve was consumed 8.4 ${\ell}/time$. Water-saving valve's water-saving rate was 33.3%. The initial payback period for Water-saving valve was 459.5 days. By a small investment in water saving valve, the economic benefits can be obtained.

  • PDF

Development of Chemical Cleaning Agents for Cleaning Indoor Water Supply Pipes (옥내급수관 세척용 화학세정제 개발 연구)

  • Lee, Jae-Hoon;Jung, Jae-Yong;Park, Yong-Bae;Bae, Jae-Heum;Woo, Dal-Sik;Sin, Hyun-Duk
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.162-171
    • /
    • 2010
  • The objective of this study is to develop cleaning agents for the indoor water supply pipe which is environmentally friendly and suitable for removing scale by using various organic acids, inorganic acids, and some additives. Among various organic acids, oxalic acid, citric acid, and malic acid showed good cleaning efficiency of iron oxides which were main components of the indoor water supply pipe scale. Several cleaning agents were formulated by adding chemical additives into these organic acids and evaluated for removal of iron oxides. In this study, it was found that nonionic surfactants were excellent for the removal of iron oxide scale among various additives. Two types of cleaning agents($F_1$, $F_2$) with comparatively high solvent power for iron oxides were formulated in this study. The cleaning agents $F_1$ made by organic acids and some additives were formulated to be safe and environmentally friendly, but seemed to have disadvantage due to their comparatively low cleaning efficiency of iron oxide than $F_2$. But, the cleaning agents $F_2$ prepared by adding inorganic acid a little to $F_1$ showed comparatively good cleaning efficiency of iron oxide and could be recommended for removing hard scale of iron oxides in the indoor water supply pipe. Thus, it is considered that the formulated cleaning agents should be selected based on the extent of scale in the indoor water supply pipe.

Ship's Hull Fouling Management and In-Water Cleaning Techniques (선체부착생물관리와 수중제거기술)

  • Hyun, Bonggil;Jang, Pung-Guk;Shin, Kyoungsoon;Kang, Jung-Hoon;Jang, Min-Chul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.785-795
    • /
    • 2018
  • The International Maritime Organization (IMO) has recognized the risk of hull fouling and announced '2011 Guidelines for the control and management of ship's biofouling to minimize the transfer of invasive aquatic species'and is planning international regulations to enforce them in the future. In this study, to effectively respond to future international regulation, we introduce the case of leading countries related to management of hull fouling and also investigate environmental risk assessment techniques for in-water cleaning. Australia and New Zealand, the leading countries in hull fouling management, have established hull fouling regulations through biological and chemical risk assessment based on in-water cleaning scenarios. Most European countries without their government regulation have been found to perform in-water cleaning in accordance with the IMO's hull fouling regulations. In the Republic of Korea, there is no domestic law for hull fouling organisms, and only approximately 17 species of marine ecological disturbance organisms, are designated and managed under the Marine Ecosystem Law. Since in-water cleaning is accompanied by diffusion of alien species and release of chemical substances into aquatic environments, results from biological as well as chemical risk assessment are performed separately, and then evaluation of in-water cleaning permission is judged by combining these two results. Biological risk assessment created 40 codes of in-water cleaning scenarios, and calculated Risk Priority Number (RPN) scores based on key factors that affect intrusion of alien species during in-water cleaning. Chemical risk assessment was performed using the MAMPEC (Marine Antifoulant Model to Predict Environmental Concentrations), to determine PEC and PNEC values based on copper concentration released during in-water cleaning. Finally, if the PEC/PNEC ratio is >1, it means that chemical risk is high. Based on the assumption that the R/V EARDO ship performs in-water cleaning at Busan's Gamcheon Port, biological risk was estimated to be low due to the RPN value was <10,000, but the PEC/PNEC ratio was higher than 1, it was evaluated as impossible for in-water cleaning. Therefore, it will be necessary for the Republic of Korea to develop the in-water cleaning technology by referring to the case of leading countries and to establish domestic law of ship's hull fouling management, suitable for domestic harbors.

A Study on the Contamination of D.I. Water and its Effect on Semiconductor Device Manufacturing (초순수의 오염과 반도체 제조에 미치는 영향에 대한 연구)

  • Kim, Heung-Sik;Yoo, Hyung-Won;Youn Chul;Kim, Tae-Gak;Choi, Min-Sung
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.99-104
    • /
    • 1993
  • We analyzed the D.I. water used in wet cleaning process of semiconductor device manufacturing both at the D.I. water plant and at the wafer cleaning bath to detect the impurity source of D.I. water contamination. This shows that the quantity of impurity is related to the resistivity of D.I. water, and we found that the cleanliness of the wafer surface processed in D.I. water bath was affected by the degree of the ionic impurity contamination. So we evaluated the cleaning effect as different method for Fe ion, having the best adsoptivity on wafer surface. Moreover the temperature effect of the D.I. water is investigated in case of anion in order to remove the chemical residue after wet process. In addition to the control of D.I. water resistivity, chemical analysis of impurity control in D.I. water should be included and a suitable cleaning an drinsing method needs to be investigated for a high yielding semiconductor device.

  • PDF