• Title/Summary/Keyword: In-water cleaning

Search Result 648, Processing Time 0.027 seconds

The Development Measuring System of Temperature Effect to Produce Electric Power of Solar Cell

  • Sadmai, Ong-art
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.104-113
    • /
    • 2015
  • This paper focuses on a temperature effects on a PV panel which has been installed in Thailand. The main objective is cleaning PV panels and reduce temperature of PV panel by water injects from waterway and experimental results of PV power what it is difference. This project is designed by PLC control system which water injects and control PV temperature, In addition, this project consists of hardware and software such as water pump, water injection and PLC control has been automatically and it can be control system manually. The automatic control system is working when PV temperature rises up over 45 degree Celsius after that the pumping machine would inject water to the surface of PV panels and it must be stop when the PV panel temperature comes down less than 45 degree Celsius. The result of actual experimental found that the control system has been done correctly under specify condition. The experimental has been shown electrical data before and after water injects on PV system found that the electrical power a bit increases and The energy has been taken from PV panel less than energy consumption equipment of control system which taken to operate the water injecting system.

A study about treatment for water treatment residual sludge using submerged membrane system (침지식 막여과 공정을 이용한 정수장 배출수 처리에 관한 연구)

  • Kim, Jun-Hyun;Lee, Ju-Hyung;Moon, Baek-Su;Kwak, Young-Ju;Jang, Jung Woo;Kim, Jinho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.2
    • /
    • pp.181-193
    • /
    • 2014
  • Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.

Effect of Seed Imbibition into Water and Acetic Acid Solution on its Floating Rate and Growth of Soybean Sprouts (수침(水浸)과 Acetic Acid 처리에 따른 콩나물의 생장과 형태 변화)

  • Jeon Byong-Sam;Hong Dong-Oh;Kim Hong-Young;Lee Chang-Woo;Kang Jin-Ho
    • Korean Journal of Plant Resources
    • /
    • v.19 no.2
    • /
    • pp.204-208
    • /
    • 2006
  • Soybean sprout decay during its culture should be one of serious problems. The study was carried out to clarify the effect of water imbibition and acetic acid treatments on growth and morphological characters of the soybean sprouts. The soybean seeds of 3 cultivars (cv. Eunhakong, Pungsannamulkong and Junjery) imbibed in pure water or 0.l% acetic acid for 3 minutes before soaked for 6 hours into 1 ppm BA solution and aerated for 3 hours immediately before 6 day culture. On the 6th day, the sprouts were classified into 4 categories on the base of hypocotyl length; > 7cm, 4 to 7cm, > 4cm and not germinated and seed floating rate, their morphological characters, fresh fraction weights and productivity were measured. The best water imbibition for seed cleaning was to soak the seeds for 5 minutes and then to aerate soak them for 40 minutes. In Pungsannamulkong and Junjery, percentage of the sprouts with hypocotyls of longer than 4 cm was higher in water imbibition than in acetic acid treatment for seed disinfection although in Eunhakong there was no significant difference between the two treatments. Eunhakong and Junjery had greater lateral root formation rate and its number per sprout in water imbibition than in acetic acid treatment but Pungsannamulkong showed reverse result. Eunhakong and Pungsannamulkong, furthermore, had more total fresh weight in acetic acid treatment than in water imbibition but Junjery showed reverse result, although there was no significant difference between the two treatments in productivity of mass production system.

Investigating coating material and conditions for rehabilitation of water transmission pipe using a robotic system (자동화 장비를 이용한 대형 상수관로 갱생을 위한 코팅재료 선정 및 방법에 관한 연구)

  • kim, Jinwon;Kim, Donghyun;Lee, Younggun;Lee, Sewan;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.725-736
    • /
    • 2016
  • There is a growing concern on the improvement of water distribution pipeline for multi-regional water supply system in Korea along with its aging infrastructure. Rehabilitation of large diameter pipeline is more efficient in cost and time compared to replacement with trenching. The procedure for rehabilitation are diagnosis, cleaning, spraying coating material, and final inspection. The internal state of pipeline was carefully diagnosed and got C grade, which required rehabilitation. We found that 17,274,787,000 Korean won could be saved after pipe surface coating because of increased C coefficient of Hazen-Williams equation. Optimal coating material was D polyurea. We also found optimal distance between spraying nozzle and pipe wall to be 70 - 80 cm, which were critical factors for coating quality. This study also illustrated the time for spray drying to be more than 30 min. These results could be used in the quality control process during rehabilitation of aged pipelines.

The Solubility of Ozone in Deionized Water and its Cleaning Efficiency (초순수내에서의 오존의 용해도와 세정효과)

  • Han, Jeoung-Hoon;Park, Jin-Goo;Kwak, Young-Shin
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.532-537
    • /
    • 1998
  • The purpose of this study was to investigate the behavior of ozone in DI water and the reaction with wafers during the semiconductor wet cleaning process. The solubility of ozone in DI water was not only dependent on the temperature but also directly proportional to the input concentration of ozone. The lower the initial ozone concentration and the temperature, the longer the half-life time of ozone. The reaction order of ozone in DI water was calculated to be around 1.5. The redox potential reached a saturation value in 5min and slightly increased as the input ozone concentrations increased. The completely hydrophilic surface was created in Imin when HF etched silicon wafer was cleaned in ozonized DI water containing higher ozone concentrations than 2ppm. Spectroscopic ellipsometry measurements showed that the chemical oxide formed by ozonized DI water was measured to be thicker than that by piranha solution. The wafers contaminated with a non-ionic surfactant were more effectively cleaned in ozonized DI water than in piranha and ozonized piranha solutions.

  • PDF

EXPLOSION HAZARDS IN TANKS OF HIGH FLASH POINT LIQUIDS

  • Zalosh, Robert
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.203-210
    • /
    • 1997
  • Reports of explosions in cargo and storage tanks of high flash point liquids such as residual fuel oil, asphalt, and oily waste water have shown that these explosions have occurred even when the liquid temperatures are well below the liquid nominal flash point. The reasons for these seemingly paradoxical explosions are reviewed and results of recent laboratory tests are presented to better define the conditions leading to flammable vapor atmospheres in these tanks. The potential effectiveness of various prevention measures are discussed including inerting, monitoring tank vapor concentrations, and periodic cleaning of condensation and deposits on the tank walls and roof.

  • PDF

Evaluation and modelling of the separation of anthracite in the hindered-settling column

  • Kim, Jeong-Yun;Cho, Hee-Chan
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.611-617
    • /
    • 2003
  • This study was performed to develop the method for producing industrial coal sources by cleaning Korean anthracite. Laboratory hindered-settling separation column was set and three coal samples were used for tests. Tests were conducted to evaluate the effects of the major operating variables, teeter water flow rate and relative column pressure (set point). Additional tests were performed to elevate the yield and properties of the products using air bubble injecting process. In results, nice products were obtained with high teeter water flow rate and air bubble injection. Also, model of continuous hindered-settling separation process was established to assist the evaluation of the equipment and several operating variables, such as dispersion, teeter water flow rate, feeding rate, etc.

  • PDF

A Study on the maintenance situation of the deteriorted high-rise apartments (노후 고츨아파트의 유지관리 및 개선실태 조사)

  • 주서령;이미정
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.75-83
    • /
    • 2001
  • The deteriorted high-rise apartments make a social problem in now days. As a result, and new alternative plan for deteriorted high-rise apartments such as the remodeling concept must be considered. This study aims to develop the remodeling items which is the guide lines when remodeling of the apartment will be conducted. Thorough the case studies of maintenance and repair status of the deteriorted apartments in seoul, reasonable guidelines for selection of remodeling items were developed. Physical maintenance items includes those that need major repair activity like wall painting, water proof roof, change/repairs/implement of heating system, boiler, city gas pipelines, cold and hot water pipes, elevators, cleaning of water tanks. The period of repair is shorter than the durable year of law or codes. As a result of the study, basic maintenance items and actual repair period were proposed. This result will be the basic guidelines for remodeling items.

  • PDF

A Research Study on Work-Man′s Uniform(2) (직장 남성들의 근무복 실태조사 연구(2) -근무복 착용도와 관리도를 중심으로-)

  • 서미아;박선희
    • The Research Journal of the Costume Culture
    • /
    • v.4 no.3
    • /
    • pp.337-347
    • /
    • 1996
  • The work-man's Uniform should be coincident with the image of his firm and accounted of the function according s its purpose. We made questions to 404 workers at 8firm in our country through the questionnaire papers to know about a work-man's uniform and researched whether the satisfactory in wearing his uniform had relation with his type of business, grade, carrier, age, marriage, and monthly income. The results of this study is as follows; 1. In the case of wearing the uniform many workers answered they always wore their uniform in the firm. It was shown that the office workers wore their uniform much more than workers in the production department. The longer the time working, the older age, the lower grade of school career are, he more workers wear. the order of the importance for he uniform was the function, the symbol, the originality, and the fashion. The longer their career in the firm was, the more important the function of their uniform was. 2. The order of dirty pat in taking care of the uniform was cuffs, color, the front of part in an upper garment and below the knee, the hip in pants It was very easy for the workers in the experts, or administrators and office workers than others to be dirty in the cuffs part of the uniform. Worn part of the uniform showed highest cuffs in an upper garment and a zipper in pants. The order of cleaning the uniform was washing by water, no ironing, and cleaning in their house.

  • PDF

Comparition of Submerged / Pressurized Type Membrane System by DRF and Long-Term Results in MF Drinking Water Treatment (MF막여과 정수처리에서 장기운전 결과 및 DRF를 이용한 침지식 / 가압식 시스템의 비교 평가)

  • Ha, Keum Ryul;Kim, Kwan Yeop;Kim, Hyo-Sang;Lee, Yong Soo;Song, June Sup;Kim, Chung Hwan;Yeom, Ick Tae;Lee, Yong Hoon;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • In Korea, most of the drinking water treatment relied upon the availability of the surface water, of which the raw water quality varied significantly by season and location. Therefore, the comparison of two operation modes (Pressurized type and Submerged type membrane system) must be estimated before the long-term establishment of two systems. In this study, two pilot-scale microfiltration systems with the capacity of $50m^3/day$ were installed and operated in two different modes, and the applicability of the system was determined based on the results such as the TMP (Trans-Membrane Pressure) and flux. For quantitatively comparing the two systems, a new concept, DRF (Differential Resistance Fraction) was introduced. The accumulated sum of the permeate after each cycle of chemical cleaning was also used as a tool for the system comparison.