• 제목/요약/키워드: In-vitro Blood Flow

검색결과 148건 처리시간 0.026초

미세튜브 내부를 흐르는 혈액유동의 유변학적 특성에 대한 in-vitro 연구 (In-vitro Study on Hemorheological Behaviors of Blood Flow Through a Micro Tube)

  • 강명진;지호성
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.99-105
    • /
    • 2010
  • In order to obtain velocity profile of blood flow with high spatial resolution, a micro PIV technique consisted of a fluorescent microscope, double-pulsed YAG laser, cooled CCD camera was applied to in-vitro blood flow experiment through a micro round tube of a diameter $100{\mu}m$. Velocity distributions of blood flow for rabbit were obtained. The viscosity profiles for shear rate were found at flowing condition. To provide hemorheological characteristics of blood flow, the viscosities for shear rate were evaluated. The viscosity of blood also steeply increase by decreasing shear rate resulting in Non-Newtonian flow, especially in low shear rate region caused by RBC rheological properties. The results show typical characteristics of Non-Newtonian characteristics from the results of velocity profile and viscosity for blood flow. From the inflection points, cell free layer and two-phase flow consisted with plasma and suspensions including RBCs can be separated.

이중 분지관내 혈액 및 혈액대용유체의 3차원 유동해석 (3-D Flow Analysis of Blood and Blood Substitutes in a Double Branching Model)

  • 서상호;유상신;노형운
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권2호
    • /
    • pp.187-196
    • /
    • 1997
  • The three-dimensional flow analysis using the finite volume method is presented to compare the steady flow characteristics of blood with those of blood substitutes such as water and aqueous polymer solution in an idealized double branching model. The model is used to simlllate the region of the abdominal aorta near the celiac and superior mesenteric branches. Apparent viscosities of blood and the aqueous Separan solution are represented as a function of shear rate by the Carreau model, Water and aqueoiu Separan AP-273 500wppm solution are frequently used as blood substitutes in vitro experiments. Water is a typical Newtonian fluid and blood and Separan solution are non-Newtonian fluids. Flow phenomena such as velocity distribution, pressure variation and wall shear stress distribution of water, blood and polymer solution are quite different due to differences of the rheological characteristics of fluids. Flow phenomena of polymer solution are qualitatively similar to those of blood but the phenomena of water are quite different from those of blood and polymer solution. It is recommended that a lion-Newtonian fluid which exhibits very similar rheological behavior to blood be used in vitro experiments. A non-Newtonian fluid whose rheological characteristics are very similar to those of blood should be used to obtain the meaninylll hemodynamic data for blood flow in vitro experiment and by numerical analysis

  • PDF

CFD해석을 이용한 축류형 혈액펌프의 용혈평가 및 형상개량에 관한 기초연구 (A Study on Shape Optimization and Hemolysis Evaluation of Axial Flow Blood Pump by Using Computational Fluid Dynamics Analysis)

  • 김동욱;임상필
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권1호
    • /
    • pp.57-64
    • /
    • 2004
  • 최근 심장질환에 의한 사망자 수는 놀랄 만큼 빠른 증가세를 보이고 있다. 인공심장은 혈액의 흐름에 따라 크게 박동류형과 무박동류형으로 나뉘며, 무박동류형 펌프는 비용적형으로 박동류형에 비해 소형화가 가능하다는 장점을 가지고 있다. 이러한 무박동류형 혈액펌프는 다시 구동방식에 따라 축류형과 원심형으로 구분되어지며, 그중 축류형 혈액펌프는 같은 무박동류형인 원심형 혈액펌프와 비교하였을 때 훨씬 간단한 구동장치와 제어장치를 가진다. 혈구가 파괴되어 헤모글로빈이 혈구 밖으로 빠져나가는 것을 용혈이라 하며 혈액이 응고하여 혈관을 막게되는 혈전현상은 이러한 용혈이 주된 원인이다. 따라서 혈액펌프가 구동함에 따라 발생하게 되는 용혈의 수치를 낮추는 것은 혈액펌프를 개발하는데 있어서 중요한 조건 중에 하나이다 이러한 용혈을 평가하기 위한 방법으로는 현재 in-vitro실험이 가장 널리 사용되어지고 있으나, 이러한 체외실험을 하기 위해선 상당한 비용과 장기간의 연구기간이 요구되어진다. 이러한 in-vitro실험의 단 전을 보완하기 위해 개발되어진 CFD해석법은, 엔지니어로 하여금 in-vitro실험을 실시하지 않고 용혈이 발생하는 지역과 용혈발생예측치를 추정할 수 있다. 본 연구의 목적은 in-vitro실험의 결과데이터와 CFD해석의 예측결과데이터의 여러 가지 비교를 통해 CFD해석의 정확성을 검증하고, 또한 이러한 정확성이 검증된 CFD해석법을 현재 개발되어지고 있는 축류형 혈액펌프의 개발단계에 적용하기 위함이다.

헤마토크릿에 따른 혈액의 유변학적 특성 변화 (Effect of hematocrit on hemorheological characteristics of blood flow in a microtube)

  • 지호성;이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2006
  • In order to investigate flow characteristics of blood flow in a micro tube ($100{\mu}m$ in diameter) according to hematocrit, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, a 2 head Nd:YAG laser, a 12 bit cooled CCD camera and a delay generator. Blood was supplied into the micro tube using a syringe pump. Hematocrit of blood was controlled to be 20%, 30% and 40%. The blood flow has a cell free layer near the tube wall and its thickness was changed with increasing the flow rate and hematocrit. The hemorheological characteristics such as shear rate and viscosity were evaluated using the velocity field data measured. As the flow rate increased, the blunt velocity profile in the tube center was sharpened. The viscosity of blood was rapidly increased with decreasing shear rate, especially in the region of low shear rate, changing RBC rheological properties. The variation of velocity profile and blood viscosity shows typical characteristics of Non-Newtonian fluids. On the basis of inflection points, the cell free layer and two-phase flow consisting of plasma and suspensions including RBCs were clearly discriminated.

  • PDF

전산유체해석을 이용한 축류형 혈액펌프의 용혈평가 (Evalution of Hemolysis in Axial Flow Blood Pump with Computational Fluid Dynamics Analysis)

  • 임상필;김동욱
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.256-259
    • /
    • 2003
  • Artificial heart is divided pulsation style and nonpulsation style greatly according to flowing of blood. nonpulsation pump is advantage of miniaturization avaliable because it is simple and non-volumic-pump than pulsation pump. Non pulsation pump is derided axial flow style and centrifugal style accordig to rotating style. An axial flow blood pump can be made smaller than a centrifugal blood pump because of its higher specific speed. A hemolysis is an important factor for the development of an axial flow blood pump. It is difficult to identify the areas where hemolysis nun. Evaluation of hemolysis both in in vitro and in vivo require a long time and are costly. Computational fluid dynamics(CFD) analysis enables the engineer to predict hemolysis on a computer. The aims of this study is Computational fluid dynamics in the whole axial flow pump and to verify the accuracy of prediction results of CFD analysis compare with in vitro experimental results.

  • PDF

Ethyl Acetate Extract from Tissue-Cultured Mountain Ginseng Adventitious Roots Inhibits In Vitro Platelet Aggregation in Whole Human Blood and Augments Peripheral Blood Flow in Mice

  • Lee, In-Sun;Kim, Seul-Ki;Jeon, Min-Hwa;Jeon, Won-Kyung
    • Journal of Ginseng Research
    • /
    • 제35권4호
    • /
    • pp.442-448
    • /
    • 2011
  • We previously reported that in vitro anti-platelet activity of tissue-cultured mountain ginseng (TCMG) ethanol extracts show improved efficacy when compared with commercial ginseng products such as Korean red ginseng and Panax ginseng. However, information on the anti-platelet activity of the ethyl acetate fraction from TCMG adventitious roots is limited. Therefore, in this study, we further investigated the effects of an ethyl acetate extract of TCMG (EA-TCMG) adventitious roots on in vitro antiplatelet activity in whole human blood and its effect on peripheral blood flow in mice. We found that EA-TCMG inhibited platelet aggregation with $IC_{50}$ values of 271, 180, and 147 ${\mu}g$/mL induced by collagen, adenosine-5'-diphosphate, and arachidonic acid, respectively. Among the three agonists used, thromboxane $A_2$ formation induced by arachidonic acid was markedly suppressed. Furthermore, EA-TCMG improved the peripheral circulatory disturbance by improving vascular blood flow. In conclusion, these results suggest that ethyl acetate extracts from TCMG adventitious roots might inhibit vascular platelet aggregation and thrombus formation.

Micro-PIV Measurements of In Vitro Blood Flow in a Micro-Channel

  • Park, Cheol-Woo;Lee, Sang-Joon;Shin, Se-Hyun
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권2호
    • /
    • pp.30-35
    • /
    • 2003
  • Flow characteristics of blood flow in a micro channel were investigated experimentally using a micro-PIV (Particle Image Velocimetry) velocity field measurement technique. The main objective of this study was to understand the real blood flow in micron-sized blood vessels. The Reynolds number based on the hydraulic diameter of micro-channel for deionized (DI) water was about Re=0.34. For each experimental condition, 100 instantaneous velocity fields were captured and ensemble-averaged to get the spatial distributions of mean velocity. In addition, the motion of RBC (Red Blood Cell) was visualized with a high-speed CCD camera. The captured flow images of nano-scale fluorescent tracer particles in DI water were clear and gave good velocity tracking-ability. However, there were substantial velocity variations in the central region of real blood flow in a micro-channel due to the presence of red blood cells.

  • PDF

Robust Ultrasound Multigate Blood Volume Flow Estimation

  • Zhang, Yi;Li, Jinkai;Liu, Xin;Liu, Dong Chyuan
    • Journal of Information Processing Systems
    • /
    • 제15권4호
    • /
    • pp.820-832
    • /
    • 2019
  • Estimation of accurate blood volume flow in ultrasound Doppler blood flow spectrograms is extremely important for clinical diagnostic purposes. Blood volume flow measurements require the assessment of both the velocity distribution and the cross-sectional area of the vessel. Unfortunately, the existing volume flow estimation algorithms by ultrasound lack the velocity space distribution information in cross-sections of a vessel and have the problems of low accuracy and poor stability. In this paper, a new robust ultrasound volume flow estimation method based on multigate (RMG) is proposed and the multigate technology provides detail information on the local velocity distribution. In this method, an accurate double iterative flow velocity estimation algorithm (DIV) is used to estimate the mean velocity and it has been tested on in vivo data from carotid. The results from experiments indicate a mean standard deviation of less than 6% in flow velocities when estimated for a range of SNR levels. The RMG method is validated in a custom-designed experimental setup, Doppler phantom and imitation blood flow control system. In vitro experimental results show that the mean error of the RMG algorithm is 4.81%. Low errors in blood volume flow estimation make the prospect of using the RMG algorithm for real-time blood volume flow estimation possible.

심장내 이식형 축류 혈액펌프 용혈특성에 관한 연구 (A Study on Hemolysis Characteristics of Intra-Cardiac Axial Flow Blood Pump)

  • 김동욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.353-362
    • /
    • 2000
  • 축류형 혈액펌프에서 발생하는 용혈이 이 펌프의 성공여부를 결정짓는 주요한 요인의 하나이다. 지금까지는 용혈을 알아내기 위해서는 in-vitro 적인 실험에 의하여 용혈량을 추정하였으나, 수치유체해석에 의한 용혈량의 추정이 가능하다고 생각된다. 따라서, 본 연구에서는 다양한 형태의 임펠러에 대하여, 난류모델은 k-$\varepsilon$모델을 사용하여 3차원 수치유체역학 해석을 시도하였다. 수치유체해석에 있어서는 펌프 유입측에 입자를 흘려 넣어 이 입자가 매일 10ms마다 받는 난류에너지를 구하여 전단응력으로 환산하였다. 해석결과 전단응력은 주로 임펠러의 후방에서 나타나는 것을 알 수 있었다. 수치유체해석결과의 신뢰성을 확인하기 위하여 임펠러의 in-vitro 실험에 의한 용혈시험 결과를 비교하였으나, 양자 사이에 상관도는 높은 것을 알 수 있었다. 상기한바와 같이 유체 해석에 의한 용혈 예측은 물론 용혈이 발생하는 주요 부위의 예측이 가능함을 시사하고 있어, 축류형 혈액펌프 개발시 용혈 특성 개선을 위한 설계도구로써의 유용함을 확인하였다.

  • PDF

마이크로 PIV를 이용한 미세튜브 내부 조류 혈액유동에 관한 실험적 연구 (Experimental Investigation on Flow Characteristics of Chicken Blood in a Micro Tube Using a Micro-PIV Technique)

  • 여창섭;지호성;이상준
    • 대한기계학회논문집B
    • /
    • 제30권11호
    • /
    • pp.1027-1034
    • /
    • 2006
  • In order to investigate flow characteristics of chicken blood in a micro tube of 100$\mu$m in diameter, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, 2-head Nd:YAG laser, 12 bit cooled CCD camera and a delay generator. Chicken blood with 40% hematocrit was supplied into a micro tube using a syringe pump. The blood flow shows clearly the cell free layer near the tube wall and its thickness is increased with increasing the flow speed. The hemorheological characteristics of chicken blood, including shear rate and shear stress were estimated from the PIV velocity field data obtained. Since the aggregation index of chicken blood is less than 50% of human blood, non-Newtonian flow characteristics of chicken blood are smaller than those of human blood. As the flow rate increases, the degree of flatness in the velocity profile at the center region is decreased and the parabola-shaped shear stress distribution becomes to have a linear profile. Under the same flow rate, chicken blood shows higher shear stress, compared with human blood.