• Title/Summary/Keyword: In-tube

Search Result 10,271, Processing Time 0.052 seconds

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF

Aideo-Assisted Thoracic Surgery in Pleural Adhesion (늑막유착을 동반한 질환에서의 비디오 흉부수술)

  • Seong, Suk-Hwan;Kim, Hyeon-Jo;Lee, Chang-Ha;Kim, Ju-Hyeon
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.916-922
    • /
    • 1996
  • In patients with pleural adhesion, video-assisted thoracic surgery (VATS) has been regarded as a contra- indication. When such adhesions were found during a thoracoscopic trial, the thoracotomy proceeded with for fear of parenchymal Injury and bleeding. We had a question whether or not thoracoscopic surgery should be done in such pleural adhesions. Of the 226 consecutive thoracoscopic surgeries from Jul. 1992 through Sep. 1995, pleural adhesions were detected intraoperatively in 50 cases (22.1%): a detailed breakdown is as follows: pneumothorax (16 cases), pleural disease (15), benign pulmonary nodule(7), mediastinal mass(5), hyperhidrosis (2), diffuse parenchymal or interstitial lung disease (2), bronchiectasis(2), and primary lung cancer(1). We classified pleural adhesions according to their extent and severity. Extent is categorized as the involved area of the lung: degree 1, II, or III; severity is given one of four grades: mild, moderate, severe, or ve y severe. In cases of very severe severity requiring decortication, the possibility of VATS was excluded. Of the 50 cases, mild adhesions were detected in 15 cases(30.0%), moderate in 29 (58.0%), and severe in 6 (12.0%). As for the extent of the adhesions, 8 cases (16.0%) were categorized as degree 1, 32 cases (64. 0%) as degree II, and 10 cases (20.0%) as degree III. For patients with pleural adhesions, the operation time, the chest tube indwelling time, and the postoperative hospital stay were all longer than for patients in the non-adhesion group. Postoperative complications, namely prolonged air-leakage and pleural drain- age, were more common (18.0% and 6.0%, respectively) than in the non-adhesion group (5.1% and 1.7%, respectively). Only two bronchiectatic patients (4%) were converted to an open thoracotomy because of in- ability to control bleeding. Although complications were encountered more frequently in the group with adhesions, patients were still able to enjoy the benefi s of thoracoscopic surgery. It is advisable to proceed with thoracoscopic surgery even in cases of unpredicted pleural adhesions.

  • PDF

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Isolation of Pea and Soybean Nodule Bacteria and Assessment of their Nitrogen-fixing Capacities (완두 및 대두근류균(根瘤菌)의 분리(分離) 및 질소고정능력(窒素固定能力)의 비교(比較))

  • Kim, Seung-Yeol;Choi, Woo-Young
    • Korean Journal of Agricultural Science
    • /
    • v.5 no.2
    • /
    • pp.136-144
    • /
    • 1978
  • A series of experiments over three years was planned for practical application of rhizobia in farms and grass lands in Korea. This is the report for the studies of the first year mainly on the isolation and characterization of rhizobial strains, and on the assessment of their nodulation abilities and nitrogen fixation capacities. 1. Total number of 88 strains for soybean group and 22 st ra ins for pea and vetch group was isolated from nodules which were taken from legumes grown in Daekwanyong, Cheju and various places in Korea. 2. Morphological and cultural characteristics of the strains were studied, and attempts were also made to investigate their antigenic properties and to demonstrate lysogenic strains in these groups. The results were : i) the isolates varied in cultural characteristics on yeast mannitol broth and agar, and in degree of congo reel absorption ; ii) similarities in their antigenic properties were found between/among the strains: G-3/G-9/D216, G-20/G-52 in soybean group; iii) no lysogeny was found in the strains of these groups. 3. Plant infection tests by test tube and bottle method in light room were carried out to elucidate the ability of the strains to nodulate specific legumes and of the capacity of such nodules to fix atmospheric nitrogen. The isolates were grouped into non- invasive, ineffective, or effective to the legumes. Those strains which produced effective nodules, supporting similar level of growth as nitrate control, were: P-3, 4 and 8 in pea and vetch group; G-23, 27, and, D-216 in soybean group.

  • PDF

Tracheal Reconstruction with Perichondrial Graft - An Experimental Study in Rabbits - (연골피막편 이식후 기관 결손부위의 재생에 관한 실험적 연구(제 1 보))

  • 이원상;서장수;이성은;홍원표;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.10.3-11
    • /
    • 1982
  • Recently through the advancement of medical and surgical managements and the development of low pressure cuffed endotracheal tube, incidence of tracheal stenosis was decreased significantly. Though its incidence was decreased markedly, stenosis was developted unfortunately in the situations such as long term use of respirator, heavy infection, trauma of the trachea and long term intubation etc. Tracheal stenosis had been handled with various methods such as mechanical dilatation, tissue graft techniques, luminal augumentation and end to end anastomosis due to their individual advantages but their effects were not satisfactory. In 1959 Lester had been found the regenerated cartilage from the perichondrium of the rib incidentaly. Since then Skoog, Sohn and Ohlsen were reported chondrogenic potential of perichondrium through the animal experiments. Though many different materials have been tried to rebuild stenosis and gaping defect of trachea, tracheal reconstruction has been a perplexing clinical problems. We choose the perichondrium as the graft material because cartilage is the normal supporting matrix of that structure and it will be an obvious advantage to be able to position perichondrium over a defect and obtain new cartilage there. The young rabbits, which were selected as our experimental animals, were sacrified from two to eight weeks after surgery. The results of our experiment were as follows; 1) In control group, the defect site of trachea was covered with fibrosis and vessels but graft site was covered with hypertrophied perichondrium and vessels. 2) Respiratory mucosa was completely regenerated in defect sites both control and grafted groups. 3) The histologic changes of the grafted sites were as follows: 2 weeks- microvessel dilatation, inflammatory reaction, initiation of fibrosis 4 weeks- decreased microvessel engorgement, submucosal fibrosis, decreased inflammatory reaction immatured cartilage island was noted in the grafted perichondrium (one specimen) 6 weeks- mild degree vascular engorgement submucosal fibrosis. chronic inflamatory reaction cartilage island and endochondrial ossification was noted in the grafted perichondrium (Two specimens) 8 weeks- minute vascular engorgement dense submucosal fibrosis. loss of inflammatory reaction. cartilage island was noted in the grafted perichondrium (two specimens) 4) There was no significant differences in regeneration between active surface in and out groups. 5) We observed immatured cartilage islands and endochondrial ossification in the perichondrial grafted groups where as such findings were not noted in control groups except fibrosis. We concluded that perichondrium was the adequate material for the reconstruction of defected trachea but our results was not sufficient in the aspect of chondrogenic potential of perichondrium. So further research has indicated possibility of chondrogenic potential of perichondrium.

  • PDF

The effectiveness of urokinase in treatment of pleural effusion in children (소아의 흉수 치료에 있어서 유로키나제 효과)

  • Nam, Ga-yeon;Park, Hee-ju
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.7
    • /
    • pp.660-664
    • /
    • 2007
  • Purpose : Pleural effusion is a common complications of pediatric bacterial pneumonia. Intrapleural administration of fibrinolytic agents such as urokinase have been used in the management of complicated parapneumonic effusions. But the safety and effectiveness of intrapleural urokinase instillations in children has not been confirmed. The aim of this study is to evaluate the safety and effectiveness of intraperitoneal urokinase in children. Methods : We reviewed a total of 29 children diagnosed as parapneumonic effusion with septation by chest CT or chest ultrasonography. We divided them into two groups. Fourteen children treated with urokinase after thoracostomy (Group A) were compared with 15 children treated only with thoracostomy (Group B). The urokinase, 3,000 IU/kg/day, was injected into the pleural cavity twice a day. Results : There was no statistical difference in sex and age between the two groups. Total drainage volume during thoracostomy in group A and B was 375.5 mL and 350.0 mL, respectively. It was not statistically significant. But the amounts of pleural fluid of group A on day 1, day 2 and day 3 were 102.5 mL, 100.0 mL, and 70.0 mL respectively and those of group B on day 1, day 2 and say 3 were 120.0 mL, 50.0 mL and 15.0 mL respectively. To compare group A with group B in the amounts of drainage volume on day 1 was not statistically significant, but the amounts of drainage volumes on day 2 and day 3 in group A were statistically more significant than group B (Day 1 P=0.371, Day 2 P=0.049, Day 3 P=0.048, respectively). The duration of fever, antibiotics, thoracostomy and total hospital days. Were not statistically significant between the two groups. But the frequency of complications in Group A was statictically significantly lower than in group B. Conclusion : Intrapleural instillation of urokinase facilitates the drainage of loculated pleural effusions, especially during the first 3 days, and it could reduce complications, such as pleural thickening, surgical managements, re-positioning of tube and re-thoracostomy. So intrapleural urokinase injection was and effective and safe treatment of pleural effusion in children (P=0.014).

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

ANTIMICROBIAL EFFECT OF ANTIBIOTICS AND ROOT CANAL CEMENTS ON THE PREDOMINANT PATHOGENIC ANAEROBIC MICROFLORA IN ROOT CANALS (근관내 주요 혐기성 병인균에 대한 수종 항생제와 근관충전용 세멘트의 항균효과에 관한 연구)

  • Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.515-525
    • /
    • 1993
  • The purpose of this study was to evaluate the susceptibility of anaerobic microorganisms to certain antibiotics and root canal cements. Prevotella intermedia(Bacteroides intermedius) ATCC 25611(serotype A), Fusobacterium nucleatum ATCC 25586, Actinomyces viscosus ATCC 15987 which are the predominant pathogenic anaerobes in dental root canals were cultured in BHI for 48 hours(Fig.1). After each $200{\mu}l$ of those broths with microorganisms was streaked on each surface of blood agar plate, 2 to 5 antibiotic discs which are impregnated with Tetrncycline, Erythromycin, Ampicillin, Clindamycin, or Vancomycin were applied on each surface of blood agar plate and cultured for 5 days anaerobically in the anaerobic chamber (Fig.2). 15 antibiotic discs for each kind of antibiotics and each species of microorganisms were tested. Also each kind of root canal cement tubes which include Zinc oxide eugenol cement, Zinc phosphate cement, Calcium hydroxide powder+DD.W., Calcium hydroxide paste(Pulpdent Tempcanal), or Vitapex(Table 1) were applied on the inoculated BAPs after $200{\mu}l$ of each experimental species of microorganisms was streaked on the surface of blood agar plates, and they were cultured for 5 days anaerobically in the anaerobic chamber(Fig.3). The sensitivity(antimicrobial effect) was determined by the diameter of the inhibition zone. The results are as follows: 1. The results of antibiotic susceptibility test(Table 2) 1) All of the tested antibiotics had antimicrobial activity with various degrees. 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Erythromycin($37.87mm{\pm}2.20$) was largest, those to Tetracycline($26.20mm{\pm}2.96$), Vancomycin($21.53mm{\pm}1.96$), Clindamycin($18.73mm{\pm}0.96$) was smaller than former orderly, and That to Ampicillin ($7.87mm{\pm}0.83$) was smallest. 3) In Actinomyces viscosus, the diameter of inhibition zone to Erythromycin($28.73mm{\pm}1.22$) was largest, those to Ampicillin($21.73mm{\pm}1.03$), Clindamycin($21.33mm{\pm}1.59$) was similarly next order, that to Vancomycin($19.00mm{\pm}1.96$) was smaller than Clindamycin, and that to Tetracycline($11.93mm{\pm}0.70$) was smallest. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Ampicillin($31.07mm{\pm}1.91$) was largest, that to Erythromycin($28.87mm{\pm}0.92$), Clindamycin($20.47mm{\pm}1.51$), Vancomycin ($16.73mm{\pm}0.96$), Tetracycline ($12.13mm{\pm}1.06$) are smaller than former orderly. 2. The results of root canal cements and pastes(Table 3) 1) The external diameter of tube is 4mm, so 4mm of the inhibition zone diameter means non-susceptable. Prevotella intermedia (old Bacteroides intermedius) was non-susceptable to Calcium hydroxide powder+D.D.W., Calcium hydroxide paste(pulpdent Tempcanal), and Actinomyces viscosus was non-susceptable to Zinc phosphate cement, Calcium hydroxide powder + D.D.W., Calcium hydroxide paste(pulpdent Tempcanal). 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Zinc oxide eugenol cement($13.67mm{\pm}3.30$) was largest, that to Vitapex($9.20mm{\pm}2.96$), Zinc phosphate cement($6.13mm{\pm}2.07$) was smaller than former. 3) In Actinomyces viscosus, the diameter of inhibition zone to Zinc oxide eugenol cement($17.40mm{\pm}5.20$) was largest and that to Vitapex($8.80mm{\pm}1.70$) was next order. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Vitapex($42.33mm{\pm}17.2$) was largest and those to Calcium hydroxide paste(Pulpdent Tempcanal)($14.47mm{\pm}3.72$) and Zinc oxide eugenol cement($8.93mm{\pm}2.71$), Zinc phosphate cement($8.20mm{\pm}2.27$), Calcium hydroxide powder+D.D.W.($5.53mm{\pm}2.10$)was next orderly. And then In Zinc oxide eugenol cement and Zinc phosphate cement group, two of fifteen samples showed no inhibition zone, in Calcium hydroxide powder + D.D.W. group, 8 of 15 samples showed no inhibition zone.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

In Vitro imaging of MRI and Ultrasound for Colorectal Carcinoma (직결장암 조직의 자기공명영상과 초음파 소견에 대한 비교 연구)

  • Lee, Hwang Kyu;Jee, Keum Nahn;Hong, Sujin;Koh, Jae Hyang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Purpose : To evaluate and compare the accuracy of magnetic resonance imaging (MRI) and ultrasound (US) for detection and estimation of invasion depth of colorectal carcinoma (CRC) by correlation with histopathologic findings in vitro, and to find out the best MR pulse sequence for accurate delineation of tumor from surrounding normal tissue. Materials and Methods: Resected specimens of CRC from 45 patients were examined about tumor detectability and invasion depth of US using high frequency (5-17 MHz) linear transducer in a tube filled with normal saline and MRI in a 8-channel quadrate head coil. The institutional review board approved this study and informed consent was waived. MRI with seven pulse sequences of in- and out-of-phases gradient echo T1 weighted images, fast spin echo T2 weighted image and its fat suppression image, fast imaging employing steady-state acquisition (FIESTA) and its fat suppression image, and diffusion weighted image (DWI) were performed. In each case, both imaging findings of MRI and US were evaluated independently for detection and estimation of invasion depth of tumor by consensus of two radiologists and were compared about diagnostic accuracy according to the histopathologic findings as reference standard. Seven MR pulse sequences were evaluated on the point of accurate delineation of tumor from surrounding normal tissue in each specimen. Results: In specimens of CRC, both imaging modalities of MRI (91.1%) and US (86.7%) showed relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of tumor. In early CRC, diagnostic accuracy of US was 87.5% and that of MRI was 75.0%. There was no statistically significant difference between two imaging modalities (p > 0.05). The best pulse sequence among seven MR sequences for accurate delineation of tumor from surrounding normal tissue in each specimen of CRC was fast spin echo T2 weighted image. Conclusion: MRI and US show relatively high diagnostic accuracy to detect tumor and evaluate invasion depth of resected specimen of CRC. The most excellent pulse sequence of MRI for accurate delineation of tumor from surrounding normal tissue in CRC is fast spin echo T2 weighted image.