• Title/Summary/Keyword: In-tube

Search Result 10,209, Processing Time 0.048 seconds

Adenoviral Lower Respiratory Tract Infection of Children in Korea from 1990 Through 1998 (소아의 Adenovirus 하기도 감염증에 관한 연구 - 유행 양상과 임상 양상에 대하여 -)

  • Hong, Jung Youn;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.1
    • /
    • pp.94-107
    • /
    • 2000
  • Purpose : The purpose of this study is to know the clinical manifestations and the severity of adenoviral lower respiratory tract infections(LRTI) in Korean children. Methods : Adenoviral respiratory infection was diagnosed by viral culture in HEp-2 cell and indirect immunofluorescent technique with nasal aspirates. Isolated adenoviruses were typed by neutralization test. Retrospective chart review was done in patients with adenoviruses were typed by neutralization test. Retrospective chart review was done in patients with adenoviral lower respiratory tract infection, who were brought to Seoul National University Children's Hospital from November 1990 through February 1998. Results : Adenovirus was isolated in 87 cases. Of 84 cases serotyped, type 1 was recovered in 3 cases, type 2 in 13 cases, type 3 in 13, type 4 and 5 in 4 cases each other, type 6 in 1 cases, type 7 in 36 cases, type 11 in 1 case and the other types in 9 cases. Adenoviral lower respiratory infection occurred sporadically throughout the year but from November 1995 through February 1998, an outbreak of adenovirus type 7 lower respiratory infection was observed in number upto 36 case. The incidence of adenoviral infection peaked in young children between 6 months and 5 years of age and the mean age was 1 year 11 months old. There were 10 cases of mixed infection with another pathogen. Clinical diagnosis were pneumonia(88%), acute broncholitis(5.4%), acute tracheobronchitis(5.4%), croup(1.3%). The clinical features of adenoviral lower respiratory infection were severe especially in type 3 and 7 infections in aspect of fever duration, ventilator care. Extrapulmonary manifestations were gastrointestinal symptoms in 23 cases(31%), hepatomegaly in 36 cases(53%), seizure and mental alteration in 13 cases(20.3%). In chest radiographic findings, parahilar and peribronchial infiltration were in 49 cases(67%), hyperaeration in 21 cases(29%), atelectasis in 14 cases(19%), consolidation in 39 cases(53%) and bilateral pneumonic infiltration in 28 cases(38%). Among thirty six adenovirus type 7 LRTI, 15 patients(41.6%) had pleural effusion and 3 patients had chest tube insertion. Number of fetal cases related to adenovirus were 9 cases(12%) and fetal cases due to ventilatory failure were 7(11%). Conclusion : During 7 year period of studying adenoviral lower respiratory infection, we identified the serotypes of adenovirus. Among the serotypes, adenovirus type 7 were epidemically isolated. Adenovirus were isolated in severe lower respiratory infection of young children aged between 6 months and 5 years and related to death of the patients, especially when the patients had underlyng diseases or were infected by adenovirus type 7.

  • PDF

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

The Use of Radioactive $^{51}Cr$ in Measurement of Intestinal Blood Loss ($^{51}Cr$을 사용(使用)한 장관내(賜管內) 출혈량측정법(出血量測定法))

  • Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.19-26
    • /
    • 1970
  • 1. Sixteen normal healthy subjects free from occult blood in the stool were selected and administered with their $^{51}Cr$ labeled own blood via duodenal tube and the recovery rate of radioactivity in feces and urine was measured. The average fecal recovery rate was 90.7 per cent ($85.7{\sim}97.7%$) of the administered radioactivity, and the average urinary excretion rate was 0.8 per cent ($0.5{\sim}1.5%$) 2. There was a close correlation between the amount of blood administered and the recovery rate from the feces; the more the blood administered, the higher the recovery rate was. It was also found that the administration of the tagged blood in the amount exceeding 15ml was suitable for measuring the radioactivity in the stools. 3. In five normal healthy subjects whose circulating erythrocytes had been tagged with $^{51}Cr$, there was little fecal excretion of radioactivity (average 0.9 ml of blood per day). This excretion is not related to hemorrhage and the main route of excretion of such an negligible radioactivity was postulated as gastric juice and bile. 4. A comparison of the radioactivity in the blood and feces of the patients with $^{51}Cr$ labeled erythrocytes seems to be a valid way of estimating intestinal blood loss.

  • PDF

Microbial Growth in Dried Fishes During Preservation (건어물 저장 중 미생물 증식상태에 관한 연구)

  • 이현자;김종군;이수정;조한옥
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.3
    • /
    • pp.135-140
    • /
    • 1993
  • Dried fishes such as dried pollack, dried sliced squid, dried white bait, dried anchoy) and dried cod used to cook Korean traditional foods were airpacked in polyethylene tube and irradiated with 7 kGy of gamma-ray source. The effect of gamma irradiation on microbial growth in dried fishes was investigated during storage at ambient temperature for 12 months. The total aerobic bacteria in the control group were contaminated by $3.9{\times}10^{3}\;cells/g$ in dried pollack, $5.6{\times}10^{5}\;cells/g$ in dried sliced squid, $1.2{\times}10^{5}\;cells/g$ in dried white bait, $1.2{\times}10^{4}\;cells/g$ in dried anchovy and $1.2{\times}10^{4}\;cells/g$ in dried cod and 7 kGy irradiation could eliminate the bacteria and also reduce aerobic bacterial load to 1~3 log cycle and no apparent growth of microorganisms occurred during storage. Molds in the control group were contaminated by $4.0{\times}10^{2}\;cells/g$ in dried pollack, $$1.3{\times}10^{2}\;cells/g$ in dried sliced squid, $2.5{\times}10^{2}\;cells/g$ in dried white bait, 90 cells/g in dried anchovy and $2.0{\times}10^{2}\;cells/g$ in dried cod, respectively. 7 kGy irradiation could sterilize the molds and the growth of molds of nonirradiated samples were slightly decreased during storage. Yeasts in the control group were contaminated by $1.4{\times}10^{3}\;cells/g$ in dried poUack, 75 cells/g in dried sliced squid, $1.1{\times}10^{3}\;cells/g$ in dried white bait, 50 cells/g in dried anchovy, $1.6{\times}10^{2}\;cells/g$ in dried cod, respectively and irradiation could sterilize the yeasts and growth of yeasts was slightly decreased in dried pollack and dried white bait but increased in order of dried anchovy, dried cod and dried sliced squid. Coliforms in all sample were sterilized by irradiation and its growth was decreased during storage except dried anchovy.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2011 (설비공학 분야의 최근 연구 동향: 2011년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Paik, Yong-Kyoo;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.521-537
    • /
    • 2012
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2011. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of fluid machinery and fluid flow, thermodynamic cycle, and new and renewable energy. Various topics were presented in the field of fluid machinery and fluid flow. Research issues mainly focused on the rankine cycle in the field of thermodynamic cycle. In the new and renewable energy area, researches were presented on geothermal energy, fuel cell, biogas, reformer, solar water heating system, and metane hydration. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, nanofluids and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer above liquid helium surface in a cryostat, methane hydrate formation, heat and mass transfer in a liquid desiccant dehumidifier, thermoelectric air-cooling system, heat transfer in multiple slot impinging jet, and heat transfer enhancement by protrusion-in-dimples. In the area of pool boiling and condensing heat transfer, researches on pool boiling of water in low-fin and turbo-B surfaces, pool boiling of R245a, convective boiling two-phase flow in trapezoidal microchannels, condensing of FC-72 on pin-finned surfaces, and natural circulation vertical evaporator were actively performed. In the area of nanofluids, thermal characteristics of heat pipes using water-based MWCNT nanofluids and the thermal conductivity and viscosity were measured. In the area of industrial heat exchangers, researches on fin-tube heat exchangers for waste gas heat recovery and Chevron type plate heat exchanger were implemented. (3) Refrigeration systems with alternative refrigerants such as $CO_2$, hydrocarbons, and mixed refrigerants were studied. Heating performance improvement of heat pump systems were tried applying supplementary components such as a refrigerant heater or a solar collector. The effects of frost growth were studied on the operation characteristic of refrigeration systems and the energy performance of various defrost methods were evaluated. The current situation of the domestic cold storage facilities was analyzed and the future demand was predicted. (4) In building mechanical system fields, a variety of studies were conducted to achieve effective consumption of heat and maximize efficiency of heat in buildings. Various researches were performed to maximize performance of mechanical devices and optimize the operation of HVAC systems. (5) In the fields of architectural environment and energy, diverse purposes of studies were conducted such as indoor environment, building energy, and renewable energy. In particular, renewable energy and building energy-related researches have mainly been studied as reflecting the global interests. In addition, various researches have been performed for reducing cooling load in a building using spot exhaust air, natural ventilation and energy efficiency systems.

Studies on Heterostylism, Fertility, and Embryological Characteristics in Buckwheat. Fagopyrum esculentum (메밀의 이형예현상과 수정력 발생학적 특징에 관한 연구)

  • Man-Sang Lee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.2
    • /
    • pp.129-142
    • /
    • 1986
  • Fifty-five local collections of buck wheat, Fagopyrum esculentum, were investigated their ratios of long-styled (LS) and short-styled (SS) flowers, fertility, meiosis of megaspore and microspore mother cell, female and male gametogenesis, and egg apparatus in accordance with the sowing seasons (spring, summer), altitudes (20m, 50-100m, 300m), and parent style types (L, S). Also they were embryologically investigated the fertility, fertilizing phenomenon and proembryogenesis by the legitimate and illegitimate pollination. There were no differences in the ratios of long-styled and short-5tyled flowers along with altitudes, but more irregularness was observed in plain area than that in the mountaineous or coastal area. LS versus SS ratios by sowing seasons were significantly separated into 1 : 1 in the summer sowing (P 0.1), but they were irregularly separated in the spring sowing. The segregating ratios by parent style types showed more number of short-styled flower in the spring sowing, and were statistically seperated into 1 : 1 in the summer sowing (P 0.25), regardless to parent style types. In the artificial legitimate union, the seed setting rates of the summer sowing (59-61%) were much higher than those of the spring sowing (about 30%), but in the artificial illegitimate union the seed setting rates were only fructified about 0.8-1.8% in the spring sowing. The seed setting rates in accordance with flowering stages were larger in turn early, middle, late, in the summer sowing. The grain number and grain weight per plant of short-styled flower were more than those of long-styled one regardless to style types. The 1,000 grain weight of long-styled flower was heavier than that of short-styled one in large grain, but it was lighter than that of short-styled flower in small or medium grain. The percentage of normal female and male gametogenesis in the summer sowing were higher than those in the spring sowing. The ovule was atropous and two polar nuclei were a synkarion before flowering. The pollens germinated at 30 minuts after pollination and the pollen tube grew continually and penetrated into micropyle at 1.5-2 hours and the two male nuclei fertilized with egg nucleus at 3 -5 hours after pollination. Flertilizing times in summer were shorter than in autumn. The fertilized egg was divided in a small apical cell toward the interior of the embryo sac and a large basal cell toward the micropyle cell at 15-24 hours after pollination, and division times in summer were shorter than in autumn. The proembryo began the embryogenesis at 7-8 days and formed itself into the perfect embryo at 15 days after pollination.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

A Comparison of Three Suture Techniques on Adhesion in End-to-end Intestinal Anastomosis of Dogs (개에서 세가지 단단장문합 봉합법에 따른 유착비교)

  • Kim, Je-Sun;Jeong, Soon-Wuk;Kim, Joon-Young;Jeong, Man-Bok;Han, Hyun-Jung
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.12-21
    • /
    • 2003
  • In this study, we evaluated effects of three anastomotic techniques of small intestine on adhesions in the dog. Twenty six healthy mixed dogs were randomly assigned to three groups. Group I(n = 8) was sutured with a simple continuous suture, group II(n = 7) was sutured with a simple interrupted approximating suture and group III(n = 11) was sutured with a single layer continuous Connell suture. On completion of any intestinal anastomosis, a pedicle of greater omentum was wrapped around the suture line in all experimental dogs. One percent sodium carboxymeth-ylcellulose (5ml/kg) was administrated into the abdomen by feeding tube prior to closing the last part of peritoneum in all dogs. Postoperative adhesions were evaluated at 14th day after operation. The adhesions consisted primarily in two dogs in group I, three dogs in group II and group III. There were adhesions between intestinal serosal surfaces in eight dogs in all groups, but there were no intestinal serosa-visceral peritoneum adhesion and intestinal serosa-mesentery adhesion. Mean adhesion scores were less than score 2 in all groups. Between anastomotic site and omental graft, there were 13.13$\pm$4.97 mm (mean$\pm$S.D.) adhesion formation in group I and 17.29$\pm$4.68 mm in group II and 14.64$\pm$3.80mm in group III. A simple continuous suture resulted in the least adhesion formation and a simple interrupted approximating suture resulted in the greatest adhesion formation among the groups. However, there were no significant differences among three suture techniques in the severity of adhesions. Intestinal intussusception only encountered in one dog during the 14 days, the dog operated and survived. Daily monitoring of temperature, activity, appetite, defecation and micturition were done. All of those vital signs were within normal values and there were no obvious differences among the groups. In conclusion, even though there were no significant differences among three groups, a simple continous suture pattern is recommended to prevent adhesions when operating intestinal anastomosis in dogs.

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.