• Title/Summary/Keyword: In-process Monitoring

Search Result 3,268, Processing Time 0.033 seconds

Monitoring of Benzoic, Sorbic and Propionic Acid in Cereal Grains, Nuts and Seeds (곡류 및 견과 종실류 중 안식향산, 소브산, 프로피온산의 함유량 조사)

  • Yun, Sang Soon;Lee, Sang Jin;Lim, Do Yeon;Lim, Ho Soo;Lee, Gunyoung;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • This study was aimed at investigating the levels of the natural preservatives of benzoic, sorbic and propionic acids in cereal grains, nuts and seeds. Benzoic and sorbic acid were analyzed by high-performance liquid chromatography with a diode-array detector (HPLC-DAD) and further confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), whereas propionic acid was analyzed using a gas chromatography-flame ionization detector (GC-FID) and further confirmed by gas chromatography-mass spectrometry (GC-MS). Benzoic, sorbic and propionic acids were found in 44, 22, and 550 samples out of 702 samples, respectively. From the total of 702 samples. The concentrations of benzoic, sorbic and propionic acid were ranged from not detected (ND) to 23.74 mg/L, from ND to 7.90 mg/L, and from ND to 37.39 mg/L in cereal grains, nuts and seeds, respectively. The concentration ranges determined in this study could be used as standard criteria in the process of inspecting cereal grains, nuts and seeds for preservatives as well as to address consumer complaints or trade disputes.

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

Colonization Rate and Control of Vancomycin-Resistant Enterococci in the Neonatal Intensive Care Unit (일개 신생아중환자실 반코마이신 저항 장구균(VRE)의 유행 양상과 조절)

  • Seo, Jung Ho;Nam, Ga Yeon;Park, Kyung Hee;Byun, Shin Yun;Park, Su Eun
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Purpose : Recently, vancomycin-resistant enterococci (VRE) have become one of the major nosocomial pathogens in Korea. However, there have been few studies on the epidemiology of VRE colonization among neonates. In this study, we investigated the prevalence of VRE colonization, risk factors for VRE, and how to control the spread of VRE infection in the Neonatal Intensive Care Unit (NICU) of Pusan National University Hospital (PNUH). Methods : We retrospectively reviewed medical records of 192 neonates who were admitted to the NICU of PNUH from March 2006 to March 2007. Surveillance cultures from rectal swabs for detecting VRE were obtained weekly during the study period. We analyzed the prevalence of VRE and various risk factors. Results : The rate of VRE colonization among NICU patients was 25% (48/192). Thirty five of these VRE colonized patients were transferred to the NICU from other local hospitals. Compared with the non-VRE group, the risk factors associated with VRE colonization were lower birth weight, congenital heart disease, applied mechanical ventilation, use of a central venous catheter, chest tubing, a history of surgery, and use of antibiotics. Conclusion : VRE colonization among patients admitted to the NICU is rapidly increasing. Monitoring and managing premature neonates from the beginning of the birth process, avoiding many invasive procedures, avoiding antibiotics such as vancomycin and third generation cephalosporin are important for preventing the emergence and spread of VRE colonization in the NICU.

A Study on the Australian Law Regarding RPAS (Remotely Piloted Aircraft System): Need for an International Approach

  • Wheeler, Joseph;Lee, Jae-Woon
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.311-336
    • /
    • 2015
  • This article surveys the current international law with respect to RPAS from both the public air law and private air law perspectives. It then reviews current and proposed Australian domestic RPAS regulation while emphasizing the peculiar risks in operation of RPAS; and how they affect concepts of liability, safety and privacy. While RPAS operations still constitute only a small portion of total operations within commercial aviation, international pilotless flight for commercial air transport remains a future reality. As the industry is developing so quickly the earlier the pursuit of the right policy solutions begins, the better the law will be able to cope with the technological realities when the inevitable risks manifest in accidents. The paper acknowledges that a domestic or regional approach to RPAS, typified by the legislative success of the Australian experience, is and continues to be the principal measure to deal with RPAS issues globally. Furthermore, safety remains the foremost factor in present and revised Australian RPAS regulation. This has an analogue to the international situation. Creating safety-related rules is imperative and must precede the creation or adoption of liability rules because the former mitigates the risk of accidents which trigger the application of the latter. The flipside of a lack of binding airworthiness standards for RPAS operators is potentially a strong argument that the liability regime (and particularly strict liability of operators) is unfair and unsuited to pilotless flight. The potential solutions the authors raise include the need for revised ICAO guidance and, in particular, SARPs with respect to RPAS air safety, airworthiness, and potentially liability issues for participants/passengers, and those on the ground. Such guidance could then be adapted swiftly for appropriate incorporation into domestic laws bypassing the need for or administrative burden and time it would take to activate the treaty process to deal with an arm of aviation that states know all too well is in need of safety regulation and monitoring.

A Conceptual Framework for One Source Multi Use Strategy of Culture Content (브랜드 아이덴티티 기반 문화콘텐츠 OSMU 전략 연구)

  • Kim, Young-Jae
    • Cartoon and Animation Studies
    • /
    • s.28
    • /
    • pp.155-180
    • /
    • 2012
  • This article is to propose a conceptual framework for the One Source Multi Use (OSMU) strategic model of culture content. In this study, OSMU is defined as a series of marketing activities to increase the value created by culture content. The framework of brand equity strategy is applied to develop the strategic model of OSMU, as both share the same goal - maximization of long term value created by brand or culture content. This article suggests the brand identity-based OSMU strategic model, in which the brand identity of culture content guides, integrates, and coordinates every decision-making of OSMU activities. For the maximization of brand equity value of culture content, the copyright holder of original content should decide the content's brand identity, which should provide the criteria of all decision makings regarding window strategy, adaptation of content to other genre, and merchandising. This brand identity-based OSMU strategic model can not only contribute to the sales of OSMU content, but also the creation of high equity culture content in the long run. Also, the model allows monitoring and evaluation of content's brand equity, which can be used for the strategic adjustment for the sake of long term value of the content. This study is differentiated from previous study on OSMU and expected to invigorate the further discussion on OSMU in several points. First, it broadens the scope of OSMU discussion as it views OSMU as a series of process including feedback. Second, this study points out the need for integration and coordination of various OSMU activities. Third, the strategic focus is laid on the value maximization of the original content, not 'multi used' content. Fourth, the suggested model emphasize the strategic role of copyright holder who takes the charge of the content brand management. Fifth, the model requires discussion on the components of marketing communication in addition to the content itself, which means the model includes the prospects, not only the content consumers, as the major future source for value creation.

The Immunohistochemical Expression of Collagens and the Morphogenesis in the Developing Mandible of Human Embryos and Fetuses (배자와 태아에서 하악골의 형태발생 및 교원질 발현에 관한 면역조직화학적 연구)

  • Kook, Yoon-Ah;Kim, Sang-Cheol;Kim, Eun-Cheol;Kim, Oh-Hwan;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.26 no.2 s.55
    • /
    • pp.187-196
    • /
    • 1996
  • Underlying malocclusions and dentofacial deformities are often related to variations in the craniofacial development. Type I and type II collagens are considered the major collagens of bone and cartilage respectively. Monitoring the patterns of those protein expressions during development will Provide a basis for the understanding of normal and abnormal growths. This study was undertaken to investigate the morphogenetic changes and the expression patterns of type I and II collagen proteins involved in the developing mandible of human embryos and fetuses. 50 embryos and fetuses were studied with Hematoxylin and Eosin, Alcian, blue-PAS, Masson Trichrome, md Immunohistochemical stains. The results were as follows : 1. A 13.5 mm embryo showed the stomatodeum with dental lamina, maxillary and mandibular processes. Meckel's cartilage appeared in the mandibular arch of a 20.5 mm embryo. New bone formation was bilaterally initiated at the outer side of middle portion of Meckel's cartilage of 22-38 mm embryos. 2. Meckel'cartilage was resorbed at the 15th week fetus. The endochondral ossification was observed where there was direct replacement of cartilage by bone. Meckel'cartilage disappeared and membraneous ossification were observed at the 25th week. 3. Before the appearance of Meckel's cartilage, the expression of type I collagen was moderate at the odontogenic epithelium of maxillary & mandibular process, but mild for the expression of type II collagen. 4. During the appearance of Meckel's cartilage and new bone formation, the immunoactivity of type II collagen was more expressed than type I collagen at the Meckel's cartilage and new bone. 5. During intrarmembranous bone formation, the expression of type II collagen was rare in the bony trabeculae. There was a switch for the expression of collagens from type II to type I during the appearance of Meckel's cartilage.

  • PDF

Detection with a SWNT Gas Sensor and Diffusion of SF6 Decomposition Products by Corona Discharges (탄소나노튜브 가스센서의 SF6 분해생성물 검출 및 확산현상에 관한 연구)

  • Lee, J.C.;Jung, S.H.;Baik, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2009
  • The detection methods are required to monitor and diagnose the abnormality on the insulation condition inside a gas-insulated switchgear (GIS). Due to a good sensitivity to the products decomposed by partial discharges (PDs) in $SF_6$ gas, the development of a SWNT gas sensor is actively in progress. However, a few numerical studies on the diffusion mechanism of the $SF_6$ decomposition products by PD have been reported. In this study, we modeled $SF_6$ decomposition process in a chamber by calculating temperature, pressure and concentration of the decomposition products by using a commercial CFD program in conjunction with experimental data. It was assumed that the mass production rate and the generation temperature of the decomposition products were $5.04{\times}10^{-10}$ [g/s] and over 773 K respectively. To calculate the concentration equation, the Schmidt number was specified to get the diffusion coefficient functioned by viscosity and density of $SF_6$ gas instead rather than setting it directly. The results showed that the drive potential is governed mainly by the gradient of the decomposition concentration. A lower concentration of the decomposition products was observed as the sensors were placed more away from the discharge region. Also, the concentration increased by increasing the discharge time. By installing multiple sensors the location of PD is expected to be identified by monitoring the response time of the sensors, and the information should be very useful for the diagnosis and maintenance of GIS.

From the Onset of Panic Symptoms to Getting to a Psychiatric Treatment : The Change by Improved Public Awareness of Panic Disorder in Korea (증상의 발현부터 치료의 시작까지 : 한국인의 공황장애 인식도 변화가 치료적 접근에 미친 영향)

  • Choi, Yong-Won;Seo, Ho-Jun;Han, Sang-Woo;Hong, Jin-Pyo;Lee, Kyoung-Uk;Kim, Se-Joo;Lim, Se-Won;Lee, Sang-Hyuk;Yang, Jong-Chul;Lee, Seung-Jae;Park, Seon-Cheol;Gim, Min-Sook;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2019
  • Objective : This study aimed to investigate the general process from the symptom onset to the psychiatric treatment in Korean panic patients and the effect of improved public awareness on it. Methods : This study has a retrospective design. The subjects were the new patients with panic disorder who visited the psychiatric outpatient clinic in twelve university-affiliated hospitals all across Korea. The medical chart was reviewed retrospectively and the data were collected including chief complaints of symptoms, recent stressors, the time to visit the psychiatric outpatient clinic, and visit of other departments and diagnostic approaches for their symptoms. Results : A total of 814 participants were included in the study. The most common department other than psychiatry the panic patients visited were cardiology (28.3%), general internal medicine (16.0%) and neurology (11.4%). The most frequently used diagnostic tests were a echocardiography (17.9%), 24-hour Holter monitoring (11.2%), and brain MRI (8.2%). Only 37.3% of participants visited psychiatric clinic directly. About 80% of participants visited psychiatric department within 1 year after their first panic symptoms and it took $13.8{\pm}13.7weeks$ on average. Comparing before and after 2012, the number of participants increased who visit directly the psychiatric clinic without visiting other departments (p=0.002) and without visiting emergency room (p<0.001). Conclusions : Our results suggest that a substantial number of patients visit departments other than psychiatry when they experience first panic symptoms. However, most patients begin psychiatric treatment within 1 year after their first symptoms and the number of patient are increasing who visit psychiatric department directly without visiting other departments.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Creation of Actual CCTV Surveillance Map Using Point Cloud Acquired by Mobile Mapping System (MMS 점군 데이터를 이용한 CCTV의 실질적 감시영역 추출)

  • Choi, Wonjun;Park, Soyeon;Choi, Yoonjo;Hong, Seunghwan;Kim, Namhoon;Sohn, Hong-Gyoo
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_3
    • /
    • pp.1361-1371
    • /
    • 2021
  • Among smart city services, the crime and disaster prevention sector accounted for the highest 24% in 2018. The most important platform for providing real-time situation information is CCTV (Closed-Circuit Television). Therefore, it is essential to create the actual CCTV surveillance coverage to maximize the usability of CCTV. However, the amount of CCTV installed in Korea exceeds one million units, including those operated by the local government, and manual identification of CCTV coverage is a time-consuming and inefficient process. This study proposed a method to efficiently construct CCTV's actual surveillance coverage and reduce the time required for the decision-maker to manage the situation. For this purpose, first, the exterior orientation parameters and focal lengths of the pre-installed CCTV cameras, which are difficult to access, were calculated using the point cloud data of the MMS (Mobile Mapping System), and the FOV (Field of View) was calculated accordingly. Second, using the FOV result calculated in the first step, CCTV's actual surveillance coverage area was constructed with 1 m, 2 m, 3 m, 5 m, and 10 m grid interval considering the occluded regions caused by the buildings. As a result of applying our approach to 5 CCTV images located in Uljin-gun, Gyeongsnagbuk-do the average re-projection error was about 9.31 pixels. The coordinate difference between calculated CCTV and location obtained from MMS was about 1.688 m on average. When the grid length was 3 m, the surveillance coverage calculated through our research matched the actual surveillance obtained from visual inspection with a minimum of 70.21% to a maximum of 93.82%.