Behaviour of a plane joint under horizontal cyclic shear loading

  • Dang, Wengang;Fruhwirt, Thomas;Konietzky, Heinz
    • Geomechanics and Engineering
    • /
    • 제13권5호
    • /
    • pp.809-823
    • /
    • 2017
  • This paper describes lab test results of artificial rock-like material samples having a plane joint. Cyclic shear tests were performed under different normal loads and different shear displacement amplitudes. For this purpose, multi-stage normal loading tests (30 kN, 60 kN, 90 kN, 180 kN, 360 kN and 480 kN) with cyclic excitation at frequency of 1.0 Hz and different shear displacement amplitudes (0.5 mm, 1.0 mm, 2.0 mm, 4.0 mm, 5.0 mm, and 8.0 mm) were conducted using the big shear box device GS-1000. Experimental results show, that shear forces increase with the increase of normal forces and quasi-static friction coefficient is larger than dynamic one. With the increase of normal loads, approaching the peak value of shear forces needs larger shear displacements. During each cycle the normal displacements increase and decrease (rotational behavior in every cycle). Peak angle of inclination increases with the increase of normal load. A phase shift between maximum shear displacement and maximum shear force is observed. The corresponding time shift decreases with increasing normal load and increases with increasing shear displacement amplitudes.

면내 전단력과 휨을 동시에 받는 직교이방성판의 탄성좌굴강도 (Elastic Buckling Strength of Orthotropic Plate under Combined In-Plane Shear and Bending Forces)

  • 윤순종;박봉현;정상균
    • Composites Research
    • /
    • 제12권2호
    • /
    • pp.46-52
    • /
    • 1999
  • 본 연구는 면내 전단과 휨을 동시에 받는 직교이방성 구조재의 복부판의 탄성좌굴거동에 대한 해석적 연구결과이다. 펄트루젼 방법으로 생산된 섬유보강 플래스틱을 직교이방성으로 간주하였다. 복부판의 좌굴해석에서 직교이방성 재료의 역학적 성질을 고려할 수 있도록 기존의 등방성 판의 좌굴해석을 위해 개발된 이론적 해를 확장하였다. 이론식의 해를 구하는 방법으로 Rayleigh-Ritz법을 사용하였으며, 면내 전단과 휨을 동시에 받는 복부판의 탄성좌굴강도를 구할 수 있는 그래프를 제시하였다. 전단과 휨의 상호작용과 관련된 설계기준에 대해서도 도한 검토하였다.

  • PDF

In-plane seismic performance of masonry wall retrofitted with prestressed steel-bar truss

  • Hwang, Seung-Hyeon;Kim, Sanghee;Yang, Keun-Hyeok
    • Earthquakes and Structures
    • /
    • 제19권6호
    • /
    • pp.459-469
    • /
    • 2020
  • An external prestressed steel-bar truss unit was developed as a new strengthening technology to enhance the seismic performance of an in-plane masonry wall structure while taking advantage of the benefits of a prestressed system. The presented method consists of six steel bars: two prestressed vertical bars to introduce a prestressing force on the masonry wall, two diagonal bars to resist shear deformation, and two horizontal bars to maintain the configuration. To evaluate the effects of this new technique, four full-scale specimens, including a control specimen, were tested under combined loadings that included constant-gravity axial loads and cyclic lateral loads. The experimental results were analyzed in terms of the shear strength, initial stiffness, dissipated energy, and strain history. The efficiency of the external prestressed steel-bar truss unit was validated. In particular, a retrofitted specimen with an axial load level of 0.024 exhibited a more stable post behavior and higher energy dissipation than a control specimen with an observed complete sliding failure. The four vertical bars of the adjacent retrofitting units created a virtual column, and their strain values did not change until they reached the peak shear strength. The shear capacity of the masonry wall structure with external prestressed steel-bar truss units could be predicted using the model suggested by Yang et al.

Behavior of light weight sandwich panels under out of plane bending loading

  • Ganapathi, S. Chitra;Peter, J. Annie;Lakshmanan, N.;Iyer, N.R.
    • Steel and Composite Structures
    • /
    • 제21권4호
    • /
    • pp.775-789
    • /
    • 2016
  • This paper presents the flexural behavior & ultimate strength performance of innovative light weight sandwich panels of size $3{\times}1.2m$ with two different solidity ratios viz. 0.5 and 0.33 under out of plane bending load. From the experimental studies, it is observed that the flexural strength and the stiffness are increased by about 46% and five folds for lesser solidity ratio case. From the measured strains of the shear connectors, full shear transfer between the concrete wythes is observed. The yielding occurred approximately at 4% and 0.55% of the ultimate deformation for 100 mm & 150 mm thick panels, which shows the large ductility characteristics of the panels. From the study, it is inferred that the light weight sandwich panels behave structurally in a very similar manner to reinforced concrete panels. Further from the numerical study, it is observed that the numerical values obtained by FE analysis are in good agreement with the experimental observations.

Determining minimum non-connected concrete panel thickness and concrete type impact on seismic behavior of CSPSW

  • Mehdi Ebadi-Jamkhaneh
    • Structural Engineering and Mechanics
    • /
    • 제91권6호
    • /
    • pp.607-626
    • /
    • 2024
  • This study explores the use of advanced concrete types to improve the performance of composite steel shear walls (CSPSWs), particularly in delaying cracking and failure. A two-phase approach is implemented. Phase I utilizes non-linear finite element analysis and Gene Expression Programming to develop a novel method for determining the minimum concrete thickness required in CSPSWs. Phase II investigates the effect of concrete type, opening area, and location on the behavior of CSPSWs with openings. The results demonstrate that ultra-high performance concrete (UHPFRC) significantly reduces out-of-plane displacement and tensile cracking compared to normal concrete. Additionally, the study reveals a strong correlation between opening position and load-bearing capacity, with position L3 exhibiting the greatest reduction as opening size increases. Finally, UHPFRC's superior energy dissipation translatesto a higher equivalent viscous damping coefficient.

철근 콘크리트 벽과 강판 콘크리트 벽이 수직으로 만나는 이질접합 구조물의 면외 휨 거동 특성 연구 (A Study on Out-of-Plane Flexural Behavior of the Structure with a Vertical Plane Connection between a Reinforced Concrete Wall and a Steel Plate Concrete Wall)

  • 황경민;이경진;함경원;김원기
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.93-102
    • /
    • 2013
  • 본 연구에서는 철근콘크리트 벽과 강판 콘크리트 벽이 서로 수직면의 이질접합 형태로 만나는 벽의 면외 휨 거동 특성을 검토하기 위하여, L형 실험체를 제작하고 휨 실험을 수행하였다. 실험 시, 실험체의 동적특성을 확인하기 위하여 Push 및 Pull 하중을 반복하는 싸이클 하중을 구현하고자 하였다. Push 하중에 의한 실험 결과, 실험체의 공칭강도를 초과하는 휨 성능을 발휘하였으며, 이에 따라 설계에 적용된 수직철근의 미겹침 이음길이의 타당성을 확인할 수 있었다. 한편, Pull 하중 가력 시에는 수직철근이 최대 내력을 발휘하기 전에 접합부 콘크리트에서 전단 파괴 거동이 나타나, 이에 대한 보강이 필요함을 확인하였다.

강판콘크리트 구조 이질접합부의 면외 휨/면내 전단하중 특성에 관한 실험연구 (An Experimental Study on Flexural/Shear Load Properties of SC(Steel Plate Concrete) Structure with Reinforced Concrete Joint)

  • 이경진;황경민;함경원;김우범
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.137-147
    • /
    • 2012
  • 본 연구는 L형, I형 실험체에 강판 콘크리트 구조와 철근콘크리트 구조를 적용하여 이질접합부를 만들고, 실험체에 반복하중을 파괴 시 까지 가력하여 면외 휨 내력 및 면내 전단 내력을 평가하고 구조특성을 검토하기 위해서 실험연구를 수행하였다.본 연구에서 면외 휨 성능실험은 접합부에서 정착부 수직철근이 인발되면서 파괴되었고, 면내 전단성능실험은 기초부에서의 휨 균열이 발생하여 파괴되었으며, 이론식과의 비교결과 최대 내력이 실험값/이론값의 결과가 면외 휨성능실험은 96%, 면내 전단성능실험은 82%의 값을 나타내었다.

디지털 이미지 코릴레이션 기법으로 평가한 평면변형률 시험의 단부 구속 효과 (Restrained Effect of End Plate on Plane Strain Test Evaluated by Digital Image Correlation Method)

  • 장의룡;추윤식;이원택;정충기
    • 한국지반공학회논문집
    • /
    • 제24권7호
    • /
    • pp.25-36
    • /
    • 2008
  • 평면변형률 시험기는 실제 지반의 파괴 거동을 보다 근사하게 모사할 수 있다는 장점 때문에 평면변형률 조건을 구현하려는 목적 외에도 흙의 국부적인 변형을 포함하는 전체적인 파괴거동을 관찰하기 위한 목적으로 활용되고 있다. 그러나 대부분의 평면변형률 시험은 시험기 제작과 시험 수행의 어려움 때문에 바닥판이 고정된 단부 구속하에서 수행되는 경우가 일반적이다. 최대 주응력 면의 단부 구속은 주응력 면에 추가적인 전단응력을 유발시켜 의도된 전단 거동을 저해하므로, 시험 결과가 실제 현장에서 발생하는 전단 거동과 다를 수 있다. 본 연구에서는 바닥판 구속을 제어할 수 있는 평면변형률 시험기를 이용하여 단부 구속 여부에 따른 두 가지 시험을 주문진 표준사에 대하여 수행하였다. 시료의 국부적인 변형을 포함하는 전체적인 거동을 측정하기 위해 외부 LVDT와 함께 디지털 이미지 코릴레이션 기법(DIC)을 적용하였다. 평면변형률 시험기의 투명한 측면판을 통하여 서로 다른 시간에 촬영된 두 개의 디지털 이미지를 본 기법으로 해석하여 응력-변형률 거동과 하중 증가에 따라 나타나는 시료 내부 모든 위치에서의 국부적 변형 거동을 파악하였다. 이로써 단부 구속 여부에 따라 발생하는 평면변형률 조건하에서 사질토의 파괴면 형성과 발달과정 그리고 변형 메커니즘을 규명하였다.

SC구조 평판의 면내전단내력 평가 (Evaluation of Steel Plate Reinforced Concrete Panels under In-plane Shear)

  • 이명재;이현욱;진성찬
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.571-581
    • /
    • 2008
  • 최근 공기단축, 인건비절감 및 시공성 향상을 위한 간편한 시공법으로 그 구조적 성능이 우수한 SC구조시스템이 제안되었다. 이 연구에서는 SC구조 기술의 전반적인 연구의 일환으로 기본적인 SC구조 면내 전단력에 대한 거동특성을 파악함과 동시에 평판에 순수면내전단력을 가력하는 방법에 대해 타당성 검토를 병행한다. 특히 SC구조의 거동특성 중 순전단응력상태 및 축력과 전단응력이 동시에 작용하는 상황에서 면내전단에 대한 내력과 변형 등 기본적 역학특성 및 구조적 성능을 파악하고 평판 면내전단가력 방법을 제안하는 것이다. SC구조 평판전단내력실험을 통해 강재와 콘크리트의 일체 거동을 통한 평판의 내력 상승 및 축력의 유무에 따른 내력 상승을 확인하였으며, 전단력에 의한 평판의 파괴 양상을 파악하였다. 또한 평판에 순수 전단력만을 가력하기 위한 4힌지 프레임에 의한 평판전단내력 실험방법의 가능성 또한 확인하였다.

비정형 구조물의 평면 회전축과 코어의 이동에 따른 지진응답분석 (Analysis of Seismic Response by the Movement of the Plane Rotation Axis and the Core of Atypical Structures)

  • 이다혜;김현수;강주원
    • 한국공간구조학회논문집
    • /
    • 제22권1호
    • /
    • pp.33-40
    • /
    • 2022
  • When the center of stiffness and the center of mass of the structure differ under the seismic load, torsion is caused by eccentricity. In this study, an analysis model was modeled in which the positions of the core and the plane rotation axis of a 60-story torsional atypical structure with a plane rotation angle of 1 degree per floor were different. The structural behavior of the analysis model was analyzed, and the earthquake response behavior of the structure was analyzed based on the time history analysis results. As a result, as the eccentricity of the structure increased, the eccentricity response was amplified in the high-rise part, and the bending and torsional behavior responses were complex in the low-order vibration mode. As a result of the analysis, the maximum displacement and story drift ratio increased due to the torsional behavior. The maximum story shear force and the story absolute maximum acceleration showed similarities for each analysis model according to the shape of the vibration mode of the analysis model.