• Title/Summary/Keyword: In-plane alignment

Search Result 174, Processing Time 0.026 seconds

Study of Ultra-Small Optical Anisotropy Profile of Rubbed Polyimide Film by using Transmission Ellipsometry

  • Lyum, Kyung Hun;Yoon, Hee Kyu;Kim, Sang Jun;An, Sung Hyuck;Kim, Sang Youl
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.156-161
    • /
    • 2014
  • Anisotropy profile of a rubbed polyimide film is investigated using both a modified ultra high precision transmission ellipsometer and the analysis software previously developed to determine the optic axis distribution of discotic liquid crystals in the wide view film. The distorted sinusoidal variation of the ellipsometric constants obtained at an oblique angle of incidence indicates that the optic axis varies from $14.7^{\circ}$ to $40.6^{\circ}$ from the sample plane. The magnitude and distribution of anisotropy is expressed in terms of no, ne, and the cosine-shaped tilt angle distribution of the optic axis in a rubbed polyimide film.

악조건하의 비동일평면 카메라 교정을 위한 알고리즘

  • Ahn, Taek-Jin;Lee, Moon-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.12
    • /
    • pp.1001-1008
    • /
    • 2001
  • This paper presents a new camera calibration algorithm for ill-conditioned cases in which the camera plane is nearly parallel to a set of non-coplanar calibration boards. for the ill-conditioned case, most of existing calibration approaches such as Tsais radial-alignment-constraint method cannot be applied. Recently, for the ill-conditioned coplanar calibration Lee&Lee[16] proposed an iterative algorithm based on the least square method. The non-coplanar calibration algorithm presented in this paper is an iterative two-stage procedure with extends the previous coplanar calibration algorithm. Through the first stage, camera, position and orientation parameters as well as one radial distortion factor are determined optimally for a given data of the scale factor and the focal length. In the second stage, the scale factor and the focal length are locally optimized. This process is repeated until any improvement cannot be expected any more Computational results are provided to show the performance of the algorithm developed.

  • PDF

Distance measurement system compensated parameters for extraction of 3D distance (원거리 물체의 3차원거리 측정시의 파라미터 보정된 거리측정시스템)

  • Kim, Jeong-Man;Kim, Young-Min;Kim, Won-Sup;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.605-606
    • /
    • 2005
  • Depth error correction effect for maladjusted stereo cameras with calibrated pixel distance parameter is presented. Intra and extra parameters should be obtain to determine the relation between image and world coordination through experiment. One difficulty is in camera alignment for parallel installation: placing two CCD arrays in a plane. If the pixel distance parameter which is one of intra parameter is calibrated with known points, such error can be compensated in some amount. Such error compensation effect with the calibrated pixel distance parameter is demonstrated with various experimental results.

  • PDF

The Predictable Factors of the Postoperative Kyphotic Change of Sagittal Alignment of the Cervical Spine after the Laminoplasty

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Kim, Dong Ha;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.577-583
    • /
    • 2017
  • Objective : Laminoplasty is an effective surgical method for treating cervical degenerative disease. However, postoperative complications such as kyphosis, restriction of neck motion, and instability are often reported. Despite sufficient preoperative lordosis, this procedure often aggravates the lordotic curve of the cervical spine and straightens cervical alignment. Hence, it is important to examine preoperative risk factors associated with postoperative kyphotic alignment changes. Our study aimed to investigate preoperative radiologic parameters associated with kyphotic deformity post laminoplasty. Methods : We retrospectively reviewed the medical records of 49 patients who underwent open door laminoplasty for cervical spondylotic myelopathy (CSM) or ossification of the posterior longitudinal ligament (OPLL) at Pusan National University Yangsan Hospital between January 2011 and December 2015. Inclusion criteria were as follows : 1) preoperative diagnosis of OPLL or CSM, 2) no previous history of cervical spinal surgery, cervical trauma, tumor, or infection, 3) minimum of one-year follow-up post laminoplasty with proper radiologic examinations performed in outpatient clinics, and 4) cases showing C7 and T1 vertebral body in the preoperative cervical sagittal plane. The radiologic parameters examined included C2-C7 Cobb angles, T1 slope, C2-C7 sagittal vertical axis (SVA), range of motion (ROM) from C2-C7, segmental instability, and T2 signal change observed on magnetic resonance imaging (MRI). Clinical factors examined included preoperative modified Japanese Orthopedic Association scores, disease classification, duration of symptoms, and the range of operation levels. Results : Mean preoperative sagittal alignment was $13.01^{\circ}$ lordotic; $6.94^{\circ}$ lordotic postoperatively. Percentage of postoperative kyphosis was 80%. Patients were subdivided into two groups according to postoperative Cobb angle change; a control group (n=22) and kyphotic group (n=27). The kyphotic group consisted of patients with more than $5^{\circ}$ kyphotic angle change postoperatively. There were no differences in age, sex, C2-C7 Cobb angle, T1 slope, C2-C7 SVA, ROM from C2-C7, segmental instability, or T2 signal change. Multiple regression analysis revealed T1 slope had a strong relationship with postoperative cervical kyphosis. Likewise, correlation analysis revealed there was a statistical significance between T1 slope and postoperative Cobb angle change (p=0.035), and that there was a statistically significant relationship between T1 slope and C2-C7 SVA (p=0.001). Patients with higher preoperative T1 slope demonstrated loss of lordotic curvature postoperatively. Conclusion : Laminoplasty has a high probability of aggravating sagittal balance of the cervical spine. T1 slope is a good predictor of postoperative kyphotic changes of the cervical spine. Similarly, T1 slope is strongly correlated with C2-C7 SVA.

Transflective IPS LCD with Multi-Domain Structures

  • Park, Kyoung-Ho;Ko, Young-Jo;Kim, Jung-Hyoung;Kim, Jae-Chang;Yoon, Tae-Hoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.895-898
    • /
    • 2004
  • We propose configurations for a transflective in-plane switching (IPS) cell using muti-domain structures. Usually, the cell configurations for a transflective liquid crystal(LC) cell have a complicated structure, because retardation change of transmissive part and reflective part are not same. The transflective LC cell should have two configurations for each part, such as a multi-cell gap structure. With the ion-beam alignment and the horizontal switching LC cell, a simple structure for a transflective LC cell is proposed. The configuration only adopts one cell gap structure, which may help the enhancement of a yield. Their original optical properties in conventional transmissive and reflective type IPS liquid crystal dispaly(LCD) are kept, it shows the wide-viewing angle and the good wavelength dispersion characteristics.

  • PDF

A Camera Calibration Algorithm for an Ill-Conditioned Case (악조건하의 카메라 교정을 위한 알고리즘)

  • Lee, Jung-Hwa;Lee, Moon-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.2 s.95
    • /
    • pp.164-175
    • /
    • 1999
  • If the camera plane is nearly parallel to the calibration board on which objects are defined, most of existing calibration approaches such as Tsai's radial-alignment-constraint method cannot be applied. Recently, for such an ill-conditioned case, Zhuang & Wu suggested the linear two-stage calibration algorithm assuming that the exact values of focal length and scale factor are known a priori. In this paper, we developed an iterative two-stage algorithm starts with initial guess fo the two parameters to determine the value of the others using Zhuang & Wu's method. In the second stage, the two parameters are locally optimized. This process is repeated until any improvement cannot be expected any more. The performance comparison between Zhuang & Wu's method and our algorithm shows the superiority of ours. Also included are the computational results for the effects of the distribution and the number of calibration points on the calibration performance.

  • PDF

Polarizing Photovoltaic Polymer Films for Reflective Solar-LCDs (편광 흡수성 광기전성 고분자 박막 연구)

  • Kim, Young-Chan;Huh, Yoon-Ho;Park, Byoung-Choo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.7
    • /
    • pp.525-530
    • /
    • 2012
  • We present the results of a study of the polarizing photovoltaic (PV) effects in an aligned polymer bulk heterojuction PV layer. The fairly uniform in-plane uniaxial alignment of the PV layer with a macroscopic axial orientational order parameter of 0.40 was achieved by means of a simple rubbing technique. Moreover, reflective polarizing PSCs having the aligned PV layers were applied to power-generating reflective type liquid crystal displays (LCDs), which exhibited a maximum contrast ratio of 1.7. These results form a promising foundation for various energy harvesting polarization dependent opto-electrical LCD device applications.

The Circuit Simulation Study on Greenish Phenomenon in TFT-LCD Induced by Vcom Voltage Distortion (TFT-LCD에서 공통전극 왜곡에 의해 유발된 녹색 편향 현상에 대한 연구)

  • Hong, Joon-Eui;Kim, Jong-Tae;Chai, Jong-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.179-182
    • /
    • 2005
  • 현재 액정 표시장치는 액정의 유전율 이방성 특성에 따라 Positive LC 와 Negative LC로 구분되어 개발 된다. Positive LC에는 TN(Twisted Nematic)모드와 IP(In Plane Switching) 모드가 있다. Negative LC에는 VA(Vertical alignment) 모드가 있다. 데이타 전압을 교류구동 시키므로, LCD Pixel들은 극성반전을 하게 되며, 이때 특정 Pattern에서 화면상에 비정상적인 색깔이 나타난다. 특정 Pattern이란 데이타 전압이 교류구동을 할 때, Vcom Level이 데이타 전압에 의한 Coupling 때문에 왜곡이 발생되고, 이 왜곡에 의하여 레드, 그린, 블루 Pixel의 충전을 차가 발생해서, 화면의 좌우는 적색편향 하게 보이고, 중앙은 녹색편향 발생된다.

  • PDF

Flexible LCDs with Columnar Spacers for Fast Response and Wideviewing

  • Kim, Dong-Woo;Lim, Yong-Woon;Na, Jun-Hee;Yu, Chang-Jae;Lee, Sin-Doo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.407-410
    • /
    • 2005
  • We report on a high speed flexible display based on a deformed helix ferroelectric liquid crystal (DHFLC) in a vertically aligned configuration. The mechanical stability of the flexible DHFLC display was achieved using a periodic array of columnar spacers formed directly on the top sides of in-plane electrodes by the photolithography technique. Several unique features of display performances such as flexibility, uniform alignment, fast response, and gray scale capability were obtained.

  • PDF

Preparation of Epitaxial $LaSrCoO_3/SrTiO_3(100)$ Structures by The Chemical Solution Process (화학적 용액법에 의한 에피탁샬 $LaSrCoO_3/SrTiO_3(100)$ 구조의 제조)

  • 이형민;황규석;송종은;류현욱;강보안;윤연흠;김병훈
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.10
    • /
    • pp.1075-1079
    • /
    • 1999
  • LaSrCoO3 thin films were spin-coated onto the SrTiO3(100) substrates by the chemical solution process. X-ray diffraction $\theta$-2$\theta$ scans and X-ray diffraction $\beta$ scans were used to determine the crystallinity and in -plane alignment behavior of the films. The X-ray diffraction pattern showed the film obtained by annealing at 80$0^{\circ}C$ was highly oriented. The X-ray diffraction pole-figure analysis and reciprocal-space mapping (2$\theta$-$\Delta$$\omega$ scans) of the resulting film showed that the film comprising the pseduocubic phase had an epitaxial relationship with the SriO3 substrate.

  • PDF