• Title/Summary/Keyword: In-phase/Out-phase

Search Result 4,165, Processing Time 0.037 seconds

Free Vibration Analysis of Two Identical Rectangular Plates Coupled with Fluid (유체로 연성된 동일한 두 직사각 평판의 고유진동 해석)

  • Jeong, Kyeong-Hoon;Lee, Seong-Cheol;Yoo, Gye-Hyoung
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.8-15
    • /
    • 2002
  • In order to investigate the vibration characteristics of fluid-structure interaction problem, we modeled two identical rectangular plates coupled with fluid. A commercial computer code, ANSYS was used to perform finite element analysis and FEM solutions were compared with the experimental results to verify the finite element model. As a result, comparison of FEM and experiment showed good agreement, and the transverse vibration modes, in-phase and out-of-Phase, were observed alternately in the fluid-coupled system. The effect of fluid gap size on the fluid-coupled natural frequency were investigated. It was shown that the mode numbers increased, the normalized natural frequencies monotonically increased. And it was also found that an increase of the fluid gap reduced the coupled natural frequencies for the in-phase modes but increased the coupled natural frequencies for the out-of phase modes, and eventually converged to the results of an infinite fluid gap.

Experimental Study on the Flow Characteristics of Sinusoidal Nozzle Jet (정현파 형상 노즐 제트의 유동특성에 관한 실험적 연구)

  • Kim, Hak-Lim;Rajagopalan, S.;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.2
    • /
    • pp.28-34
    • /
    • 2010
  • Two turbulent jet with different sinusoidal nozzle exit configurations of in-phase and $180^{\circ}$ out-of-phase were investigated experimentally using a smoke-wire method and a hot-wire anemometry. Mean velocity and turbulence intensity were measured at several downstream locations under $Re_D\;=\;5000$. For the case of in-phase nozzle configuration, the length of potential core exhibits negligible difference with respect to the transverse locations (0, $\lambda/4$ and $\lambda/2$), similar to that of a plane jet. On the other hand, a maximum difference of 30% in the potential-core length occurs for the $180^{\circ}$ out-of-phase configuration. The spatial distributions of turbulence intensities also show significant difference for the nozzle of $180^{\circ}$ out-of-phase, whereas non-symmetric distribution is observed in the near-exit region(x/D = 1) for the in-phase sinusoidal nozzle jet. Compared to a slit planc jet, the sinusoidal nozzle jets seem to suppress the velocity deficit as the flow goes downstream. The sinusoidal nozzle jet was found to decrease turbulent intensity dramatically. The flow visualization results show that the flow characteristics of the sinusoidal nozzle jet are quite different from those of the slit plane jet.

Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1203-1210
    • /
    • 2004
  • It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.

A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications (진단용 X선장치의 성능 실태 조사연구)

  • Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

The X-Ray Study on Macrostress and Microstress for Two-Phase Stainless Steel (二相스테인리스鋼의 X線에 의한 巨視的.微視的 應力에 關한 硏究)

  • ;;廣賴幸雄
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.141-150
    • /
    • 1994
  • The residual stress is inevitably introduced into composites because of the mismatch of the coefficient of thermal expansion, and it is different in each phase. The X-ray technique can detect separately the stress in each phase, so will wield useful information for analyzing the toughening mechanisms of composites. In order to apply the law of mixture to alloy steels with composite microstructures, two phase stainless steel, consisted of ferrite (.alpha.-Fe) and austenite (.gamma.-Fe) structures, was selected. The tensile elastic deformation was loaded, and then the X-ray diffraction technique was used to measure the X-ray elastic constants, the X-ray stress constants and the phase stresses. The law of mixture was investigated and the separation of macrostress and microstress was carried out. The phase stresses (the residual stresses of phase) in each phase, which were measured by X-ray technique, was directly proportional to the applied stress. The macrostress calculated from the phase stresses by using the law of mixture was nearly equal to the applied stress.

  • PDF

Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review (간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

Biomechanical Analysis on Change of Toe-out Angle in Squat (스쿼트 시 Toe-out 각도 변화에 따른 운동역학적 변인 분석)

  • Song, Hyeong Kyeong;So, Jae Moo
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.185-196
    • /
    • 2019
  • Objective: The aim of this study was to suggest correct and effective way of squat through biomechanical analysis variables on the change of the toe-out angle. Method: 7 high school male weightlifter (age: $17.57{\pm}0.53yrs$, height: $174.0{\pm}3.93cm$, weight: $81.0{\pm}9.17kg$, 1RM: $164.29{\pm}20.7kg$) participated in this study. Results: Angle of the hip joint at E2 was smaller than toe-out angle was in $20^{\circ}$ than in $0^{\circ}$ (p<.05). Angular velocity of the foot joint at E1 and E3 was quicker that in $10^{\circ}$ than in $30^{\circ}$ (p<.05). Anterior-posterior stability index was greater that toe-out angle was in $30^{\circ}$ than in $0^{\circ}$ (p<.05). In average iEMG of flexion phase, VM of right, left leg showed high activity at toe-out angle $30^{\circ}$. In average iEMG of flexion phase, extension phase and in peak iEMG, RF of right leg, VM and VL of left leg showed high activity at all of the toe-out angles. In average iEMG of flexion phase, extension phase and in peak iEMG, all of the muscles activity of right leg showed high in $10^{\circ}$ and low in $0^{\circ}$, $30^{\circ}$. Conclusion: It is judged that setting the toe-out angle $10^{\circ}$ in squat help to efficiently use muscles and ensure stability.

A Photometric Investigation of KIC6118779 with Phase Smearing Effect

  • Jeong, Min-ji;Kim, Chun-Hwey
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.63.3-64
    • /
    • 2017
  • KIC6118779 is an over-contact binary system having a short orbital period of about 0.36 days. The photometric data for this system are acquired by the observations of Kepler mission in the long cadence mode having a time resolution of about 30 minutes. It means that the Kepler light curves of the system may be strongly affected by phase smearing effect and the analysis of them without consideration of the phase smearing effect may result in wrong stellar properties. Additionally, this system also shows dynamical variation of light curve resulting from spot activity. For all those reasons, it is difficult to investigate KIC6118779, and the investigation should be carried out carefully. In this presentation, we introduce the phase smearing effect and carry out the light curve modeling with the 2015 version of the Wilson-Devinney binary code considering the phase smearing effect. Our results show that the system is a deep over contact binary system and has extremely low mass ratio of about 0.12. Moreover our spot modeling implies the cyclic migration of a big cool spot on the massive component.

  • PDF

Application of Phase-Shifting Method in Speckle Interferomtery to Measurement of Micro-Scale Displacement

  • Baek, Tae-Hyun;Kim, Myung-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.162-168
    • /
    • 2006
  • Speckle interferometry with phase-shifting method has been applied to measurement of micro-scale displacement through optical signal processing. Four-step phase-shifting method by PZT is used to measure out-of-plane displacement in spot-welded cantilever and results of optical experiments are comparable to those of FEM. Phase-shifting method using Fourier transform by PZT is applied to measurement of in-plane displacement on rectangular steel plate with a circular hole. The results of optical experiment agree well with theoretical calculation. New phase-shifting method in speckle interferometry has been implemented with a quarter wave plate. In-plane displacement of specimen is measured by the new phase-shifting method. Results of optical experiment show that the quarter wave plate can be used for phase-shifting method that is cheap and easy to use in speckle interferometry.

Evaluation of Shear-Induced Phase Transformation of $\beta$-Cristobalite by Fiber Push-Out Technique

  • Sang Jin Lee;Dong Zhu;Jae Suk Sung
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.208-212
    • /
    • 1997
  • Shear-induced phase transformation behavior of chemically stabilized $\beta$-cristobalite was studied by the fiber push-out technique. To obtain the critical grain size for phase transformation, the hot-pressed polycrystalline $\beta$-cristobalite, which was used as the interphase between fiber and matrix, was annealed at $1300^{\circ}C$ for 10h. Two types of fibers, mullite and sapphire fiber, were used in this study. Debonding between mullite fiber and cristobalite interphase occurred at a critical load of 230 MPa. Static friction and fiber sliding were continuously followed by debonding. Shear-induced transformation induced cracks in the cristobalite interphase at the debonding stage. In the case of the sapphire fiber, the debonding occurred at a lower load of 180 MPa due to the residual stress in the interface caused by the difference in thermal expansion coefficients between the fiber and the cristobalite interphase. The load was insufficient for shear-induced phase transformation.

  • PDF