• Title/Summary/Keyword: In-line inspection

Search Result 538, Processing Time 0.028 seconds

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Kim, Yoo-Sung;Song, Yoon-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1100-1109
    • /
    • 2006
  • In this study, two different technologies which can measure temperature simultaneously at many points are introduced. One is to use a thermal sensor cable that is comprised of addressable thermal sensors connected in parallel within a single cable. The other is to use an optic fiber with Distributed Temperature Sensing (DTS) system. The difference between two technologies can be summarized as follows. A thermal sensor cable has a concept of 'point sensing' that can measure temperature at accurate position of a thermal sensor. So the accuracy and resolution of temperature measurement are up to the ability of the thermal sensor. Whereas optic fiber sensor has a concept of 'distributed sensing' because temperature is measured by ratio of Stokes and anti-Stokes component intensities of Raman backscatter that is generated when laser pulse travels along an optic fiber. It's resolution is determined by measuring distance, measuring time and spatial resolution. The purpose of this study is that application targets of two temperature measurement techniques are checked in technical and economical phases by examining the strength and weakness of them. Considering the functions and characteristics of two techniques, the thermal sensor cable will be suitable to apply to the assessment of groundwater flow, geothermal distribution and grouting efficiency within 300m distance. It is expected that the optic fiber sensor can be widely utilized at various fields (for example: pipe line inspection, tunnel fire detection, power line monitoring etc.) which need an information of temperature distribution over relatively long distance.

  • PDF

The School Foodservice Securement Facilities and Perceptions of Barriers to Implementation of HACCP System in School Foodservice in Seoul Area (서울지역 학교급식 시설 현황 및 HACCP 시스템 운영에 따른 장애요인 인지도 조사)

  • Lee, Ae-Rang
    • The Korean Journal of Food And Nutrition
    • /
    • v.26 no.3
    • /
    • pp.578-590
    • /
    • 2013
  • The subject study was targeted towards nutrition teacher (dietitian) of elementary, middle, and high schools in Seoul areal. In addition, this study was to investigate the current status of school foodservice securement facilities & equipments and to analyze the obstructive factors for executing the HACCP system. The aim of this study was to provide base-line data so that a more efficient & effective sanitary management system for school foodservise can be settled in. All surveys were distributed and collected via email. A total of 305 survey papers were collected and out of these, 300 school results were analyzed and the results are as follows. The order of the securement facilities & equipment furnished were pre-handing equipments>washing>cooking>inspection>facilities>storage>space area>distribution equipments. The awareness of obstructive factors in executing the HACCP system was a total of 3.17 points and the order was as follows. The general obstructive factors>obstructive factors in the cooking staff executing the HACCP system>collaboration between the school/team leaders and the budget supporting department>obstructive factors in the nutrition teacher (dietitian) executing the HACCP system. School foodservice securement facilities & equipments in Seoul area must be renovated and modernized so as to improve its current situation. Furthermore, leadership programs are necessary to enhance nutritionists' understanding of the HACCP system and the cooking staff's competencies in instructing and supervising.

Demographics of Isolated Galaxies along the Hubble Sequence

  • Kim, Hong-Geun;Park, Jongwon;Seo, Seong-Woo;Yi, Sukyoung K.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.73.1-73.1
    • /
    • 2015
  • Isolated galaxies in low-density regions are significant in the sense that they are least affected by the hierarchical pattern of galaxy growth and interactions with perturbers at least for the last few Gyr. To form a comprehensive picture of the star formation history of isolated galaxies, we construct a catalog of isolated galaxies and their comparison sample in relatively denser environments. The galaxies are drawn from SDSS DR7 in the redshift range of 0.025 < z < 0.044. We performed visual inspection and classified their morphology following the Hubble classification scheme. We have investigated the color-magnitude diagram and found elliptical and unbarred spiral galaxies in isolated systems are relatively fainter and bluer than those in denser regions. For the spectroscopic study, we make use of the OSSY catalog (Oh et al. 2011). Our analysis on the absorption-line properties based on the comparison with stellar population models suggests that isolated elliptical galaxies are likely to be younger and metal poorer, while isolated Sc-type galaxies seem to have older luminosity-weighted ages, than their high-density counterpart. In addition, according to the BPT diagnostics, early-type galaxies among isolated galaxies are rather evenly classified into star forming, composite, Seyfert and LINER, whereas their comparisons are mainly populated in the LINER region. On the other hand, late-type galaxies do not show any prominent difference. We discuss the evolutionary histories of isolated galaxies in the context of the standard ${\Lambda}CDM$ cosmology.

  • PDF

Changes in Atmospheric Mercury Concentrations in Seoul, Korea and its Significance: A Case Study Between 1997 and 2002

  • Kim Ki-Hyun;Kim Min-Young;Hong SM
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E1
    • /
    • pp.1-11
    • /
    • 2005
  • The concentration levels of gaseous elemental mercury (GEM) in ambient air have been investigated from a monitoring station located in Yang Jae district of Seoul, Korea for a long-term period covering 1997 through 2002. The mean concentration of Hg, if computed based on its hourly measurement data for this six-year period, was $5.32\pm3.53 ng m^{-3} (N = 27,170)$. The inspection of the diurnal distribution patterns indicated the presence of notably high concentration levels during nighttime relative to daytime (e.g., the mean hourly value as high as $9 ng m^{-3}$ in winter nighttime). When divided seasonally, the highest mean of $6.12 ng m^{-3}$ was also observed during winter followed by spring, fall, and summer. The results of our analysis confirmed the relative dominance of winter (seasonally) or nighttime (diurnally), while exhibiting a complicated trend on a long-term basis. Examination of our data over a different temporal scale consistently indicated that dynamic changes in Hg concentrations occurred through time in line with changes in the strength and diversity of the source processes. It is thus acknowledged that the presence of unusually high Hg levels is the consequence of intense man-made activities, while such signatures can vary in a competitive manner.

Investigation of Effective Maintenance System for the Infra on the Conventional Line Prepared for the Tilting Train Service (틸팅열차 상용화대비 기존선 인프라시스템의 효율적 유지보수체계 검토)

  • Yoo, Keun-Su;Lee, Chang-Hun;An, Gang-Yell;Kim, Joung-Tea
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.79-87
    • /
    • 2008
  • The major objective of this study is to investigate the effective maintenance system for the infrastructure on the conventional lines in which the tilting train runs. In order to the speed-up of conventional lines that have many curve lines, there needs a improvement construction of substructure such as the straight or double track work and so on. But in this case, it needs to have a plenty of the cost and the period. Therefore, the tilting train which provides the high-speed service effectively in curve tracks was developed. Besides, the efficiency prediction and the linear fitness of the existing conventional lines for a tiling train service were examined on the preceding study which was the development of track system innovation technology for speed-up of them. So, in this paper we propose the more effective maintenance method than the existing it in order to securing the high reliability and safety classified by the infrastructure, in analyzing foreign materials and the maintenance as well as the inspection cycle concerning domestic infrastructures of the track and the catenary etc. on the railway. And we look forward to playing a decisive role as reference material for the effective improvement of the existing maintenance about the infra on the conventional lines for the commercial service of the tilting train.

  • PDF

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

Variation and Sex-limited Expression of Fluorescent Color by Ultraviolet Spectrum on the Silkworm Cocoon (누에고치의 분광성에 관한 계통별 변이 및 한성적 발현)

  • 한명세
    • Journal of Sericultural and Entomological Science
    • /
    • v.39 no.1
    • /
    • pp.22-29
    • /
    • 1997
  • Ultraviolet weavelength (UV) of 366 nm produced clearer fluorescent dolor than that of 254 nm for the inspection of silkworm cocoons. Fluorescent color of silkworm cocoons varied in color, appears no relationship with the natural color under the normal light. Uniformity of fluorescent color was improved by selection of blue or yellow line from wild types. Blue and yellow, located at the opposite poles on the color solid and L*a*b* color system, confirmed as pure standard of fluorescent color in the silkworm races for commercial white cocoons. the cocoons with blue fluorescence occupied as high as 1.7 to 8.6 times than those with yellow in the Japanese silkworm races. Fluorescence of silkworm cocoon was not affected by forced flow dry at 70$^{\circ}C$ for 6 hrs. While the Japanese races revealed no sexual difference in fluorescent color, sex-dependence of the color was common in the Chinese races for commercial white cocoon. The fluorescence of cocoon shell of Chinese races showed clear separation of blue of median color. Silkworm strain of Dc20 and Fc24 were sexualy segregated 98.8${\pm}$1.20%, 99.0${\pm}$1.00% by cocoon fluorescence, as that of 99.3${\pm}$0.44% by typical larval marking of sex-limited inheritance. Specific expression of cocoon fluorescence, applicable to breeding of simple discrimination of sex for Chinese races, inspected thoroughly on the surface and inner layer of cocoon shell.

  • PDF

An Assessment of the Accuracy for Digital Radiography Image (디지털 방사선투과영상의 정밀성 평가에 관한 연구)

  • Park, Sang-Ki;Ahn, Yean-Shik;Gil, Doo-Song
    • Journal of Welding and Joining
    • /
    • v.27 no.2
    • /
    • pp.51-56
    • /
    • 2009
  • Film based radiography imaging technique has been applied to the non-destructive test in medical, aircraft, and power industries contributing to the development of the industries. However, the complex process for imaging and analysis has increasingly demanded the reformation of the radiography test. A digital radiography imaging technologies has been com out from the demand. This study was mainly focused on the assessment on the accuracy for the each image from digital radiography test and film radiography test was proven to crate a better image in sensitivity than film radiography test. In the IQI(Image quality indicator) transmission test, one or two more line can be seen in digital image than in film image. When applying to the boiler tube weld, film image is detectable to the 1.0mm depth flaw; and digital image to the 0.5mm depth flaw. As a result of this study, digital radiography technology is determined to enhance the image quality, compared to film radiography technologies

Experimental Study on the On-line Monitoring of Offshore Structures Using Acoustic Emission Technology (음향방출법을 이용한 해양구조물의 온라인 감시에 관한 실험적 연구)

  • Won, Soon-Ho;Cho, Kyung-Shik
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3B
    • /
    • pp.73-82
    • /
    • 1999
  • In this research, an experimental study is presented to check the possibilities of offshore structures monitoring using AE techniques. The underwater transducer and preamplifier are fabricated. And, it is proved that this unit can be used for the detection of AE in offshore structures. Wave propagation studies have shown that supplementary attenuations due to seawater are significantly reducing the detection range of the sensors. It excludes the possibility of offshore structures monitoring with a small number of sensors. We conclude that AE waves would be correctly detected for a path of about 3m. Tubular joints have been tested in air and underwater using simulated elastic wave. Ability of AE techniques to detect and locate cracks early in their evolution has been demonstrated. Several parameters of AE generation have been set in evidence. It has also been shown that crack development goes with an increase of AE parameter. Conclusively, it is shown that AE techniques can provide practical alternatives to present methods being used for inspection of deep-water offshore structures undergoing structural degradation due to fatigue crack growth.

  • PDF

Development of Automatic Packing System of One Station for Fasteners(II) : Packing System Manufacture and Performance Test (원 스테이션 파스너 자동포장기 개발(II) : 제작 및 성능검증)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.653-658
    • /
    • 2011
  • In general, the purpose of packaging fasteners is a series of management activities to maintain the condition at the time of production until they get delivered to the end user. An automatic packing system for fasteners is consisted of bucket conveyor, slide feeder, vision inspection system, box-magazine conveyor system and automatic packing machine. Also, the automatic packing machine is consisted of six modules including charging device, clamping/opening device, sealing/cutting device, feeding/air-shower device, supplying/adjusting device and device frame, etc. In this paper, we proposed an automatic packing mechanism of the one station concept for packing work of fastener objects where the continuous batch work is performed in a finite space. The proposed one-station packing mechanism has been optimized through mechanical, dynamical, structural and fluid analyses. And it had been manufactured as the prototype of automatic packing machine. The field test for validation of performance was performed directly at the production line of bolt and screw. In the field test, this packing machine showed an efficiency of about 4.5 times the manual operation. It also showed 30% reduction in the consumption of packing materials compared to the manual operation. This automatic packing machine for fastener objects will be commercialized soon.