• 제목/요약/키워드: In-grid Condition

검색결과 592건 처리시간 0.029초

간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환 (Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters)

  • 송인종;최준수;임경배;최재호
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

비정현 계통 전압하에서 단상 인버터의 PLL 성능 개선 방법 (A Method to Improve the Performance of Phase-Locked Loop (PLL) for a Single-Phase Inverter Under the Non-Sinusoidal Grid Voltage Conditions)

  • 칸 레이안;최우진
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.231-239
    • /
    • 2018
  • The phase-locked loop (PLL) is widely used in grid-tie inverter applications to achieve a synchronization between the inverter and the grid. However, its performance deteriorates when the grid voltage is not purely sinusoidal due to the harmonics and the frequency deviation. Therefore, a high-performance PLL must be designed for single-phase inverter applications to guarantee the quality of the inverter output. This paper proposes a simple method that can improve the performance of the PLL for the single-phase inverter under a non-sinusoidal grid voltage condition. The proposed PLL can accurately estimate the fundamental frequency and theta component of the grid voltage even in the presence of harmonic components. In addition, its transient response is fast enough to track a grid voltage within two cycles of the fundamental frequency. The effectiveness of the proposed PLL is confirmed through the PSIM simulation and experiments.

중첩 격자 기법을 이용한 지면 효과를 받는 RAE 101 익형의 공력 해석 (AERODYNAMICS OF THE RAE 101 AIRFOIL IN GROUND EFFECT WITH THE OVERLAPPED GRID)

  • 이재은;김윤식;김유진;권장혁
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.193-198
    • /
    • 2006
  • It takes a lot of time and effort to generate grids for numerical analysis of problems with ground effect because the relative attitude and height of airfoil should be maintained to the ground as well as the inflow. A low Mach number preconditioned turbulent flow solver using the overlap grid technique has been developed and applied to the ground effect simulation. It has been validated that the present method using the multi-block grid gives us highly accurate solutions comparing with the experimental data of the RAE 101 airfoil in an unbounded condition. Present numerical method has been extended to simulate ground effect problems by using the overlapped grid system to avoid tedious work in generating multi-block grid system. An extended method using the overlapped grid has been verified and validated by comparing with results of multi-block method and experimental data as well. Consequently, the overlapped grid method can provide not only sufficiently accurate solutions but also the efficiency to simulate ground effect problems. It is shown that the pressure and aerodynamic centers move backward by the ground effect as the airfoil approaches to the ground.

  • PDF

FPD System에서 상.하지 촬영 시 격자에 따른 환자 선량 및 화질 평가 (Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System)

  • 이인자;여영복;이태성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권4호
    • /
    • pp.341-348
    • /
    • 2010
  • 상 하지 촬영 시 서울 경기지역 병원의 FPD(Flat Pannel Detector) System 사용 실태와 격자 사용에 따른 환자 선량 및 C-D Phantom에 의한 화질평가, 임상 평가자들에 의한 영상평가를 한 결과 다음과 같은 결론을 얻었다. 1. FPD system(12대)의 사용 실태 조사결과 격자비는 8 : 1에서 13 : 1까지이며, 12 : 1이 6대로 가장 많았다. 이 중 격자의 탈 부착이 가능한 장비는 8대이지만, 사용하지 않는 것이 5대(62.5%)로 격자를 그대로 사용하는 곳이 9곳(75.5%)이었다. 2. 실험에 사용된 장비에서 격자사용으로 환자가 받은 선량이 4.13배에서 4.79배까지 많이 받는 것으로 나타났다. 3. 노출조건(mAs)의 변화(0.5배나 2.0배)에 따라 환자가 받는 선량의 차이는 환자 두께에 따라 크게 차이 나지는 않았다. 4. C-D Phantom에 따른 영상의 화질평가는 격자 사용 시와 노출량이 많아질 때 영상의 식별은 잘 되었다. 5. 임상 평가는 두께가 얇은 Hand PA 영상에서는 격자사용을 하지 않는 것이 더 좋았다. 두께가 두꺼운 Knee AP 영상에서는 격자를 사용하는 것이 좋다는 평가를 받았다. 그러나 환자선량이 적어진다면 격자를 사용하지 않겠다는 의견이 5명 중 3명으로 더 많았다.

기계학습 기반 전력망 상태예측 모델 성능 유지관리 자동화 기법 (Management Automation Technique for Maintaining Performance of Machine Learning-Based Power Grid Condition Prediction Model)

  • 이해성;이병성;문상근;김준혁;이혜선
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.413-418
    • /
    • 2020
  • 초기 학습 데이터의 과적합으로 인한 전력망 상태예측 모델의 성능 감소를 방지하고 예측모델의 예측 정확도 유지를 통한 계속적인 현장활용을 위해서는 기계학습 모델의 예측 정확도를 지속적으로 관리할 필요가 있다. 이를 위해, 본 논문에서는 다양한 요인에 의해 끊임없이 변화하는 전력망 상태 데이터의 특성을 고려하여 예측모델의 정확성과 신뢰성을 높이고 현장 적용 가능한 수준의 품질을 유지하기 위한 기계학습 기반 전력망 상태예측 모델의 성능 유지관리 자동화 기법을 제안한다. 제안 기법은 워크플로우 관리 기술의 적용을 통해 전력망 상태예측 모델 성능 유지관리를 위한 일련의 태스크들을 워크플로우의 형태로 모델링하고 이를 자동화하여 업무를 효율화 하였다. 또한, 기존 기술에서는 시도되지 않았던 학습데이터의 통계적 특성 변화 정도와 예측의 일반화 수준을 모두 고려한 예측모델의 성능 평가를 통해 성능 결과의 신뢰성을 확보하고 이를 통해 예측 모델의 정확도를 일정 수준으로 유지관리하고 더욱 성능이 우수한 예측모델의 신규 개발이 가능하다. 결과적으로 본 논문에서 제안하는 전력망 상태예측 모델 성능 유지관리 자동화 기법을 통해 예측모델의 성능 저하문제를 해결하여 분산자원 연계 등 외부 환경의 변화에 유연한 예측모델 관리를 통해 정확성과 신뢰성이 보장된 예측 모델의 지속적인 활용이 가능하다.

계통연계형 인버터 병렬운전 시 LCL 필터 상호간섭 특성 연구 (A Study for Mutual Interference of LCL Filter Under Parallel Operation of Grid-Connected Inverters)

  • 이강;서정진;차한주
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.75-81
    • /
    • 2021
  • This study analyzes the resonance characteristics caused by the mutual interference between LCL filters and the grid impedance under the parallel operation of the grid-connected inverter using the LCL filter. These characteristics are verified through simulation and experiment. Two inverters are used to connect to the grid in parallel, and the system parameters, including the LCL filter, are set to the same conditions. In the case of inverters running in parallel at the point of common coupling, the presence of grid impedance causes mutual interference between the LCL filters of each inverter, and the deviation of the filter resonance frequency is analyzed to understand the parallel inverter. The correlation between the number of devices and the size of grid impedance is simulated by PSIM and verified by MATLAB. By connecting the real-time digital simulator Typhoon HILS to the DSP 28377 control board, the mutual interference characteristics are tested under the condition of two inverters running in parallel. The experimental and analysis results are the same, indicating the validity of the analysis.

태양전지어레이 순시 출력변동에 의한 외란의 억제기능을 갖는 계통연계형 태양광발전 시스템 (Grid Connected PV System with a Function to Suppress Disturbances caused by Solar-cell Array Instantaneous Output Power Fluctuation)

  • 김홍성;최규하;유권종
    • 태양에너지
    • /
    • 제19권4호
    • /
    • pp.63-69
    • /
    • 1999
  • The conventional grid connected PV(Photovoltaic) system has a unstable output pattern due to its dependence on the weather condition, although solar-cell array averagely has a regular output characteristics to have a peak output nearly at noon. Therefore assuming the high density grid connection in the future, this unstable output pattern can be one of the main reasons to generate power disturbance such as voltage variation, frequency variation and harmonic voltage generation in low voltage distribution line. However general grid connected solar-cell system do not have functions to cope with these disturbances. Therefore this study proposed a advanced type grid connected PV system with functions to suppress output power fluctuation due to solar-cell array output variation and showed the levelling effect of fluctuation due to instantaneous array output variation.

  • PDF

FRETTING WEAR OF A SPRING SUPPORTED TUBE SUBJECTED TO TRANSVERSE VIBRATION

  • Kim, Hyung-Kyu;Yoon, Kyung-Ho;Lee, Young-Ho;Ha, Jae-Wook;Kim, Seock-Sam
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.195-196
    • /
    • 2002
  • Studied is fretting wear behaviour of transversely vibrating tube which is supported by springs and dimples. This simulates the fuel rod fretting due to flow-induced vibration in a nuclear reactor. The contact between spacer grid springs and fuel cladding tubes arc brought into focus in this paper. From the mechanical viewpoint, a concave contact shape of spring is considered to perform a wider distribution of the contact stress. Sliding/impacting experiments are conducted in air at room temperature with the conditions of positive contact force and gap existence to accommodate the mechanical condition between the fuel rod and the grid spring during reactor operation. It is found that wear region is separated and wear volume becomes larger as the supporting condition becomes poorer. Spring and dimple cause similar wear.

  • PDF

A Study on the Variation of the Fretting Wear Mechanisms under Elastically Deformable Contacts

  • Lee, Young-Ho;Kim, Hyung-Kyu
    • KSTLE International Journal
    • /
    • 제10권1_2호
    • /
    • pp.27-32
    • /
    • 2009
  • In this study, fretting wear tests of nuclear fuel rods have been performed by using two kinds of spacer grid springs with a concave and a convex shape in room temperature dry and distilled water conditions. The objectives were to examine the variation of the wear mechanism with increasing fretting cycles and to evaluate the difference of the wear debris detachment behavior at each test environment. From the test results, the wear volume of each spring condition increased with increasing fretting cycles regardless of the test environments. However, the wear rate did not show a regular tendency and apparently changed with increasing fretting cycles. This is because the formation of the wear particle layer and/or the variation of the contact condition between the fuel rod and spring surfaces could affect a critical plastic deformation for detaching the wear debris. Based on the test results, the relationship between the wear behavior of each spring shape and test environment condition, and the variation of the surface characteristics are discussed in detail.

그리드핀을 적용한 작은 세장비를 갖는 자탄의 천음속 공력특성 전산해석 (Numerical simulation of the aerodynamic characteristics on the grid-fin adapted sub-munition with low aspect ratio under transonic condition)

  • 유재헌;김창기;최윤정;임예슬
    • 한국시뮬레이션학회논문지
    • /
    • 제28권2호
    • /
    • pp.23-33
    • /
    • 2019
  • 작은 세장비(aspect ratio)를 갖는 형상의 자탄(sub-munition)은 자유낙하 시 비행 자세 안정성이 불량하고 항력조절이 어렵다. 이러한 문제점을 해결하기 위해 일반적인 비행 날개 대신 그리드핀이라고 불리는 핀을 설계하여 자탄에 적용하였다. 우선 자탄의 기본모델을 설정하고, 해당 모델에 대한 자유낙하 하는 천음속(transonic) 조건에서의 전산해석이 수행되었으며 풍동시험을 통해 전산해석 결과를 검증하였다. 기본모델의 경우 요구되는 수준의 높은 항력은 얻었으나 자세 안정성이 확보되지 않았다. 이를 개선하기 위해 그리드핀의 설계변수 중 하나인 웹 두께(web-thickness)를 변경하여 2종의 핀을 추가로 설계하였으며 해당 설계안에 대한 전산해석을 수행하였다. 수행 결과, 웹 두께가 가장 얇은 조건에서 자세 안정성이 가장 우수하게 확보되었으며 항력계수도 큰 값을 유지하였다. 해석 결과를 기반으로 그리드핀 설계를 완료하고, 자탄에 대한 공력자료를 확보하여 이를 토대로 자탄의 탄도를 예측할 수 있는 기반이 마련되었다. 또한, 그리드핀이 다양한 형태의 비행체와 탄에 사용될 수 있을 것으로 기대된다.