• 제목/요약/키워드: In-Water

검색결과 81,833건 처리시간 0.085초

Managing Groundwater Resources in New Zealand to Account for Environmental Change

  • Davidson, Peter William
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.40-45
    • /
    • 2007
  • Water regulators in New Zealand have recognised the need to adapt water allocation regimes and water permit conditions to reflect the likelihood of lower catchment yield on the east coast from 2030 due to climate change. Water management mechanisms to protect the environment and maintain the reliability of other water users are currently being applied or assessed in Marlborough province. These include seasonal water quota based on spring aquifer status, linking water use to environmental triggers to avoid seawater intrusion or spring depletion; and redefining water permit entitlements to account for recharge variability.

  • PDF

The Practice and Effect of Water Conservation Legislation in China

  • Liu, Dingxiang;Li, Jianguo
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.19-19
    • /
    • 2012
  • After more 60 years' legislative practice of water resources protection, the Chinese government has initially established a legislative system of water resources protection, based on Water Law. From the development course of water resources protection legislation, the paper mainly analyzes the legal framework, main content & management system of water resources protection, and pointed out the improved direction of water resources conservation legislation in China in the future.

  • PDF

Models for drinking water treatment processes

  • Jusic, Suvada;Milasinovic, Zoran;Milisic, Hata;Hadzic, Emina
    • Coupled systems mechanics
    • /
    • 제8권6호
    • /
    • pp.489-500
    • /
    • 2019
  • With drinking water standards becoming more rigorous and increasing demands for additional water quantities, while water resources are becoming more polluted, mathematical models became an important tool to improve water treatment processes performance in the water supply system. Water treatment processes models reflect the knowledge of the processes and they are useful tools for water treatment process optimization, design, operator training for decision making and fundamental research. Unfortunately, in the current practice of drinking-water production and distribution, water treatment processes modeling is not successfully applied. This article presents a review of some existing water treatment processes simulators and the experience of their application and indicating the main weak points of each process. Also, new approaches in the modeling of water treatment are presented and recommendations are given for the work in the future.

수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안 (Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems)

  • 서대근;왕창근
    • 상하수도학회지
    • /
    • 제20권4호
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

Is Liquid Water a Hot Quantum Fluid? Anomalies of Water in Thin Liquid Films and in Biological Systems

  • Yoon, Byoung-Jip
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1211-1214
    • /
    • 2003
  • The anomalies that appear at every multiple of 15 ℃ in the viscosity of a thin liquid film of water and of water near solid interfaces are explained in this paper by comparing the thermal wavelength and molecular free volume of water, and quantum numbers are found. The possibility that these anomalies are related to the preferred and/or lethal temperatures of organisms is considered. The toxicity of heavy water (D₂O) can also be explained with this approach.

서구건축공간에서 물과 수공간의 의미에 관한 연구 (A Study on Meaning of the Water and Water space in western)

  • 이영호;김행신
    • 한국주거학회논문집
    • /
    • 제13권3호
    • /
    • pp.11-20
    • /
    • 2002
  • The purpose of this study is to find out the meanings of water and water spaces in the Western architecture. The meaning of water is investigated by means of mythology and literature studies. It is found that water has ambivalent meanings, i.e. life and death, creation and destruction, chastity and sensuality. The meanings of water spaces in the Western architecture are dramatic, secret and dynamic, and represent publicity, verticality, formality in addition to desire for authority and realization(embodiment) of paradise. Water space is an essential component of beautiful and dynamic spaces and is used to revitalize dreary spaces.

수도권 상수중 유기오염물질의 돌연변이원성 (Mutagenic Activity of Organic Pollutans in Drinking Water in Seoul)

  • 신동천;장재연;조성준;정용
    • Journal of Preventive Medicine and Public Health
    • /
    • 제21권2호
    • /
    • pp.284-294
    • /
    • 1988
  • To measure the mutagenic activity of micro-organic pollutants in drinking water, mutagenicity test was conducted using Salmnella typhimurium TA 98 strain on the water sample taken from three water supply stations and six tap water in Seoul in July and November 1987. The results were as follows : 1. The average amounts of organic matters in raw, treated, and tap water sampled in July were 0.38mg/l, 0.28mg/l, and 0.45mg/l. respectively, and sampled in November were 0.34mg/l, 0.24mg/l, and 0.22mg/l, respectively. The amount of organic matters of tap water sampled in November did not increase while that of tap water sampled in July increased compare to those of raw or treated water. 2. The amount of organic matters is the highest in neutral fraction compare to acidic and basic fractions. 3. In the five out of six tap water and raw water of Paldang and Kuui station sampled in July, the mutagenicity ratios were greater then two (both direct and indirect mutagenicity). 4. In the three out of six tap water and raw and treated water of Kuui station sampled in November, the mutagenicity ratios were greater than two. 5. While mutagenic activities were low in acidic and basic fraction, they were high in neutral fraction. The samples which had high mutagenic acitivity in the total amount also showed high mutagenic activity in neutral fraction. 6. While mutagenic acitivity was decreased after the treatement of water, it was increased in tap water as the distance from the water supply station increases.

  • PDF

수분환경이 다른 서식지에서 자란 Impatiens pallida 의 두 개체군간 수분에 대한 경쟁 (Competition for Water in Two Populations of Impatiens pallida (Balsaminaceae) from Contrasting Water Environments)

  • Yang, Hyo-Sik;James B. McGraw
    • The Korean Journal of Ecology
    • /
    • 제19권2호
    • /
    • pp.165-178
    • /
    • 1996
  • We investigated the role of competition in adaptation to varying water availability levels for two ecotypically-differentiated populations of Impatiens pallida found naturally in low- vs. high-water environments. In a greenhouse experiment, seedlings were grown in pure cultures at two densities (n=1 and 2 plants per pot) and in mixed cultures (n=2) under low-, medium- and high-water treatments. The two populations were shown to be genetically distinct across the range of environmental conditions in the greenhouse experiment, confirming previous findings. The two populations had similar morphological responses to density and water availability in pure cultures and mixtures, but the population from the high-water environment showed a greater growth response to high water availability than did the population from the low-water environment and the difference in growth between the two populations decreased from the high-water to low-water treatment. Relative competitive ability of two populations were compared under three different water treatments and two densities. Differential response to watering treatment and density were not reflected in a difference in relative competitive ability. Relative yield totals were significantly greater than 1 overall. The niche differentiation suggested by RYTs>1 may be responsible for the lack of differential competitive effects observed for populations in the three vatering treatments.

  • PDF

신규 댐 건설 전후의 수질변동 분석: 영주댐 상류유역을 중심으로 (Analysis of Water Quality Characteristics According to Short-term Fluctuation of Water Level in the New Dam: Focused on the Upstream Watershed of Yeongju Multipurpose Dam)

  • 이새로미;박재로;황태문;안창혁
    • 한국물환경학회지
    • /
    • 제36권5호
    • /
    • pp.431-444
    • /
    • 2020
  • The relationship between dam construction and water quality has recently come to be considered an important issue. A dam is a physical factor which causes changes to the river system around it. Considering these points, this study was conducted to obtain basic data by analyzing the relationship between water level fluctuations and water quality parameters in the short-term. In terms of methodology, the new construction of the Yeongju Dam (M5) in 2016 was divided into Stage 1 as the lotic system and Stage 2 as the lentic system, with four years in each period, and the water level fluctuations and water quality were analyzed using official data. As a result of this study, M5, a stagnant area in which organic matter and nutrients accumulate, was found to be an important factor in water quality management. In addition, the water level changed rapidly (0.9±0.2 m → 10.9±7.1 m) as the river environment condition was converted from the lotic system to the lentic system. In addition, water quality parameters such as BOD, COD, TOC, and Chl-a significantly changed in the short-term. Further, since the transport of organic matter and nutrients occurred well in the lotic system, sedimentation was expected to be dominant in the lentic system. Therefore, it was determined that when the river flow is blocked, autochthonous organic matter is an important factor for long-term water quality management in the future. This process can increase the trophic state of the water body. As a result of this study, the TSIKO value was converted from mesotrophic in Stage 1 to eutrophic in Stage 2. Eventually, short-term changes in the river environment will affect not only changes in water level but also changes in water quality. Thus, a comprehensive and strategic approach is needed for long-term water quality management in the future.

Antibacterial Effect of Electrolyzed Water on Oral Bacteria

  • Lee Sung-Hoon;Choi Bong-Kyu
    • Journal of Microbiology
    • /
    • 제44권4호
    • /
    • pp.417-422
    • /
    • 2006
  • This study investigated the antibacterial effect of electrolyzed water on oral bacteria both in vitro and in vivo. Tap water was electrolyzed in a water vessel using platinum cell technology. The electrolyzed tap water (called Puri-water) was put in contact with five major periodontopathogens or toothbrushes contaminated with these bacteria for 30 sec. In addition, Puri-water was used as a mouthwash for 30 sec in 16 subjects and the antibacterial effect on salivary bacteria was evaluated. Puri-water significantly reduced the growth of all periodontopathogens in culture and on toothbrushes, and that of aerobic and anaerobic bacteria in saliva, when compared to the effect of tap water. It also significantly reduced mutans streptococci growing on mitis salivarius-bacitracin agar. Our results demonstrate that the electrolyzed tap water is effective as a mouthwash and for toothbrush disinfection.