• Title/Summary/Keyword: In-Water

Search Result 81,833, Processing Time 0.081 seconds

Evaluation of Stream Water Quality to Select Target Indicators for the Management of Total Maximum Daily Loads (수질오염총량관리 대상물질 선정을 위한 하천수질 평가)

  • Park, Jun Dae;Park, Jae Hong;Oh, Seung Young;Lee, Jae Kwan
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.630-640
    • /
    • 2013
  • It is one of the most critical steps identifying impaired waterbodies exactly in the selection of target water quality indicators for the management of Total Maximum Daily Loads (TMDLs). Excess ratio and excess level were applied and analyzed by the stream zone basis in order to evaluate water impairment for Nakdong, Geum, Youngsan and Seomjin rivers. Each river basin was divided into stream zones in the light of its watershed and waterbody characteristics. Selected water quality parameters discussed in this study were pH, DO, BOD, COD, SS, T-P, T-Coli and F-Coli. The excess ratios of the water quality parameters were used to discriminate water bodies that did not meet water quality standards. The excess levels were used to classify the degradation of water quality. The excess ratios and the excess levels to the water quality criteria of the medium influence areas were used for each stream zone. The results indicate that the excess ratios and the excess levels are varied on the stream zone in each river basin. Three parameters, pH, DO and SS, met water quality standards in all stream zones. The other five parameters indicated very high excess ratios in most waterbodies, and especially T-P and T-Coli revealed to be very high excess levels in some waterbodies. These parameters could be considered as major target indicators for the management of TMDLs.

Leakage detection and management in water distribution systems

  • Sangroula, Uchit;Gnawali, Kapil;Koo, KangMin;Han, KukHeon;Yum, KyungTaek
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.160-160
    • /
    • 2019
  • Water is a limited source that needs to be properly managed and distributed to the ever-growing population of the world. Rapid urbanization and development have increased the overall water demand of the world drastically. However, there is loss of billions of liters of water every year due to leakages in water distribution systems. Such water loss means significant financial loss for the utilities as well. World bank estimates a loss of $14 billion annually from wasted water. To address these issues and for the development of efficient and reliable leakage management techniques, high efforts have been made by the researchers and engineers. Over the past decade, various techniques and technologies have been developed for leakage management and leak detection. These include ideas such as pressure management in water distribution networks, use of Advanced Metering Infrastructure, use of machine learning algorithms, etc. For leakage detection, techniques such as acoustic technique, and in recent yeats transient test-based techniques have become popular. Smart Water Grid uses two-way real time network monitoring by utilizing sensors and devices in the water distribution system. Hence, valuable real time data of the water distribution network can be collected. Best results and outcomes may be produced by proper utilization of the collected data in unison with advanced detection and management techniques. Long term reduction in Non Revenue Water can be achieved by detecting, localizing and repairing leakages as quickly and as efficiently as possible. However, there are still numerous challenges to be met and future research works to be conducted in this field.

  • PDF

Establishment of Target Water Quality for TOC of Total Water Load Management System (오염총량관리제도의 TOC 목표수질 설정 방안)

  • Kim, Yong Sam;Lee, Eun Jeong
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.6
    • /
    • pp.520-538
    • /
    • 2019
  • In this study, it was proposed that a method of setting the target water quality for TOC using the watershed model and the load duration curves to manage non-biodegradable organics in the total water load management system. To simulate runoff and water quality of the watershed, the HSPF model is used which is appropriate for urban and rural areas. Additionally, the load duration curve is used to reflect the variable water quality correlated with various river flow rates in preparing the TMDL plans in the U.S. First, the model was constructed by inputting the loads calculated from the pollutant sources in 2015. After the calibration and verification process, the water quality by flow conditions was analyzed from the BOD and TOC simulation results. When the BOD achieved the target water quality by inputting the target year loads for 2020, the median and average values of TOC were proposed for the target water quality. The provisional method of TOC target water quality for the management of non-biodegradable organics, which is one of the challenges of the total water load management system, was considered. In the future, it is expected to be used as basic data for the conversion of BOD into TOC in the total water load management system.

Characteristics of Water Surface Discharge due to Water Conductivity (수증 전도도 변화에 따른 수표면 방전의 특성)

  • 박승록;김진규;김형표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.44-48
    • /
    • 2004
  • A silent type ozone generator using water surface electrode was proposed. And it was investigated experimentally that a variation of water conductivity affected to water surface discharge. Important factors affecting to water surface discharge are ions in discharge space and ions and polarized molecules in water and so on. In this study, It was intended to change the characteristics of discharge by controlling the number of ions in water. The number of ions in water could be controlled by changing the water conductivity. Water conductivity was controlled by quantity of inserted NaCl to distilled water. At this time, current-voltage characteristics and characteristics of ozone generation quantity were investigated in each case. As a result, when NaCl was inserted in distilled water, more stable discharge was generated. As the quantity of NaCl was increased, discharge starting voltage could be lowered.

On the Distribution of Water Temperature in the Warm Water Pool. -On the Wudu Warm Water Pool- (온수지에서의 수온분포에 관한 연구 -우두온수지를 중심으로-)

  • 연규석;최예환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.121-126
    • /
    • 1979
  • The objective of this study was to grasp the condition of the distribution of water temperature in the warm water pool, and these observations were performed in Wudu warm water pool located at Wodu-Dong in Chuncheon. The results summarized in this study are as follows; 1. The horizontal distribution charts of water temperature at each depth of points were shown as Fig. 3, Fig. 4, and Fig. 5, respectively. In consequence of the observation, the condition of warm water was stagnant in the coner of warm water pool. As the result, it was found out that stagnant condition was the heaviest at water surface (depth; 0.05m), more heavier at middle depth (depth; 0.55m) and some heavy at bottom of the pool (depth; 1.10m). 2. The vertical water temperature change was shown as Fig. 6, and the mean water temperature of water surface (depth;0.05m) was higher about $2.2{\sim}3.3^{\circ}C$ than bottom water temperature. 3. Therefore, it was required to device such structures as form of broad cannels or overflow diversion weirs to mingle with top and bottom water.

  • PDF

A Study on the Performance Evaluation of Recirculation System for Individual Hot Water Supply System in Residential Buildings (주거건물의 개별급탕방식 환탕배관 적용에 따른 급탕성능 평가에 관한 연구)

  • Cha, Min-Chul;Yeo, Myoung-Souk;Seok, Ho-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.857-864
    • /
    • 2007
  • In the current residential building, hot water supply system consumes the second largest energy in order to make the thermal comport condition of residential space. The more residential environment improves the more the demand for hot water and water consumption is increasing gradually. So this study examines the possibility of applying the recirculation for individual hot water supply system compared with the existing method for waiting time for hot water, wasted water and energy consumption. The results are as follows. (1) In case of recirculation system method the waiting time for hot water can be reduced up to $69\sim85%$ in spring and fall period and so dose up to $77\sim85%$ in winter period. (2) The total wasted water has a little change compared with the existing method which can make the total wasted water reduced about $77\sim86%$. (3) The efficiency of hot water supply system can be improved, if the method which blocks the inflow of cold water is applied, when return pump is operated to recirculate hot water in recirculation system.

Distribution of Acanthamoeba spp. in Raw Water and Water Treatment Process (상수원수 및 정수처리공정별 가시아메바 분포특성에 관한 연구)

  • Jung, Eun-Young;Jung, Mi-Eun;Park, Hong-Gi;Jung, Jong-Moon;Rho, Jae-Sun;Ryu, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1121-1127
    • /
    • 2008
  • The free-living amoeba and Acanthamoeba sp. are widely distributed in fresh water, soil, air and dust in the world. We studied distribution of amoeba from low Nakdong River(Mulgum and Maeri) and removal efficiency in water treatment process of Busan metropolitan city. During this investigation, water quality showed pH $7.4{\sim}9.6({\pm}1.1)$, water temperature $2.0{\sim}29.0({\pm}17)^{\circ}C$, turbidity $4.8{\sim}27.4({\pm}11.0)$ NTU, chlorophyll-a $10.3{\sim}109.0({\pm}44.3)\;mg/m^{3}$, BOD $1.7\sim4.9({\pm}2.6)$ mg/L, COD $3.1\sim-6.9({\pm}5.0)$ mg/L and total coliform $17\sim920({\pm}200.5)$ MPN/100 mL. The free-living amoeba were detected highly than Acanthamoeba sp., 11 out of 22 in raw water samples were positive (50%) for Acanthamoeba sp. from February 2005 to December 2005. The seasonal characteristics of tree-living amoeba and Acanthamoeba sp. in raw water were mainly distributed through the spring to the early fall. When tree-living amoeba and Acanthamoeba sp. were passed through the water treatment of pilot-plant, approximately 80% was sure to be removed through pre-ozonation, sedimentation, send filtration. 100% was removed after post-ozonation process. All of the isolated amoebas from Nakdong River were Acanthamoeba sp. AC311 18S ribosomal RNA gene with 98% nucleotide sequence homology.

Water projects and technologies in Asia: Historical perspective

  • Hyoseop Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.24-24
    • /
    • 2023
  • This presentation highlights the IAHR book, recently published last April, of which the author is the editor-in-chief, on the historical water projects and traditional water technologies of international interest in the Asian region, addressing information on past water projects (mostly before the 20th century) in the regions that are technically and culturally of interest and educationally valuable. The book explores historical water projects in these regions, presenting technologies used at the time, including calculation and forecasting methods, measurement, material, labor, methodologies, and even water culture. Through this book, it is expected that the old Asian wisdom of "reviewing the old and learning the new" would be realized to a certain extent in modern planning and practice of water projects. The book comprises a lead article that the presenter authored and five Parts representing China, Japan, Korea, South Asia, and Southeast Asia, respectively, followed by an invited one from Uzbekistan. Throughout the book, it is found that historically the Asian monsoon, affecting the Indian subcontinent and Southeast and East Asian regions, induced rice cultivation. It fundamentally needs proper irrigation systems, including reservoirs (dams) and canals, water wheels, and even rain gauges. Flood risks have been more common in Asia than Europe under this climate condition, as recognized in history. To utilize and sometimes overcome these climate conditions, people built and managed many historical and grandiose water projects and invented and used localized but sophisticated water-related technologies in the Asian region.

  • PDF

Water Resources Planning for the 2S River Basin in Viet Nam

  • Ko, Ick Hwan;Choi, Byung-Man;Kim, Jeong-kon;Pi, Wan-Seop;Shin, Jae-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.78-78
    • /
    • 2020
  • The Se San and Srepok river basins (2S) are the two major tributaries of the Mekong River, both of which originate in the territory of Viet Nam and flow to Cambodia to meet at Stung treng with the Sekong river (originating in Lao PDR) to form the 3S river basin before joining the Mekong mainstream. In the territory of Viet Nam, the 2S river basins are located in the Central Highlands including 5 provinces, arranged by geographical location from north to south namely Kon Tum, Gia Lai, Dak Lak, Dak Nong and Lam Dong. This is a region with a very important strategic position in terms of economy, politics and defense for the whole country with many potential advantages for economic development. However, the limited and vulnerable basin water resources are under the pressure of socio-economic development in line with increasing water demands for various sectors. In order to overcome the water management challenges, a long-term water resources planning has conducted to support the 2S River Basin Committee (RBC) in effective planning and operation as part of the WB Mekong-Integrated Water Resources Management (IWRM) Project. This paper introduces the outline and progress of the river basin planning using analytical DSS toolkits to analyze, evaluate and formulate the planning options.

  • PDF

Variation of Cardiac Output and Blood Pleasure after Flooding Water into Lungs (폐 침수시의 심장 박출량과 혈압의 변동)

  • Cho, Sung-Doo;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 1967
  • Cold $(0^{\circ}C)$ or warm $(25^{\circ}C)$ fresh and sea water were flooded into the lungs of rabbits through tracheal canule. Respiratory arrest ensued in 19.5 minutes in the warm fresh water flooded rabbits and was the longest survival time among the experimental groups. The survival times in the other groups were: 2.32 minutes in cold fresh water group, 2.75 minutes in .warm sea water group, and 4.57 minutes in cold sea water group. Cardiac output was measured by means of T-1824 dilution technique after 2 or 3 minutes of flooding in 27 rabbits. Blood pressure was observed by mercury manometer throughout the survival time in 40 rabbits. The following results were obtained. 1. Cardiac output in the warm fresh water flooded and sea water flooded animal was smaller than that of control rabbits. In the cold fresh water flooded animal cardiac output was greater than that of the control animal. 2. Time constants of T-1824 dilution curve of experimental group were elongated than the normal curve. 3. Central blood volume showed an increase in the fresh water group, a decrease in cold sea water group and no change in warm sea water group. 4. In all of the experimental groups arterial blood Pressure showed an abrupt and great variations after flooding of lungs and lasted about 30 seconds. Thereafter, arterial pressure remained at a plateau level until the sudden fall to zero and this was almost coincided with the time of respiratory arrest. The Plateau level of arterial Pressure in fresh water group was about 10 mmHg higher than the control value, and it was lower than the control value in warm sea water group. In cold sea water group the plateau was made up by fluctuations around the control value. 5. Osmosis of water through the lung alveolar membrane occured in all animals. Fresh water caused hemodilution and sea water caused hemoconcentration. 6. In sea water flooded animal more volume of water was recovered through the tracheal canule than the volume injected into trachea. This was interpreted as the consequence of the shift of water from plasma to alveolar sac. 7. Relative freight of lung was greater in fresh water group than sea water group. In all animal lung edema ensued. 8. The mechanisms of cardiac output variations were discussed.

  • PDF