• 제목/요약/키워드: In-Water

검색결과 81,833건 처리시간 0.08초

원수열원 히트펌프 축열시스템의 동절기 성능분석 (Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank)

  • 조용;이동근
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF

농촌수자원 스마트 물관리를 활용한 농업용수의 관개효율 평가 (Assessment of Irrigation Efficiencies using Smarter Water Management)

  • 남원호;최진용;홍은미;김진택
    • 한국농공학회논문집
    • /
    • 제55권4호
    • /
    • pp.45-53
    • /
    • 2013
  • Efficient water operation and management of an irrigation system plays an important element in the sustainability of irrigated agriculture. An agricultural water is delivered in many open canals of irrigation delivery system by reservoirs. The poor water distribution and management in an irrigation system is a major factor leading to low water efficiency. It is necessary to compare the estimated irrigation demands with the actual water supplies for decision making to maintain the water supply according to demand strategy. Smarter water management, new technologies and improvement of water management system, is essential to solve the problem of water efficiency and availability. In this paper, the irrigation efficiencies according to water delivery performance indicator were measured with automatic water gauge at irrigation canals, and calculated from spatial and temporal distribution of water supply for the lack of planning in water delivery. The analysis of results are obtain an insight into possible improvement methods to develop canal water management policies that enable irrigation planners to optimally manage scarce available water resources.

동위원소를 이용한 제주지역 수질원에 관한 연구 (Environmental Isotope-Aided Studies on Water REsources in the Region of Cheju)

  • 안종성;한정상
    • 물과 미래
    • /
    • 제17권2호
    • /
    • pp.72-79
    • /
    • 1984
  • This investagation was carried out by analyzing water types and measuring the environmetal isotopes (tritium and deuterium) for development of water resources and protection of ground waters from sea water intrusion. The water sample were taken monthly from April to June, 1983 from sixteen sites in the Cheju metropolitan area; three sea, three spring, and ten ground waters. The ground water in the midwest area of the city contained 20 TU of tritium and-46 per mille of deuterium, classified as the $NaHCO_3$ type of ground water, generally deep seated. The spring water and ground water in the southern part of the city contained 15 to of tritium and-39 per mile of deuterium, and appeared to the $CaHCO_3$ type of shallow ground water, easily affected 표 precipitation. The results of tritium and deuterium analyses showed that the ground water in the coastal area were not affected by sea water intrusion, although they changed from $NaHCO_3$ or $CaHCO_3$ type to NaCl type in May and June. It is concluded that the high Na and Cl content in those ground waters might come from municipal sewage. The sea water in the Yong-duam area was influenced by sping water.

  • PDF

시스템 다이내믹스법을 이용한 서울특별시의 장기 물수요예측 (Forecasting the Long-term Water Demand Using System Dynamics in Seoul)

  • 김신걸;변신숙;김영상;구자용
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.187-196
    • /
    • 2006
  • Forecasting the long-term water demand is important in the plan of water supply system because the location and capacity of water facilities are decided according to it. To forecast the long-term water demand, the existing method based on lpcd and population has been usually used. But, these days the trend among the variation of water demand has been disappeared, so expressing other variation of it is needed to forecast correct water demand. To accomplish it, we introduced the System Dynamics method to consider total connections of water demand factor. Firstly, the factors connected with water demand were divided into three sectors(water demand, industry, and population sectors), and the connections of factors were set with multiple regression model. And it was compared to existing method. The results are as followings. The correlation efficients are 0.330 in existing model and 0.960 in SD model and MAE are 3.96% in existing model and 1.68% in SD model. So, it is proved that SD model is superior to the existing model. To forecast the long-term water demand, scenarios were made with variations of employment condition, economic condition and consumer price indexes and forecasted water demands in 2012. After all scenarios were performed, the results showed that it was not needed to increase the water supply ability in Seoul.

생활 및 공업용수 물이용 패턴을 고려한 물수급 전망 비교 및 고찰 (Evaluation and comparison of water balance and budget forecasts considering the domestic and industrial water usage pattern)

  • 오지환;임동진;김인규;신정범;류지성
    • 한국수자원학회논문집
    • /
    • 제55권11호
    • /
    • pp.941-953
    • /
    • 2022
  • 본 연구에서는 한강 권역의 포함된 65개 지자체를 대상으로 5년간 월별 물이용량 자료를 수집, 분석하여 월 단위의 대표적인 생공용수 물이용 패턴을 도출하고, 물수급 네트워크 모델(MODSIM)과 기초자료를 이용하여 물이용 패턴을 반영함에 따른 유역 내 발생 가능한 물부족량의 차이를 비교하였다. 분석 결과, 특정 시기별 물이용 주기성을 파악하고, 월별 일정 비율 대비-3.120%~+4.322%의 증감 폭이 나타남을 확인하였다. 이를 물수급 모델에 적용할 경우, 28개 중권역 중 17개 유역에서 물부족량의 변화가 나타났고, 연간 동일한 수요량임에도 불구하고, 시기별 수요량의 비율을 적용함에 따라 최대 생공용수 부족량은 기존대비 약 8.0% 수준으로 감소할 것으로 분석되었다. 장래 기후변화, 사회적, 지역적 특성이 반영된 물이용 패턴에 대한 예측 연구와 연계한다면, 더욱 현실감 있는 물수급 전망과 신뢰도 높은 국가수자원계획 수립이 가능할 것이라고 판단된다.

Vulnerability AssessmentunderClimateChange and National Water Management Strategy

  • Koontanakulvong, Sucharit;Suthinon, Pongsak
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.204-204
    • /
    • 2016
  • Thailand had set the National Water Management Strategy which covered main six areas in the next 12 years, i.e., by priority: (1) water for household, (2) water for agricultural and industrial production, (3) water for flood and drought management, (4) water for quality issue, (5) water from forest conservation and soil erosion protection, (6) water resources management. However due to the climate change impact, there is a question for all strategies is whether to complete this mission under future climate change. If the impact affects our target, we have to clarify how to mitigate or to adapt with it. Vulnerability assessment was conducted under the framework of ADB's (with the parameters of exposure, sensitivity and adaptive capacity) and the assessments were classified into groups due to their different characteristic and the framework of the National Water Management Strategy, i.e., water supply (rural and urban), water for development (agriculture and others), water disasters (floods (flash, overflow), drought, water quality). The assessments identified the parameters concerned and weight factors used for each groups via expert group discussions and by using GIS mapping technology, the vulnerability maps were produced. The maps were verified with present water situation data (floods, drought, water quality). From the analysis result of this water resources management strategy, we found that 30% of all projects face the big impacts, 40% with low impact, and 30% for no impact. It is clear that water-related agencies have to carefully take care approximately 70% of future projects to meet water resources management strategy. It is recommended that additional issues should be addressed to mitigate the impact from climate risk on water resource management of the country, i.e., water resources management under new risk based on development scenarios, relationship with area-based problems, priority definition by viewpoints of risk, vulnerability (impact and occurrence probability in past and future), water management system in emergency case and water reserve system, use of information, knowledge and technology in management, network cooperation and exchange of experiences, knowledge, technique for sustainable development with mitigation and adaptation, education and communication systems in risk, new impact, and emergency-reserve system. These issues will be described and discussed.

  • PDF

농업용수 물절약에 대한 농업인 의식 및 행동 조사 - 포항·영덕지역 수리시설감시원을 대상으로 - (Survey of Farmers' Perception and Behavior for Agricultural Water Saving - Applying to Irrigation Facility Monitors in Pohang and Yeongdeok Areas -)

  • 이슬기;최경숙
    • 농촌계획
    • /
    • 제26권3호
    • /
    • pp.39-47
    • /
    • 2020
  • While agricultural water has been declared free in Korea to ensure access to these limited resource since the year 2000, farmers have however developed lackadaisical behavior towards water saving leading to its scarcity. To overcome this problem, a variety of experience-oriented education model was developed for farmers to promote the adoption of water conservation, and preventive measure against the drought impacts. In this study, farmers' awareness and their attitudinal behavior of agricultural water savings were investigated. The monitoring of water supply structure and the repair facilities in Pohang and Yeongdeok areas were conducted. The field visits and behavioral surveys showed a high degree of over-use and illegal water withdrawals by the farmers due to poor water-saving and management practices. We found that most of the KRC employees strongly admitted the necessity of water-saving education. On the other hand, the farmers showed good interest in the implementation of water-saving awareness through education. Besides this, most farmers agreed to adopt water-saving practices in the fields. Farmers also acknowledged the recklessness of water use was due to the aging of waterways, poor water management, and illegal water consumption. The majority of the farmers responded against imposing the water-use tariffs. However, there was a low response to paying the water-use charge. Aging agricultural facilities and the lack of institutional penalties or incentives were the major obstacles in achieving efficient water-saving. Considering the current drought frequency, urgent water-saving education of farmers was deemed necessary to prepare the farming community against the water shortages. Based on the results of this study, we have to identify the irrigation practices of farmers and provide water-saving education to enforce more efficient use and management of agricultural water.

음용수의 변이원성에 관한 조사연구 (Study on the Mutagenicity of Drinking Water)

  • 박지인;유춘만;위인선
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.68-73
    • /
    • 1998
  • This is a study on the risk assessment of drinking water using mutagenicity testing. The tests have been carried with the raw water, treated water, and drinking water (tap water) in Kwangju and Mokpo areas. The Ames preincubation test was carried concentrating samples using by Sep-Pak PLUS cartriges in Salmonella typhimurium TA100 and TA98. The samples were tested with several chemical water quality analysis. The THMs have not been measured in raw water, but measured treated water and tap water at a value of 7.135-12.473 $\mu$g/l. It was observed that the number of revertants colonies increased in treated water and tap water on TA100 without S9 and showed weak mutagenicity on TA98 without S9. Indirect mutation was not seen in TA100 and TA98 with S9. The results indicated that formed substances of treatment process's of water that increased mutagenicity.

  • PDF

목포항 수질의 계절적 변화 특성 I. 물리 환경과 유기 오염 (The Characteristics of Seasonal Variations of Water Quality in Mokpo Harbour 1. Physical Environment and Organic Pollution)

  • 김광수
    • 해양환경안전학회지
    • /
    • 제5권2호
    • /
    • pp.57-65
    • /
    • 1999
  • The in situ observations and the seawater analyses were conducted at all seasons from July 1996 to April 1999 for the purpose of describing the characteristics of seasonal variations of water quality in Mokpo harbour, Korea. Vertical stratification started to be formed in water column in spring, developed in summer and disappeared in fall. In summer, vertical density distribution of water column was found to be in stable structure with lower temperature and higher salinity of bottom water, and the vertical mixing of water between surface and bottom layers was restricted. In winter, however, surface water was found to be similar to bottom water in temperature and salinity, and water column was in unstable structure and in well-mixed condition between surface and bottom waters. The saturation percentage of dissolved oxygen(DO) in bottom water of inner part of Mokpo harbour at all seasons was shown to be decreased to the third grade or under the third grade of Korean standards of seawater quality. In particular, dissolved oxygen was oversaturated in surface water and undersaturated in bottom water in summer, due to stratification and organic pollution. The difference of DO concentration between surface and bottom waters was found to be greater in spring and summer than in fall and winter, due to stratification and photosynthesis of phytoplankton. The concentrations of chemical oxygen demand(COD) over the entire waters of Mokpo harbour were found to fluctuate from below the third grade to the first grade of Korean standards through all seasons and COD concentrations of same seasons were shown to be different year after year. In particular, in view of COD, the annual average seawater quality of Mokpo harbour was evaluated to be in third grade of Korean standards, due to organic pollution. The average COD of surface water was greater than that of bottom water in spring and summer, due to the autochthonous COD caused by production of phytoplankton in surface waters, while the average COD of surface water was similar to that of bottom water in fall and winter, due to the vertical mixing of water between surface and bottom layers.

  • PDF

서울市 一部 水道栓水中 重金屬에 관한 調査硏究 (A Study on Heavy Metals at the Consumer s Tap in Seoul)

  • Lee, Byung Mu
    • 한국환경보건학회지
    • /
    • 제10권2호
    • /
    • pp.41-51
    • /
    • 1984
  • This study was performed using samples collected at Myungryundong and at Reservoirs. The purpose of this study was to investigate the differences of water quality between tap and raw water, and to analyse drinking water quality by Fe, Zn from corroded galvanized steel pipe. Results were as follows 1. The older the pipe was, the higher the concentration of Ferrum and Zinc was (t-test : p<0.05). Ferrum and Zinc also exceeded the limits in the older galvanized steel pipe. I think that this comes from the corrosion of pipe. 2. Mercury, Arsenic, Cadmium, Lead, Chomium, Argentum and Aurum not detected in raw water were not detected in tap water. Cobalt, Bismuth and Molybudenum detected in raw water were not detected in tap water. I think that this comes from the quality of raw water, the result of water treatment and the improbability of detection of above metals in water delivery system. 3. Silicon measured 2.4698ppm in raw water, but it ranged from 0.4769ppm to 1.982 ppm in tap water. Manganese measured 0.0638ppm in raw water, but it ranged from 0.0026ppm to 0.0198ppm in 17cases(31%) out of 55samples in tap water. I think that this comes from the water treatment. 4. Aluminium not detected in raw water was found in 17 cases (31%) out of the samples (55cases). It may be considered as the use of coagulants $Al_2(SO_4)_3$. $18H_2O$ and PAC (Poly Aluminium Chloride). The concentration of copper in tap water was much higher in 2 cases(3.6%) out of the samples(55) than that of copper in raw water. I think that this may come from the use of ${CuSO}_4$, the preventive of algae growth, and the result of chlorination, but further study must be necoessary to support the proof.

  • PDF