• 제목/요약/키워드: In vivo imaging system

검색결과 100건 처리시간 0.032초

Synthesis of a Novel Near-Infrared Fluorescent Dye: Applications for Fluorescence Imaging in Living Cells and Animals

  • Chen, Tongbin;Lai, Yijun;Huang, Suisheng
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권10호
    • /
    • pp.2937-2941
    • /
    • 2013
  • Fluorescence imaging is considered as one of the most powerful techniques for monitoring biomolecule activities in living systems. Near-infrared (NIR) light is advantageous for minimum photodamage, deep tissue penetration, and minimum background autofluorescence interference. Herein, we have developed a new NIR fluorescent dye, namely, RB-1, based on the Rhodamine B scaffold. RB-1 exhibits excellent photophysical properties including large absorption extinction coefficients, high fluorescence quantum yields, and high photostability. In particular, RB-1 displays both absorption and emission in the NIR region of the "biological window" (650-900 nm) for imaging in biological samples. RB-1 shows absorption maximum at 614 nm (500-725 nm) and emission maximum at 712 nm (650-825 nm) in ethanol, which is superior to those of traditional rhodamine B in the selected spectral region. Furthermore, applications of RB-1 for fluorescence imaging in living cells and small animals were investigated using confocal fluorescence microscopy and in vivo imaging system with a high signal-to-noise ratio (SNR = 10.1).

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.

Enhanced Strain Imaging Using Quality Measure

  • Jeong, Mok-Kun;Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제27권3E호
    • /
    • pp.84-94
    • /
    • 2008
  • Displacement estimation is a crucial step in ultrasonic strain imaging. The displacement between a pre- and postcompression signal in the current data window is estimated by first shifting the postcompression signal by the displacement obtained in the previous data window to reduce their decorrelation and then determining the remaining part of the displacement through autocorrelation and conversion of phase difference into time delay. However, since strain image quality tends to vary with the amount of compression applied, we propose two new methods for enhancing strain image quality, i.e., displacement normalization and adaptive persistence. Both in vitro and in vivo experiments are carried out to acquire ultrasound data and produce strain images in real time under the application of quasi static compression. The experimental results demonstrate that the methods are quite effective in improving strain image quality and thus can be applied to implementing an ultrasound elasticity imaging system that operates in real time.

Preclinical evaluation using functional SPECT imaging of 123I-metaiodobenzylguanidine (mIBG) for adrenal medulla in normal mice

  • Yiseul Choi;Hye Kyung Chung;Sang Keun Woo;Kyo Chul Lee;Seowon Kang;Seowon Kang;Joo Hyun Kang;Iljung Lee
    • 대한방사성의약품학회지
    • /
    • 제7권2호
    • /
    • pp.93-98
    • /
    • 2021
  • meta-iodobenzylguanidine is one of the norepinephrine analogs and reuptakes together with norepinephrine with norepinephrine transporter. The radioiodinated ligand, 123I-meta-iodobenzylguanidine, is the most widely used for single photon emission computed tomography imaging to diagnose functional abnormalities and tumors of the sympathetic nervous system. In this study, we performed cellular uptake studies of 123I-meta-iodobenzylguanidine in positive- and negative-norepinephrine transporter cells in vitro to verify the uptake activity for norepinephrine transporter. After 123I-meta-iodobenzylguanidine was injected via a tail vein into normal mice, Single photon emission computed tomography/computed tomography images were acquired at 1 h, 4 h, and 24 h post-injection, and quantified the distribution in each organ including the adrenal medulla as a norepinephrine transporter expressing organ. In vitro cell study showed that 123I-meta-iodobenzylguanidine specifically uptaked via norepinephrine transporter, and significant uptake of 123I-meta-iodobenzylguanidine in the adrenal medulla in vivo single photon emission computed tomography images. These results demonstrated that single photon emission computed tomography imaging with 123I-meta-iodobenzylguanidine were able to quantify the biodistribution in vivo in the adrenal medulla in normal mice.

Microscopic Imaging of Articular Cartilage using Polarization-Sensitive Optical Coherence Tomography

  • Lee Sang-Won;Oh Jung-Taek;Kim Beop-Min
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권1호
    • /
    • pp.37-42
    • /
    • 2005
  • We construct and test the polarization-sensitive optical coherence tomography (PS-OCT) system for imaging porcine and human articular cartilages. PS-OCT is a new imaging technology that provides information regarding not only the tissue structures but tissue components that show birefringence such as collagen. In this study, we measure the cartilage thickness of the porcine joint and the phase retardation due to collagen birefringence. Also, we demonstrate that changes of the collagen fiber orientation could be detected by the PS-OCT system. Finally, differences between normal and damaged human articular cartilage are observed using the PS-OCT system, which is then compared with the regular histology pictures. As a result, the PS-OCT system is proven to be effective for diagnosis of the pathology related to the cartilage. In the future, this technology may be used for discrimination of the collagen types. When combined with endoscope technologies, the PS-OCT images may become a useful tool for in vivo tissue testing.

Poloxamer 407 Hydrogels for Intravesical Instillation to Mouse Bladder: Gel-Forming Capacity and Retention Performance

  • Kim, Sang Hyun;Kim, Sung Rae;Yoon, Ho Yub;Chang, In Ho;Whang, Young Mi;Cho, Min Ji;Kim, Myeong Joo;Kim, Soo Yeon;Lee, Sang Jin;Choi, Young Wook
    • 대한비뇨기종양학회지
    • /
    • 제15권3호
    • /
    • pp.178-186
    • /
    • 2017
  • Purpose: Poloxamer 407 (P407) thermo-sensitive hydrogel formulations were developed to enhance the retention time in the urinary bladder after intravesical instillation. Materials and Methods: P407 hydrogels (P407Gels) containing 0.2 w/w% fluorescein isothiocyanate dextran (FD, MW 4 kDa) as a fluorescent probe were prepared by the cold method with different concentrations of the polymer (20, 25, and 30 w/w%). The gel-forming capacities were characterized in terms of gelation temperature (G-Temp), gelation time (G-Time), and gel duration (G-Dur). Homogenous dispersion of the probe throughout the hydrogel was observed by using fluorescence microscopy. The in vitro bladder simulation model was established to evaluate the retention and drug release properties. P407Gels in the solution state were administered to nude mice via urinary instillation, and the in vivo retention behavior of P407Gels was visualized by using an in vivo imaging system (IVIS). Results: P407Gels showed a thermo-reversible phase transition at $4^{\circ}C$ (refrigerated; sol) and $37^{\circ}C$ (body temperature; gel). The G-Temp, G-Time, and G-Dur of FD-free P407Gels were approximately $10^{\circ}C-20^{\circ}C$, 12-30 seconds, and 12-35 hours, respectively, and were not altered by the addition of FD. Fluorescence imaging showed that FD was spread homogenously in the gelled P407 solution. In a bladder simulation model, even after repeated periodic filling-emptying cycles, the hydrogel formulation displayed excellent retention with continuous release of the probe over 8 hours. The FD release from P407Gels and the erosion of the gel, both of which followed zero-order kinetics, had a linear relationship ($r^2=0.988$). IVIS demonstrated that the intravesical retention time of P407Gels was over 4 hours, which was longer than that of the FD solution (<1 hour), even though periodic urination occurred in the mice. Conclusions: FD release from P407Gels was erosion-controlled. P407Gels represent a promising system to enhance intravesical retention with extended drug delivery.

희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현 (Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array)

  • 김강식;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.419-430
    • /
    • 2002
  • 본 논문에서는 양방향 화소단위 집속 기법을 희박 어레이 기법을 사용하여 효율적으로 구현하는 방법에 대해 제안한다. 제안한 방법은 각 주사선을 구성할 때 합성에 이용되는 부구경 사이의 간격을 멀리함으로써 적은 수의 부구경으로 큰 크기의 합성구경을 형성하여 시스템의 복잡도를 감소시키면서 초음파 영상의 해상도와 프레임율을 향상시키게 된다. 하지만 이때 합성에 사용되는 부구경 사이의 간격 증가로 인해 그레이팅 로브 값은 상승하게 된다. 이러한 그레이팅 로브는 일반적인 합성구경 기법에서는 제거할 수 있다. 하지만 본 논문에서는 일반적인 합성구경 기법과는 달리 양방향 화소단위 집속 기법에서는 부구경 사이의 간격이 클 경우 발생하는 그레이팅 로브를 제거할 수 없음을 이론적으로 해석하였다. 또한 이러한 그레이팅 로브 값을 송신 집속점을 근거리에 위치시키고 합성에 사용되는 부구경간의 간격을 수신부구경의 크기에 비례하여 적절히 선택함으로써 의료용 초음파 영상에 적합한 -40dB 이하로 억제하는 방법과 조건을 제시하였다. 모의 생체와 실제 인체 실험 결과 제안한 방법을 통해 보다 적은 수의 부구경을 이용하여 더욱 빠른 프레임율의 양방향 화소단위 집속 기법의 구현이 가능함을 확인하였다

형광 X선 CT에서 촬상 시간의 단축화 알고리즘 (Algorithm to Shorten Imaging Time in Fluorescent X-ray Computed Tomogrpahy)

  • 정남채
    • 융합신호처리학회논문지
    • /
    • 제2권4호
    • /
    • pp.46-52
    • /
    • 2001
  • 방사광을 이용한 형강 X선 CT 이미징의 고속화를 위한 촬상 시스템과 처리 알고리즘을 검토하였다. 본 논문에서 사용된 촬상시스템은 고계수율 영역에서 안정된 동작을 한 전자 시스템으로 불감시간이 약 6%로 감소되고 계측시간의 경우도 1 점 당 3초로 단축되었다. 또한 재구성 알고리즘의 효율화를 증명하였고, 메모리와 계산량을 약 1/100로 감소시켰다. 물리적 phantom으로 그 정량성을 확인하였고, 시험관내의 갑상선의 화상으로부터 요드 분포를 추정하였다. 이러한 결과는 생체내에서 형광 X선 CT 계측의 실현 가능성을 보여준 것이다.

  • PDF

Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy

  • Bo-Wi Cheon ;Hyun Cheol Lee;Sei Hwan You;Hee Seo ;Chul Hee Min ;Hyun Joon Choi
    • Nuclear Engineering and Technology
    • /
    • 제55권6호
    • /
    • pp.2018-2025
    • /
    • 2023
  • In our previous study, we proposed an integrated PG-PET-based imaging method to increase the prediction accuracy for patient dose distributions. The purpose of the present study is to experimentally validate the feasibility of the PG-PET system. Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. The performance of this system as equipped with a proof of principle, we measured the PG and positron emission (PE) distributions from a 3 × 6 × 10 cm3 PMMA phantom for a 45 MeV proton beam. The measured depth was about 17 mm and the expected depth was 16 mm in the computation simulation under the same conditions as the measurements. In the comparison result, we can find a 1 mm difference between computation simulation and measurement. In this study, our results show the feasibility of the PG-PET system for in-vivo range verification. However, further study should be followed with the consideration of the typical measurement conditions in the clinic application.

실험동물용 가시광선/근적외선 생체 이미징 소형 장비의 개발 (Development of Small System for Mobile-Based Visible/NIR Animal Imaging)

  • 엄년식;박희준;정진용;한정현;김형경;장은윤;이석재;강병호;강신원
    • 센서학회지
    • /
    • 제21권4호
    • /
    • pp.270-275
    • /
    • 2012
  • In this study, we have developed a mobile-based visible/NIR(Near InfraRed) imaging equipment for the animal testing. This equipment can provide visible, NIR and merged image through the viewer program. Especially, merged image help researcher to understand visual messages at animal in-vivo test. Also, it is available to send real-time images through the smart phone. Researcher can communicate with another researcher who is a long distance away. Also, the equipment was made with portable small size to enable it to commercialize.