• 제목/요약/키워드: Impulse voltages

검색결과 100건 처리시간 0.03초

임펄스전류에 의한 배전용 ZnO 피뢰기 소자의 열화특성 (Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents)

  • 이복희;조성철;양순만
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.79-86
    • /
    • 2013
  • In order to analyze the electrical performance of ZnO surge arresters stressed by the combined DC and AC voltages that are generated in DC/AC converter systems, the leakage current properties of ZnO surge arrester blocks deteriorated by impulse currents were investigated. The test specimens were deteriorated by the 8/$20{\mu}s$ impulse current of 2.5kA and the leakage currents flowing into the deteriorated zinc oxide(ZnO) arrester blocks subjected to the combined DC and power frequency AC voltages are measured. As a result, the leakage currents flowing through deteriorated ZnO surge arrester blocks were higher than those flowing through the fine ZnO surge arrester blocks and the larger the injection number of 8/$20{\mu}s$ impulse current of 2.5kA is, the greater the leakage current is. The leakage current-voltage curves(I-V curves) of the fine and deteriorated ZnO surge arrester blocks stressed by the combined DC and AC voltages show significant difference in the low conduction region. Also the cross-over phenomenon is observed at the voltage close to the knee of conduction on plots of I-V curves.

습한 토양의 임펄스방전특성 (Characteristics of Impulse Discharges in Wet Soil)

  • 김회구;이복희
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.363-369
    • /
    • 2017
  • This paper presents the experimental results related to soil ionization and electrical breakdown in a concentric hemispherical electrode system under lightning impulse voltages. Dynamic voltage-current and impedance-time characteristics of soil ionization were measured and analyzed. Also the electrical breakdowns of the soil gap were investigated. The time-lag to the peak current corresponds to the soil ionization propagation. The time of ionization propagation in wet sand is found to decrease with increasing the impulse currents. A drastic decrease in ground resistance was observed during the impulse current spreading in sand. The electrical breakdown appears at the wave tail of impulse voltage and results in a wide scatter in V-t curves. The voltage-current curves have a fan-like shape attributed to ionization processes which result in increasing current and decreasing voltage.

준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성 (Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field)

  • 이복희;김동규;이봉
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.126-132
    • /
    • 2010
  • 본 논문은 준평등전계중에서 임펄스전압에 대한 $N_2$가스의 절연파괴특성에 관한 것으로 실험은 1.2/50[${\mu}s$] 표준뇌임펄스전압, 180/2500[${\mu}s$] 개폐임펄스전압과 500[ns]/1[MHz] 급준성 과도과전압이 인가된 전극계에서 이루어졌다. 구-평판 전극의 간격은 14[mm]이고, 전계이용률은 71.2[%]이었으며 가스압력은 0.2~0.6[MPa]범위로 하였다. 그 결과 절연파괴는 스트리머방전에 의하여 일어났으며, 절연파괴전압은 상승시간이 빠른 급준성 과도과전압에서 가장 높게 나타났다. 정극성 절연파괴전압이 부극성보다 높았으며, 정극성의 경우 절연파괴까지의 시간도 더 긴 것으로 나타났다.

뇌서지가 ZnO바리스터에 미치는 영향 (Effects of Lightning Surges on the Life of ZnO Varistors)

  • 이봉;이수봉;강성만;이복희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.257-262
    • /
    • 2006
  • To evaluate the change in protective levels of zinc oxide (ZnO) varistors after the surge absorption, this paper investigated the effects of the number of injection and amplitude of lightning surges on the life of ZnO varistors for low voltages. Leakage currents flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages were measured. The surge simulator system ECAT that can generate $8/20{\mu}s$ impulse currents with a peak short-circuit of 5 $[kA_p]$ was used. The ZnO varistor leakage current increases with exposure to impulse current, and the number of injection of $8/20{\mu}s$ impulse currents to breakdown was inversely proportional to the amplitude of the test current. Behaviors of ZnO varistor leakage currents were strongly dependent on the number of injection and amplitude of $8/20{\mu}s$ impulse currents. ZnO varistors degrade gradually when subjected to impulse current, and the resistive leakage current flowing through ZnO varistors subjected to the $8/20{\mu}s$ impulse currents under 60 Hz AC voltages was significantly increased after a certain number of injection that is dependent on the amplitude of the test impulse current. As a result, the life of ZnO varistors mainly depends on the amplitude and occurrence frequency of lightning surges.

이격거리가 큰 전극의 공기 절연파괴에 영향을 미치는 인자측정에 관한연구 (A Study on the Measurements of Parameters Affecting the Breakdown Mechanism of a Large Air Spacing)

  • 조연옥;최영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.756-760
    • /
    • 1988
  • The paper presents the measurement results on the parameters affecting the breakdown mechanism of a large air spacing under switching impulse voltages. Measured parameters are the velocities of leader channels, predischarge currents, electric charges injected into the rod-plane air gap and electric field intensities on the plane. For the 3m air gap under switching impulse voltages, the velocities of leader channel have been measured to be of 1cm/${\mu}s$ - 5cm/${\mu}s$, electric field intensity of 2kv/cm, predischarge current of 1.2A - 1.6A, the charges injected into the air gap of 11 - 40 ${\mu}$C for 400-887kV impulse voltages.

  • PDF

임펄스전압에 대한 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages)

  • 이복희;장석훈;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

낙뢰 리더의 대지부착과정에 대한 기초적 연구 (A Basic Study on the Attachment Process of Lightning Leader to Ground)

  • 유양우;김승민;김유하;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권10호
    • /
    • pp.82-88
    • /
    • 2014
  • This paper presents the results of model tests for the attachment process of lightning leader to ground which is one of poorly understood processes of cloud-to-ground lightning discharges. In order to simulate the attachment process of lightning leader to ground, we investigated the discharge characteristics of air gap between the tip of needle-shaped electrode and the soil surface as a parameter of moisture content in soils when the positive and negative $1.2/50{\mu}s$ lightning impulse voltages are applied. The breakdown voltage and the discharge light were observed. As a result, the attachment processes of lightning leader to ground are strongly dependent on the grain size and the moisture content of soils. The time to breakdown was shortened with increasing the magnitude of incident impulse voltages. The delay time from application of the highest voltage to breakdown in sand is shortened with increasing the moisture content. The delay time from application of the voltage to breakdown in gravel varied from about $0.5{\mu}s$ to several ${\mu}s$. As the moisture content in soil increases, the breakdown voltages are decreased and the breakdown voltage versus time to breakdown curves are shifted toward the lower side. The results obtained in this work are similar to those for non-uniform air gap stressed by lightning impulse voltages.

$SF_6-N_2$혼합기체 중에서 불평등전계 갭의 임펄스 절연파괴 특성 (Impulse Breakdown Characteristics of Nonuniform Field Gap in SF_6-N_2 Mixtures)

  • 이복희;이경옥;김정일
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.533-540
    • /
    • 2000
  • Lightning impulse $(1.2/44[\mus])$ and damped oscillating impulse $(Osc./44[\mus])$ : 0.83[MHz]) breakdown characteristics in sulphur-hexafluoride/nitrogen (SF6-N2) mixtures were investigated. The predischarge currents were observed to clarify the breakdown mechanism. th experiments were carried out under nonuniform electric fields disturbed by a needle-shaped protrusion whose length and diameter are 10[mm] and 1[mm] at total gas pressure up to 0.5[MPa] with nitrogen concentrations varying from 5 to 20[%] in the mixture. The electrical breakdowns of SF6-N2 mixtures for both the positive and negative polarities develop with steplike pulses in leader mechanism and the breakdown voltage -time (V-t) characteristics were affected by the space charge. The voltage-time curves for the negative oscillating impulse voltage were extended over the longer time range. The minimum breakdown voltages for the negative lightning and oscillating impulse voltage were higher than those for the positive ones. in particular the positive breakdown voltages were independent of the gas pressure.

  • PDF

A Numerical Approach for Lightning Impulse Flashover Voltage Prediction of Typical Air Gaps

  • Qiu, Zhibin;Ruan, Jiangjun;Huang, Congpeng;Xu, Wenjie;Huang, Daochun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1326-1336
    • /
    • 2018
  • This paper proposes a numerical approach to predict the critical flashover voltages of air gaps under lightning impulses. For an air gap, the impulse voltage waveform features and electric field features are defined to characterize its energy storage status before the initiation of breakdown. These features are taken as the input parameters of the predictive model established by support vector machine (SVM). Given an applied voltage range, the golden section search method is used to compute the prediction results efficiently. This method was applied to predict the critical flashover voltages of rod-rod, rod-plane and sphere-plane gaps over a wide range of gap lengths and impulse voltage waveshapes. The predicted results coincide well with the experimental data, with the same trends and acceptable errors. The mean absolute percentage errors of 6 groups of test samples are within 4.6%, which demonstrates the validity and accuracy of the predictive model. This method provides an effectual way to obtain the critical flashover voltage and might be helpful to estimate the safe clearances of air gaps for insulation design.

뇌임펄스전압에 대한 30[A]용 고감도형 누전 차단기의 오동작에 대한 특성의 해석 (Analysis of Malfunction Characteristics of High Sensitivity Type Earth Leakage Circuit Breaker for 30[A] due to Lightning Impulse Voltages)

  • 이복희;이승칠;김찬오
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.96-103
    • /
    • 1997
  • 본 논문은 뇌임펄스전압에 대한 누전 차단기의 오동작 특성에 관한 것으로 한국공업규격 KS C 4613의 규정과 서지보호장치를 갖는 모의회로의 조건에서 누전차단기의 부동작 특성을 실험적으로 조사하고 검토하였다. 실험 결과, 본 연구에 사용한 30[A]용 고감도형 누전 차단기인 모든 시료는 증폭회로의 전원부에 설치된 서지보호장치에 의해 입사되는 차동모드의 뇌임펄스전압에 차단되는 성능을 가지고 있었다. 4종의 시료는 KS C 4613에 정의된 뇌임펄스 부동작시험조건을 만족시키지 못하였으며, 그때의 오동작을 유발한 전압은 약 5∼6.5[kV]로 비교적 높았다. 서지보호장치가 설치된 경우를 모의한 시험조건에서는 3종의 누전차단기가 오동작하였으며, 누전차단기가 오동작을 일으키는 전압도 약 3∼5[kV] 정도로 비교적 낮았다.

  • PDF