• 제목/요약/키워드: Impulse test

검색결과 723건 처리시간 0.037초

피뢰기용 단로기의 특성 및 성능 평가 (Properties & Performance Evaluation of Disconnector for Surge Arrester)

  • 김석수;최익순;정낙헌;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.546-547
    • /
    • 2005
  • This study aims to evaluate the properties and the performance of the newly designed disconnector for surge arrester. This disconnector was verified with the performance in long-duration current impulse test and high current impulse test. And time-current characteristic test was done at 20A, 200A and 800A(3points) for simulating the internal fault condition of the arrester. The results of this test was very good. Consequently, the newly designed disconnector was, evaluated that it is possible to be used for surge arrester in distribution line system.

  • PDF

누전차단기의 EMC 조합서지 내성 강화를 위한 방안 (The Method of Reinforcing the Immunity of Residual Current Circuit Breaker for the EMC Composite Surge)

  • 김재철;한윤탁;김언석;설규환;강장규;문종필
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권8호
    • /
    • pp.322-328
    • /
    • 2006
  • In this paper, The impulse un-tripping characteristics and the electro magnetic compatibility characteristics are compared with each other. The performance of impulse un-tripping test exists at domestic standard (KSC 4613). However test items are insufficient because the more test items such as EMC exist at international standard (IEC). Also, Electric Appliances Safety Certificate has taken the certificate test since July 2004 in Korea but did not confirm the EMC performance for RCCBs made in Korea. Thus, in this paper, We experiment with Oscillatory waves immunity test and the 7 EMC tests for 32 RCCBs of 4 types (mini, home standard, plug, outlet) for 16 brands according to IEC standard 61009-1 and 61008-1. As a result, 24 RCCBs proved to be poor for surge immunity test. However the RCCBs operating incorrectly for surge immunity test operate correctly for oscillatory waves immunity test. Thus, the correlation between oscillatory waves immunity test and EMC test is little and standard for compatibility of combination surge at IEC 61000-4-5 should be added to KS standard as soon as possible.

판상 구조물 비파괴검사를 위한 충격응답시험기의 개발 (Development of the Impulse Response Measurement System for Non-destructive Test of Slab Structure)

  • 정호준;이희순;오석훈;송성호
    • 지구물리와물리탐사
    • /
    • 제16권1호
    • /
    • pp.45-52
    • /
    • 2013
  • 본 연구에서는 판상 구조물의 비파괴시험을 위한 충격응답시험기 및 운용 소프트웨어를 개발하였으며, 콘크리트 또는 아스팔트로 포장된 인도에서 충격응답 자료 취득 시험을 실시하였다. 현장 자료 취득 시험에서 개발된 시스템은 안정적으로 신속하게 충격응답반응을 측정하였다. 현장 시험 결과, 포장재 특성에 따라 동적강성, 평균운동성 등의 절대 값이 크게 변화 하였다. 또한 일부 구간에서는 포장재 또는 하부 지반의 변화를 반영하는 것으로 판단되는 값의 변화가 측정되었다. 본 연구를 통해 만들어진 시스템은 판상구조물의 상태에 대한 정보를 쉽고 빠르게 획득할 수 있을 것으로 판단된다. 본 연구에서 개발된 장비를 이용하여 조사 대상물에 대한 2차원 측정과 모니터링을 한다면, 구조물의 유지 보수에 유용한 정보를 얻을 수 있을 것으로 기대된다.

가공 배전선로 중성선과 가공지선 겸용시의 임펄스 특성 연구 (The Study on the Impulse Characteristic of Secondary Arresters in Power Distribution System)

  • 강문호;김동명;송일근;천성남
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.297-299
    • /
    • 2004
  • In multi-ground distribution system, overhead ground wire and neutral wire are parallel connected to offer the electrical power energy and protect damage of lightning strokes. Therefore a case where the two wires become single wire, the power company can get the benefit such as installation cost saving and line fault protection by simplify of distribution line. In this paper we describe the result of impulse test in both system ; one is the present power system the other is unified power system parallel connected overhead ground wire and neutral wire. As a result of this impulse test, the present power system get lower impulse voltage than the unified power system.

  • PDF

22.9 kV CV 전력케이블의 14주기 고온 열화에 대한 Lightning-Impulse 특성 (Lightning Impulse Characteristics for 22.9 kV CV Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1549-1551
    • /
    • 2001
  • Cyclic aging for 14 days is performed to remove a large amount of the volatiles found in freshly manufactured cable. In this paper, we examined lightning impulse characteristics of 22.9 kV CV power cable before and after cyclic aging for 14days. As the result, the breakdown voltage after aging under normal temperature was lower than that before aging, and the breakdown voltage after aging under hot temperature was lower than that before aging. We found that the dispersion of lightning impulse breakdown voltage before 14 cyclic aging test were reduced rather than those after 14 cyclic aging test.

  • PDF

유압 피팅 충격압시험기 개발 (Hydraulic fitting impulse tester development)

  • 김형의;이용범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.917-921
    • /
    • 1991
  • Hydraulic fitting impulse tester is equipment which produce impulse pressure waveform that specified foreign standard of SAE, JIS etc. Test conditions of SAE J1453 about waveform standard indicates frequency of 35-70 cycle/min, pressure of 560 bar, oil temperature of 93 .+-.3.deg. C etc. and required cycle is a million over. In additions, Test condition operated continuously equipment. This development item adopted new pattern method such as intensifier and rotary distributor is different from already established fitting impulse tester applied servo valve and high pressure direct directional control valve. Therefore, this development item which compares already established item is good reliability, low cost of manufacture and save of electric energy. especially, Domestic small and medium enterprise uses this tester because of economical cause. We develope appropriateness tester which conforms to demand of user.

  • PDF

여성 캐릭터 의류 브랜드 구매자의 충동구매에 영향을 미치는 마케팅 요인과 브랜드 이미지에 대한 연구 (A Study on the Marketing Factors and the Brand Image Influencing the Impulse Purchase Tendency of Women Who Buy Character Clothing Brands)

  • 신수연;이정미
    • 한국의류학회지
    • /
    • 제22권7호
    • /
    • pp.833-842
    • /
    • 1998
  • The purpose of this study is to (1) investigate on the impulse purchase tendency of women who buy women's character clothing brands and (2) to clarify the relationship between the women's impulse purchase tendency and the marketing factors, and the brand image. The subjects were 203 women in their twenties and thirties who had purchased the women's character clothing brands in last six months living in Seoul. The data were collected by self-administered questionnaire and were analyzed by frequency, percentage, t-test, clustering analysis and MDS(Multi-Dimensional Scale). The results of the study were as follows: (1)66.0% of the women were categorized as the group of high-degree of impulse purchase tendency and 34.0% of the women were identified as the group of low-degree of impulse purchase tendency. (2) In identifying the relationship between the marketing factors and the impulse purchase tendency, the group of the high-degree of impulse purchase tendency was affected by the marketing factors such as new and fashionable products, status of display, advertising and discout selling. (3) Brand image was not statistically significant according to the impulse purchase tendency. As a whole, 'Obzee' was recognized as unique-style and sexy brand, 'Time' and 'Mine' were thought as the reasonable-prince and basic-style brands, 'Deco' were clarified as the intellectual-image brand, and 'Ego' and 'Telegraph' were revealed as high-price-image brands.

  • PDF

인터넷 쇼핑에서의 충동구매 측정을 위한 척도의 개발 및 특성분석 (Developing Standards for Measuring Consumer's Impulse Purchasing in Internet Shopping Mall and Analysis of Characteristics)

  • 장현선
    • 가정과삶의질연구
    • /
    • 제27권4호
    • /
    • pp.127-139
    • /
    • 2009
  • The purpose of this study was to develop a standardized scale to measure consume's impulse purchasing in internet shopping mall. As internet shopping is expanding rapidly, the consumer's impulse purchasing in the internet shopping is also increased. A preliminary 26-item scale was developed through a literature review. 1230 consumers responded to an online survey using the preliminary scale. This research was made with the intention of not only supplying the academic data on the consumer's impulse purchasing but also understanding the consume's basic behavior patterns in internet shopping mall. Then A series of tests, such as test-retest, item-to-total correlation, Cronbach's reliability coefficient and factor analysis, were conducted using the survey data. The final scale with 20-items was constructed in the end. The consume's impulse purchasing in internet shopping mall Scale for Consumers consisted of 4 factors.

형상이 다른 접지전극에 접속된 심매설 봉상 접지전극의 임펄스접지임피던스 특성 (Impulse Ground Impedances of a Deeply Driven Ground Rod Combined with Different Shape Grounding Electrodes)

  • 이복희;이수봉;장근철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.63-68
    • /
    • 2005
  • 본 논문은 메쉬 접지전극이나 침부 매설지선이 연결된 심매설 봉상 접지전극의 실효임펄스접지임피던스의 특성을 다루었다. 시험용 접지전극의 전위상승은 인가된 임펄스 전류의 상승시간의 함수로 측정되었고, 실효임펄스접지 임피던스는 산출되었다. 심매설 봉상 접지전극의 임펄스접지임피던스는 임펄스 전류의 상승시간에 강하게 의존하며 메쉬 접지전각과의 병렬연결에 의해 확연히 감소하였다.

EFFICIENT DESIGN OF CAPACITOR DISCHARGE IMPULSE MAGNETIZER SYSTEM FOR 8-POLE MAGNET

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.828-832
    • /
    • 1995
  • This paper describes the efficient design, analysis method and experimental verification of capacitor discharge impulse magnetizer system. A capacitor discharge magnetizer system is used to produce a high current impulse of short duration in this magnetizing fixture. The parasitic resistance and parasitic inductance of the capacitor discharge impulse magnetizer system have been estimated using known air-core test coil. Finite element analysis (using MAXWELL 2-D field simulator) and magnetizing circuit analysis (using SPICE) are also used as part of the design and analysis process of the capacitor discharge impulse magnetizer system. Application study for a magnetizing fixture design is shown. 8-pole magnetizing fixture has been designed and analyzed using finite element analysis. The fixture design for 8-pole magnet are presented along with the experimental results. The experimental results have been achieved using a high-voltage, high-energy capacitor discharge impulse magnetizer and 8-pole iron core fixtures (charging voltage : 2000[V], capacitor bank : 4000[$\mu\textrm{F}$]).

  • PDF