• Title/Summary/Keyword: Impulse performance

Search Result 780, Processing Time 0.03 seconds

Detection Based - Adaptive Windowed Nonlinear Filters for Removal of One-Side Impulse Noise in Infrared Image (적외선 영상의 단측형 충격잡음 제거를 위한 검출기반 적응윈도우 비선형 필터)

  • LEE JE-IL
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.6
    • /
    • pp.83-88
    • /
    • 2005
  • In this paper, detection based - adaptive windowed nonlinear filters(DB-AWNF) are proposed for removing one-side impulse noise in infrared image. They are composed of impulse detector and window-size-variable median filters. Impulse detector checks whether current pixel is impulse or not using range function and nonlinear location estimator. If impulse is detected, current pixel is filtered according to four kinds of local masks by use of median filter. If not. current pixel is delivered to output like identity filter. In qualitative view, the proposed could have removed heavy corrupted noise up to $20\%$ and reserved the details of image. In quantitative view, PSNR was measured. The proposed could have 13 - 31[dB] more improved performance than those of median($3{\times}3$) filter and 18 - 25[dB] more improved performance than those of median($5{\times}5$) filter.

PAPR Improvement of OFDM-CQAM System through Optimum Position based Impulse Insertion in Frequency Domain (주파수영역 최적위치기반 임펄스 삽입에 따른 OFDM-CQAM 시스템의 PAPR 개선)

  • Kwak, Jae-min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2019.05a
    • /
    • pp.597-599
    • /
    • 2019
  • When frequency domain high amplitude impulse is inserted before IFFT in OFDM transmitter, the PAPR of OFDM signal in tme domain can be effectively reduced. In this paper, the degree of PAPR improvement of OFDM communication system with CQAM subcarrier modulation is analysed by adopting impulse insertion technique before IFFT of transmitter. Furthermore, it is verified that additional PAPR performance improvement can be obtained by finding optimum position of impulse insertion for maximizing PAPR reduction.

  • PDF

Performance Evaluations of the Lightning Impulse Voltage Measuring System by Intercomparative Test - in case of full lightning impulse voltage - (뇌충격 측정시스템의 비교시험에 의한 성능평가 - 전파 뇌충격전압 인가시 -)

  • Kim, Ik-Soo;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1368-1370
    • /
    • 1995
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard(IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Intercomparison tests of dividers for lightning impulse measurement were carried out by KERI. The shielded resisitive divider with 700kV rating developed by KERI were done comparison test with PTB divider with 300kV rating which have the similar charateristics as that were circulated among the laboratories. This paper reports on the comparison test results with full lightning impulse voltages from 126kV to 240kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

Design and Performance Evaluation of IR-UWB Tapered Slot Antenna for Optimum Impulse Radio Radiation (임펄스 신호 방사를 위한 IR-UWB용 테이퍼 슬롯 안테나 설계 및 성능평가)

  • Kim, Jong-Min;Koh, Young-Mok;Ra, Keuk-Whan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.5
    • /
    • pp.103-115
    • /
    • 2012
  • In this paper, design and performance evaluation of Tapered Slot Antenna for IR-UWB which propagates impulse radio is performed. TSA which has directional characteristic in UWB band should have low radiation loss and minimized impulse radiation distortion. In order to achieve these objectives, the paper designed wide band Impedance transformer and microstrip-slotline transit region structured TSA feeder line. By using the fabricated TSA, the radiation pattern was measured in the radio anechoic chamber. Pulse fidelity and distortion equation was induced to evaluate time domain characteristics according to the impulse radiation. Pulse fidelity of Impulse radiation show favorable results more than 93% within ${\pm}30^{\circ}$ beam width.

Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계)

  • Song, Hwa-Young;Kim, Deok-Han;Lee, Jong-Suk;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

Design & characteristics of impulse current test system for station class(up to class 5) (송변전급(up to class 5) Impulse current test system의 설계 및 특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Kang, Young-Sik;Park, Byung-Rak;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

Investigation of Large-scale Transmission Tower Grounding Grid with High Amplitude and Uniform Flowing Impulse Current

  • Yang, Shuai;Huang, Jiarui;Wei, Shaodong;Zhou, Wenjun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2050-2058
    • /
    • 2018
  • Impulse characteristic of transmission tower grounding grid is needed for lightning protection of transmission line. This paper describes an outdoor experimental test facility established for large-scale grounding grid of transmission tower, made up of four impulse current generators and a circle current return electrode. The amplitude of impulse current is up to 100 kA. The results of the CDEGS simulation and GPR measurement reveal the uniform current distribution in the test arrangement. An impulse test for a square electrode with extended conductors is carried out in condition of three current waveforms with different amplitude. Based on the electrical network model and iterative algorithm method, a calculation model is proposed to simulate the impulse characteristic of large-scale grounding grid considering soil ionization. The curve of impulse resistance against the current amplitude shows the soil ionization both from the simulation and test. Deviation between the simulation and test result is less than 15%.

Factors Characterizing the Pulse-mode Performance of Monopropellant Hydrazine Thrusters (하이드라진 추력기의 펄스모드 성능특성인자 해석)

  • Kim, Jeong-Soo;Park, Jeong;Lee, Jae-Won;Kim, In-Tae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.399-404
    • /
    • 2010
  • Test results including the variation of propellant-inlet pressure, pulsed thrust, and environment vacuum with the accompanying thermal responses are presented for the pulse-mode operation of a set of monopropellant hydrazine thrusters producing $0.95lb_f$ of nominal steady-state thrust at an inlet pressure of 350 psia. The test data are reduced into the impulse bit, specific impulse, and force centroid that are the factors typically characterizing pulse-mode performance of small rocket engines. With a scrutiny to the performance parameters, their comparison to the reference criteria of 1 lbf standard monopropellant rocket engine are successfully made.

  • PDF

Efficient Signal Detection Based on Artificial Intelligence for Power Line Communication Systems (전력선통신 시스템을 위한 인공지능 기반 효율적 신호 검출)

  • Kim, Do Kyun;Hwang, Yu Min;Sim, Issac;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.2
    • /
    • pp.42-45
    • /
    • 2017
  • It is known that power line communication systems have more noise than general wired communication systems due to the high voltage that flows in power line cables, and the noise causes a serious performance degradation. In order to mitigate performance degradation due to such noise, this paper proposes an artificial intelligence algorithm based on polynomial regression, which detects signals in the impulse noise environment in the power line communication system. The polynomial regression method is used to predict the original transmitted signal from the impulse noise signal. Simulation results show that the signal detection performance in the impulse noise environment of the power line communication is improved through the artificial intelligence algorithm proposed in this paper.

Properties & Performance Evaluation of Disconnector for Surge Arrester (피뢰기용 단로기의 특성 및 성능 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Jeong, Nak-Heon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.546-547
    • /
    • 2005
  • This study aims to evaluate the properties and the performance of the newly designed disconnector for surge arrester. This disconnector was verified with the performance in long-duration current impulse test and high current impulse test. And time-current characteristic test was done at 20A, 200A and 800A(3points) for simulating the internal fault condition of the arrester. The results of this test was very good. Consequently, the newly designed disconnector was, evaluated that it is possible to be used for surge arrester in distribution line system.

  • PDF