• Title/Summary/Keyword: Impulse control

Search Result 466, Processing Time 0.037 seconds

The Modified Median Filter using Standard Deviation in Impulse Noise Environment (임펄스 잡음환경에서 표준편차를 이용한 변형된 메디안 필터)

  • Long, Xu;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1725-1731
    • /
    • 2013
  • Recently, as industrial society is developed as high digital information age, image processing is used in a variety of areas. However, image deterioration is still occurred by several noises in the data processing, and different kinds of researches are in progress for noise removal. Therefore, this paper limited the modified median filter by using standard deviation to removes impulse noise. The proposed algorithms divided into noise detection and noise removal, the noise free pixel is maintained, the noise pixel filtered. And it was compared with the existing methods for its objective judgment, using PSNR(peak signal to noise ratio) as standard criteria.

A Study on Calcium Ion Reduction in Power Plant Water using High Voltage Impulse (고전압 임펄스를 활용한 발전용수 칼슘농도 저감에 관한 연구)

  • Kim, TaeHui;Chang, In-Soung;Jung, Jae-Hwan;Hong, Woong ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.545-550
    • /
    • 2017
  • As an alternate technique for water softening, high voltage impulse (HVI) is introduced and verified if it can control the $CaCO_3$ scale formation in industrial water treatment. After HVI was applied to the artificial hard water containing $100{\pm}5mg/L$ $Ca^{2+}$ for 4 hours, the $Ca^{2+}$ concentration and the electrical conductivity were measured. The concentration of $Ca^{2+}$ was reduced from 94.5 to 86.3 mg/L (8.7% reduction) after 4 hour contact of HVI under 5 kV condition. The $Ca^{2+}$ was decreased from 92 to 77.7 mg/L (15.6% reduction) at 8kV and from 90.1 to 75.4 mg/L (16.3% reduction) at 12 kV condition. Both of the contact time and the applied voltage were important parameters affecting the calcium ion reduction. With these results, it was verified that HVI technique could be potential candidate for control of $CaCO_3$ scale formation.

Effects of Self Myofascial Release, Elastic Band, and Stretching Exercises on Lower Extremity Alignment and Gait in Female Genu Varum

  • Lee, Hye-In;Lim, Bee-Oh
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.4
    • /
    • pp.207-211
    • /
    • 2018
  • Objective: The purpose of this study was to examine the effects of an 8-week SMR, stretching, and band program on lower limb alignment (distance between the knees, Q angle) and gait (gait speed, stride length, impulse, and peak pressure) in female in their 20s who have genu varum. Method: The participants, female in their 20s who had genu varum, were randomly divided into the SMR, Stretching, and Band group (SSB, n=9), Stretching and Band group (SB, n=9), and Control Group (CG, n=9). Experimental group A (SSB) performed 3 50-minute sessions of the program per week for 8 weeks while the experimental group B (SB) performed stretching and band correctional exercise in 3 40-minute sessions per week for 8 weeks. The control group had no correctional exercise program. Results: Only the SSB group showed a significant increase in gait velocity and stride length in this study. The SSB and SB group showed a significant decrease of impulse on the forefoot after exercise program suggests that SMR and elastic band exercise had a positive effect on the distribution of foot pressure. Conclusion: We concluded that 8-week genu varum correctional exercise program had beneficial effects on the gait parameters (gait velocity, stride length, impulse, peak pressure) in 20s women with genu varum.

Development of active noise control system for quieting transformer noise (변압기 주위소음 정음화 시스템 개발)

  • 최효열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1360-1363
    • /
    • 1997
  • Development and realizatioin of adaptive Active Noise Cntrol used for quieting transformer nosie are planed to provide workers with comfortable working environment and to attenuate the noise for residents in many noisy areas(power plant, power transformer, GIS transformer etc.).

  • PDF

Effect of a Coil Shape on an Impulse Velocity of the Electromagnetic Welding (전자기 용접의 충돌 속도에 대한 코일 형상의 영향)

  • Park, H.;Lee, K.;Lee, J.;Lee, Y.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.28 no.3
    • /
    • pp.135-144
    • /
    • 2019
  • Electromagnetic impulse welding (EMIW) is a type of solid state welding using the Lorentz force generated by interaction between the magnetic field of the coil and the current induced in the workpiece. Although many experimental studies have been investigated on the expansion and compression welding of tube using the EMIW process, studies on the EMIW process of lap joint between flat sheets are uncommon. Since the magnetic field enveloped inside the tube can be controlled with ease, the electromagnetic technique has been widely used for tube welding. Conversely, it is difficult to control the magnetic field in the flat sheet welding so as to obtain the required welding velocity. The current study analyzed the effects of coil shape on the impulse velocity for suitable flat one-turn coil for the EMIW of the flat sheets. The finite element (FE) multi-physics simulation involving magnetic and structural field of EMIW were conducted with the commercial software LS-DYNA to evaluate the several shape variables, viz., influence of various widths, thicknesses, gaps and standoff distances of the flat one-turn coil on the impulse velocity. To obtain maximum impulse velocity, the flat one-turn coil was designed based on the FE simulation results. The experiments were performed using an aluminum alloy 1050 sheets of 1.0mm thickness using the designed flat one-turn coil. Through the microscopic interfacial analysis of the welded specimens, the interfacial connectivity was observed to have no defects. In addition, the single lap joint tests were performed to evaluate the welding strength, and a fracture occurred in the base material. As a result, a flat one-turn coil was successfully designed to guarantee welding with bond strength equal to or greater than the base material strength.

Model based optimal FIR synthesis filter for a nosy filter bank system

  • Lee, Hyun-Beom;Han, Soo-Hee;Kwon, Wook-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.413-418
    • /
    • 2003
  • In this paper, a new multirate optimal finite impulse response (FIR) filter is proposed for the signal reconstruction in the nosy filter bank systems. The multirate optimal FIR filter replaces the conventional synthesis filters and the Kalman synthesis filter. First, the generic linear model is derived from the multirate state space model for an autoregressive (AR)input signal. Second, the multirate optimal FIR filter is derived from the multirate generic linear model using the minimum variance criterion. This paper also provides numerical examples and results. The simulation results illustrate that the performance is improved compared with conventional synthesis filters and the proposed filter has advantages over the Kalman synthesis filter.

  • PDF

Detection of Leakage Point via Frequency Analysis of a Pipeline Flow

  • Kim, Sanghyun;Wansuk Yoo;Injoon Kang
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.232-238
    • /
    • 2001
  • Fast Fourier Transformation is employed to convert the head variation of a pipeline in the time domain to the amplitude of the frequency domain. Applying method of characteristics to a pipeline provides a significant frequency range for a surge introduced from the valve modulation. Inverse Fast Fourier Transformation and a Finite Impulse Response Filter can be used to remove any possible noise existing from the significant frequency range of an unsteady condition. A filtered signal shows higher potential for the inverse calculation of leakage detection than the noise-added signal does. The respective performances of Inverse Fast Fourier Transformation and a Finite Impulse Response Filter are compared in terms of leakage detection capability. Characteristics of the frequency range for multiple leakages were investigated to validate the effectiveness of the noise control method in the frequency domain.

  • PDF

Generalized Directional Morphological Filter Design for Noise Removal

  • Jinsung Oh;Heesoo Hwang;Changhoon Lee;Younam Kim
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.115-119
    • /
    • 2002
  • In this paper we present a generalized directional morphological filtering algorithm for the removal of impulse noise, which is based on a combination of impulse noise detection and a weighted rank-order morphological filtering technique. For salt (or pepper) noise suppression, the generalized directional opening (or closing) filtering of the input signal is selectively used. The detection of impulse noise can be done by the geometrical difference of opening and closing filtering. Simulations show that this new filter has better detail feature preservation with effective noise reduction compared to other nonlinear filtering techniques.

  • PDF

Compensation of errors caused by resonance vibration of measurement system in impact force measurement

  • Usui, Y.;Miyazawa, S.;Sawai, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.593-596
    • /
    • 1994
  • When a force impulse acting on a massive and plex object is measured with a dynamometer, be resonant vibration of the measurement system often leads to serious inaccuracies. A more accurate measurement is obtained when the transfer function ,of the object-dynamometer system is used to compensate for the error in the dynamometer's output signal. The natural frequency and the damping coefficient of the transfer function are estimated by analyzing the waveform of the free damped vibration period after the loading of the force has ended. The residue of the system is determined such that the compensated force spectrum becomes smooth within a neighborhood of the natural frequency. The effectiveness of this signal processing method is experimentally tested on a hammer impulse, under the assumption that the hammer's high resonant frequency accurately models the problems encountered in force impact measurement. The compensation method is used to derive a improved estimate of the hammer impulse.

  • PDF

Characterization of Noise Exposure in the Tank Gun Drill Ranges (군대 전차포 훈련장에서의 소음노출 특성)

  • Hwang, Sung Ho;Park, Jae Bum
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.74-78
    • /
    • 2014
  • Objectives: Purpose of this study was to evaluate the noise level exposures at the different cannonball type and locations in the tank gun drill ranges. Methods: We visited the tank gun drill ranges and measured with a sound level meter(3M Quest SoundPro$^{TM}$) with the value of Peak(dB(A)). Results: The highest peak value of impulse noise level averaged 166.3 dB(A) at the site of loading solider. The highest peak value of impulse noise level by size of cannonball averaged 165.9 dB(A) at the 120 mm size cannonball of the tank. This result was significantly different from the other size of cannonballs such as 7.62 mm, 90 mm, and 105 mm(p < 0.001). Among the four types of soldier site on the tank, average noise levels of loading soldier, 156.6 dB(A), were higher than the other three types of soldier site (p > 0.05). Conclusions: This study confirmed that there were needed for a proper control to reduce the amount of impulse noise exposure at the tank gun drill ranges.