• 제목/요약/키워드: Impulse Voltage

검색결과 411건 처리시간 0.031초

송전선로에 사용되는 갭형 피뢰기 소자의 뇌임펄스 전류특성 (Characteristics of Lightning Impulse Current of ZnO Block for Transmission Line Arrester with External Gap)

  • 조한구;유대훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.458-459
    • /
    • 2007
  • This paper describes the characteristics of lightning impulse current of ZnO block for transmission line arrester with external gap. The ageing parameters of lightning arresters are impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by impulse current. Total energy applied to the ZnO arrester each time is $4/10{\mu}s$, 30kA and $2/20{\mu}s$, 10kA impulse current. Before and After the test, the residual voltage variation of varistors passed was below 5%. According to the test, it is thought that the ZnO arrester shows good stability with impulse current test.

  • PDF

준평등전계에서 임펄스전압에 대한 N2가스의 절연파괴특성 (Dielectric Characteristics of N2 Gas under Impulse Voltage in a Quasi-Uniform Electric Field)

  • 이복희;김동규;이봉
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.126-132
    • /
    • 2010
  • 본 논문은 준평등전계중에서 임펄스전압에 대한 $N_2$가스의 절연파괴특성에 관한 것으로 실험은 1.2/50[${\mu}s$] 표준뇌임펄스전압, 180/2500[${\mu}s$] 개폐임펄스전압과 500[ns]/1[MHz] 급준성 과도과전압이 인가된 전극계에서 이루어졌다. 구-평판 전극의 간격은 14[mm]이고, 전계이용률은 71.2[%]이었으며 가스압력은 0.2~0.6[MPa]범위로 하였다. 그 결과 절연파괴는 스트리머방전에 의하여 일어났으며, 절연파괴전압은 상승시간이 빠른 급준성 과도과전압에서 가장 높게 나타났다. 정극성 절연파괴전압이 부극성보다 높았으며, 정극성의 경우 절연파괴까지의 시간도 더 긴 것으로 나타났다.

장간유리애자 파손시 절연파괴 특성 (The Electrical Breakdown Characteristics of Broken Toughened Glass Stem Insulator)

  • 정종욱;정진수;김영석
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1398-1406
    • /
    • 2008
  • This paper describes the electrical breakdown characteristics of broken toughened glass stem insulators by comparing with those of sound ones. The broken toughened glass stem insulators were taken from the electric railway field. According to the international standards, the sound and broken toughened glass stem insulators were tested in electrical strength. In the test, the power frequency voltage and the impulse voltage with a standard waveform were applied to the insulators. The power frequency voltage tests were carried out under both dry and wet condition and the impulse voltage tests under only dry condition. The acquired results were compared one another and discussed in electrical breakdown characteristic by analyzing the flashover progress pictures. As a result, the electrical strength of the broken toughened glass insulators was acquired and the processes of the surface breakdown on the toughened glass insulators were confirmed.

Cost Effective Design of High Voltage Impulse Generator and Modeling in Matlab

  • Javid, Zahid;Li, Ke-Jun;Sun, Kaiqi;Unbreen, Arooj
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1346-1354
    • /
    • 2018
  • Quality of the power system depends upon the reliability of its components such as transformer, transmission lines, insulators, circuit breakers and isolators. The transient voltage due to internal or external reasons may affect the insulation level of the components. The insulation level of these components must be tested against these conditions. Different studies, testing of different electrical components against high voltage impulses and different industrial applications rely on the international manufactures for pulsed power generation and testing, that is quite expensive and large in size. In this paper a model of impulse voltage generator with capacitive load of pin type insulator is studied by simulation method and by an experimental setup. A ten stage high voltage impulse generator (HVIG) is designed and implemented for different applications. In this proposed model, the cost has been reduced by using small and cheap capacitors as an alternative for large and expensive ones while achieving the same effectiveness. Effect of the distributed capacitance in each stage is analyzed to prove the effectiveness of the model. Different values of front and tail resistances have been used to get IEC standard waveforms. Results reveal the effectiveness at reduced cost of the proposed model.

뇌충격 측정시스템의 비교시험에 의한 성능평가 - 전파 뇌충격전압 인가시 - (Performance Evaluations of the Lightning Impulse Voltage Measuring System by Intercomparative Test - in case of full lightning impulse voltage -)

  • 김익수;김영배;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1368-1370
    • /
    • 1995
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard(IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Intercomparison tests of dividers for lightning impulse measurement were carried out by KERI. The shielded resisitive divider with 700kV rating developed by KERI were done comparison test with PTB divider with 300kV rating which have the similar charateristics as that were circulated among the laboratories. This paper reports on the comparison test results with full lightning impulse voltages from 126kV to 240kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구 (A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence)

  • 오휘명;최성수;이재조;김관호;황금찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권1호
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

$SF_6-N_2$혼합기체 중에서 불평등전계 갭의 임펄스 절연파괴 특성 (Impulse Breakdown Characteristics of Nonuniform Field Gap in SF_6-N_2 Mixtures)

  • 이복희;이경옥;김정일
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권9호
    • /
    • pp.533-540
    • /
    • 2000
  • Lightning impulse $(1.2/44[\mus])$ and damped oscillating impulse $(Osc./44[\mus])$ : 0.83[MHz]) breakdown characteristics in sulphur-hexafluoride/nitrogen (SF6-N2) mixtures were investigated. The predischarge currents were observed to clarify the breakdown mechanism. th experiments were carried out under nonuniform electric fields disturbed by a needle-shaped protrusion whose length and diameter are 10[mm] and 1[mm] at total gas pressure up to 0.5[MPa] with nitrogen concentrations varying from 5 to 20[%] in the mixture. The electrical breakdowns of SF6-N2 mixtures for both the positive and negative polarities develop with steplike pulses in leader mechanism and the breakdown voltage -time (V-t) characteristics were affected by the space charge. The voltage-time curves for the negative oscillating impulse voltage were extended over the longer time range. The minimum breakdown voltages for the negative lightning and oscillating impulse voltage were higher than those for the positive ones. in particular the positive breakdown voltages were independent of the gas pressure.

  • PDF

직류 피뢰기용 ZnO 소자의 전기적 특성 (The Electrical Characteristics of ZnO varistor for d.c. Arrester)

  • 김석수;최익순;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1106-1110
    • /
    • 2003
  • The electrical characteristics of $A{\sim}C's$ ZnO varistors fabricated according to variable sintering condition, which sintering temperature is $l130^{\circ}C$ and speeds of pusher are A: 2mm/min, B: 4mm/min, C: 6 mm/min, respectively, were investigated. The varistor voltage of $A{\sim}C's$ ZnO varistors sintered at $1130^{\circ}C$ increased in order A < B $A{\sim}C's$ ZnO varistors exhibited below 2mA at rated voltage. Lightning impulse residual voltage of A's ZnO varistor suited standard characteristics, which is 3.85kV at 2.5kA, 4.4kV at 5kA and 5.16kV at 10kA. After multi lightning impulse residual voltage test of A's ZnO varistor exhibited good discharge characteristics which ZnO varistor reveals no evidence of puncture, flashover, cracking in visual examination. After high current impulse test of A's ZnO varistor exhibited good discharge characteristics, which variation rate of residual voltage is 0.4% before and after test, and revealed no evidence.

  • PDF

토중방전을 수반하는 접지봉의 임펄스응답에 대한 기초적 연구 (A Fundamental Study on the Impulse Responses of Ground Rod Attendant upon Soil Discharges)

  • 유양우;조성철;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권4호
    • /
    • pp.62-69
    • /
    • 2014
  • This paper deals with the fundamental characteristics of transient and conventional ground impedances associated with soil discharges when the lightning impulse voltage was applied to a small-sized ground rod. The potential rise responses of the test ground rod to impulse currents were observed. The current-voltage (I-V)curves, transient and conventional ground impedance curves were examined.. To analyze the transient behaviors of ground rod attendant upon soil discharges, the impulse responses of ground rod were compared with those of non-inductive resistor. As a consequence, the potential rise and impedance of ground rod were reduced and the currents dispersed into the earth were increased due to soil discharges near the ground rod. Soil discharges are classified into two regimes; ionization and breakdown phenomena. The potential rise and impulse impedance of ground rod are significantly decreased by breakdown processes in soil.

고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구 (An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse)

  • 송화영;주경민;이동훈;강내국;정낙헌
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF