• Title/Summary/Keyword: Impulse Density

Search Result 113, Processing Time 0.025 seconds

Impulse Noise Removal Using Noise Detector and Total Variation Optimization (잡음 검출기와 총변량 최적화를 이용한 영상의 임펄스 잡음제거)

  • Lee Im-Geun
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.4
    • /
    • pp.11-18
    • /
    • 2006
  • A new algorithm for removing salt and pepper impulse noise in image using impulse noise detector and total variation optimization is presented. The proposed two types of noise detectors which are based on the adaptive median filter, can detect impulse noise with high accuracy while reducing the probability of detecting image details as impulses. And the detectors maintain its performance independent of noise density. For removing impulses, total variation optimization is applied only to those detected noise candidate to reduces unnecessary computation. The proposed approach successfully remove impulse noise while preserving image details.

  • PDF

A Circuit of Capacitor-Discharge Impulse Magnetizer and Magnetizing Characteristics of Ferrite Magnet (커패시터 방전 임펄스 착자기 회로와 페라이트 자석의 착자특성)

  • Baek, Su-Hyeon;Yun, Su-Bong;Kim, Pil-Su
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.645-648
    • /
    • 1992
  • In a capacitor-discharge impulse magnetizer, one of the magnetic application system, a magnet is magnetized by the discharging current of capacitors. The conventional design of the magnetizer has been based on many year's experience. The behaviour of flux in the magnetizer should be calculated in order to produce the desired magnets. The analysis of the flux distribution is quite difficult. This is because both the magnetizing current and the applied voltage to the magnetizer are unknown. This paper describes the development of computer model for a capacitor-discharge impulse magnetizer using SPICE. Also, the detailed distribution of the flux density in a magnet magnetized by the impulse magnetizer be analyed.

  • PDF

EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME (관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구)

  • Lee Byeong Do;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가)

  • Cho, Han-Goo;Yun, Han-Soo;Kim, Seok-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

An Improved Adaptive Median Filter for Impulse Noise Removal (임펄스 잡음 제거를 위한 개선된 적응 메디안 필터)

  • Long, Xu;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.989-995
    • /
    • 2013
  • Image degradation caused by the impulse noise is generated in the process of image transmission and so on. It has been studied by many researchers in order to remove these noise. The representative impulse noise removal method includes SM filter. Though SM filter will indicate errors by the increasing of impulse noise density. Therefore, in this paper, in order to preserve the edges of the image, and reduce the distortion of the image, an improved adaptive median filter algorithm is proposed. In the simulation results, the algorithm showed excellent results in all several areas, and the PSNR is used as the criterion of evaluation.

Neural-network-based Impulse Noise Removal Using Group-based Weighted Couple Sparse Representation

  • Lee, Yongwoo;Bui, Toan Duc;Shin, Jitae;Oh, Byung Tae
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.8
    • /
    • pp.3873-3887
    • /
    • 2018
  • In this paper, we propose a novel method to recover images corrupted by impulse noise. The proposed method uses two stages: noise detection and filtering. In the first stage, we use pixel values, rank-ordered logarithmic difference values, and median values to train a neural-network-based impulse noise detector. After training, we apply the network to detect noisy pixels in images. In the next stage, we use group-based weighted couple sparse representation to filter the noisy pixels. During this second stage, conventional methods generally use only clean pixels to recover corrupted pixels, which can yield unsuccessful dictionary learning if the noise density is high and the number of useful clean pixels is inadequate. Therefore, we use reconstructed pixels to balance the deficiency. Experimental results show that the proposed noise detector has better performance than the conventional noise detectors. Also, with the information of noisy pixel location, the proposed impulse-noise removal method performs better than the conventional methods, through the recovered images resulting in better quality.

Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, You-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

Impulse Noise Removal using Switching Mean Filter (스위칭 평균 필터를 이용한 임펄스 잡음 제거)

  • Kim, Kuk-Seung;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.477-481
    • /
    • 2009
  • In this paper the process of transmitting images signal restore to image corrupted by impulse noise proposed switching mean filter. these filter is differential size using the two state noise detection distinguishes noise pixel and noise free pixel. Follow the detected impulse noise density in the image remove the impulse noise using switching mean filter these substituted pixel in order to non-recursive and recursive form from control process of the next pixel comes to be used with neighbor pixel process. Through the simulation, we compared with the existing methods and capabilties.

  • PDF

ENTRAINMENT OF SEDIMENT PARTICLES FROM SCOUR HOLE BY TURBULENT VORTICES DOWNSTREAM OF HYDRAULIC STRUCTURE

  • Kim, Jin-Hong;Lee, Sam-Hee
    • Water Engineering Research
    • /
    • v.2 no.4
    • /
    • pp.261-268
    • /
    • 2001
  • This study presents the estimation of the entrainment velocity of sediment particles from the scour hole. Sediment particles are entrained from the scour hole downstream of hydraulic structures by the turbulent vortices. Mathematical form of the entrainment velocity of sediment particles from the scour hole was obtained using the impulse-momentum equation with given value of the vertical component of turbulent velocity of the line vortex. Also, its probability density distribution was obtained with the results that the probability density distribution of the vertical turbulent velocity followed the normal distribution. Experimental results of the entrainment velocity of sediment particles showed relatively good agreements with theoretical ones.

  • PDF

Treeing characteristics in LDPE Added with Aromatic Compounds (방향족 화합물이 첨가된 저밀도 폴리에틸렌의 Treeing 특성)

  • Shin, T.S.;Park, Y.G.;Park, C.H.;Jang, D.U.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1481-1483
    • /
    • 1998
  • we have investigated the effect of aromatic compounds and tree inception and growth in low density polyethylene, for AC voltage and Impulse voltage. 2kinds of aromatic compounds are selected. Each additive (m-cresol, aniline) was mixed in low density polyethylene. For AC voltage, 10wt% $\sim$ 15wt% m-cresol can be shown to be the effective inhibitor to tree initiation. But, For Impulse voltage, 10wt% $\sim$ 15wt% aniline is effective inhibitor to tree initiation.

  • PDF