• 제목/요약/키워드: Impulse Current

검색결과 369건 처리시간 0.027초

두 평행한 관의 출구로부터 방출되는 펄스파에 관한 연구 (A Study of the Impulse Wave Discharged from the Exit of Two Parallel Tubes)

  • 권용훈;김희동;이동훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.151-154
    • /
    • 2002
  • The twin impulse wave leads to very complicated flow fields, such as Mach stem, spherical waves, and vortex ring. The twin impulse wave discharged from the exits of the two tubes placed in parallel is investigated to understand detailed flow physics associated with the twin impulse wave, compared with those in a single impulse wave. In the current study, the merging phenomena and propagation characteristics of the impulse waves are investigated using a shock tube experiment and by numerical computations. The Harten-Yee's total variation diminishing (TVD) scheme is used to solve the unsteady, two-dimensional, compressible, Euler equations. The Mach number $M_{s}$, of incident shock wave is changed below 1.5 and the distance between two-parallel tubes, L/d, is changed from 1.2 to 4.0. In the shock tube experiment, the twin impulse waves are visualized by a Schlieren optical system for the purpose of validation of computational work. The results obtained show that on the symmetric axis between two parallel tubes, the peak pressure produced by the twin-impulse waves and its location strongly depend upon the distance between two parallel tubes, L/d and the incident shock Mach number, $M_{s}$. The predicted Schlieren images represent the measured twin-impulse wave with a good accuracy.

  • PDF

가변주파수 및 임펄스 전류를 이용한 과도접지임피던스 분석 (An Analysis Method for the Transient Ground Impedance Using Variable Frequency and Lightning Impulse Current)

  • 엄주홍;조성철;이태형
    • 조명전기설비학회논문지
    • /
    • 제22권6호
    • /
    • pp.100-108
    • /
    • 2008
  • 접지전극의 형태, 크기, 재질 및 임펄스전류의 형상에 따라 변화하는 과도접지임피던스는 접지시스템의 성능에 중요한 영향을 미친다. 본 논문은 기존의 실효임펄스임피던스가 실제 과도접지임피던스를 얼마나 효과적으로 나타내고 있는가에 대한 분석과 보다 효과적인 과도접지임피던스 평가방법에 대하여 실험적인 결과를 제시하였다. 실험에 사용된 접지전극은 저항성분과 인덕턴스를 포함한 모의 접지전극과 1[m] 탄소접지봉, 9[m] 일반동봉 그리고 40[m] 매설지선이며, 가변주파수 전류와 임펄스전류에 의한 접지임피던스를 각각 측정하였다. 각각의 값을 비교 했을 때 기존의 실효임펄스임피던스의 값보다는 전압의 최대 값과 전류의 최대 값을 이용하여 과도접지임피던스를 구한 임피던스 값($Z_1$)이 등가주파수에 해당하는 가변주파수 전류에 의해 구해진 접지임피던스에 근접함을 확인하였다.

Study on the Transfer Functions for Detecting Windings Displacement of Power Transformers with Impulse Method

  • Shon, Chae-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.876-883
    • /
    • 2012
  • The paper investigates three types of transfer function methods for detecting displacements of winding in a model transformer. To acquire these transfer functions, the measuring method of input voltage, current and its response is used in impulse method. The applied impulse voltages had three rising times, which were short rising time (less than 0.6 ${\mu}s$), medium rising time (about 0.8 ${\mu}s$) and long rising time (about 1 ${\mu}s$) in front waves. Every 10 measurements of voltage and current waves were averaged from 50 measurements of voltage and current waves. These transfer functions were tested in normal, 24mm elevated and 48mm elevated windings conditions and were analyzed with correlation coefficients and spectrum deviations. In the analysis, the results depend on the types of transfer functions and the rising times of input voltages.

침상 접지봉의 임펄스접지임피던스에 미치는 지중방전의 영향 (Effects of Soil Discharges on the Impulsive Ground Impedance of Ground Rod with Needles)

  • 유양우;조성철;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권5호
    • /
    • pp.98-105
    • /
    • 2014
  • Soil discharges near the ground rod play an important role to reduce the ground potential rise and the ground impedance and to help the fault current to spread into the earth. This paper presents the effects of soil discharges on the transient and conventional ground impedances when the lightning impulse voltage was applied to a ground rod with radial needles. The current-voltage (I-V)curves and transient ground impedance curves were calculated based on the measured current and potential traces. Soil discharge behaviors related to I-V curves and transient ground impedance curves were analyzed as a function of the magnitude of lightning impulse voltages. As a result, the soil discharges occurred near the ground electrode contribute to the reduction of conventional ground impedance and limits the ground potential rise effectively under lightning impulse voltages.

복합차체의 낙뢰에 대한 인체 안전성 분석 (Safety Analysis for Passengers of Composite Car-body against Lightning Strikes)

  • 길경석;박대원;김성욱;박찬용;조영진
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.526-531
    • /
    • 2009
  • In this paper, the safety for passengers of composite car-body against lightning strikes was analyzed by the application of an impulse generator which can produce impulse current up to 50 kA with 8/$20{\mu}s$ waveform. Potential difference on inside surface of the car-body was measured as a safety parameter for the passengers against lightning strikes. The potential difference between 20 em distant was 175 V at 37.67 kA, and it corresponds to 875 V between 1 m distant. The amount of charge flowing a passenger at 100 kA impulse current can be estimated to $0.31\;mA{\cdot}s$. This is much less than the limit amount of charge for human body, $30\;mA{\cdot}s$ which is presented by Koeppen and Osypka.

뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화 (Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test)

  • 이복희;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF

다공관으로부터 방출되는 펄스파에 관한 연구 (A Study of the Impulse Wave Discharged from a Perforated Pipe)

  • 신현동;권용훈;김희동
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2003년도 추계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2003
  • When a shock wave discharges from an open end of a duct, an impulse wave is generated outside the duct, causing serious noise and vibration problems. The magnitude of the impulse wave can be reduced by installing of a perforated duct. In the current study, the characteristics of the impulse wave discharged from the exit of a perforated duct are numerically investigated. A TVD (total variation diminishing) scheme is used to solve the unsteady, axisymmetric, compressible Euler equations. In computations, the porosity of a perforated pipe $(\sigma)$ and the Mach number of incident shock wave $(M_s)$ are varied in the range of $\sigma=0\~19\%\;and\;M_s=1.01\~1.50$, respectively. The results show that the directivity and magnitude of impulse wave strongly depend upon the Mach number of incident shock wave and the porosity of the perforated pipe. The present CFD results are in close agreement with experimental results.

  • PDF

EFFICIENT DESIGN OF CAPACITOR DISCHARGE IMPULSE MAGNETIZER SYSTEM FOR 8-POLE MAGNET

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.828-832
    • /
    • 1995
  • This paper describes the efficient design, analysis method and experimental verification of capacitor discharge impulse magnetizer system. A capacitor discharge magnetizer system is used to produce a high current impulse of short duration in this magnetizing fixture. The parasitic resistance and parasitic inductance of the capacitor discharge impulse magnetizer system have been estimated using known air-core test coil. Finite element analysis (using MAXWELL 2-D field simulator) and magnetizing circuit analysis (using SPICE) are also used as part of the design and analysis process of the capacitor discharge impulse magnetizer system. Application study for a magnetizing fixture design is shown. 8-pole magnetizing fixture has been designed and analyzed using finite element analysis. The fixture design for 8-pole magnet are presented along with the experimental results. The experimental results have been achieved using a high-voltage, high-energy capacitor discharge impulse magnetizer and 8-pole iron core fixtures (charging voltage : 2000[V], capacitor bank : 4000[$\mu\textrm{F}$]).

  • PDF

인지폐합수요(认知闭合需要), 심리건강화사회인소대충동구매적영향(心理健康和社会因素对冲动购买的影响) (The Impacts of Need for Cognitive Closure, Psychological Wellbeing, and Social Factors on Impulse Purchasing)

  • Lee, Myong-Han;Schellhase, Ralf;Koo, Dong-Mo;Lee, Mi-Jeong
    • 마케팅과학연구
    • /
    • 제19권4호
    • /
    • pp.44-56
    • /
    • 2009
  • 冲动购买是指一个没有预先购物意向的立即购买. 以往对冲动购买的研究主要集中于和营销组合变量, 环境因素, 消费人口和特征相关的因素. 在以前的研究中, 营销组合变量如产品种类, 产品类型和氛围, 包括广告, 优惠券, 销售活动, 促销刺激销售点, 和媒体格式都已被用于评估产品信息. 有些作者还着重围绕消费者的情境因素. 如信用卡的使用, 时间, 产品运输性, 发现购物同伴的存在和数量对冲动购买/冲动趋势有积极的影响. 研究也已评估了个体特征的影响, 如年龄, 性别, 以及消费者的教育程度, 以及拥挤的感知, 刺激和接触的需要等因素对冲动购买的影响. 概括来说, 以前的研究发现所有的产品都可以被冲动地购买(Vohs and Faber, 2007), 即环境因素可以影响或至少促使冲动购买行为. 最近新的分销渠道的推出, 例如家庭购物渠道, 折扣店和网上商店, 这些24小时都营业的形式增加了冲动购买的可能性. 然而, 以前的文献重点关注情境和营销变量, 因此这些研究所考虑的消费者的主要特征仍然是缺乏的. 为了弥补这个缺陷, 本研究根据研究的第三个惯例并关注个体特质变量, 这些是很少被研究的. 更具体地来说, 本研究探索了冲动购买趋势对冲动购买行为是否有积极的影响, 并评估了消费者特点例如认知闭合需要(NFCC), 心理健康和人际敏感性是如何影响消费者冲动购买的趋势. 这项调查结果显示, 消费者的情感冲动, 对冲动购买行为产生积极的影响, 而认知冲动并没有对冲动购买行为的影响. 此外, 情感冲动购买倾向是被认知闭合需要的构成因素所推动的, 如果断和模糊不适; 心理健康, 如环境控制和生活的目标, 以及规范和信息的影响. 此外, 认知冲动倾向是被认知闭合需要的构成因素所驱动的决断, 模棱两可的不适和密切的态度, 心理健康和环境控制, 以及规范性和信息的影响. 本研究具有重要理论意义. 第一, 情感冲动对冲动购买行为有巨大影响. 以前的研究根据情感和流动理论提出, 低到中等程度的冲动是自我控制减少或自我监管机制失败所造成的. 本研究证实了上述观点. 二, 本研究通过确认冲动购买趋势可以看做是情感和认知两个维度的二维概念, 并说明冲动购买行为主要是由情感冲动解释, 而不是认知冲动. 第三, 目前的研究有新的概念, 如在本研究的模型中作为潜在影响因子的心理健康和认知闭合需要, 从而对现有的文献做出了贡献. 通过多维概念例如心理健康和认知闭合需要, 有关消费者信息过程的多个方面可以被评估. 第五, 本研究通过确定规范和信息这两个竞争路线扩展了现有的文献. 规范影响发生在个人符合别人的期望或提高他们的自我形象时. 而信息的影响发生在个人搜索来自他人知识信息和观察他人行为之后的推论. 本研究显示了这两个相互竞争的社会影响力的路线, 可以归因于不同影响力的来源. 目前的研究也有许多实际的启示. 首先, 它表明, 公司应该更多关注其首要的目标, 有情感冲动的消费者. 这一方面公司可以创造更振奋精神的购物环境. 二, 目前的结果表明, 认知闭合需要与认知方面的冲动有密切相关的. 这些人是被不经意的想法所驱动的, 而不是感觉或兴奋. 在购买点理性的广告会吸引这些客户. 第三, 容易受规范性影响的消费群是另一个潜在的目标市场. 零售商和制造商, 通过宣传其产品和/或可用于识别或符合愿望组在对他人的期望的产品服务. 但是, 作为一个细分市场, 零售商应避免目标消费群易受信息的影响. 这些人对有关购买的产品服务进行了广泛的信息搜索, 因此更详细, 长期理性的广告信息可以内化这些消费者的思想过程. 本文的结果有几个原因应慎重解释. 这项研究采用了数量较少的便利样本, 而且只调查了两个维度的行为. 为此, 今后的研究应包括更多样化特点和衡量行为的不同方面的样本. 未来的研究还应该调查与情感作用理论密切相关的个性特征. 在以后的研究中, 特征变量会是很另人感兴趣的领域, 如感觉的好奇, 人际敏感性的好奇心, 和气氛反应.

  • PDF

$SF_6-N_2$ 혼합가스에서 과도임펄스전압에 대한 V-t특성 (V-t Characteristics in $SF_6-N_2$ Mixtures for Transient Impulse Voltages)

  • 이복희;이경옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.456-465
    • /
    • 2001
  • In this paper, breakdown voltages in $SF_6-N_2$ mixtures were experimentally investigated to understand characteristics of dielectric strength and physical phenomena in nonuniform field disturbed by a needle shape protrusion. The test voltages are the lightning impulse$(\pm1.2/44 \mus)$ and the damped oscillatory impulse$(\pm400 ns / 0.83 MHz)$ voltages which can be occurred by the operation of disconnecting switches in gas-insulated switchgears(GIS). The effects of the polarity and wave shape of the test voltages, and the gas pressure on the V-t characteristics were in detail examined. The V-t characteristic curves were measured in different two ways : (1) one is the method by taking the maximum voltage recorded at or prior to breakdown against the time to breakdown, that is, the Procedures recommended in IEC 60060-1, (2) the other is the method by taking the voltage at the instant of chopping against the time to breakdown. As a result, the V-t characteristics of $SF_6-N_2$ mixtures in nonuniform electric field were significantly affected by the polarity and wave shape of the applied voltages. The positive breakdown voltages resulted in lower breakdown voltages in the time ranges considered, and the V-t curves for the negative oscillatory impulse voltage were extended over the longer time range. For the lightning impulse voltages, the V-t curves obtained by IEC Pub. 60060-1 were nearly same with the V-t curves obtained by the voltage at the instant of chopping against the time to breakdown. It is clear that the actual breakdown voltages were much lower than the maximum voltages appearing at or prior to breakdown because of the displacement current produced as a result of the dV/dt during the oscillatory transient voltage app1ication. The scattering of the negative actual breakdown voltages was much larger than that of the positive.

  • PDF