• Title/Summary/Keyword: Improvement of Sensitivity

Search Result 742, Processing Time 0.039 seconds

Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique (마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상)

  • Kim D.I.;Huh Y.H.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

Effect of red ginseng on visual function and vision-related quality of life in patients with glaucoma

  • Lee, Kwanghyun;Yang, Heon;Kim, Joo Yeon;Choi, Wungrak;Seong, Gong Je;Kim, Chan Yun;Lee, Jun Mo;Bae, Hyoung Won
    • Journal of Ginseng Research
    • /
    • v.45 no.6
    • /
    • pp.676-682
    • /
    • 2021
  • Background: Red ginseng has been found to improve ocular perfusion and dry eye syndrome in glaucomatous eyes; however, its effects on visual function and vision-related quality of life have not been investigated. This study sought to evaluate the effects of red ginseng on visual function and vision-related quality of life in glaucoma patients using contrast sensitivity and a questionnaire. Methods: Participants were randomly assigned to two groups in this prospective, randomized, double-blind study: in one group, red ginseng was taken first, followed by a placebo, and in the other, placebo was taken first, followed by red ginseng. We measured and compared changes in contrast sensitivity and vision-related quality of life between the two groups. Contrast sensitivity was measured using OPTEC® 6500P, and vision-related quality of life was evaluated using the 25-item National Eye Institute Visual Function Questionnaire. One-way and two-way repeated measure analyses of variance were used for the comparison. Relationships between respective changes in dry eye syndrome and contrast sensitivity were also analyzed. Results: Daytime contrast sensitivity and ocular pain improved after the administration of red ginseng. Nighttime contrast sensitivity was improved in early or moderate glaucoma. Improved contrast sensitivity was not associated with improvement in dry eye syndrome. Conclusion: Red ginseng could improve contrast sensitivity and ocular pain in patients with glaucoma. The mechanism underlying improvement in contrast sensitivity appears to be associated with enhanced retinal perfusion or retinal ganglion cell function, but not dry eye syndrome.

EFFECTS OF ANTHOCYANOSIDE OLIGOMER ON MESOPIC CONTRAST SENSITIVITY IN MILD TO MODERATE MYOPIA

  • Seong Gong Je
    • Proceedings of the Korean Society of Food Science and Nutrition Conference
    • /
    • 2001.12a
    • /
    • pp.52-60
    • /
    • 2001
  • Purpose: We performed a randomized, double-blind, placebo-controlled trial in mild to moderate myopia patients to evaluate the benefit of taking a nutrient supplement containing anthocyanoside oligomers for improving nocturnal visiual function and/or clinical symptoms. Methods: The subjects included have refractive error between -lD(Diopters) $\~$-8D in both eyes, symptoms of decreased night vision and asthenopia based on the scoring result of a pre-structured questionnaire, and abnormal results of mesopic contrast sensitivity(MCS) screening test showing abnormal curve of contrast sensitivity in the middle and high frequency level, between 6.0 and 30.0 CPD(Cycles per degree) at mesopic condition(-2$\~$0 log cd/$m^2$). Total 60 people who qualified the criteria above were enrolled and the subjects were instructed to take the investigational product (anthocyanoside or placebo) twice daily for a 4 week period. The enrolled subjects were investigated for nocturnal vision performance by MCS and clinical symptoms at their first visit and re-evaluated at post-intervention (4 weeks later). MCS was measured and improvement of contrast threshold level according to each CPD was calculated by subtracting initial values from final values. Age, refractive error, and MCS were compared between the placebo and anthocyanoside. Results: After 4 weeks of drug administration 22 of the anthocyanoside group showed symptom improvement compared to 1 of the placebo group (p=0.000). Contrast sensitivity levels according to each CPD before and after drug treatment showed significant improvement in the anthocyanoside group but not in the placebo group. Mean MCS change of anthocyanoside group is 2.41$\pm$1.91 which showed significant improvement compared to -0.40$\pm$2.47 of the placebo group(p=0.000). MCS changes of anthocyanoside group showed significant improvement compared to placebo group in all levels of CPD(p<0.05). During our investigation none of the subjects complained of specific side effects related to anthocyanoside use. Conclusion: Our results show that under careful selection of people with significant symptoms and definite MCS abnormalities, anthocyanoside oligomers may improve the subjective symptoms and objective MCS results.

  • PDF

Design Improvement to a Research Reactor for Safety Enhancement using PSA (PSA를 이용한 연구용 원자로 안전성 향상 방안 도출)

  • Lee, Yoon-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.157-163
    • /
    • 2018
  • This paper describes design improvement to a research rector for safety enhancement using Probabilistic Safety Assessment (PSA). This PSA under reactor design was undertaken to assess the level of safety for the design of a research reactor and to evaluate whether it is probabilistically safe to operate and reliable to use. The scope of the PSA reported here is a Level 1 PSA, which addresses the risks associated with the core damage. The technical objectives of this study were to identify accident sequences leading to core damage and to derive design improvement from the dominant accident sequences through the sensitivity analysis. The AIMS-PSA and FTREX were used for the this PSA of the research reactor. The criterion for inclusion was all sequences with a point estimate frequency greater than a truncation value of 1.0E-14/yr. The final result indicates a point estimate of 6.79E-05/yr for the overall Core Damage Frequency (CDF) attributable to internal initiating events for the research reactor under design. Based on the dominant accident sequences from the PSA, the seven kinds of sensitivity analysis were performed and some design improvement items were derived. When the five methods to improve the safety were all applied to the reactor design and emergency operating procedure, its risk was reduced to about 1.21E-06/yr from 6.79E-05/yr. The contribution of LOCA and LOEP with high CDF were significantly reduced by the sensitivity analysis. The safety of the research reactor was well improved and the risk was reduced than before adapting the design improvement gotten from the sensitivity analysis. The present study indicated that the research reactor has the well-balanced safety in regard to each initiating event contribution to CDF. The PSA methodology is very effective to improve reactor safety in a conceptual design phase and especially, Risk-informed design(RID) is very nice way to find the deficiencies of research reactor under design and to improve the reactor safety by solving them.

A Study on the Sensitivity Analysis of GERT Network (GERT Network의 감도분석(感度分析)에 관한 고찰(考察))

  • Lee, Sang-Do;Jeong, Jung-Hui;Park, Gi-Ju
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.9 no.2
    • /
    • pp.47-53
    • /
    • 1983
  • In this paper, a sensitivity analysis is proceeded to improve the network of manufacturing process by converting the qualitative network into GERT Network and by finding equivalent probability, MFG's of variables and sensitivity equation in GERT Network. Sensitivity analysis of GERT Network is important in evaluating, reviewing and improving system. System improvement in GERT Network is achieved by increasing the equivalent probability and by decreasing the equivalent time.

  • PDF

Sensitivity improvement of fiber-optic gyroscope with erbium-doped fiber source by source excess noise subtraction (Erbium 첨가 광섬유 광원을 사용하는 자이로스코프에서 광원 과잉잡음 소거에 의한 측정감도 개선)

  • 진영준
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1999.08a
    • /
    • pp.226-227
    • /
    • 1999
  • In the fiber-optic gyroscope employing the erbium-doped fiber source, the source excess noise was subtracted through a signal processing to improve the gyroscope sensitivity . As the result, we obtained the improvement of 14 dB(electrical) at the proper frequency, which was measured from the noise floor spectrum . In addition the random walk coefficient in the gyro output was reduced by about factor of three.

  • PDF

Design Sensitivity Analysis of Eigen Problem Using NASTRAN (NASTRAN을 이용한 고유치 문제의 설계 민감도 해석)

  • 윤광수;이태희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.508-512
    • /
    • 1997
  • Design sensitivity analysis of Eigen Problem give systematic design improvement information for noise and vibration of a system. Based on reliable results form commercial FE code(UAI/NASTRAN), three computational procedures for design sensitivity analysis of eigen problem are suggested. Those methods are finite difference,design sensitivity analysis using external module and design sensitivity analysis running with NASTRAN. To verify the suggested methods, a numerical example is given and these results are compared with the results from UAI/NASTRAN eigen sensitivity option. We can conclude that design sensitivity coefficient of eigen proplems can be computed outside of the FE code as easy as inside of the FE code.

  • PDF

The Effect of the Experience-based Ecology-Environmental STEAM Program on Ecological Sensitivity of Elementary Students (체험중심 생태환경 초등학생들의 생태적 감수성에 미치는 영향)

  • Kim, Sunil;Shin, Youngjoon
    • Journal of Korean Elementary Science Education
    • /
    • v.38 no.4
    • /
    • pp.465-474
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the experience-based ecology-environmental STEAM education on ecological sensitivity of elementary students. The research subjects were 62 third graders of S elementary school located in Incheon. They were divided into the experimental group of 33 students and the comparative group of 29 students. The experimental group was provided the educational program with the experience-based ecology-environmental STEAM education. The comparative group was provided the theoretical and ecological self activity program based on the textbook. The results of this study can be summarized as follows; First, the experience-based ecology-environmental STEAM education had a meaningful effect on improvement of ecological sensitivity. Second, we found that access to the ecological environment education is important in all subjects, not in education that is biased toward. Third, in ecological environment education, experience-oriented education methods are more meaningful than indirect experiences trapped in textbooks. Fourth, ecological environment education can contribute to the improvement of ecological sensitivity as well as the intellectual aspect of ecology and environmental science. In conclusion, it was found that the ecological environment program should be conducted with activities of experience.

Kinematic Design Sensitivity Analysis of Suspension systems Using Direct differentiation (직접미분법을 이용한 현가장치의 기구학적 민감도해석)

  • 민현기;탁태오;이장무
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.1
    • /
    • pp.38-48
    • /
    • 1997
  • A method for performing kinematic design sensitivity analysis of vehicle suspension systems is presented. For modeling of vehicle suspensions, the multibody dynamic formulation is adopted, where suspensions are assumed as combination of rigid bodies and ideal frictionless joints. In a relative joint coordinate setting, kinematic constraint equations are obtained by imposing cut-joints that transform closed-loop shape suspension systems into open-loop systems. By directly differentiating the constraint equations with respect to kinematic design variables, such as length of bodies, notion axis, etc., sensitivity equations are derived. By solving the sensitivity equations, sensitivity of static design factors that can be used for design improvement, can be obtained. The validity and usefulness of the method are demonstrated through an example where kinematic sensitivity analysis of a MacPherson strut suspension of performed.

  • PDF

Sensitivity Improvement and Operating Characteristics Analysis of the Pressure Sensitive Field Effect Transistor(PSFET) Using Highly-Oriented ZnO Piezoelectric Thin Film

  • Lee, Jeong-Chul;Cho, Byung-Woog;Kim, Chang-Soo;Nam, Ki-Hong;Kwon, Dae-Hyuk;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.180-187
    • /
    • 1997
  • We demonstrate the improvement of sensitivity and analysis of operating characteristics of the piezoelectric pressure sensor using ZnO piezoelectric thin film and FET(field effect transistor) for sensing applied pressure and transforming the pressure into electrical signals, respectively. The sensitivity of the PSFET(pressure sensitive field effect transistor) was improved by using highly-oriented ZnO film perpendicular to the substrate surface and the operating characteristics was investigated by monitoring output voltage with time in various static pressure levels.

  • PDF