• Title/Summary/Keyword: Improved PD

Search Result 224, Processing Time 0.026 seconds

Effects of (-)-Sesamin on Memory Deficits in MPTP-lesioned Mouse Model of Parkinson's Disease

  • Zhao, Ting Ting;Shin, Keon Sung;Lee, Myung Koo
    • Natural Product Sciences
    • /
    • v.22 no.4
    • /
    • pp.246-251
    • /
    • 2016
  • This study investigated the effects of (-)-sesamin on memory deficits in 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-lesioned mouse model of Parkinson's disease (PD). MPTP lesion (30 mg/kg/day, 5 days) in mice showed memory deficits including habit learning memory and spatial memory. However, treatment with (-)-sesamin (25 and 50 mg/kg) for 21 days ameliorated memory deficits in MPTP-lesioned mouse model of PD: (-)-sesamin at both doses improved decreases in the retention latency time of the passive avoidance test and the levels of dopamine, norepinephrine, 3,4-dihydroxyphenylacetic acid, and homovanillic acid, improved the decreased transfer latency time of the elevated plus-maze test, reduced the increased expression of N-methyl-D-aspartate (NMDA) receptor, and increased the reduced phosphorylation of extracellular signal-regulated kinase (ERK1/2) and cyclic AMP-response element binding protein (CREB). These results suggest that (-)-sesamin has protective effects on both habit learning memory and spatial memory deficits via the dopaminergic neurons and NMDA receptor-ERK1/2-CREB system in MPTP-lesioned mouse model of PD, respectively. Therefore, (-)-sesamin may serve as an adjuvant phytonutrient for memory deficits in PD patients.

Improved Stability of GaN-based Hydrogen Sensor with SnO2 Nanoparticles/Pd Catalyst Layer Using UV Illumination (자외선 조사를 이용한 SnO2 나노입자/Pd 촉매층을 갖는 GaN 기반 수소 센서의 안정성 개선 연구)

  • Won-Tae Choi;Hee-Jae Oh;Jung-Jin Kim;Ho-Young Cha
    • Transactions on Semiconductor Engineering
    • /
    • v.1 no.1
    • /
    • pp.9-13
    • /
    • 2023
  • An AlGaN/GaN heterojunction-based hydrogen sensor with SnO2 nanoparticles/Pd catalyst layer was fabricated for room-temperature hydrogen detection. The fabricated sensor exhibited unstable drift in standby current when it was operated at room temperature. The instability in the sensing signal was dramatically improved when the sensor was operated under UV illumination.

Effect of Plasma Etching and $PdCl_2/SnCl_2$ Catalyzation on the Performance of Electroless Plated Copper Layer (플라즈마 에칭 및 $PdCl_2/SnCl_2$ 촉매조건이 무전해 동도금 피막의 성능에 미치는 영향)

  • 오경화;김동준;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.7
    • /
    • pp.843-850
    • /
    • 2003
  • Cu/PET film composites were prepared by electroless copper plating method. In order to improve adhesion between electroless plated Cu layer and polyester (PET) film, the effect of pretreatment conditions such as etching method, mixed catalyst composition were investigated. Chemical etching and plasma treatment increased surface roughness in decreasing order of Ar>HCl>O$_2$>NH$_3$. However, adhesion of Cu layer on PET film increased in the following order: $O_2$<Ar<HCl<NH$_3$. It indicated that appropriate surface roughness and introduction of affinitive functional group with Pd were key factors of improving adhesion of Cu layer. PET film was more finely etched by HCI tolution, resulting in an improvement in adhesion between Cu layer and PET film. Plasma treatment with NH$_3$produced nitrogen atoms on PET film, which enhances chemisorption of Pd$^{2+}$ on PET film, resulting in improved adhesion and shielding effectiveness of Cu layer deposited on the Pd catalyzed surface. Surface morphology of Cu plated PET film revealed that Pd/Sn colloidal particles became more evenly distributed in the smaller size by increasing the molar ratio of PdCl$_2$; SnCl$_2$from 1 : 4 to 1 : 16. With increasing the molar ratio of mixed catalyst, adhesion and shielding effectiveness of Cu plated PET film were increased.d.

Al Doping Effect of Pd/TiO2 for Improved Hydrogen Detection (수소 감지 성능 향상을 위한 Pd/TiO2 분말에서의 Al 도핑 효과)

  • Lee, Yeongan;Seo, Hyungtak
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.207-210
    • /
    • 2014
  • $TiO_2$ oxide semiconductor is being widely studied in various applications such as photocatalyst and photosensor. Pd/$TiO_2$ gas sensor is mainly used to detect $H_2$, CO and ethanol. This study focus on increasing hydrogen detection ability of Pd/$TiO_2$ in room temperature through Al-doping. Pd/$TiO_2$ was fabricated by the hydrothermal method. Contacting to Aluminum (Al) foil led to Al doping effect in Pd/$TiO_2$ by thermal diffusion and enhanced hydrogen sensing response. $TiO_2$ nanoparticles were sized at ~30 nm of diameter from scanning electron microscope (SEM) and maintained anatase crystal structure after Al doping from X-ray diffraction analysis. Presence of Al in $TiO_2$ was confirmed by X-ray photoelectron spectroscopy at 73 eV. SEM-energy dispersive spectroscopy measurement also confirmed 2 wt% Al in Pd/$TiO_2$ bulk. The gas sensing test was performed with $O_2$, $N_2$ and $H_2$ gas ambient. Pd/Al-doped $TiO_2$ did not response $O_2$ and $N_2$ gas in vacuum except $H_2$. Finally, the normalized resistance ratio ($R_{H2on}/R_{H2off}$) of Pd/Al-doped $TiO_2$ increases about 80% compared to Pd/$TiO_2$.

Usage Patterns and Incidence of Thyroid-related Adverse Events in Patients Treated with PD-1 Inhibitors (PD-1 억제제의 사용패턴 및 갑상선 관련 유해사례 발현 양상 분석)

  • Hwang, Seoyoung;Kim, Heuijae;Chung, Seonyoung;Min, Myungsook;Suh, Dong-Churl
    • Korean Journal of Clinical Pharmacy
    • /
    • v.31 no.3
    • /
    • pp.188-197
    • /
    • 2021
  • Objective: PD-1 inhibitors have demonstrated improved health outcomes in cancer patients. PD-1 inhibitors are well-tolerated and associated with immune-related adverse events. The objectives of this study are to analyze use patterns of PD-1 inhibitors in patients with cancer and to investigate the incidence of thyroid-related adverse reactions in patients treated with PD-1 inhibitors. Methods: The study included patients who had been administered PD-1 inhibitors (either nivolumab or pembrolizumab) at the Samsung Medical Center between October 1, 2016 and June 30, 2017. Data was collected from electronic medical records and tested using Mann-Whitney tests and Chi-Square tests for statistical significance. Associations between PD-1 inhibitors and incidence of adverse events were tested using Cox regression for age, gender, BMI, ECOG PS and medication. Results: Two hundred fifteen patients were identified as eligible for analyses. Thyroid-related adverse events occurred in 20% of patients (n=43). Thyroid function tests (TFTs) was performed in 109 patients (50.7%). Positive results of PD-L1 testing were found in 53.2% of the 94 patients who had the test. Approved doses of nivolumab (3 m/kg) and pembrolizumab (200 mg) were administered in 70.4% and 53% of patients, respectively. The analysis of risk factor of thyroid-related adverse reaction did not show statistically significant differences (Cox regression). Conclusion: Thyroid-related adverse events are common in patients treated with PD-1 inhibitors and hypothyroidism is the most frequent adverse reaction. Routine TFTs monitoring is strongly recommended to evaluate thyroid function in real-world clinical practice.

The effect of lateral wedge on postural sway in Parkinson's disease

  • Yoon, Ji-Yeon;Park, Jinse;Park, Kang Min;Ha, Sam Yeol;Kim, Sung Eun;Shin, Kyong Jin;Kim, Si Eun;Jo, Geunyeol
    • Annals of Clinical Neurophysiology
    • /
    • v.20 no.1
    • /
    • pp.31-35
    • /
    • 2018
  • Background: Although postural instability is one of the major symptoms of Parkinson's disease (PD), dopaminergic treatment is ineffective for treating postural instability. Recent reports have shown that somatosensory deficit is associated with postural instability, and that somatosensory input improved postural instability. The purpose of this study is to evaluate the effects of lateral wedges for quiet standing postural control in people with PD. Methods: Twenty-two patients who were diagnosed with PD were enrolled in this study. The participants stood on a force plate under two conditions (wedge and no wedge) with or without having their eyes open or closed. The center of pressure (COP) range and velocity were analyzed using a two-way repeated-measures analysis of variance. Results: The range and velocity of COP in the anterioposterior and mediolateral (ML) directions were significantly improved after the patients stood on the lateral wedge with their eyes closed (p < 0.05). The range in ML direction and velocity in both directions of COP were significantly decreased when their eyes were open (p < 0.05). Conclusions: Regardless of vision, standing on lateral wedges improved postural sway in people with PD.

Development of Pd/TiO2 Catalysts with La2O3 Addition and Study on the Performance Improvement of H2 Oxidation at Room Temperature (La2O3가 첨가된 Pd/TiO2 촉매의 개발 및 H2 상온산화 반응에서의 성능 향상 연구)

  • Lee, Dong Yoon;Kim, Sung Chul;Lee, Sang Moon;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.674-678
    • /
    • 2020
  • In this study, a Pd/TiO2 catalyst which oxidized H2 at room temperature without an additional energy source was prepared. And a specific surface area of TiO2 as a support was not proportional to H2 oxidation reaction performance of Pd/TiO2 catalyst. In addition La2O3 was added to Pd/TiO2 catalyst in order to evaluate the performance effect due to the change of catalysts physical properties. A Pd/La2O3-TiO2 was prepared by adding different amounts of La2O3 to TiO2 and CO chemisorption analysis was performed. Compared to the conversion rate (14% at 0.5% H2) of the Pd/TiO2(G) catalyst, the Pd/La2O3-TiO2 catalyst showed 74% which was improved by more than five times. It was found that the larger the metal dispersion of Pd as an active metal is, the more favorable to H2 oxidation reaction is. However, when the added La2O3 amount exceeded 10%, the catalyst performance decreased again. Finally, it was concluded that the physical properties of the Pd/La2O3-TiO2 catalyst have a dominant influence on the catalytic activity until 0.3~0.5% of injected H2 concentrations and the catalyst reaction rate was controlled by substance transfer from 1% or more concentrations of H2.

Synthesis and Property of Carbon Nanotube-Supported Pd and Pt Nanoparticles (탄소나노 튜브위에 성장된 Pd 및 Pt 나노 입자의 제조 및 특성)

  • Kim, Hyung-Kun;Lee, Rhim-Youl
    • Korean Journal of Materials Research
    • /
    • v.19 no.4
    • /
    • pp.192-197
    • /
    • 2009
  • Carbon nanotubes (CNT) were used as a catalyst support where catalytically active Pd and Pt metal particles decorated the outside of the external CNT walls. In this study, Pd and Pt nanoparticles supported on $HNO_3$-treated CNT were prepared by microwave-assisted heating of the polyol process using $PdCl_2$ and $H_2PtCl_6{\codt}6H_2O$ precursors, respectively, and were then characterized by SEM, TEM, and Raman. Raman spectroscopy showed that the acid treated CNT had a higher intensity ratio of $I_D/I_G$ compared to that of non-treated CNT, indicating the formation of defects or functional groups on CNT after chemical oxidation. Microwave irradiation for total two minutes resulted in the formation of Pd and Pt nanoparticles on the acid treated CNT. The sizes of Pd and Pt nanoparticles were found to be less than 10 nm and 3 nm, respectively. Furthermore, the $SnO_2$ films doped with CNT decorated by Pd and Pt nanoparticles were prepared, and then the $NO_2$ gas response of these sensor films was evaluated under $1{\sim}5\;ppm$ $NO_2$ concentration at $200^{\circ}C$. It was found that the sensing property of the $SnO_2$ film sensor on $NO_2$ gas was greatly improved by the addition of CNT-supported Pd and Pt nanoparticles.

Highly Sensitive MEMS-Type Micro Sensor for Hydrogen Gas Detection by Modifying the Surface Morphology of Pd Catalytic Metal (Pd 촉매금속의 표면형상 변형에 의한 고감도 MEMS 형 마이크로 수소가스 센서 제조공정)

  • Kim, Jung-Sik;Kim, Bum-Joon
    • Korean Journal of Materials Research
    • /
    • v.24 no.10
    • /
    • pp.532-537
    • /
    • 2014
  • In this study, highly sensitive hydrogen micro gas sensors of the multi-layer and micro-heater type were designed and fabricated using the micro electro mechanical system (MEMS) process and palladium catalytic metal. The dimensions of the fabricated hydrogen gas sensor were about $5mm{\times}4mm$ and the sensing layer of palladium metal was deposited in the middle of the device. The sensing palladium films were modified to be nano-honeycomb and nano-hemisphere structures using an anodic aluminum oxide (AAO) template and nano-sized polystyrene beads, respectively. The sensitivities (Rs), which are the ratio of the relative resistance were significantly improved and reached levels of 0.783% and 1.045 % with 2,000 ppm H2 at $70^{\circ}C$ for nano-honeycomb and nano-hemisphere structured Pd films, respectively, on the other hand, the sensitivity was 0.638% for the plain Pd thin film. The improvement of sensitivities for the nano-honeycomb and nano-hemisphere structured Pd films with respect to the plain Pd-thin film was thought to be due to the nanoporous surface topographies of AAO and nano-sized polystyrene beads.

Highly Selective Amination of o- and p-Alkyl Phenols over Pd/Al2O3-BaO

  • Ma, Jianchao;Wang, Huabang;Sun, Meng;Yang, Fan;Wu, Zhiwei;Wang, Donghua;Chen, Ligong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.387-392
    • /
    • 2012
  • A series of Pd-based catalysts were prepared and examined for the amination of 2,6-dimethylphenol in a fixedbed reactor. The best results were obtained for Pd/$Al_2O_3$-BaO with a conversion of 99.89% and a selectivity of 91.16%. These catalysts were characterized using BET, XRD, XPS, TEM and $NH_3$-TPD. Doped BaO not only improved the dispersion of the Pd particles but also decreased the acidity of the catalyst, which remarkably enhanced the selectivity and stability of the catalyst. The generality of Pd/$Al_2O_3$-BaO for this kind of reaction was demonstrated by catalytic aminations of o- and p-alkyl phenols.