• Title/Summary/Keyword: Impression surface

Search Result 117, Processing Time 0.02 seconds

A Case Study on Thermal Performance for Transparent Glazing Space Considering Solar Radiation in Summer (여름철 일사를 고려한 투명 투과체 공간의 열환경 특성에 관한 사례연구)

  • Ryu, Young-Hee;Seo, Hye-Soo;Lee, Min-Jung;Nam, Ji-yeon;Song, Mi-Na;Chun, Chung-Yoon
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, buildings with transparent glazing on exterior walls have increased. The transparent glazing on exterior walls gives an impression of opening through introducing external environment's elements to inside of the building, and has various merits and so on, but has defects in controling indoor environments. Especially, the excess of solar radiation in summer increases cooling load causing discomforts to occupants providing radiant environment with high temperature. Cooling load mainly depends on electricity comparing to heating load and intents to centralize specific time. So it is necessary to work out a countermeasure. In this study, showed P building with transparent glazing on exterior walls as a case, investigated indoor thermal performance, numerical analysis of P building in summer through comparing dry-sauna which is represented as radiant environment with high temperature. In the results of this study, transparent glazing space has radiant environment with high temperature such as dry-sauna because of the excess of solar radiation. Accordingly countermeasures are considered in building planning. As concrete methods, there are adiabatic effects using double glazing, use of sunscreen, blind, ventilation facilitation using natural draft, decrease of surface temperature through evaporation cooling and cooling coils.

Methods of Making Samples for a Visual Experiment with Feature Lines of Outer Automotive Panels (자동차 외판 특징선의 시각적 분석을 위한 시편 제작방법)

  • Han, Juho;Chung, Yunchan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.455-462
    • /
    • 2015
  • A feature line is a visually noticeable creased line on outer automotive panels. Feature lines play an important role in creating a good impression of a car. Even though the manufacturing quality of feature lines is important, it is difficult to achieve the designed shape owing to the springback of sheet metal. The current study presents five methods of making samples that will be used in a visual experiment to discover a quality control quantitative manufacturing allowance for feature lines. Measurement and inspection methods for the samples are also presented. The results show that plunge machining is the most accurate way to make the desired shape, and that wrapping the machined surface with sheet film is an appropriate way to emulate the roughness and visual texture of the painted outer panels of a car.

Bilateral Triamcinolone Induced Subconjunctival Granuloma in the Treatment of Scleritis Accompanied by Scleral Ectasia in a Dog

  • Kang, Seonmi;Go, Dumin;Kim, Daeyong;Seo, Kangmoon
    • Journal of Veterinary Clinics
    • /
    • v.35 no.4
    • /
    • pp.130-136
    • /
    • 2018
  • A 6-year-old spayed female American Cocker Spaniel presented with episcleritis in the right and then the left eye (OS) at eight month interval. Repeated intralesional triamcinolone acetonide was administered subconjunctivally to both eyes (OU). During this period, scleral ectasia was revealed on ocular funduscopy OS and then confirmed on ultrasonography and computed tomography. A year later, conjunctival hyperemia occurred around remnant triamcinolone particles and was treated by resection of these particles in the OU. A recurrence of episcleritis, which did not regress, required repeated triamcinolone subconjunctival injections four months later in the OU. Four months after these injections OU, the dog was presented with bilateral conjunctival mass, which had developed over the previous month. The round-shaped masses with diameters of 1 cm were surgically resected from exposed scleral ectasia lesion of thin and bulging scleral surface in the OU. The cross-section of both masses showed a white-colored accumulation at the center and triamcinolone induced granulomas enclosing necrotic tissue were confirmed by impression cytology and histopathological examination.

Connect Attachment of Fixed Segmented Bridge (고정성 분할 브릿지의 연결 어태치먼트)

  • Kim, Nam-Joong
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.127-138
    • /
    • 2002
  • There are some cases that dental prosthesis does not operate as properly as expected in oral mouth. The reasons are such as a distortion of the mandibular, a fault of impression taking system or an extrusion of remaining teeth. One of dental prostheses to consider in the situations is the attachment which connects segment bridge. Active discussions are managed on theoretical side of this field but few on clinical side of it, which must be considered first. Accordingly I'd like to suggest a theoretical background for connect attachment of fixed segmented bridge. 1. As a bridge gets longer, burden on dental ligament is increased and the hardness of a bridge is lessened. 2. The flexibility of a bridge increases in ratio to 3 multiplication of the length and decreases in ratio to 3 multiplication of the width of occlusal surface and base of pontic. 3. Precision rest is needed to cope with the shake of teeth and the difference of axis direction among abutments. 4. Female part of the precision rest should be on middle abutment distal and male one on mesial of pontic. 5. Segmented attachment can be efficiently used to cope with long span bridgework and also in case that one piece casting can't be done because of slant of abutment.

  • PDF

phenomenological representation of nature in Display (디스플레이에 있어서 자연과 현상)

  • 임진이
    • Korean Institute of Interior Design Journal
    • /
    • no.27
    • /
    • pp.145-151
    • /
    • 2001
  • There is so much difference in the way we perceive nature whether from eastern or western, present or past standpoint. however, awareness of coexistence between human beings and nature along with the concept that the most natural is th e most beautiful remain unchanged. The desire to describe the beauty of nature have existed all through the ages, but the (new) naturalism movement was spawned in our time when so much devastation and side effects took place for the expediency of nature, and field of display has been trying new interpretation of nature with direct or applied method. Naturalism trend is studied using the categories such as relationship between human and nature, space concept in western and eastern society, and the definition of view of nature in modern time. Elements of naturalism display are classified into the element of physical properties and element beyond the physical properties, and then methodology on naturalism display is investigated, using the illustration of display examples, in order to know the most essential elements of display, which are the physical properties such as space, light, object, glass, are expressed based on the elemental concept like nature, an accident, dynamic state, variability. As mentioned above, Naturalism display consists of physical properties and phenomenon. How to ive strong impression to a spectator depends on the ability to create effective space applying these elements. The significance of this study comes to surface in a time when the tremendous emphasis is put on the importance of nature and concerns about the role of display has become even greater.

  • PDF

Coronoid Process Hyperplasia: A Rare Case of Restricted Mouth Opening Masquerading as Temporomandibular Disorder

  • Juhyun Cha;Jin Woo Chung
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.3
    • /
    • pp.112-117
    • /
    • 2023
  • Coronoid process hyperplasia (CPH) of the mandible is a rare condition in which abnormal elongation of the coronoid process leads to chronic mandibular hypomobility. CPH causes impingement or impedance of the coronoid process on the inner surface of the frontal part of the zygomatic bone during mouth opening. The lack of significant symptoms makes the diagnosis difficult. Its etiology remains inconclusive despite several theories being suggested. In this report, three reviewed cases are presented. All three patients visited our clinic with limited mouth opening as the chief complaint. Standard clinical and radiographic examinations were conducted under the initial impression of temporomandibular disorders (TMDs), and restricted jaw movements were confirmed in all cases. The absence of improved signs and symptoms following conservative treatment for TMDs or the indeterminate plain radiographs required the attending clinicians to consider three-dimensional imagery. Computed tomography revealed bilateral coronoid hyperplasia in all cases and impingement on the zygomatic bone in two of the three cases. After concluding that this condition caused the patients' limited mouth opening, the patients were referred to the Department of Oral and Maxillofacial Surgery for possible bilateral coronoidectomy or coronoidotomy. CPH usually presents no symptoms apart from a progressive reduction of mouth opening over time. Diagnosis is often delayed, and patients may undergo unnecessary treatment procedures. Clinicians should be aware of this condition and exercise caution in the differential diagnosis of patients with chronic mandibular hypomobility.

Selection of all ceramic crown (완전 도재관의 선택)

  • Lee, Seung-Kyu
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.122-133
    • /
    • 2015
  • The requirements for the successful treatment of all-ceramic restorations are not so different from the ones of conventional restorations. "The provisional restoration followed by an adequate tooth reduction" and "the accurately fitting prostheses with corresponding to final impression" can be the examples of them. Nevertheless, the one which all-ceramic restorations are distinguished from conventional restorations is the additional procedure of so called "bonding". In addition to the application of resin cement between "inner surface of restoration and outer surface of abutment", bonding technology can be also applied to the treatment process of "Post and Core" in particular if the abutments are non-vital teeth. Core build-up for all-ceramic crown is conducted with fiber post and tooth colored composite by considering the properties of the restorations transmitting light. We know well that a vital abutment is easier than a non-vital one to get the targeted goals for clinical success in connection with esthetics and structure. The creation of "Post and Core" with bonding technique is a decisive factor for a long-term success if the abutment is non-vital tooth with dentinal collapse. I would like to share my clinical experience about "post & core build-up and all-ceramic restoration bonding" out of several success strategies of all-ceramic crown with this review article.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

A STUDY ON MORPHOLOGY AND SIZE OF CLINICAL CROWN OF PERMANENT MANDIBULAR MOLAR IN KOREAN ADULT (한국 성인의 하악대구치 임상치관의 형태와 크기에 관한 연구)

  • Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.242-255
    • /
    • 1999
  • The purpose of this study was to estimate the morphology and the size of permanent mandibular molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study The subjects were taken impression to make study model. On the study model, the 5 dentists measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. The clinical crown height, width, thickness and the other anatomical structures had symmetrical relationship between the left and right mandibular molar. 2. In the clinical crown height aspect, the buccal crown heights always were higher than the lingual crown height. The heights of the each surface, the buccal or lingual surface, were gradually decreased from the 1st molar to the 2nd molar and the difference on the buccal surface was higher than that on the lingual surface. 3. In the clinical crown width aspect, the mesiodistal measurement of the mandibular 1st molar was higher than that of the mandibular 2st molar. 4. In the clinical crown thickness aspect, the mesial buccolingual measurement was highest on the mandibular 1st molar and the distal buccolingual distance was lowest on the mandibular 2nd molar. This distal thickness of the mandibular molar always was higher than that of the mesial half. 5. The well-developed mesiobuccal groove of the 1st molar was observed more often than that of the 2nd molar. The buccal pit was also observed more frequently at the 1st molar, but the frequency(35%) was not high. 6. The occlusal type according to the number of cusp was almost 5-cusp(98%) in the 1st molar and was also 5-cusp(63%) in the 2nd molar. The frequency of the 6th cusp was 31% in the 1st molar and was 22% in the 2nd molar. The frequency of the 7th cusp was below 2of in the both teeth. 7. In the buccolingual intercuspal distance aspect of the mesial and distal half, the intercuspal distance of distal half was higher than that of the mesial half on the 1st and 2nd molar, but the difference on the 1st molar was higher than that on the 2nd molar. 8. The difference between the widths of the buccal and lingual half was 1.5mm in the 1st molar and 0.8mm in the 2nd molar. Therefore the lingual convergency of the occlusal surface was more higher in the 1st molar. 9. On the mandibular 1st and 2nd molar, the distobuccal external angle was more acute than the mesiobuccal external angle. But the mesiobuccal internal angle was more acute than the distobuccal internal angle. 10. When the mandibular molar was a 5-cusp type, the development of the distal cusp on the 1st molar was better than that on the 2nd molar. The difference between the cusps was around 0.4mm.

  • PDF

Neutral zone approach and external impression for rehabilitation of macroglossia: a case report (거대설을 가진 환자에서 중립대 개념과 연마면 인상을 이용한 총의치 수복 증례)

  • Kang, Hyeon;Seo, Nu-Ri;Park, Sang-Won;Yun, Kwi-Dug;Park, Chan;Lim, Hyun-Pil
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.218-224
    • /
    • 2018
  • Macroglossia is an obstacle in regard to general prosthodontic restoration. Not only is it difficult to obtain support and stability from dentures manufactured from normal protocol, obtaining efficacy from basic mastication is also difficult. In such cases, realizing harmony between the occlusion and surrounding muscle structures may be important with regard to manufacture of stable full dentures, and it is necessary to form the appropriate polished surface for this case. The neutral zone is defined as the potential area resulting from the neuromuscular function that results in equilibrium between the outward force exerted by the tongue and the inward force exerted by the lips and cheeks. The artificial teeth of the full denture lies in this area, and if the polished zone follows the anatomic form of the dynamic muscles, the movement of the muscles simply acts as an element of stabilizing the dentures improving the esthetics through facial support.