• Title/Summary/Keyword: Impression Technique

Search Result 178, Processing Time 0.027 seconds

THE EFFECT OF SPRUE DESIGN ON THE MARGINAL REPRODUCIBILITY OF CAST TITANIUM CROWNS (주입선 형태가 티타늄 주조관의 변연재현성에 미치는 영향)

  • Park Jae-Kyoung;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.352-364
    • /
    • 2002
  • There has been a great interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However the high melting temperature and chemical reactivity of titanium necessitates casting systems different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new developments in Ti casting systems, inadequate mold filling and internal porosity are frequently observed casting defects. Therefore, the study on the fabrication technique including sprue design to solve these casting defects is still necessary. In this study to evaluate the effect of sprue design on the castability of simulated cast titanium crowns, 10 cylindrical cast crowns for each group with four different sprue design(Single group. Double group, Runner bar group. Reservoir group) were fabricated. An impression of the entire casting margin was made and cut at $90^{\circ}$ intervals, and the sections were photographed in a microscope at $100{\times}$ magnification to record marginal discrepancy. The internal porosities of the cast crowns were disclosed by radiographs. Within the limits of this study. the following conclusions were drawn. 1. The overall mean marginal discrepancies for each group were as follows: Double group, $43.65{\mu}m$; Reservoir group, $50.27{\mu}m$; Single group, $54.17{\mu}m$; Runner bar group, $58.90{\mu}m$ (p<0.05). 2. The mean of marginal discrepancies for wax patterns was $10.65{\mu}m$. 3 The numbers of internal porosity showed the most in Runner bar group followed by Single group, Reservoir group, and Double group.

Effect of two-phase fabrication method for the optimum fit of light-polymerized record bases

  • Huh, Jung-Bo;Kang, Min-Goo;Shin, Sang-Wan;Ryu, Jae-Jun
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.102-105
    • /
    • 2010
  • PURPOSE. The aims of this study were to suggest a method of fabrication of the record base using a light-polymerized resin by applying the two-phase fabrication method for the improvement of the fit of the record base and to compare the degree of fit according to the separation site. MATERIALS AND METHODS. In the edentulous cast of maxilla, four test groups were considered. In the first, second, third, and fourth test groups (n = 12 in each group) the separation was done at 0, 5, 10, and 15 mm, respectively below the alveolar crest along the palatal plane. For the control group, the record base was made without separating the two sections. The light-body silicone material was injected into the fitting surface of the record base. It was then placed onto the cast and finger pressure was applied to stabilize it in a seated position followed by immediate placement onto the universal test device. Finally, the mass of the impression material was measured after it was removed. ANOVA was performed using the SAS program. For the post-hoc test, the Wilcoxon Rank-Sum test and the Tukey-Kramer HSD test were performed ($\alpha$ = 0.05). RESULTS. The control group and Group 3, 4 showed significant differences. The Group 3 and 4 showed significantly smaller inside gaps than the control group which was not made with the two-phase fabrication method. CONCLUSION. The two-stage polymerized technique can improve the fit of the denture base particularly when the separation was made at 10 to 15 mm from the alveolar crest.

Fabrication of complete dentures for a patient with odontogenic myxoma: A case report (치성 점액종 환자의 총의치 수복증례)

  • Jeong, Da-Woon;Kim, Hyun-Hee;Bae, Jung-Yoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.64-69
    • /
    • 2018
  • Odontogenic myxoma of the jaws is a rare benign odontogenic tumor. In this case, a 61-year-old male patient had a chief complaint about maxillary anterior gingival mass and excisional biopsy result confirmed odontogenic myxoma. The clear acrylic resin custom tray was designed to minimize displacement of flabby tissue which remained after the surgery. Neutral zone and external impression technique could provide satisfactory result in terms of denture stability and retention during jaw relation record and wax denture try-in procedure. This clinical report describes fabrication of complete dentures for a patient with odontogenic myxoma in regard to flabby tissue and neutral zone.

Evaluation of suitability and stability in a skeletal Class III complete denture patient with flabby tissue: A case report (Flabby tissue를 동반하는 골격성 Class III 환자의 양악 총의치 수복 및 적합성/안정성 평가 증례)

  • Lee, Junsuk;Hong, Seoungjin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • To obtain denture retention, support, and stability in Class III edentulous cases with flat alveolar ridges and extensive flabby tissue is very difficult. The patient was a 72-year-old male who wore ill-fitting 20 year old dentures made by non-medical institutions. There was flabby tissue on the maxillary anterior ridge. The patient showed Angle Class III skeletal relationship with severe protruded mandible. First, temporary dentures were fabricated to restore the masticatory function, and final dentures were made through non- pressure impression technique and careful the arrangement of the posterior resin teeth. Improvement of the retention and stability of the denture during the occlusal force application is reported.

Small Incision and Dual-Top Screws for Treatment of Simple Depressed Anterior Frontal Sinus Fractures (소절개 및 Dual-top screw를 이용한 전두동 전벽 단순 함몰골절의 치료)

  • Moon, Suk Ho;Oh, Deuk Young;Seo, Byung Chul;Rhie, Jong Won;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.345-348
    • /
    • 2008
  • Purpose: Fracture of the frontal sinus accounts for 5-15% of all facial fractures. Only anterior table fracture occupies one third of the frontal sinus fracture. Conventional coronal approach is the standard treatment, but this method is very aggressive, especially in patient with simple, depressed, anterior frontal sinus wall fracture. We introduce new, simple technique for these patients, using small incision and Dual-top screws. Methods: A 27-year-old male patient was introduced to our department under the impression of fracture of frontal sinus, involving only anterior table. Under general anesthesia, 1.5 cm-sized, small incision was made on the suprabrow area. We reduced fractured fragment with two dual-top screws and 25G wires. Fixation was not necessary Results: The operation took about forty minutes, and the patient discharged 2 days after the operation. Postoperative 2 months follow up CT shows maintenance of reduction site. Gross depression of the forehead and visible scar was not observed. Conclusion: Although the indication of this procedure is limited, less aggressive, simple and very effective to the patient with simple. depressed, anterior frontal sinus fracture.

Analysis of Satisfaction Surveys in Accordance with the Characteristics of the Components of Trick Art Experience Exhibition Space During -Around Seoul Trick Art Exhibition of Three Cases- (트릭아트 체험전시공간의 구성요소별 특성에 따른 만족도조사 분석 - 서울지역의 트릭아트전시관 3개 사례를 중심으로 -)

  • Lee, Dong-Hee;Han, Hae-Ryon
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.5
    • /
    • pp.139-145
    • /
    • 2014
  • As life is changing, modern people are interested in culture life more than the past and as a result Art Exhibition increases. Nowadays many methods of exhibit are introduced, especially Direct experience. Trick Art Experience exhibition introduced Direct experirence to a work of art for interests and used props, objets, images, and sounds for maximizing experience element. Trick Art Experience exhibition added humor as imitating famous painting and gave a deep impression through the optical illusion technique which make flat structure look three-dimensional structure. Recently, demands for Experience exhibition which are like Trick Art increase. This study figure out pros and cons through a comparison analysis of direction and component about Trick Art Experience exhibition and find a check list about making an audience active about experience. From now on, we have an object about showing design data including customer satisfaction measurement to make various expressions of direction and component about Experience Art through a case analysis. We have firsthand visited case spaces to experience the spaces and prepared a check list for the relevant types of expressions. Referring to the exhibit work classification system, components that correspond to Trick Art Experience exhibition were grouped according to constituting items. Among the types of expressions, the levels of satisfaction with Experience exhibition and Participating exhibit were found to be high and the level of satisfaction with Heart Moving exhibit was found to be low through surveys. Among the components, the levels of satisfaction with stereograms and formative effect elements were found to be high and those of spatial changes and media effects were found to be low through surveys. Therefore, the expressions should be reinforced and the components should be improved.

Suggestions on the Concept and Usage of Effects Needed for Vocal Recording -With focus on reverb- (보컬 녹음에 필요한 이펙트의 개념과 사용법에 관한 제언 - Reverb를 중심으로 -)

  • Cho, Tae-Seon;Choi, Won-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.380-386
    • /
    • 2018
  • One of the most difficult technical aspects of music is vocals (the voice). Unlike ordinary musical instruments, it is difficult to apply common values because the tone (that is, the color) varies greatly depending on the singer, and therefore, it is necessary to properly mix in various effects. Therefore, this study is intended to suggest concepts, the current state, and effective usage of reverberation (or reverb), which is the most typical of vocal effects, using wave renaissance reverb, which is one of the effects that are the most commonly used by students. The most important part of the mixing process in popular music is how to enhance the voice. Since the spatial impression of sound makes music more beautiful, the role of reverb as a vocal effect is absolute. Computer technology has made it easier to create music, but it has produced a side effect in which individual technique falls short, such as using predetermined presets only. Studies on the use of reverb by musicians through more detailed efforts are expected to contribute to creating good music.

Correction of the hardness measurement for pile-up materials with a nano indentation machine (파일-업 재료에 대한 나노 압입 시험기의 경도 측정값 교정)

  • Park, Moon Shik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.98-106
    • /
    • 2016
  • Measurements of the elastic modulus and hardness using a nano indentation machine rely on the equation for the fitted contact area, which is valid for only sink-in materials. For most soft engineering materials that involve pile-up behavior rather than sink-in, the contact area equation underestimates the contact area and thus overestimates the elastic modulus and hardness. This study proposes a correction method to amend erroneous hardness measurements in pile-up situations. The method is a supplemental derivation to the original hardness measurement with the known value of the elastic modulus. The method was examined for soft engineering metals, Al 6061 T6 and C 12200, via tensile tests, nano indentation tests, impression observations, and finite element analysis. The proposed technique shows reasonable agreement with the analytical results accounting for strain gradient plasticity from a previous study.

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES OF COMPLETE DENTURE OCCLUSION (하악 총의치 교합형태에 따른 하부조직에 미치는 교합력 양태의 3차원적 유합요소법 해석)

  • Lee Young-Soo;Yoo Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.286-318
    • /
    • 1992
  • The objective of preventive dentistry is the maintenance of a healthy dentition for the life of a patient. Unfortunately, if an individual has not received the benefit of a comprehensive program of preventive dentistry and has finally reached the edentulous state, as a consequence, he receives a set of complete denture. Dentures are mechanical devices and subject to the principles of mechanics. In some cases, the general health and nutritional status of the patient are felt to be the causative factors. But, the most important thing in residual ridge resorption is felt to be caused by the unequal distribution of functional forces. This study was to analyze mandibular stresses of complete denture occlusion by three dimensional finite element method. The results were as follows ; 1. As deformation and stress distribution of the complete denture of the mandible were concentrated on the upper lingual side of the mandible, alveolar ridge resorption of the mandible occurred from lingual side to labio-buccal side. 2. Analyzing by three dimensional F. E. M., the mandible is a very effective form for tolerating stress and deformation biomechanically. 3. According to the concentration of stress distibution in the upper buccal side of the lower posteriors, buccal shelf area must be a primary stress bearing area in the lower complete denture. 4. Lower complete denture moved horizontally to the balancing side under lateral occlusal force. 5. Bilateral balanced occlusion should be constructed in the complete denture for denture stability, especially in the protrusive movement. 6. Physical property of the denture base material was as important for stress distribution in the denture base as or even more than that in the mandible. 7. Impression technique is very important because of most of stress was concentrated between them due to close contact of the mandible and the denture base.

  • PDF

3D Simulation of Dental Implant Surgery Using Surgical Guide Stents (식립 보조도구를 이용한 3D 치아 임플란트 시술 시뮬레이션)

  • Park, Hyung-Wook;Kim, Myong-Soo;Park, Hyung-Jun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.3
    • /
    • pp.216-226
    • /
    • 2011
  • Surgeon dentists usually rely on their experiential judgments from patients' oral plaster casts and medical images to determine the positional and directional information of implant fixtures and to perform drilling tasks during dental implant surgical operations. This approach, however, may cause some errors and deteriorate the quality of dental implants. Computer-aided methods have been introduced as supportive tools to alleviate the shortcomings of the conventional approach. In this paper, we present an approach of 3D dental implant simulation which can provide the realistic and immersive experience of dental implant information. The dental implant information is primarily composed of several kinds of 3D mesh models obtained as follows. Firstly, we construct 3D mesh models of jawbones, teeth and nerve curves from the patient's dental images using software $Mimics^{TM}$. Secondly, we construct 3D mesh models of gingival regions from the patient's oral impression using a reverse engineering technique. Thirdly, we select suitable types of implant fixtures from fixture database and determine the positions and directions of the fixtures by using the 3D mesh models and the dental images with software $Simplant^{TM}$. Fourthly, from the geometric and/or directional information of the jawbones, the gingival regions, the teeth and the fixtures, we construct the 3D models of surgical guide stents which are crucial to perform the drilling operations with ease and accuracy. In the application phase, the dental implant information is combined with the tangible interface device to accomplish 3D dental implant simulation. The user can see and touch the 3D models related with dental implant surgery. Furthermore, the user can experience drilling paths to make holes where fixtures are implanted. A preliminary user study shows that the presented approach can be used to provide dental students with good educational contents. With future work, we expect that it can be utilized for clinical studies of dental implant surgery.