• Title/Summary/Keyword: Implantation window

Search Result 26, Processing Time 0.2 seconds

Surgical Treatment of Anomalous Connection of Left Coronary Artery to the Pulmonary Artery [ALCAPA] (주관상동맥-폐동맥 이상연결증의 외과적 수술요법)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.228-233
    • /
    • 1993
  • Patients with anomalous connection of the left coronary artery to the pulmonary artery are at risk for myocardial infarction, and early or sudden death. Between 1986 to 1992, a total of 4 of these patients underwent surgical intervention with various operative techniques at our institution. Age at operation ranged from 2 months to 43 years. Three infant patients had congestive heart failure, 2 of them had mitral regurgitaion, and 1 had ST-T change on elctrocardiogram. Operative techniques included direct coronary artery transfer to the aorta[n=2], intrapulmonary tunnel from the aortopulmonary window[n=1], coronary artery bypass using saphenous vein[n=1]. One deaths occured at 2 weeks after direct coronary arterial transfer due to respiratory failure caused by Respiratory Syncitial virus pneumonia. Supravalvar pulmoanry stenosis occured after intrapulmoanry tunnel. We recommend direct aortic implatation of the anomalous coronary artery at the time of diagnosis. Intrapulmonary tunnel from aortopulmonary window or subclavian-coronary anastomosis could be alternatives in whom aortic implantation is not feasible anatomically.

  • PDF

CLINICAL EVALUATION OF DELAYED VERSUS SIMULTANEOUS IMPLANTATION WITH SINUS LIFTING (상악동거상술시 임프란트의 지연식립과 즉시식립에 대한 임상적 연구)

  • Suh, Dong-Won;Lee, Dong-Keun;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.442-450
    • /
    • 2009
  • Purpose: Simultaneous implantation has been traditionally limited to patients with at least 5 mm of residual bone to ensure that the implant is completely stabilized. This is considered to be one of the most critical factors for primary implant stability and parallelism and, subsequently osseointegration. Recently, improved initial implant stability is provided by advancement of surgical techniques, implant designs and surface treatments. This has led surgeons to extending simultaneous treatment option to patients with below 4 mm of residual bone height, despite the lack of much data. The purpose of this study was to retrospectively evaluate and compare the status of implants which are installed by delayed and simultaneous methods. Material and methods: The subjects were patients(121 patients, 278 implants) who had been operated with sinus lifting from 2003 to 2007 in Sun Dental Hospital. Lateral window approach with autograft and xenograft(1:1 ratio) were carried out for all sinus lifting. 4 types of implant were used. The mean follow up period was 26.3 months(19 - 58 months) in delayed group, and 22.8 months(18 - 43 months) in simultaneous group. Results: The survival rate of implant restoration of this study was 98.2% in delayed group and 91.7% in simultaneous group. In simultaneous group, wide-platform type implants showed 100% survival rate. The total average of marginal bone loss in radiographs was $0.96\;{\pm}\;0.29\;mm$ in delayed group and $1.02\;{\pm}\;0.31\;mm$ in simultaneous group. Conclusion: Simultaneous implantation with sinus lifting(below 4mm of residual bone height) could be predictable treatment.

Determination of optimal ion implantation conditions to prevent double snapback of high voltage operating DDDNMOS device for ESD protection (고전압 정전기 보호용 DDDNMOS 소자의 더블 스냅백 방지를 위한 최적의 이온주입 조건 결정)

  • Seo, Yong-Jin
    • Journal of IKEEE
    • /
    • v.26 no.3
    • /
    • pp.333-340
    • /
    • 2022
  • Process and device simulations were performed to determine the optimal ion implantation conditions to prevent double snapback of high voltage operating DDDNMOS (double diffused drain N-type MOSFET) device for ESD protection. By examining the effects of HP-Well, N- drift and N+ drain ion implantation on the double snapback and avalanche breakdown voltages, it was possible to prevent double snapback and improve the electrostatic protection performance. If the ion implantation concentration of the N- drift region rather than the HP-Well region is optimally designed, it prevents the transition from the primary on-state to the secondary on-state, so that relatively good ESD protection performance can be obtained. Since the concentration of the N- drift region affects the leakage current and the avalanche breakdown voltage, in the case of a process technology with an operating voltage greater than 30V, a new structure such as DPS or colligation of optimal process conditions can be applied. In this case, improved ESD protection performance can be realized.

Clinical Comparative Study for Maxillary Sinus Augmentation Using Deproteinized Bovine Bone Mineral and Mineralized Allograft (탈단백우골과 비탈회 동종골을 사용한 상악동 거상술의 임상적 연구)

  • Jo, Ji-Ho;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.442-446
    • /
    • 2010
  • Purpose: The purpose of this study was to compare the clinical efficacy of popular bone graft materials mineralized allograft and deproteinized bovine bone mineral. Materials and Methods: One hundred seven implants of 78 patients, accompanied by sinus lift using the lateral window technique and simultaneous implantation, were sampled. In addition, some patients with severe systemic conditions were excluded. The initial bone heights of all patients ranged from 3-6 mm. All of the sample cases were treated at our hospital from January 2005 to January 2008. Techniques other than the lateral window technique were excluded, and only one graft material ($Tutoplast^{(R)}$ or Bio-$Oss^{(R)}$) was accepted for inclusion. $Tutoplast^{(R)}$ was used in 63 implants of 41 patients, whereas Bio-$Oss^{(R)}$) was chosen for the remaining 44 implants of 37 patients. The diameters of the particles used ranged from 0.25-1.0 mm, and the volume was 0.5-2 cc (mean, 1.5 cc). Results: The survival rate of the implant fixtures was 99.07% when the lateral window technique was used. Among all of the cases, cases in which $Tutoplast^{(R)}$ was used demonstrated a survival rate of 98.4%, whereas Bio-$Oss^{(R)}$) resulted in 100% survival. With respect to the alveolar bone height, no significant differences were detected between the two graft materials that failed. Conclusion: According to the result reported above, the two common materials for sinus augmentation do not have clinically significant difference. Rather, host factors, such as the height of residual bone, which could be disclosed during questioning patients' systemic conditions, might have greater effects on the prognosis.

A Study on Frequency Characteristics According to the Output Transmission Method of Round Window Driving Middle Ear Implants (정원창 구동형 인공중이의 출력 전달 방식에 따른 주파수 특성 연구)

  • Seong, KiWoong;Shin, DongHo;Na, SungDae;Lee, JyungHyun;Kim, MyoungNam;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.183-187
    • /
    • 2018
  • In this paper, we investigated the efficiency according to the output transmission method of the round window driving type AMEIs (active middle ear implants) through the cadaveric experiment. For the experiment, we fabricated DRT (direct rod transducer) and FMT (floating mass transducer) type vibrational transducers based on our previous studies and conducted their output characteristics were measured. TCBT (tri-coil bellows transducer) and DFMT (differential floating mass transducer) were implemented with the same driving force and electrical characteristics as one of DRT and FMT, respectively. In the experiment using three human temporal bone, normal stapes vibration was measured with 1 Pa in front of tympanic membrane, and then was compared with each output of transducers. From the comparison, the DRT type vibration transducer was superior in overall energy transfer efficiency, especially in the low frequency range. There was no difference in implantation difficulty between the two transducers. The results of this study suggest that the DRT type vibrational transducer is more efficient and needs further study to overcome the low frequency degradation in round window approaching with FMT.

The Role of the Endometrium and Embryo in Human Implantation (인간 착상 과정에 자궁내막과 배아의 역할)

  • Jee, Byung-Chul
    • Development and Reproduction
    • /
    • v.13 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Implantation itself is governed by an array of endocrine, paracrine and autocrine modulators, of embryonic and maternal origin. Window of implantation is the unique temporal and spatial expression of factors allows the embryo to implant via signaling, appositioning, attachment, and invasion in a specific time frame of $2{\sim}4$ days. When the embryo has arrived in the uterine cavity, a preprogrammed sequence of events occurs, which involves the production and secretion of a multitude of biochemical factors such as cytokines, growth factors, and adhesion molecules by the endometrium and the embryo, thus leading to the formation of a receptive endometrium. Cytokines such as LIF, CSF-1, and IL-1 have all been shown to play important roles in the cascade of events that leads to implantation. Integrin, L-selectin ligands, glycodelin, mucin-1, HB-EGF and pinopodes are involved in appositioning and attachment. The embryo also produces cytokines and growth factors (ILs, VEGF) and receptors for endometrial signals such as LIF, CSF-1, IGF and HB-EGF. The immune system and angiogenesis play an important role. The usefulness of these factors to assess endometrial receptivity and to estimate the prognosis for pregnancy in natural and artificial cycles remains to be proven. Integrins, pinopodes, glycodelin and LIF (from biopsies) are promising candidates; from uterine flushings, glycodelin and LIF are also candidates. The ideal serum marker is not available, but VEGF, glycodelin and CSF have some clinical implications. Further evaluation that includes larger groups of infertile women and fertile controls are needed to elucidate whether their presence in plasma, flushing fluid, or endometrial samples can be used as some kind of a screening tool to assess endometrial function and prognosis for pregnancy before and after artificial reproductive therapy. A better understanding of their function in human implantation may lead to therapeutic intervention, thereby improving the success rate in reproduction treatment. New molecular techniques are becoming available for measuring both embryonic and endometrial changes prior to and during implantation. The use of predictive sets of markers may prove to be more reliable than a single marker. Ultimately, the aim is to use these tools to increase implantation in artificial cycles and consequently improve live-birth rates.

  • PDF

One-stage Repair of Distal Aortopulmonary Septal Defect, Aortic Origin of Right Pulmonary Artery, Patent Ductus Arteriosus and Hypoplasia of Aortic Isthmus -A case of report- (대동맥 협부 발육부전, 동맥관 개존, 대동맥기시 우폐동맥을 동반한 원위 대동맥폐 동맥 중격결손의 일차 완전 교정술 1례)

  • 이호철;류한영
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.554-558
    • /
    • 1996
  • A case of distal aortopulmonary septal defect associated with aortic origin of right pulmonary ar- tery, patent ductus arteriosus and hypoplasia of aortic isthmus in a 50-day-old female infant is presented. Ligation of patent ductus arteriosus, resection and end-to-end anastomosis of hypoplasia of aortic isthmus, implantation of rlght pulmonary artery to main pulmonary artery and autologous peri- cardial patch repair of aortopulmonary septal defect were performed under cardiopulmonary bypass as one-stage approach. Deep hypothermic total circulatory arrest was applied during repair of hypoplasia of aortic isthmus. The p stoperative course was uneventful.

  • PDF

Usefulness of Silicone Plate for Sellar Floor Reconstruction (터어키안 저부 재건술시 실리콘 판의 유용성)

  • Kim, Sung Bum;Kim, Jae Min;Yi, Hyeong Joong;Bak, Koang Hum;Kim, Choong Hyun;Oh, Suck Jun;Lee, Seoung Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1204-1208
    • /
    • 2000
  • Objectives : At the closure of the transsphenoidal approach(TSA), the proper sellar floor reconstruction plays an important role in preventing postoperative complications. The septal cartilage, perpendicular plate of nasal septum, and the sphenoid sinus bone are usually used to repair the sellar floor as a bone splint. The authors evaluate the usefulness of a silicone plate as a substitute for bone splint to close a defect of the sellar floor. Materials and Methods : A silicone plate was used to repair the sellar floor in 7 patients with sellar lesions which included four pituitary adenomas, two Rathke's cleft cysts and one metastatic tumor. Among seven cases, five cases underwent a standard TSAs and two received a extended TSAs. The trajectories of the approach were sublabial in four cases and endonasal routes in three cases. The silicone plate for implantation was cut to a size of slightly larger than that of bone window and inserted with a three-pronged fork, and then adjusted precisely. Results : In six patients, there were no complications which related to sellar floor reconstruction. A postoperative cerebrospinal fluid(CSF) rhinorrhea was observed in one patient with pituitary macroadenoma. Conclusions : From the authors' experience, the advantages of the silicone plate are its simplicity of molding to fit any size of sellar floor defects, and easy detection of previously created bone window at reoperation.

  • PDF