• Title/Summary/Keyword: Implantable

Search Result 316, Processing Time 0.023 seconds

ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements (일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로)

  • Sang Min, Park;Gyu Ha, Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

Manufacturing and in vitro Characterization of Composite Drug Delivery System (DDS) (복합재 약물전달 시스템의 제작 및 체외 환경 특성 평가)

  • Chu, Won-Shik;Jeong, Suk-Yong;Park, Jeong-Bin;Ahn, Sung-Hoon;Lee, Jae-Hoon;Chi, Sang-Chul
    • Composites Research
    • /
    • v.21 no.3
    • /
    • pp.18-23
    • /
    • 2008
  • The Rapid Prototyping (RP) technology has advanced in many application areas. In this research, implantable Drug Delivery System (DDS) was fabricated by an RP system, Nano Composite Deposition System (NCDS). The DDS composite consists of 5-fluorouracil (5-FU), as drug particles, and PLGA85/15 as biodegradable polymer matrix. To have larger surface area, the DDS was fabricated in a scaffold shape, and its degradation was tested in vitro environment. Biocompatible Hydroxyapatite (HA) powders were added to the drug-polymer composite in order to control drug release. Test results showed a possibility of controlled release of scaffold DDS over 50 days.

Bilateral Cardiac Sympathetic Denervation as a Safe Therapeutic Option for Ventricular Arrhythmias

  • Soo Jung Park;Deok Heon Lee;Youngok Lee;Hanna Jung;Yongkeun Cho
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.414-419
    • /
    • 2023
  • Background: The recurrence of ventricular arrhythmias (VAs) in patients who have already undergone treatment with antiarrhythmic medication, catheter ablation, and the insertion of implantable cardioverter defibrillators is not uncommon. Recent studies have shown that bilateral cardiac sympathetic denervation (BCSD) effectively treats VAs. However, only a limited number of studies have confirmed the safety of BCSD as a viable therapeutic option for VAs. Methods: This single-center study included 10 patients, who had a median age of 54 years (interquartile range [IQR], 45-65 years) and a median ejection fraction of 58.5% (IQR, 56.2%-60.8%), with VAs who underwent video-assisted BCSD. BCSD was executed as a single-stage surgery for 8 patients, while the remaining 2 patients initially underwent left cardiac sympathetic denervation followed by right cardiac sympathetic denervation. We evaluated postoperative complications, the duration of hospital stays, and VA-related symptoms before and after surgery. Results: The median hospital stay after surgery was 2 days (IQR, 2-3 days). The median surgical time for BCSD was 113 minutes (IQR, 104-126 minutes). No significant complications occurred during hospitalization or after discharge. During the median follow-up period of 13.5 months (IQR, 10.5-28.0 months) from surgery, no VA-related symptoms were observed in 70% of patients. Conclusion: The benefits of a short postoperative hospitalization and negligible complications make BCSD a safe, alternative therapeutic option for patients suffering from refractory VAs.

Surgical Outcomes of Centrifugal Continuous-Flow Implantable Left Ventricular Assist Devices: Heartmate 3 versus Heartware Ventricular Assist Device

  • Kinam Shin;Won Chul Cho;Nara Shin;Hong Rae Kim;Min-Seok Kim;Cheol Hyun Chung;Sung-Ho Jung
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.184-194
    • /
    • 2024
  • Background: Left ventricular assist devices (LVADs) are widely employed as a therapeutic option for end-stage heart failure. We evaluated the outcomes associated with centrifugal-flow LVAD implantation, comparing 2 device models: the Heartmate 3 (HM3) and the Heartware Ventricular Assist Device (HVAD). Methods: Data were collected from patients who underwent LVAD implantation between June 1, 2015 and December 31, 2022. We analyzed overall survival, first rehospitalization, and early, late, and LVAD-related complications. Results: In total, 74 patients underwent LVAD implantation, with 42 receiving the HM3 and 32 the HVAD. A mild Interagency Registry for Mechanically Assisted Circulatory Support score was more common among HM3 than HVAD recipients (p=0.006), and patients receiving the HM3 exhibited lower rates of preoperative ventilator use (p=0.010) and extracorporeal membrane oxygenation (p=0.039). The overall early mortality rate was 5.4% (4 of 74 patients), with no significant difference between groups. Regarding early right ventricular (RV) failure, HM3 implantation was associated with a lower rate (13 of 42 [31.0%]) than HVAD implantation (18 of 32 [56.2%], p=0.051). The median rehospitalization-free period was longer for HM3 recipients (16.9 months) than HVAD recipients (5.3 months, p=0.013). Furthermore, HM3 recipients displayed a lower incidence of late hemorrhagic stroke (p=0.016). In the multivariable analysis, preoperative use of continuous renal replacement therapy (odds ratio, 22.31; p=0.002) was the only significant predictor of postoperative RV failure. Conclusion: The LVAD models (HM3 and HVAD) demonstrated comparable overall survival rates. However, the HM3 was associated with a lower risk of late hemorrhagic stroke.

Clinical Safety and Efficiency of the H-Port for Treatment of Leptomeningeal Metastasis

  • Sung-Min Jang;Ho-Shin Gwak;Ji-Woong Kwon;Sang Hoon Shin;Heon Yoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.4
    • /
    • pp.467-476
    • /
    • 2024
  • Objective : To evaluate the usefulness of a cranial implantable chemoport, the H-port, as an alternative to the Ommaya reservoir for intraventricular chemotherapy/cerebrospinal fluid (CSF) access in patients with leptomeningeal metastasis (LM). Methods : One hundred fifty-two consecutive patients with a diagnosis of LM and who underwent H-port installation between 2015 and 2021 were evaluated. Adverse events associated with installation and intraventricular chemotherapy, and the rate of increased intracranial pressure (ICP) control via the port were evaluated for safety and efficacy. These indices were compared with published data of Ommaya (n=89), from our institution. Results : Time-to-install and installation-related complications of intracranial hemorrhage (n=2) and catheter malposition (n=5) were not significantly different between the two groups. Intraventricular chemotherapy-related complications of CSF leakage occurred more frequently in the Ommaya than in the H-port group (13/89 vs. 3/152, respectively, p<0.001). Intracranial hemorrhage during chemotherapy occurred only in the Ommaya group (n=4). The CSF infection rate was not statistically different between groups (14/152 vs. 12/89, respectively). The ICP control rate according to reservoir type revealed a significantly higher ICP control rate with the H-port (40/67), compared with the Ommaya result (12/58, p<0.001). Analyzing the ICP control rate based on the CSF drainage method, continuous extraventricular drainage (implemented only with the H-port), found a significantly higher ICP control rate than with intermittent CSF drainage (33/40 vs. 6/56, respectively, p<0.0001). Conclusion : The H-port for intraventricular chemotherapy in patients with LM was superior for ICP control; it had equal or lower complication rates than the Ommaya reservoir.

Left Atrial Strain Derived From Cardiac Magnetic Resonance Imaging Can Predict Outcomes of Patients With Acute Myocarditis

  • Jimin Lee;Ki Seok Choo;Yeon Joo Jeong;Geewon Lee;Minhee Hwang;Maria Roselle Abraham;Ji Won Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.512-521
    • /
    • 2023
  • Objective: There is increasing recognition that left atrial (LA) strain can be a prognostic marker of various cardiac diseases. However, its prognostic value in acute myocarditis remains unclear. Therefore, this study aimed to evaluate whether cardiovascular magnetic resonance (CMR)-derived parameters of LA strain can predict outcomes in patients with acute myocarditis. Materials and Methods: We retrospectively analyzed the data of 47 consecutive patients (44.2 ± 18.3 years; 29 males) with acute myocarditis who underwent CMR in 13.5 ± 9.7 days (range, 0-31 days) of symptom onset. Various parameters, including feature-tracked CMR-derived LA strain, were measured using CMR. The composite endpoints included cardiac death, heart transplantation, implantable cardioverter-defibrillator or pacemaker implantation, rehospitalization following a cardiac event, atrial fibrillation, or embolic stroke. The Cox regression analysis was performed to identify associations between the variables derived from CMR and the composite endpoints. Results: After a median follow-up of 37 months, 20 of the 47 (42.6%) patients experienced the composite events. In the multivariable Cox regression analysis, LA reservoir and conduit strains were independent predictors of the composite endpoints, with an adjusted hazard ratio per 1% increase of 0.90 (95% confidence interval [CI], 0.84-0.96; P = 0.002) and 0.91 (95% CI, 0.84-0.98; P = 0.013), respectively. Conclusion: LA reservoir and conduit strains derived from CMR are independent predictors of adverse clinical outcomes in patients with acute myocarditis.

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

Neurotechnologies and civil law issues (뇌신경과학 연구 및 기술에 대한 민사법적 대응)

  • SooJeong Kim
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.2
    • /
    • pp.147-196
    • /
    • 2023
  • Advances in brain science have made it possible to stimulate the brain to treat brain disorder or to connect directly between the neuron activity and an external devices. Non-invasive neurotechnologies already exist, but invasive neurotechnologies can provide more precise stimulation or measure brainwaves more precisely. Nowadays deep brain stimulation (DBS) is recognized as an accepted treatment for Parkinson's disease and essential tremor. In addition DBS has shown a certain positive effect in patients with Alzheimer's disease and depression. Brain-computer interfaces (BCI) are in the clinical stage but help patients in vegetative state can communicate or support rehabilitation for nerve-damaged people. The issue is that the people who need these invasive neurotechnologies are those whose capacity to consent is impaired or who are unable to communicate due to disease or nerve damage, while DBS and BCI operations are highly invasive and require informed consent of patients. Especially in areas where neurotechnology is still in clinical trials, the risks are greater and the benefits are uncertain, so more explanation should be provided to let patients make an informed decision. If the patient is under guardianship, the guardian is able to substitute for the patient's consent, if necessary with the authorization of court. If the patient is not under guardianship and the patient's capacity to consent is impaired or he is unable to express the consent, korean healthcare institution tend to rely on the patient's near relative guardian(de facto guardian) to give consent. But the concept of a de facto guardian is not provided by our civil law system. In the long run, it would be more appropriate to provide that a patient's spouse or next of kin may be authorized to give consent for the patient, if he or she is neither under guardianship nor appointed enduring power of attorney. If the patient was not properly informed of the risks involved in the neurosurgery, he or she may be entitled to compensation of intangible damages. If there is a causal relation between the malpractice and the side effects, the patient may also be able to recover damages for those side effects. In addition, both BCI and DBS involve the implantation of electrodes or microchips in the brain, which are controlled by an external devices. Since implantable medical devices are subject to product liability laws, the patient may be able to sue the manufacturer for damages if the defect caused the adverse effects. Recently, Korea's medical device regulation mandated liability insurance system for implantable medical devices to strengthen consumer protection.

Influence of Heat Treatment Conditions on Temperature Control Parameter ((t1) for Shape Memory Alloy (SMA) Actuator in Nucleoplasty (수핵성형술용 형상기억합금(SMA) 액추에이터 와이어의 열처리 조건 변화가 온도제어 파라미터(t1)에 미치는 영향)

  • Oh, Dong-Joon;Kim, Cheol-Woong;Yang, Young-Gyu;Kim, Tae-Young;Kim, Jay-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.619-628
    • /
    • 2010
  • Shape Memory Alloy (SMA) has recently received attention in developing implantable surgical equipments and it is expected to lead the future medical device market by adequately imitating surgeons' flexible and delicate hand movement. However, SMA actuators have not been used widely because of their nonlinear behavior called hysteresis, which makes their control difficult. Hence, we propose a parameter, $t_1$, which is necessary for temperature control, by analyzing the open-loop step response between current and temperature and by comparing it with the values of linear differential equations. $t_1$ is a pole of the transfer function in the invariant linear model in which the input and output are current and temperature, respectively; hence, $t_1$ is found to be related to the state variable used for temperature control. When considering the parameter under heat treatment conditions, $T_{max}$ was found to assume the lowest value, and $t_1$ was irrelevant to the heat treatment.

In vitro Cytotoxicity Evaluation of Polydimethylsiloxane as a Biosensor Coating Material (바이오센서 코팅용 Polydimethylsiloxane의 생체외 세포독성 평가)

  • Park, Subeom;Lee, Jonghwan;Na, Kyunga;Jung, Jaeyeon;Kim, Myungjin;Park, Sungjae;Hyun, Jinho
    • Journal of Adhesion and Interface
    • /
    • v.10 no.2
    • /
    • pp.77-83
    • /
    • 2009
  • PDMS was selected for a coating material of implantable biosensors and the cytotoxicity of extracts released from a polymer was evaluated using ISO 10993-5, Biological evaluation of medical devices-Part 5: Tests for in vitro cytotoxicity. Organo-tin was used as a positive control and a medium without serum was used as a negative control. Materials extract were prepared by incubating specimens in RPMI medium without serum ($125{\mu}L/cm^2$) for 24 h, 1 week and 6 weeks at $38^{\circ}C$. The evaluation of cytotoxicity was performed by two different methods : 1) seeding cells with extracts at the beginning 2) incubating extracts with cell sheets already formed on the plate. Both cell morphology and MTT numerical data were shown for the confirmation of cytotoxicity and cell spreading on the surface of PDMS.

  • PDF