• 제목/요약/키워드: Implantable

검색결과 307건 처리시간 0.029초

완전 이식형 보청기 기술 평가 기반의 새로운 이식형 음향센서 제안 (Proposition of a New Implantable Acoustic Sensor Based on Technology Evaluation of Fully Implantable Hearing Aids)

  • 조진호;우승탁;임형규;정의성;이정현;이승하;성기웅
    • 센서학회지
    • /
    • 제23권3호
    • /
    • pp.178-184
    • /
    • 2014
  • Key components of implantable hearing aids are consist of an acoustic sensor that collect external sound by suppressing the body noise, a signal processor module for compensation algorithm of hearing loss, and a output transducer which has tiny size but have high efficiency, respectively. In the partial implantable hearing aids, technologies of transducer and signal processor are so matured that can be applied not too much difficulty. However, due to the difficulties in implantable acoustic sensor technology, such as minimization of masticatory sound and damage of sensor's membrane from external impact, practical use of fully implantable hearing aids have not successful so far. In this paper, we have proposed a novel implantable acoustic sensor which has trans-tympanic structure, and is verified that the proposed method can be very useful for fully implantable hearing aids by cadaveric experiments.

피부에 의한 이득 감쇠를 줄이기 위한 FEA 시뮬레이션 기반의 이식형 마이크로폰 설계 및 구현 (Design and Fabrication of an Implantable Microphone for Reduction of Skin Damping Effect through FEA Simulation)

  • 한지훈;김민우;김동욱;성기웅;조성목;박일용;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.59-65
    • /
    • 2008
  • Nowadays, implantable hearing aids have been developed to solve the problems of conventional hearing aids. In case of fully implantable hearing aids, an implantable microphone is necessary to receive sound signal beneath the skin. Normally, an implantable microphone has poor frequency response characteristics in high frequency bands of acoustic signal due to the high frequency attenuation effect of skin after implantation to human body. In this paper, the implantable microphone is designed to reduce the high frequency attenuation effect of a skin by putting its resonance frequency at the attenuated range through a finite element analysis (FEA) simulation. The designed implantable microphone through the simulated results has been fabricated by manufacturing process using bio-compatible materials. By the several in-vitro experiments with pig skin, it has been verified that the designed implantable microphone has a resonance frequency around the starting part of the attenuated range and reduces the attenuation effect.

Wearable and Implantable Sensors for Cardiovascular Monitoring: A Review

  • Jazba Asad;Jawwad Ibrahim
    • International Journal of Computer Science & Network Security
    • /
    • 제23권7호
    • /
    • pp.171-185
    • /
    • 2023
  • The cardiovascular syndrome is the dominant reason for death and the number of deaths due to this syndrome has greatly increased recently. Regular cardiac monitoring is crucial in controlling heart parameters, particularly for initial examination and precautions. The quantity of cardiac patients is rising each day and it would increase the load of work for doctors/nurses in handling the patients' situation. Hence, it needed a solution that might benefit doctors/nurses in monitoring the improvement of the health condition of patients in real-time and likewise assure decreasing medical treatment expenses. Regular heart monitoring via wireless body area networks (WBANs) including implantable and wearable medical devices is contemplated as a life-changing technique for medical assistance. This article focuses on the latest development in wearable and implantable devices for cardiovascular monitoring. First, we go through the wearable devices for the electrocardiogram (ECG) monitoring. Then, we reviewed the implantable devices for Blood Pressure (BP) monitoring. Subsequently, the evaluation of leading wearable and implantable sensors for heart monitoring mentioned over the previous six years, the current article provides uncertain direction concerning the description of diagnostic effectiveness, thus intending on making discussion in the technical communal to permit aimed at the formation of well-designed techniques. The article is concluded by debating several technical issues in wearable and implantable technology and their possible potential solutions for conquering these challenges.

벨로즈형 진동체를 갖는 반이식형 인공중이용 신호처리회로 설계 (Design of Signal Processing Circuit for Semi-implantable Middle Ear Hearing Device with Bellows Transducer)

  • 김종훈;신동호;성기웅;조진호
    • 재활복지공학회논문지
    • /
    • 제11권1호
    • /
    • pp.63-71
    • /
    • 2017
  • 본 논문에서는 달팽이관의 정원창 이식용으로 최근 새롭게 제안된 3코일 벨로우즈형 진동체(tri-coil bellows transducer, TCBT)를 이용하는 반이식형 인공중이(semi-implantable middle ear hearing device)를 위한 신호처리회로를 설계하였다. 설계된 반이식형 인공중이는 높은 효율을 가지는 유도결합 방법을 이용하여 귀 뒤편에 착용되는 체외기와 대응되는 피부 내측에 위치하는 체내기 간에 데이터를 전송한다. 귀 뒤 부위의 피부두께를 포함하는 반이식형 인공중이의 송수신 거리를 고려하여 송수신 코일과 신호처리 회로를 설계 및 구현하였다. 또한 데이터 전송 효율을 높이기 위하여, 전력을 충분히 증폭하기 위한 체외기의 출력부도 설계 하였다. 유도결합 방식을 이용한 반이식형 인공중이의 동작을 확인하기 위하여, PSpice를 이용하여 회로해석을 수행하였으며, 활용 가능한 크기의 신호처리 보드를 제작하여 그 성능을 검증하였다.

능동형 임플란터블 디바이스 기술동향: BCI 응용 중심 (Active Implantable Device Technology Trend: BCI Application Focus)

  • 이성규;변춘원;김이경;박형일
    • 전자통신동향분석
    • /
    • 제32권6호
    • /
    • pp.27-39
    • /
    • 2017
  • A variety of medical devices are utilized to repair or help injured body functions after accidental injury(such as a traffic accident), population aging, or disease. Such medical devices are being actively researched and developed in portable form, skin patchable type, and further, implantable form. In the future, active implantable medical devices for neuro and brain sciences are expected to be developed. Active implantable medical devices that detect brain signals and control neurology for a wider understanding of human cognition and nerve functions, and for an understanding and treatment of various diseases, are being actively pursued for future use. In this paper, the core elements of implantable devices that can be applied to neuro and brain sciences are classified into electrode technologies for bio-signal acquisition and stimulation, analog/digital circuit technologies for signal processing, human body communication technologies, wireless power transmission technologies for continuous device use, and device integration technologies to integrate them. In each chapter, the latest technology development trends for each detailed technology field are reviewed.

다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작 (Manufacture of Custom IC and System for Multi-channel Biotelemeter)

  • 서희돈;박종대
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

Automatic Implantable Cardioverter Defibrillator (AICD)를 삽입한 환자에서 프로포폴, 레미펜타닐을 이용한 진정요법 하 제3대구치 발치 -증례보고- (A Case Report of the Patient Implanted with Automatic Implantable Cardioverter Defibrillator (AICD) Subject to 3rd Molar Extraction using Target Controlled Infusion of Propofol and Remifentanil -A Case Report-)

  • 신터전;서광석;김현정
    • 대한치과마취과학회지
    • /
    • 제9권2호
    • /
    • pp.116-118
    • /
    • 2009
  • The automatic implantable cardioverter defibrillator (AICD) has been widely used to treat recurrent malignant ventricular arrhythmia. Here, we case report 18 yr old patients implanted with Automatic implantable cardioverter defibrillator (AICD) who underwent surgical extraction under intravenous sedation and discuss the anesthetic implications for surgery.

  • PDF

이식형 중이 청각보조기를 위한 진동 트랜스듀서의 설계 (Design of Vibrating Transducer for Implantable Middle Ear Hearing Aid)

  • 박형욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.535-544
    • /
    • 1996
  • In this paper, we analyzed the coil-magnet type vibrating transducer for the implantable middle ear hearing aid which is appropriate for patient's hearing level, and an experimental transducer system is designed For the objective and quantitative analysis of the transducer, a theoretical equivalent model containing coil, magneto and inner ear is developed To perform effective evaluation of the transducer, a transforming ratio Tr is introduced and its range that is suitable for practical implantable middle ear hearing device is foun4 The result of applying physical parameters of ear system to the proposed analytical model shows that frequency response of the coil magrlet type vibrator is predominantly governed by resistive impedance of the coil rather than inertia effect of the magnet and the inner parameters. In addition, we realized an experimental middle ear hearing aid system to show the theoretical validity of designed system and this will provide the basis of the development for actually implantable system.

  • PDF

이식형 흡수성 융복합 의료제품 규제 비교 연구 -미국, 유럽, 한국을 중심으로- (A Comparative Study on the Regulations on Implantable Bioabsorbable Combination Products -Focusing on the U.S., Europe and Korea-)

  • 이현정;김미혜;설주은;김수동;김주희
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.414-427
    • /
    • 2023
  • Implantable bioabsorbable combination products undergo inherent degradation and systemic absorption within the physiological environment, thereby streamlining the therapeutic regimen and obviating the imperative for invasive extraction procedures. This inherent property not only enhances patient convenience and therapeutic efficacy but also underpins a paradigm of support characterized by heightened safety parameters. Within the regulatory landscapes of Korea, the United States, and Europe, implantable bioabsorbable combination products are meticulously classified into distinct categories, either as pharmaceutical implants or as implantable medical devices, depending on their primary mode of action. This scholarly investigation systematically examines the regulatory frameworks governing implantable bioabsorbable combination products in South Korea, the United States, and Europe. Notable discrepancies across national jurisdictions emerge concerning regulatory specifics, including terminology, product classification, and product name associated with these products. The conspicuous absence of standardized approval regulations presents a formidable barrier to the commercialization of these advanced medical devices. This academic discourse passionately emphasizes the critical need for formulating and implementing a sophisticated regulatory framework capable of streamlining the product approval process, thereby paving the way for a seamless path to commercializing implantable bioabsorbable combination products.

고막이식형 마이크로폰을 위한 이식형 인공중이 적응 피드백 제거기 구현 (An Adaptive Feedback Canceller for Fully Implantable Hearing Device Using Tympanic Membrane Installed Microphone)

  • 김태윤;김명남;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.189-199
    • /
    • 2016
  • Many implantable hearing aids are being developed as alternatives to conventional hearing aids which has inconveniences for use and social stigma that make hearing-impaired people avoid to wear it. Particularly, the fully-implantable middle ear hearing devices (F-IMEHD) are being actively studied for mixed or sensorineural hearing impaired people. In development of F-IMEHD, the most difficult problem is improving the performance of implantable microphone. Recently, Cho et al. have studied the tympanic membrane installed microphone which has better sensitivity and is easier to operate on patient than the microphone implanted under the skin. But, it may cause howling problem due to the feedback signal via oval window and ossicle chain from the transducer on round window in the middle ear cavity, therefore, a feedback canceller is necessary. In this paper, we designed NLMS (normalized least mean square) adaptive feedback canceller for F-IMEHD with tympanic membrane installed microphone and a transducer implemented at round window, and computer simulation was performed to verify its operation. The designed adaptive feedback canceller has a delay filter, a 64 point FIR fixed filter and a 8-tap adaptive FIR filter. Computer simulation of the feedback path is modeled by using the data obtained through human cadaver experiment.