• Title/Summary/Keyword: Implant-supported denture

Search Result 116, Processing Time 0.026 seconds

PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION (하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석)

  • Cho Hye-Won;Kim Nan-Young;Kim Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES (임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가)

  • Seo Ji-Young;Shim June-Sung;Lee Jae-Hoon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.

Implants in conjunction with removable partial denture (임플란트를 이용한 국소의치 수복)

  • Kim, Seong-Kyun;Yoo, Soo-Yeon;Park, In-Phil;Lee, Joo-Hee
    • The Journal of the Korean dental association
    • /
    • v.49 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.

Distal-extension removable partial denture with anterior implant supported fixed prostheses in a maxillary edentulous patient: Case report (상악 완전 무치악 환자에서 임플란트 고정성 보철물을 지대치로 한 후방 연장 국소의치 수복 증례)

  • Gwon, Bora;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.375-383
    • /
    • 2018
  • Clinicians are faced with many difficulties when planning prosthodontic restorations with implants in a complete edentulous patient. When planning fixed implant prosthetics, it is often necessary to have additional surgery due to highly reduced alveolar bone, as well as high treatment costs and long-term treatment durations can be required. In addition, lack of interocclusal space can be a problem when planning implant supported overdentures. In this study, we planned to place a small number of implants on the anterior maxilla and used them as the abutments for distal-extension removable partial dentures on the posterior side in a maxillary fully edentulous patient. This would reduce the possibility of additional invasive operations such as alveolar bone graft, shorten the treatment time, and be relatively easy for elderly patients to burden. In this case, the patient was provided with a distal-extension removable partial denture and anterior implant fixed prostheses, which was similar to the previous one, and showed good adaptation, and chewing efficiency and esthetics was recovered.

Distal-Extension Removable Partial Denture with Anterior Implant Prostheses: Case Report (전치부 임플란트 보철을 이용한 후방연장 국소의치 수복)

  • Na, Hyun-Joon;Kang, Dong-Wan;Son, Mee-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In patients who used removable partial dentures for a long period of time, gradual alveolar bone resorption occurs in edentulous area. However, in residual teeth area, alveolar bone is maintained sound. This causes an imbalance in intermaxillary distance between a maxillae and a mandible which is intensified due to expansion in vertical and horizontal bone amount difference between the two area as time passes. As the result, this shows a substantial difference in vertical position according to the period of teeth loss even after residual teeth loss. As in this situation, a patient with bilaterally and anterio-posteriorly different intermaxillary distance, various prosthodontic problems can be caused in fixed implant prosthodontics and implant overdenture. This study shows a case in which implant-supported removable partial denture was fabricated considering residual alveolar bone height after teeth loss in a patient who had been using a distal extension removable partial denture for a long period of time. In anterior area with short intermaxillary distance, fixed prosthodontics were fabricated with implant placement and in posterior area with long intermaxillary distance, a removable partial denture was fabricated. Finally, a small number of implants were placed without additional surgery and economical and comfortable treatment results were shown.

Overdentures using newly designed metal ball attachment containing predetermined gap with stress breakers (일정한 간극으로 새롭게 고안된 완압형 볼 어태치먼트를 이용한 피개의치 수복)

  • Yoo, Jin-Joo;Kim, Man-Yong;Yoon, Joon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.311-318
    • /
    • 2017
  • Several types of attachments have been used for implant supported and/or retained overdentures. Locator is one of the stud type attachments and it has been generally used. However, the colored matrix is resilient and vulnerable to wear, so frequent post-insertion maintenance is needed. To solve this problem, it is necessary to introduce innovative attachment system. Overdentures using Air Gap attachment (AGA) has improved masticatory function and facial esthetics. AGA is made of metal, so it could be more resistant to wear or friction than the other resilient attachments. Nevertheless, AGA plays a role in stress breakers because it allows movement during denture movement with predetermined gap. In addition, both pre-existing implants and natural teeth were successfully used for connection of AGA. AGA could replace other unsplinted type of attachments. Overdentures using AGA could provide satisfactory result in terms of function, esthetics and retention. However, long term follow up is needed.

Implant supported fixed prosthesis for complete edentulous maxilla with severe alveolar ridge resorption: A case report (치조골 흡수가 심한 상악 완전 무치악 환자에서 임플란트 고정성 보철물을 이용한 수복 증례)

  • Choi, Yoon-Ji;Lee, Ji-Hyoun;Jhin, Min-Ju
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.152-159
    • /
    • 2016
  • Implant fixed prosthesis for the complete edentulous maxilla provides significant benefits in the aspects of functions and esthetics compared with the conventional denture. Implant supported fixed prosthesis are totally supported by implant, and thus stabilizes the prosthesis to the maximum degree as possible. Also, the improved retention and stability of fixed prosthesis enhance patients' psychological and psychosocial health. This clinical presentation describes a maxillary full arch implant-supported fixed prosthesis in complete maxillary edentulous patient who showed vertical and horizontal alveolar bone resorption in the anterior ridge. To rehabilitate the esthetics and proper lip support, the zirconia framework was fabricated and the pink porcelain was veneered to reproduce the natural gingival tissue. After 9 months of follow up, the restorations were maintained without complications and the patient was satisfied with the restoration both functionally and esthetically.

Prosthetic rehabilitation of marginal mandibulectomized patient using implant-supported removable partial denture (하악골 변연절제술 환자에서 임플란트를 지대치로 이용한 가철성 국소의치 수복 증례)

  • Baek, Chang-Hyun;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.126-131
    • /
    • 2016
  • Surgical management of oral cancer results in compromised masticatory and swallowing function which affects patient in social and psychological aspects due to reduced phonetic ability and facial deformity, thus, it is imperative to provide applicable prosthetic treatment to overcome such complications. This clinical study describes rehabilitation of a patient with squamous cell carcinoma treated with marginal mandibulectomy and implantation on preserved posterior portion of mandible to provide stability and support for subsequent denture treatment. Kennedy class IV removable partial denture has provided satisfactory results in esthetics and function. Bone level stability around implants was reported to be maintained during eight months of clinical observation.

Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure: A clinical case report

  • Agustin-Panadero, Ruben;Penarrocha-Oltra, David;Gomar-Vercher, Sonia;Ferreiroa, Alberto;Penarrocha-Diago, Miguel
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.264-270
    • /
    • 2015
  • This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The technique was used to rehabilitate a patient presenting an atrophic upper maxilla, with the insertion of 8 implants. No complications were reported at follow-up 3, 6 and 12 months after fitting of the prosthesis. This system offers solutions to the clinical and laboratory complications associated with hybrid prostheses, concealing emergence of the chimneys and improving implant-prosthesis hygiene.

Implant supported prosthetic rehabilitation of severely atrophic mandible with fixed detachable prosthesis (심하게 흡수된 하악골에서 fixed detachable prosthesis를 이용한 임플란트 지지 보철 수복증례)

  • Lee, Hak-Joo;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.180-186
    • /
    • 2017
  • Implant supported prostheses have improved the quality of lives of totally edentulous patients. However, there are some limitations on the number of implants related to the residual bone level or the economic concern and so on. In this situation, applying fixed detachable prosthesis with bilateral cantilevers can be considered. This clinical report describes implant supported prosthetic rehabilitation of a patient with severe bone resorption. The patient was satisfied and felt comfortable with upper complete denture and lower fixed detachable prosthesis.