Overdentures using newly designed metal ball attachment containing predetermined gap with stress breakers

일정한 간극으로 새롭게 고안된 완압형 볼 어태치먼트를 이용한 피개의치 수복

  • Yoo, Jin-Joo (Department of Prosthodontics, NHIS Ilsan Hospital) ;
  • Kim, Man-Yong (Department of Prosthodontics, NHIS Ilsan Hospital) ;
  • Yoon, Joon-Ho (Department of Prosthodontics, NHIS Ilsan Hospital)
  • 유진주 (국민건강보험 일산병원 치과 보철과) ;
  • 김만용 (국민건강보험 일산병원 치과 보철과) ;
  • 윤준호 (국민건강보험 일산병원 치과 보철과)
  • Received : 2017.05.02
  • Accepted : 2017.06.16
  • Published : 2017.07.31

Abstract

Several types of attachments have been used for implant supported and/or retained overdentures. Locator is one of the stud type attachments and it has been generally used. However, the colored matrix is resilient and vulnerable to wear, so frequent post-insertion maintenance is needed. To solve this problem, it is necessary to introduce innovative attachment system. Overdentures using Air Gap attachment (AGA) has improved masticatory function and facial esthetics. AGA is made of metal, so it could be more resistant to wear or friction than the other resilient attachments. Nevertheless, AGA plays a role in stress breakers because it allows movement during denture movement with predetermined gap. In addition, both pre-existing implants and natural teeth were successfully used for connection of AGA. AGA could replace other unsplinted type of attachments. Overdentures using AGA could provide satisfactory result in terms of function, esthetics and retention. However, long term follow up is needed.

임플란트 지지 혹은 유지 피개 의치에서 다양한 종류의 유지 장치가 사용되어 왔다. Locator는 stud type의 유지 장치 중 하나로 널리 사용되어 왔으나 그 matrix는 탄성을 가지며 쉽게 마모되는 경향이 있어, 보철물 장착 후 빈번한 유지 관리가 필요하다. 이러한 문제점을 해결하기 위하여 새로운 유지 장치의 도입이 요구되었다. 본 증례에서는 새로운 ball type 유지 장치인 Air Gap attachment (AGA)를 이용한 피개의치로 수복한 증례를 보고하고자 한다. AGA는 금속으로 제작되어 다른 탄성 유지 장치에 비해 마모 저항성이 높다. 그럼에도 불구하고, 의치가 움직일 때 일정한 간극을 통해 움직임을 허용함으로써 stress breaker로의 역할이 가능하도록 하였다. 또한 기존에 식립된 임플란트와 자연치 모두 AGA와 연결이 용이하여 다른 unsplinted type의 유지 장치를 대체할 수 있다. AGA를 이용한 피개의치에서 기능, 심미 및 유지력의 면에서 만족할 만한 결과를 얻어 이를 보고하는 바이며, 장기간의 경과 관찰을 요한다.

Keywords

References

  1. Budtz-Jorgensen E. Restoration of the partially edentulous mouth--a comparison of overdentures, removable partial dentures, fixed partial dentures and implant treatment. J Dent 1996;24:237-44. https://doi.org/10.1016/0300-5712(95)00075-5
  2. Chee W, Jivraj S. Treatment planning of the edentulous mandible. Br Dent J 2006;201:337-47. https://doi.org/10.1038/sj.bdj.4814041
  3. van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6. https://doi.org/10.1046/j.0905-7161.2003.00961.x
  4. Chaimattayompol N, Arbree NS. Assessing the space limitation inside a complete denture for implant attachments. J Prosthet Dent 2003;89:82-5. https://doi.org/10.1067/mpr.2003.13
  5. Cehreli MC, Karasoy D, Kokat AM, Akca K, Eckert SE. Systematic review of prosthetic maintenance requirements for implant-supported overdentures. Int J Oral Maxillofac Implants 2010;25:163-80.
  6. Cune M, Burgers M, van Kampen F, de Putter C, van der Bilt A. Mandibular overdentures retained by two implants: 10-year results from a crossover clinical trial comparing ball-socket and bar-clip attachments. Int J Prosthodont 2010;23:310-7.
  7. Krennmair G, Weinlander M, Krainhofner M, Piehslinger E. Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: a 3-year prospective study. Int J Prosthodont 2006;19:164-70.
  8. Bilhan H, Geckili O, Sulun T, Bilgin T. A quality-of-life comparison between self-aligning and ball attachment systems for 2-implantretained mandibular overdentures. J Oral Implantol 2011;37:167-73. https://doi.org/10.1563/AAID-JOI-D-10-00070
  9. Engelhardt F, Zeman F, Behr M, Hahmel S. Prosthetic complications and maintenance requirements in locator-attached implantsupported overdentures: A retrospective study. Eur J Prosthodont Restor Dent 2016;24:31-5.
  10. Turk PE, Geckili O, Turk Y, Gunay V, Bilgin T. In vitro comparison of the retentive properties of ball and locator attachments for implant overdentures. Int J Oral Maxillofac Implants 2014;29:1106-13. https://doi.org/10.11607/jomi.3621
  11. Rutkunas V, Mizutani H, Takahashi H. Influence of attachment wear on retention of mandibular overdenture. J Oral Rehabil 2007;34:41-51. https://doi.org/10.1111/j.1365-2842.2006.01640.x
  12. Grossmann Y, Nissan J, Levin L. Clinical effectiveness of implantsupported removable partial dentures: a review of the literature and retrospective case evaluation. J Oral Maxillofac Surg 2009; 67:1941-6. https://doi.org/10.1016/j.joms.2009.04.081
  13. Osman RB, Payne AG, Ma S. Prosthodontic maintenance of maxillary implant overdentures: a systematic literature review. Int J Prosthodont 2012;25:381-91.