• 제목/요약/키워드: Implant-abutment

검색결과 504건 처리시간 0.028초

치과용 주조 합금의 방전가공에 따른 표면 성분 변화 (Elemental alteration of the surface of dental casting alloys induced by electro discharge machining)

  • 장용철;이명곤
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

임플란트 지대주 모양에 따른 주위 연조직 반응에 관한 연구 (Soft tissue responses to differential shapes of the implant abutment)

  • 안수용;한종현;허성주;김태일;설양조;이용무;구영;이해준;정종평;한수부;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.167-177
    • /
    • 2006
  • 연구배경 임플란트에 관한 전통적인 연구들은 주로 임플란트 매식체와 골조직간의 결합에 중점을 두어왔다. 최근 임플란트의 심미적 관점에 대한 관심이 높아지면서 임플란트 주위 연조직의 재건 및 유지에 대한 연구들이 많이 이루어지고 있다. 이번 연구는 임플란트 주위 연조직이 임플란트 지대주의 모양에 따라 어떻게 반응하는지 알아보고자 한다. 연구방법 및 재료 2 마리의 성견을 대상으로, 먼저 하악의 모든 소구치를 발치하고, 3개월의 치유 기간 후에 각 4분악에 실험에 사용된 3개의 다른 모양의 지대주를 가진 임플란트를 식립하였다: (1) 위로 벌어진 모양의 지대주 (2) 안쪽으로 오목하게 좁아진 지대주 (3) 평행한 모양의 지대주. 식립 순서는 무작위로 하였으며, 3개월 후 실험동물을 희생하고 조직 표본을 얻었다. 조직 표본은 광학 현미경을 통해 관찰하고, 상피, 결합조직, 전체 연조직의 수직적 거리를 측정하여 비교하였다. 연구 결과 이번 연구에서 임플란트 주위의 연조직을 측정한 결과, 접합 상피는 1.21 ${\pm}$ 0.47 mm, 결합조직은 1.16 ${\pm}$ 0.39 mm, 전체 연조직 두께는 2.37 ${\pm}$ 0.47 mm로 이전의 연구들과 비슷한 결과를 보였다. 지대주 주위의 연조직 중 결합조직이 많은 부위에서는 여러 주행 방향의 교원 섬유들이 관찰되었다. 그 중에서 결합조직이 차단막으로써의 역할을 할 수 있도록 하는 원형으로 주행하는 교원 섬유들이 모든 지대주 모양에서 관찰되었다. 특히 오목하게 좁아진 모양을 가진 지대주에서는 오목하게 파인 부분으로 많은 원형으로 주행하는 교원 섬유들이 관찰되었다. 오목한 모양의 지대주는 다른 모양의 지대주에 비해서 측면 방향의 연조직 두께가 두꺼웠다. 특히 위로 벌어진 모양의 지대주에 비해서 두꺼운 연조직을 확보할 수 있었으며, 내부에 많은 결합조직 교원 섬유들을 관찰할 수 있었다. 결론 이번 연구에서 오목한 모양의 지대주가 연조직을 두껍게 유지하고, 많은 원형으로 주행하는 교원 섬유들을 확보할 수 있었다. 이를 통해 오목한 여태의 지대주가 연조직 유지에 더 유리하고, 따라서 심미적인 부위에서 연조직의 퇴축을 예방하는데 더 유리하다고 할 수 있다.

임플란트 나사에 적용되는 생역학적 원리: 문헌고찰 (Biomechanical considerations for the screw of implant prosthesis: A literature review)

  • 임소민;김대곤;박찬진;차민상;조리라
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.61-68
    • /
    • 2010
  • 연구 목적: 임플란트 보철물의 유지 나사에 적용되는 전하중은 나사를 조임으로써 임플란트와 지대주 사이에 인장력이 발생하면서 나사가 신장되는 힘을 말한다. 이 연구는 전하중에 영향을 미치는 생역학적 요인들과 나사 풀림에 기여하는 다양한 요인에 대하여 문헌을 고찰하고자 하였다. 연구 재료 및 방법: 1981년부터 2009년까지 발표된 나사 풀림을 다룬 임상연구 중 설정한 기준에 합당한 문헌을 요약하여 나사 풀림의 빈도를 밝혔고 나사의 안정성과 전하중에 관한 생역학을 다룬 문헌을 조사하고 요약하였다. 또한, 본 교실에서 연구한 실험실적 결과도 포함시켰다. 결과 및 결론: 나사 풀림의 정도는 나사에 토크를 가하는 기술이 발달함에 따라 현저히 감소하고 있다. 그 외에도 나사의 재질, 마찰계수를 감소시키기 위한 피복 기술의 발달 및 나사산의 모양 등 전하중에 영향을 줄 수 있는 요인을 고찰하였다. 전하중이 일정 수준 이하로 떨어지게 되면 나사의 움직임이 발생하게 되는데 이는 장기적으로 축적되어 피로파절 및 응착 마모, 소성 변형 등을 유발하게 되므로 주의해야 한다. 최적의 전하중을 주기 위해서는 토크 렌치를 이용하고 환자의 재내원시 다시 토크를 가하는 방법 등이 추천된다.

가철성 국소의치와 후방연장 계속가공의치를 장착한 환자의 치주 및 보철 상태 (PERIODONTAL AND PROSTHETIC FINDINGS IN PATIENTS TREATED WITH REMOVABLE PARTIAL DENTURES OR DISTALLY EXTENDING CANTILEVER BRIDGES)

  • 김정찬;한수부
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.635-645
    • /
    • 1993
  • This study was perfomed to investigate the prosthodontic and periodontal status of the abutment teeth in distally extending bridges(DEBs) (78 cases) and removable partial dentures(RPDs) (43 cases) for 122 patients (55 males and 57 females) visiting department of Periodontology, Seoul National University Hospital. The average wearing periods were 67.8 months for DEBs and 66.4 months for RPDs. 38.4% of the patients in DEBs and 35.9% in RPDs complainted of chewing discomfort and 22.6% and 24.4% were not chewing on the prosthodontically - treated sides, respectively. In DEBs, when the restoration for 2nd molar supported by 1st molar & 2nd premolar was grouped to type 1, 1st molar supported by 1st & 2nd premolars was type 2, and 1st & 2nd molars supported by 1st & 2nd premolars was type 3, there was a significant differences only in the tooth mobility score among clinical parameters (type 2>type 1>type 3). In RPDs, when bilateral free-end case was grouped to type 1, and unilateral case was type 2, there was a significant difference in the Gingival index (type 1>type 2). In DEBs, 62.8% of restoration were overcontoured, 72% had interproximal space closures, 30.5% overextended pontics and 86.6% overhanging margins. In RPDs, 24.4% of the restorations were overcontoured, 45.5% had interproxinal space closures and 58.3% overhanging margins. From these results of this study, periodontal problems caused by prosthodontic defects were considered to be contributing factors in chewing discomfort.

  • PDF

${Fe_2}{O_3}$ 첨가에 따른 t-$ZrO_2$/${Al_2}{O_3}$ 복합체의 기계적 및 광학적 특성 (Effect of ${Fe_2}{O_3}$ Addition on Mechanical and Optical Properties of t-$ZrO_2$/${Al_2}{O_3}$ Composites)

  • 이득용;김대준;이명현;박일석;최현
    • 한국세라믹학회지
    • /
    • 제37권4호
    • /
    • pp.354-358
    • /
    • 2000
  • Tetragonal (t)-ZrO2/Al2O3 composites doped with Y2O3, Nb2O5, and Fe2O3 ((Y, Nb, Fe)-TZP/Al2O3) were prepared over the range containing Fe2O3 from 0.1 to 0.5 mol% with 0.1 mol% intervals to evaluate the effect of Fe2O3 addition on chromaticity, hydrothermal stability, and mechanical property of the composites. After autoclaving for 20 h at 18$0^{\circ}C$ under 3.5 MPa water vapor pressure, no tlongrightarrowm phase transformation was observed probably due to the preferential solid solubility of Fe2O3 in Al2O3, the presence of the rigid Al2O3 particles, and the inherent phase stability of (Y, Nb)-TZP. The optimized strength and the fracture toughness of the composite were 700 MPa and 8.5 MPa.m1/2, respectively, when 0.1 mol% Fe2O3 was added. The composites have shown a gradual color change from a slightly white ivory to a pale yellowish brown with increasing the Fe2O3 concentration.

  • PDF

Effectiveness of porcine-derived xenograft with enamel matrix derivative for periodontal regenerative treatment of intrabony defects associated with a fixed dental prosthesis: a 2-year follow-up retrospective study

  • Kim, Yeon-Tae;Jeong, Seong-Nyum;Lee, Jae-Hong
    • Journal of Periodontal and Implant Science
    • /
    • 제51권3호
    • /
    • pp.179-188
    • /
    • 2021
  • Purpose: Due to the difficulty of the hygienic care and sanitary management of abutment teeth and subpontic areas associated with fixed dental prostheses (FDPs), intrabony defects occur and accelerate due to the accumulation of plaque and calculus. This study aimed to evaluate the efficacy of regenerative periodontal surgery for intrabony defects associated with FDPs. Methods: The study inclusion criteria were met by 60 patients who underwent regenerative treatment between 2016 and 2018, involving a total of 82 intrabony defects associated with FDPs. Periodontal osseous lesions were classified as 1-, 2-, and 3-wall intrabony defects and were treated with an enamel matrix derivative in combination with bone graft material. The changes in clinical (pocket probing depth [PPD] and clinical attachment level [CAL]) and radiographic (defect depth and width) outcomes were measured at baseline and at 6, 12, and 24 months. Results: Six months after regenerative treatment, a significant reduction was observed in the PPD of 1-wall (P<0.001), 2-wall (P<0.001), and 3-wall (P<0.001) defects, as well as a significant reduction in the CAL of 2-wall (P<0.001) and 3-wall (P<0.001) intrabony defects. However, there was a significant increase in the CAL of 1-wall intrabony defects (P=0.003). Radiographically, a significant reduction in the depth of the 3-wall (P<0.001) defects and a significant reduction in the width of 2-wall (P=0.008) and 3-wall (P<0.001) defects were observed. The depth decreased in 1-wall defects; however, this change was not statistically significant (P=0.066). Conclusions: Within the limitations of the current study, regenerative treatment of 2- and 3-wall intrabony defects associated with FDPs improved clinical and radiological outcomes. Additional prospective studies are necessary to confirm our findings and to assess long-term outcomes.

Investigation of the marginal fit of a 3D-printed three-unit resin prosthesis with different build orientations and layer thicknesses

  • Yang, Min-Seong;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.250-261
    • /
    • 2022
  • PURPOSE. The purpose of this study was to analyze the marginal fit of three-unit resin prostheses printed with the stereolithography (SLA) method in two build orientations (45°, 60°) and two layer thicknesses (50 ㎛, 100 ㎛). MATERIALS AND METHODS. A master model for a three-unit resin prosthesis was designed with two implant abutments. Forty specimens were printed using an SLA 3D printer. The specimens were printed with two build orientations (45°, 60°), and each orientation was printed with two layer thicknesses (50 ㎛, 100 ㎛). The marginal fit was measured as the marginal gap (MG) and absolute marginal discrepancy (AMD), and MG and AMD measurements were performed at 8 points per abutment, for 16 points per specimen. All statistical analyses were performed using SPSS software. Two-way analysis of variance (ANOVA) was separately performed on the MG and AMD values of the build orientations and layer thicknesses. Moreover, one-way ANOVA was performed for each point within each group. RESULTS. The margins of the area adjacent to the pontic showed significantly high values, and the values were smaller when the build orientation was 45° than when it was 60°. However, the margin did not differ significantly according to the layer thicknesses. CONCLUSION. The marginal fit of the three-unit resin prosthesis fabricated by the SLA 3D method was affected by the pontic. Moreover, the marginal fit was affected by the build orientation. The 45° build orientation is recommended.

스프린팅이 하악 구치부 임플랜트 보철물의 응력분산에 미치는 영향에 관한 삼차원 유한요소분석 연구 (A three-dimensional finite-element analysis of influence of splinting in mandibular posterior implants)

  • 백상현;허성주;장익태;곽재영;김성균
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.157-168
    • /
    • 2008
  • 연구목적: 골유착성 임플랜트를 이용한 치료가 초기의 완전 무치악 증례에 도입된 이후 장기간의 임상 관찰 결과 높은 성공률이 보고되고 있으며, 점차 부분 무치악 및 단일치 상실 증례 등의 다양한 영역으로 확대되고 있다. 하지만 이러한 임플랜트에 가해지는 저작압은 임플랜트와 주위 골에 축 방향 힘 (axial force)과 다양한 측방 모멘트 (bending moments)를 일으키는데 이러한 응력의 적절한 분산이 치료의 성공에 큰 영향을 미치게 한다. 이번 연구의 목적은 하악 구치부가 부분 무치악일 때 외측연결 방식과 내측연결 방식의 임플랜트로 수복함에 있어 상부 보철물의 연결 (splinting)이 임플랜트와 주위 골로의 응력분산에 미치는 영향을 삼차원 유한요소 분석을 통해 비교해보고자 하였다. 연구재료 및 방법: 외측연결 방식과 내측연결 방식의 대표적인 2종의 임플랜트를 선정하였고 각각 8.5mm와 13mm 길이에 대하여 실험하였다. 임플랜트는 외측연결 방식을 대표하는 브레네막 시스템을, 내부연결 방식을 대표하는 ITI 임플랜트를 연구재료로 선택하였다. 각각의 임플랜트는 구치부에서 골양이 허용되는 한 추천되는 넓은 직경 (wide diameter)의 임플랜트 (4.8-5.3mm)를 이용하였다. 이러한 4종류의 임플랜트 모형에서 제1대구치와 제2대구치 금관의 연결 여부에 따라 총 8개의 실험 군으로 분류하였다. 하중은 수직하중 및 수평하중을 각각 100N씩 하악 제1대구치 임플랜트 보철부위 (금관부)에 가하였고 금관의 연결여부에 따라 임플랜트와 주위골에 응력이 분산되는 양상을 관찰하였다. 삼차원 유한요소분석을 위한 하악골모형 제작에는 Hypermesh (Altair Engineering Inc., Troy, MI, USA)를 사용하였고 응력해석을 위해서는 PAM-CRASH 2G version 2005 (ESI, France), 포스트프로세싱을 위해서는 PAM-VIEW version 2005 (ESI, France)을 이용하였다. 여러 응력값 중에서 대표적인 등가응력 (von Mises stress)을 이용하여서 응력분포를 비교분석하였다. 연구결과: 내부연결방식과 외부연결방식 모두 상부의 금관을 연결함에 따라 임플랜트와 주위골로 전해지는 응력값이 감소하였다. 그리고 응력값이 감소하는 정도는 외부연결방식에서 더 크게 나타났다. 하지만 두 방식 모두 금관연결에 따른 응력 감소 효과는 임플랜트 길이 증가에 의해 영향 받지는 않았다. 이번 실험에서 상부 보철물이 연결되지 않은 상태에서 제1대구치 부위에 수직방향 또는 수평방향의 하중을 가했을 때 외부연결방식에서 더 많은 양의 응력이 주변 피질골의 상부 좁은 부위로 전달되었다. 하지만 상부 보철물을 연결한 상태에서 하중을 가한 경우에는 외부연결방식에서 하중 측인 제1대구치 부위에서 나타나던 상부 피질골에서의 응력 집중이 많이 감소한 것을 보여주었다. 또 한 비하중 측인 제 2대구치 부위에서의 응력분산도 외부연결방식에서 더 많은 것으로 나타났다. 이에 비해 내부연결방식에서는 하중 측인 제 1대구치 부위에서 지대주 나사를 따라 높게 나타나던 응력값의 중등도 감소 효과를 나타내었고 연결된 제2대구치 부위로의 응력분산 효과도 작았다. 결론: 하악 구치부가 결손한 하악골에 내부연결방식과 외부연결방식을 대표하는 두 가지 종류의 임플랜트를 선택하여 상부 금관의 연결이 임플랜트와 주위 골의 응력 분산에 미치는 영향에 대하여 삼차원 유한요소분석을 하였다. 이러한 실험 결과를 통하여 다음과 같은 결과를 얻었다. 1. 8.5mm와 13mm에 대해서 응력 분포는 거의 동일하게 나타나고, von Mises stress 최대값 또한 거의 유사하였다. 2. 수직하중에서는 근심측에서 응력이 집중되었고 수평하중에서는 근, 원심측이 비슷한 크기의 응력을 보였다. 3. 내부연결방식에서는 지대주 나사의 벽면을 따라서 응력이 분산되는 양상을 보였으나 외부연결방식에서는 지대주에 눌리는 임플랜트 상부 부위에 응력이 집중되었다. 4. 금관을 연결함에 따라 임플랜트와 주위골로 전달되는 응력 값은 두 방식 모두 감소하는 모습을 보였으나 응력 값이 감소하는 정도는 내부연결방식에 비해 외부연결방식에서 더 크게 나타났다.

다른 연결 시스템을 갖는 임플랜트 상부 구조물에서 조임술식에 따른 지대주 나사의 풀림 토크값에 대한 연구 (Removal Torque Values of Retaining Screws Tightened to Implant-Supported Prosthesis with Different Connection Systems by Various Tightening Technique)

  • 김동욱;최유성;조인호
    • 구강회복응용과학지
    • /
    • 제27권4호
    • /
    • pp.343-358
    • /
    • 2011
  • 임플랜트 치료가 보편화되고, 다양한 형태와 재료의 상부 구조물이 보급되었다. 그리고 실패에 대한 보고도 다양하며, 그 중 지대나사의 풀림현상이 가장 흔하다고 지적되고 있다. 본 연구는 외부연결구조와 내부연결구조 임플랜트에 의해 지지되는 상부 구조물을 나사로 연결할 때, 세 가지 나사조임순서와 두 가지 나사조임방법에 따른 나사의 풀림 토크값을 비교하여 나사조임순서와 나사조임방법이 서로 다른 연결구조에 따라 나사풀림현상에 미치는 영향을 알아보고자 하였다. 완전 무치악 하악모형을 자가중합형 아크릴릭 레진으로 제작하고 이공간 부위에 중심간 거리가 약 15 mm 되도록 네 개의 임플랜트 고정체 유사체를 고정한 후 바 타입으로 납형 형성하여 상부 구조물을 주조 제작하였다. 상부 구조물과 정확한 적합이 되는 주모형을 제작한 후 연결 인상법으로 외부연결구조, 내부연결구조를 가지는 연구모형을 각각 5개씩 제작하였다. 각 모형에서 각 나사의 풀림 토크값을 가장 왼쪽에 조여지는 나사를 1번 나사로 하고 가장 오른쪽의 나사를 4번 나사로 명명하였다. 먼저, 나사조임순서의 영향을 알아보기 위해 1-2-3-4, 2-3-1-4, 2-4-3-1의 순서로 15 Ncm의 힘으로 조이고, 다시 같은 순서로 최종 조임토크값인 30 Ncm까지 조인 후 (2-step 방법) 각 나사의 풀림 토크값을 측정하였다. 또한 나사조임방법의 영향을 알아보기 위해 2-3-1-4의 순서로 한 번에 최종 조임토크값인 30 Ncm까지 조인 후 (1-step 방법) 각 나사의 풀림 토크값을 측정하여 같은 순서 (2-3-1-4)의 2-step 방법과 비교하였다. 세 가지 나사조임순서에 따른 나사의 풀림 토크값은 외부연결구조에서 2-3-1-4군이 2-4-3-1군보다 유의하게 낮았다 (p<0.05). 그리고 내부연결구조에서도 2-3-1-4군이 2-4-3-1군과 1-2-3-4군보다 유의하게 낮았다 (p<0.05). 또한 나사조임순서와 무관하게 몇 번째 조여진 나사인지에 따른 풀림 토크값을 비교해 본 결과, 외부연결구조에서는 처음에 조여진 나사가 두 번째 조여진 나사보다 유의하게 높았으나 (p<0.05), 내부연결구조에서는 처음에 조여진 나사에서부터 마지막에 조여진 나사 간에 차이가 없었다. 그리고 두 가지 나사조임방법 간에는 외부연결구조와 내부연결구조 모두에서 통계학적으로 유의한 차이가 없었다. 연결구조에 대한 비교에서 외부연결구조와 내부연결구조의 풀림 토크값은 각각 16.27 Ncm, 14.25 Ncm 였으며, 통계적으로 유의한 차이가 나타났다 (p<0.05). 다수 임플랜트에 의해 지지되는 상부 구조물을 나사로 연결할 때, 나사조임순서에 따라 차이가 있었으며, 가운데부터 조인 경우에서 풀림 토크값이 낮았고, 연결구조 간에도 차이가 있었다. 풀림 토크값에 미치는 요인에 대해 좀 더 상세히 분석할 필요가 있으며, 하중 조건에서의 부가적인 연구가 필요할 것으로 사료된다.

지르코니아와 레진나노세라믹 임플란트 지대주의 두께에 따른 열순환 후 파절저항 (Fracture resistance of zirconia and resin nano ceramic implant abutments according to thickness after thermocycling)

  • 이정원;차현석;이주희
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.144-150
    • /
    • 2017
  • 목적: 이 연구의 목적은 심미적인 임플란트 지대주의 종류와 두께에 따른 파절 강도를 측정하여 구강 내 저작압에 견디는 최소한의 두께를 평가하기 위함이다. 재료 및 방법: 대조군으로 0.5 mm 두께의 티타늄 임플란트 지대주를(Ti-0.5), 실험군으로 지르코니아 임플란트와 레진 나노 세라믹 지대주를 사용하여 각각 0.5 mm, 0.8 mm, 1.0 mm 두께로 각 그룹에 10개씩 총 70개의 시편을 제작하였다(그룹Zir-0.5, Zir-0.8, Zir-1.0, RNC-0.5, RNC-0.8, RNC-1.0). 모든 시편은 파절 실험 이전에 열순환을 시행하여 구강 내에서의 사용을 재현한 후, universal testing machine을 이용하여 각 시편의 파절 강도를 측정하여 평균값을 측정하였다. 그룹들의 평균 파절 값을 측정하였으며 이원분산분석을 이용하여 통계학적으로 분석하였다. 결과: Zir-1.0군이 가장 높은 파절 강도 $2,476.3{\pm}342.0N$를 보였으며 뒤를 이어 Zir-0.8 ($1,518{\pm}347.9N$), Ti-0.5 ($1,041.8{\pm}237.2N$), Zir-0.5 ($631.4{\pm}149.0N$), 의 순이었다. RNC 그룹의 경우에 Ti와 Zir 그룹에 비교하여 유의하게 낮은 파절 강도값을 나타내었으며(RNC-1.0 $427.5{\pm}72.1$, RNC-0.8 $297.9{\pm}41.2$), 모든 실험군에서 지대주 두께가 감소할수록 파절 강도 값도 유의하게 감소했다(P < .01). RNC-0.5 ($127.4{\pm}35.3N$) 그룹은 다른 모든 군에 비해 유의하게 낮은 값을 보였다(P < .05). 결론: 이번 실험에서 사용된 모든 두께의 지르코니아 지대주는 전치부와 구치부의 교합압을 견딜 수 있는 정도의 파절 강도를 보여주었다. 레진 나노 세라믹 지대주의 경우 0.8 mm 두께 이상에서 전치부의 교합압을 견딜 수 있는 가능성을 보여주었다.