• Title/Summary/Keyword: Implant supported fixed denture

Search Result 76, Processing Time 0.016 seconds

Attitude and treatment options in implant-supported prosthetics: A survey among a cohort of German dentists

  • Glucker, Carolin;Rauch, Angelika;Hahnel, Sebastian
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • PURPOSE. The aim of the current study was to analyze treatment concepts of a cohort of German dentists for planning, fabrication, and maintenance of implant-supported fixed and removable restorations. MATERIALS AND METHODS. A questionnaire including queries about experiences with implant-supported restorations as well as prosthetic and maintenance treatment concepts for supplying patients with fixed and removable implant-supported prosthetic restorations was developed and sent to 350 dental offices registered in the municipal area of Leipzig, Germany. RESULTS. An overall total of 62 returned questionnaires were included in the analyses, which relates to a response rate of 17.7%. Participating dentists were more involved in the prosthetic aspects of implant dentistry rather than surgery, while prosthetic concepts such as backward planning, digital processing, and application of all-ceramic materials were not commonly performed. Simple attachments were preferred over complex retention systems in removable implant-supported restorations. Tooth/implant-supported fixed denture prostheses as well as removable denture prostheses with supporting posterior implants were not regarded as a favorable treatment option. CONCLUSION. Within the limitations of the study, the data indicate that dentists favor simple and conventional treatment approaches in implant prosthetics. Prosthetic aspects in the planning of implant-supported restorations are often neglected. Prosthetic treatment guidelines and aspects should commonly be considered in the planning phase of implant-supported prosthetic restorations, and awareness should be increased in postgraduate education.

Trend analysis of prosthodontic treatment modality between 2005 and 2008 in Seoul National University Dental Hospital

  • Li, Hongbo;Lee, Jai-Bong;Liu, Hongchen;Han, Jung-Suk;Yang, Jae-Ho;Koak, Jai-Young;Heo, Seong-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.4-6
    • /
    • 2010
  • PURPOSE. The aim of this article is to analyze the preference for treatment modality of dentists. MATERIAL AND METHODS. Data of 20,038 patients was involved. Data analysis were done by distribution according to the various kinds of prosthesis, including complete denture, removable partial denture, fixed partial denture, implant-supported dental prosthesis as well as distribution according to the professional titles of the dentists finishing the treatment, including resident and professors. RESULTS. The number of cases of dental prosthesis increased year by year. 61.06% of the patients accepted fixed partial denture restoration. The number of patients who accepted implant supported restoration is also increasing year by year. The number of complete denture, implant-supported dental prosthesis finished by professors was larger than that done by residents, while it was contrary for removable partial denture, fixed partial denture, and the difference was statistically significant (P < .05). CONCLUSION. Professors and residents have some difference in the categorization of prosthesis finished. Fixed partial denture and implant-supported dental prosthesis are preferred.

Implant supported over denture with O-ring abutment (O-ring abutment를 이용한 Implant over denture의 제작)

  • Lee, Sung-Uck;Lee, Jung-Hwan;Park, Hyo-Ryun
    • Journal of Technologic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.209-216
    • /
    • 2004
  • The purpose of this study is to introduce how to make implant supported over denture with Oring. Many kinds of attachments have used to dental restorations. The application of attachment has widely increased implant fixed prosthesis and implant supported over denture. In order that implant supported over denture have properly retention, generally used O-ring, magnetic, bar attachment. O-ring give us an advantage that is required more minimum vertical dimension than bar-type and easily replace with new part. When we make these prosthesis using O-ring, Bar, Ball attachment, we should following procedures. Strong occlusion force leads to fracture of over denture because part of functional mechanism as implant abutment or attachment is spaced. Clips are regularly activated. O-ring and springs are changed every year. The pattern of resorption should be carefully monitored and compensated for by relining procedures. If the over denture appears to rest on the bar or the ball attachments, relining should be performed and clips/caps should be changed.

  • PDF

An implant-supported removable partial denture for a patient with post-inflammatory scar contracture caused by burn complications: a clinical report

  • Kim, Jee-Hwan;Lee, Jae-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.57-59
    • /
    • 2012
  • The scars and contracture around the oral-facial region may cause difficulty in prosthodontic treatment to restore esthetics and function for the patients, who suffered severe burns. This article presents a technique that uses a fixed partial denture prepared with a conventional milling technique and an attachment to support anterior cantilever removable partial denture, thereby providing a more esthetically acceptable and functional result.

A case of removable partial denture restoration using implant supported surveyed crown in a maxillary edentulous patient (상악 무치악 환자에서 임플란트 지지 서베이드 크라운을 이용한 가철성 국소의치 수복 증례)

  • Seong, Si Young;Choi, Yeon Jo;Ryu, Jae Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.29-36
    • /
    • 2022
  • When planning oral rehabilitation for maxillary edentulous patients, fixed prosthetic restoration using implants, complete denture restoration or overdentures using implants can be considered as treatment methods. In the case of complete denture restoration, it does not require additional surgery and is relatively economical. In the case of implant-supported fixed prostheses, the functional part is generally superior to that of complete denture restoration, but there are cases in which implant placement is clinically difficult. Recently in consideration of the patient's needs and the condition of the remaining alveolar bone, after partial implant placement, a method of restoring with a removable partial denture using implant-supported surveyed crown is also being attempted. This case is a case of performing a removable partial denture restoration using implant-supported surveyed crown in the anterior maxilla, and showing satisfactory esthetic and functional results.

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.

Implant-assisted removable partial denture restoration in small number of residual teeth in mandible: A case report (하악 소수 잔존치 환자에서 임플란트 보조 국소의치 수복 증례)

  • Jong-Ha Park;Jee-Hwan Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.215-223
    • /
    • 2024
  • The patient in this case presented with a desire to have new dentures due to discomfort with existing ones. At the initial visit, all of teeth were missing except for the mandibular left second molar. As the patient was 65 years old, treatment with dentures and implant-supported prostheses was possible under the national health insurance system, and the patient opted for the mandibular denture using implant. Temporary prostheses were initially provided for patient adaptation, and following successful adaptation period, the treatment progressed. A maxillary complete denture and a mandibular implant-supported denture using two implants in the canines were fabricated. The mandibular denture is a Kennedy Class II removable partial denture which consists of a six-unit porcelain fused to metal fixed dental prostheses supported by the implant in the canines on both sides and left second molar serving as the abutments. Despite severe bone resorption and insufficient abutment teeth, the patient expressed satisfaction with the treatment results. In cases with economic and anatomical constraints affecting the feasibility of complete denture, implant-supported overdenture, and implant-supported fixed dental prostheses, an implant-assisted removable partial denture using implant surveyed crowns proves to be a viable and effective alternative treatment option. Nevertheless, the current dearth of scientifically rigorous studies underscores the necessity for meticulous regular check-up and occlusal assessment.

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

  • Yuan, Judy Chia-Chun;Sukotjo, Cortino
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.2
    • /
    • pp.51-57
    • /
    • 2013
  • Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices.

A STUDY OF PHOTOELASTIC STRESS ANALYSIS IN THE IMZ IMPLANT-NATURAL 700TH SUPPORTED FIXED PARTIAL DENTURE USING ATTACHMENT WITH OR WITHOUT RIGID CONNECTION (어태치먼트를 이용한 IMZ 임플랜트와 자연치의 연결시 고정유무의 연결형태에 따른 광탄성 응력분석에 관한 연구)

  • Kim, Jeong-Sun;Hwang, Young-Phil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.130-143
    • /
    • 1995
  • The purpose of this study was to analyze the magnitude and distribution of stress using photoelastic model with the rigid connection using T-block attachment and non-rigid connection using key & keyway attachment. The vertical load of 16 Kg was applied on the central fossa of the tooth, the pontic and the implant, and the pattern and distribution under each condition was analyzed. The following results were obtained : 1. In case of vertical load on the central fossa of the implant, the stress was concentrated at the apex of the implant involving the mesial alveolar bone in both fixed partial denture with the rigid connection and that with the nonrigid connection and the stress concentration at the mesial cervical area of the implant was a little more in the nonrigid connection than in the rigid connection. 2. In case of vertical load on the central fossa of the pontic, the stress was concentrated at the apex of 2nd bicuspid in both 3 unit fixed partial denture with nonrigid connection and that with the rigid connection. The stress was more concentrated at the mesial alveolar bone of the implant, but the stress distribution at the natural teeth more favorable at the rigid connection than at the non-rigid connection in case of 4 unit fixed partial denture. 3. In case of vertical load of the central fossa of the 2nd bicuspid, much stress with 3 fringe order was observed at the apex of the 2nd bicuspid in the 3 unit fixed partial denture, but relatively even stress distribution was observed at the apex of the implant, the 1st and 2nd bicuspid, and the adjacent cuspid in the 4 unit fixed partial denture.

  • PDF