• Title/Summary/Keyword: Implant fracture

Search Result 307, Processing Time 0.03 seconds

Atypical Vancouver B1 periprosthetic fracture of the proximal femur in the United Kingdom: a case report challenged by myeloma, osteoporosis, infection, and recurrent implant failures

  • Sayantan Saha;Azeem Ahmed;Rama Mohan
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.89-96
    • /
    • 2024
  • The indications for total hip replacement are increasing and not limited to osteoarthritis. Total hip replacement may also be done for trauma and pathological fractures in patients otherwise physiologically fit and active. This trend has led to an inevitable rise in complications such as periprosthetic femoral fracture. Periprosthetic femoral fracture can be challenging due to poor bone quality, osteoporosis, and stress fractures. We present a case of periprosthetic femoral fracture in a 71-year-old woman with some components of an atypical femoral fracture. The fracture was internally fixed but was subsequently complicated by infection, implant failure needing revision, and later stress fracture. She was on a bisphosphonate after her index total hip replacement surgery for an impending pathological left proximal femur fracture, and this may have caused the later stress fracture. Unfortunately, she then experienced implant breakage (nonunion), which was treated with a biplanar locking plate and bone grafting. The patient finally regained her premorbid mobility 13 months after the last surgery and progressed satisfactorily towards bony union.

FUNCTIONAL RECOVERY OF MANDIBULAR HIGH CONDYLAR FRACTURE PATIENT WITH IMMEDIATE PROVISIONAL IMPLANT: CASE REPORT (Immediate provisional implant를 이용한 하악골 high condylar fracture환자의 기능회복: 증례보고)

  • Jang, Bo-Young;Ahn, Mi-Ra;Ahn, Kyung-Mi;Lee, Won-Hyuk;Shon, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.1
    • /
    • pp.82-88
    • /
    • 2005
  • Treatment methods of mandibular condylar fracture were conservative and surgical method. Surgical method of mandibular high condylar fracture was very difficult because approach and internal fixation of small size fracture fragment were difficult. So there is a tendency to select conservative method over surgical method for guiding a stable occlusion and avoiding TMJ disorder and growth disturbance, minimizing pain and deviation during function. But, in case of mandibular high condylar fracture patient who has no biting teeth on posterior teeth area, guiding a stable occlusion and conservative functional treatment were very difficult. In this case, patient was 62years old male. He had fracture of mandibular symphysis, right mandibular body, left mandibular high condyle. We treated the patient for mandibular symphysis and right mandibular body fracture area with surgical method. But left mandibular high condylar fracture area was difficult to treat with surgical method. So we selected a conservative functional method on left mandibular high condylar fracture area. We intended recovery of vertical dimension and stable occlusion with implantation of immediate provisional implant on maxillar and mandibular posterior teeth area, and temporary crown. And then patient did mandibular functional movement and his mandibular function was recoverd.

In vitro performance and fracture resistance of novel CAD/CAM ceramic molar crowns loaded on implants and human teeth

  • Preis, Verena;Hahnel, Sebastian;Behr, Michael;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.300-307
    • /
    • 2018
  • PURPOSE. To investigate the fatigue and fracture resistance of computer-aided design and computer-aided manufacturing (CAD/CAM) ceramic molar crowns on dental implants and human teeth. MATERIALS AND METHODS. Molar crowns (n=48; n=8/group) were fabricated of a lithium-disilicate-strengthened lithium aluminosilicate glass ceramic (N). Surfaces were polished (P) or glazed (G). Crowns were tested on human teeth (T) and implant-abutment analogues (I) simulating a chairside (C, crown bonded to abutment) or labside (L, screw channel) procedure for implant groups. Polished/glazed lithium disilicate (E) crowns (n=16) served as reference. Combined thermal cycling and mechanical loading (TC: $3000{\times}5^{\circ}C/3000{\times}55^{\circ}C$; ML: $1.2{\time}10^6$ cycles, 50 N) with antagonistic human molars (groups T) and steatite spheres (groups I) was performed under a chewing simulator. TCML crowns were then analyzed for failures (optical microscopy, SEM) and fracture force was determined. Data were statistically analyzed (Kolmogorow-Smirnov, one-way-ANOVA, post-hoc Bonferroni, ${\alpha}=.05$). RESULTS. All crowns survived TCML and showed small traces of wear. In human teeth groups, fracture forces of N crowns varied between $1214{\pm}293N$ (NPT) and $1324{\pm}498N$ (NGT), differing significantly ($P{\leq}.003$) from the polished reference EPT ($2044{\pm}302N$). Fracture forces in implant groups varied between $934{\pm}154N$ (NGI_L) and $1782{\pm}153N$ (NPI_C), providing higher values for the respective chairside crowns. Differences between polishing and glazing were not significant ($P{\geq}.066$) between crowns of identical materials and abutment support. CONCLUSION. Fracture resistance was influenced by the ceramic material, and partly by the tooth or implant situation and the clinical procedure (chairside/labside). Type of surface finish (polishing/glazing) had no significant influence. Clinical survival of the new glass ceramic may be comparable to lithium disilicate.

Clinical and Radiological Outcomes of Hook Plate Fixation in the Lateral End Fracture of the Clavicle and Acromioclavicular Dislocation

  • Min, Young Kyoung;Kim, Jung Han;Gwak, Heui Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.4
    • /
    • pp.209-215
    • /
    • 2016
  • Background: The purpose of this study was to identify the clinical and radiological outcomes of hook plate fixation for lateral end fracture of the clavicle and acromioclavicular dislocation. Methods: There were a total of 20 cases with lateral end fracture of the clavicle and 16 cases with acromioclavicular dislocation. All patients were evaluated for range of motion, functional score by using Constant score, and American Shoulder and Elbow Surgeons shoulder index at just before implant removal and at final follow-up. Coracoclavicular distance was measured in acromioclavicular dislocation and bony union was evaluated in the lateral end fracture of the clavicle. Results: The clinical outcomes and range of motion were increased at the final follow-up compared with just before implant removal in both the lateral end fracture of the clavicle and acromioclavicular dislocation. In acromioclavicular dislocation, all cases-except one-showed maintenance of reduction after implant removal. Moreover, in the lateral end fracture of the clavicle, all cases-except one-showed bony union. Conclusions: Hook plate fixation in the lateral end fracture of the clavicle and acromioclavicular dislocation resulted in good clinical and radiological results.

Autograft Surgery Using the Condylar Fragment for Implant Placement

  • Kim, Yeo-Gab;Kwon, Yong-Dae;Yoon, Byung-Wook;Choi, Byung-Joon;Yu, Yong-Jae;Lee, Baek-Soo
    • Journal of Korean Dental Science
    • /
    • v.1 no.1
    • /
    • pp.10-14
    • /
    • 2008
  • The fracture of facial bone usually accompanies alveolar bone fracture and dislocation or fracture of teeth. Thus, aside from the reduction of fracture, the reconstruction of occlusion through the rehabilitation of lost teeth should be considered. The dislocation of tooth after trauma accompanying alveolar bone fracture needs bone grafting in case of implant treatment. Although autogenous bone graft shows good prognosis, it has the disadvantage of requiring a secondary surgery. This is a case of a mandibular condyle head fracture accompanied by alveolar bone fracture. The condylar head fragment removed during open reduction was grafted to the alveolar bone fracture site, thereby foregoing the need for secondary surgery.

  • PDF

Effects of TiN Coating on the Fatigue Fracture of Dental Implant System with Various Cyclic Loads

  • Jung, Da-Un;Chung, Chae-Heon;Son, Mee-Kyoung;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.6
    • /
    • pp.283-291
    • /
    • 2015
  • The purpose of this study was to investigate effects of TiN coating on the fatigue fracture of dental implant system with various cyclic loads. TiN coated abutment screw, the fixture, and abutment of internal hex type were prepared for fatigue test. The fatigue test was carried out according to ISO 14801:2003(E) using tensile and compression tester with repeated load from 30% to 80% of static fracture force. Morphology and fractured surface was observed by field emission scanning electron microscope(FE-SEM) and energy dispersive X-ray spectroscope(EDS). The fracture cycle drastically decreased as repeated load increased. Especially, in the case of TiN-coated abutment screw, fracture cycle increased compared to non-coated abutment screw. The fatigue crack was propagated fast as repeated load increased. The plastic deformation region decreased, whereas, cleavage fracture region increased as repeated load increased.

Clinical and scanning electron microscopic analysis of fractured dental implants: a retrospective clinical analysis

  • Kwon, Kyung-Hwan;Sim, Kyu-Bong;Cha, Jae-Won;Kim, Eun-Ja;Lee, Jae-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.371-378
    • /
    • 2012
  • Many longitudinal studies have reported the successful osseointegration of dental implants, with survival rates approaching 90-95%. However, implants regarded as a "success" may have also failed to undergo osseointegration. A variety of complications and failures have been observed, including implant fracture - a rare and delayed biomechanical complication with serious clinical outcomes. Given the increasing popularity of dental implants, an increase in the number of failures due to late fractures is expected. This study sought to determine the rate of implant fractures and factors associated with its development. This retrospective evaluation analyzed implants placed at Wonkwang Dental Hospital (from 1996 to the present). In our study we found that the frequency of dental implant fractures was very low (0.23%, 8 implant fractures out of 3,500 implants placed). All observed fractures were associated with hybrid-surface threaded implants (with diameter of 4.0 or 3.75 mm). Prosthetic or abutment screw loosening preceded implant fracture in a majority of these cases.

TWO PART MINI-IMPLANT AS AN EFFICIENT TOOL FOR INTERMAXILLARY FIXATION (분리형 미니 임플란트를 이용한 효과적인 악간고정법의 소개)

  • Lee, Won;Kim, In-Soo;Seo, Woon-Kyung;Heo, Hyun-A;Kim, Seong-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.477-482
    • /
    • 2006
  • The new type of orthodontic mini-implant named C-implant can be an effective alternative to conventional one-component mini-implant in the intermaxillary fixation (IMF) cases because of its particular design. The small size, two-part design, efficiency, and low cost of the C-implant make it applicable to various types of IMF cases easily such as fracture reduction and orthognathic surgery. The two part design resists highly to the fracture or deformation during implantation and removal. The long span head allows the patient to easily attach intermaxillary elastics, so that the patient can apply intermaxillary elastics for traction easily. Through this article, we tried to show the possibility of this appliance as a good adjunct for the IMF screw.

Mandibular Fracture in a Hemifacial Microsomia Patient following Implant Failure and Hardware Infection: A Case Report

  • Ali, Kausar;Dibbs, Rami P.;Maricevich, Renata S.
    • Archives of Plastic Surgery
    • /
    • v.49 no.5
    • /
    • pp.642-647
    • /
    • 2022
  • Hemifacial microsomia (HFM) is a complex congenital condition with heterogeneous malformations of the facial skeleton that almost always involves mandibular hypoplasia. Here we introduce a unique case in which a patient with HFM had initially successful optimization of facial symmetry using a polyetheretherketone implant for mandibular augmentation. However, multiple factors associated with the intraoperative and postoperative course, including hardware failure and infection, led to diminished mechanical strength of the mandible, ultimately resulting in a mandibular fracture. In this unique case presentation of HFM, we discuss the various factors that contributed to mandibular weakness and increased susceptibility to fracture.

Evaluation of Fatigue Fracture Life for TiN Coated Abutment Screw in Dental Implant

  • Choe, Han-Cheol;Chung, Chae-Heon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.115-116
    • /
    • 2012
  • In this study, fitness and fatigue test were performed to estimate the coating effects of abutment screw for implant system after fatigue test. The purpose of this study was to investigate fatigue fracture phenomena of dental implant fixture used titanium nitride coated abutment screw under cyclic load.

  • PDF