• 제목/요약/키워드: Implant fracture

검색결과 312건 처리시간 0.03초

Prognostic Factors of Orbital Fractures with Muscle Incarceration

  • Lee, Seung Chan;Park, Seung-Ha;Han, Seung-Kyu;Yoon, Eul-Sik;Dhong, Eun-Sang;Jung, Sung-Ho;You, Hi-Jin;Kim, Deok-Woo
    • Archives of Plastic Surgery
    • /
    • 제44권5호
    • /
    • pp.407-412
    • /
    • 2017
  • Background Among the various signs and symptoms of orbital fractures, certain clinical findings warrant immediate surgical exploration, including gaze restriction, computed tomographic (CT) evidence of entrapment, and prolonged oculocardiac reflex. Despite proper surgical reconstruction, prolonged complications such as diplopia and gaze restriction can occur. This article evaluated the prognostic factors associated with prolonged complications of orbital fractures with muscle incarceration. Methods The medical records of 37 patients (37 orbits) with an orbital fracture with muscle incarceration from January 2001 to January 2015 were reviewed. The presence of Incarcerated muscle was confirmed via CT, as well as by intraoperative findings. Various factors potentially contributing to complications lasting for over 1 year after the injury were categorized and analyzed, including age, cause of injury, injury-to-operation time, operative time, fracture type, nausea, vomiting and other concomitant symptoms and injuries. Results All patients who presented with extraocular muscle limitations, positive CT findings, and/or a positive forced duction test underwent surgery. Of the 37 patients, 9 (24%) exhibited lasting complications, such as diplopia and gaze restriction. The mean follow-up period was 18.4 months (range, 1-108 months), while that of patients who experienced prolonged complications was 30.1 months (range, 13-36 months). Two factors were significantly associated with prolonged complications: injury-to-operation time and nausea/vomiting. Loss of vision, worsening of motility, and implant complication did not occur. Conclusions Patients who present with gaze limitations, with or without other signs of a blow-out fracture, require a thorough evaluation and emergent surgery. A better prognosis is expected with a shorter injury-to-operation time and lack of nausea and vomiting at the initial presentation.

완전무치악 환자에서 고정성 임플란트 하이브리드 수복물의 임상성적 (Clinical outcomes of implant supported fixed-hybrid prostheses in the fully edentulous arches)

  • 허윤혁;이양진;권민정;김영균;차민상
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.183-189
    • /
    • 2013
  • 연구 목적: 이 연구의 목적은 완전무치악 환자에서 임플란트 지지 고정성 하이브리드 수복물로 수복한 환자의 임상성적을 알아보는 것이다. 연구 대상 및 방법: 분당서울대병원에서 2003년 10월부터 2009년 11월 사이에 4-6개의 임플란트 지지 고정성 하이브리드 수복물로 수복을 하고 1년 이상 기능한 환자를 대상으로 하였다. 방사선 사진상에서 변연골 흡수량을 측정하고 성별, 해부학적 위치(상악 대 하악), 대합치, 하중시기, 식립 경사도에 따른 차이를 비모수 검정(Mann-Whitney U test) 하고, 외팔보의 길이에 따른 영향을 회귀분석하였으며 합병증을 조사하였다. 유의 수준P<.05로 검정하였다. 결과: 총 16명, 16개 수복물에서 84개의 임플란트의 평균 28개월 후의 골흡수량은 $0.53{\pm}0.39mm$였다. 환자의 성별, 해부학적 위치(상악 대 하악), 대합치, 하중시기에 따른 골흡수량의 유의차는 관찰되지 않았으며(P>.05) 회귀분석 결과 외팔보의 길이와 외팔보 인접 최후방 임플란트의 골흡수량 사이에도 유의성이 없었다(P>.05). 16명중11명의 환자에서 합병증이 발생하였으며 전장재 파절과 인공치 탈락이 가장 많았다. 결론: 짧은 기간의 후향적 연구라는 한계 내에서, 임플란트 지지 고정성 하이브리드 수복물의 평균 골흡수는 매우 적었지만 높은 빈도의 합병증 발생을 보였다. 외팔보 인접 최후방 임플란트의 경사와 관계 없이 외팔보 인접 최후방 임플란트보다 나머지 전방부 임플란트의 변연골 흡수량이 유의하게 컸다. 모든 증례의 외팔보 길이(< 17 mm)는 외팔보 인접 최후방 임플란트 변연골 흡수량에 영향을 주지 않았다.

다발성 안면 골절의 정복 후 발생한 부정교합 상태의 환자를 중심위에서 선택적 교합 조정 및 임플란트 보철수복으로 교합관계를 회복시킨 증례 (Occlusal rehabilitation of post-traumatic malocclusion patient after reduction of panfacial fracture, using selective occlusal adjustment and implant prostheses on centric relation: a case report)

  • 김대균;박소영;이정진;박연희;김경아;서재민
    • 구강회복응용과학지
    • /
    • 제39권4호
    • /
    • pp.204-213
    • /
    • 2023
  • 구강 악안면 영역에서 외상으로 인해 발생한 골절에 대한 치료로 관혈적 혹은 비관혈적인 골절의 정복을 시행할 수 있다. 그러나, 최적의 정복이 이루어지지 않았거나 부정 유합이 발생할 경우, 하악골과 중안모 간의 구조적 관계가 상실되어 부정교합이 일어날 수 있다. 이러한 부정교합은 외상 후 부정교합이라 정의되며 안정적인 턱관절 위치의 확보 후 악교정 수술, 교정치료, 교합 재형성 및 보철적 재건 등이 외상 후 부정교합의 치료방법으로 제시되고 있다. 안정적인 턱관절은 교합 회복 전 부정교합의 재발 및 교합 변화를 방지하기 위해 필수적이며, 중심위 및 적응된 중심위는 가장 안정적인 턱관절의 위치로 교합 회복의 시작점이다. 본 증례는 다발성 안면 골절의 정복 후, 외상 후 부정교합이 발생하여 전악 교합의 회복을 위해 중심위에서 선택적 교합 조정 및 임플란트 지지 고정성 보철물로 보철적 재건을 시행한 증례로 교합 기능적으로 양호한 결과를 얻었기에 이를 보고하고자 한다.

지르코니아/알루미나 복합 지대주의 생물학적 안정성에 관한 연구 (Biological stability of Zirconia/Alumina composite ceramic Implant abutment)

  • 배규현;한증석;김태일;설양조;이용무;구영;조기영;정종평;한수부;류인철
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.555-565
    • /
    • 2006
  • The purpose of the present study is to evaluate the biological stability of the zirconia/alumina composite abutment by histologic and radiographic examination in clinical cases. 17 partially edentulous patients (5 men and 12 women, mean age 47) were treated with 37 implants. The implants were placed following the standard two-stage protocol. After a healing period of 3 to 6 months, zirconia/alumina composite abutments were connected. All radiographs were taken using paralleling technique with individually fabricated impression bite block, following insertion of the prosthesis and at the 3-, 6-, 12 month re-examinations. After processing the obtained images, the osseous level was calculated using the digital image in the mesial and distal aspect in each implant. An ANOVA and t-test were used to test for difference between the baseline and 3-, 6-, 12 months re-examinations, and for difference between maxilla and mandible. Differences at P <0.05 were considered statistically significant. For histologic examination, sample was obtained from the palatal gingiva which implant functioned for 12 months. Sections were examined under a light microscope under various magnifications. Clinically, no abutment fracture or crack as well as periimplantitis was observed during the period of study. The mean bone level reduction(${\pm}standard$ deviation) was 0.34 rom(${\pm}\;0.26$) at 3-months, 0.4 2mm(${\pm}\;0.30$) at 6-months, 0.62 mm(${\pm}\;0.28$) at 12-months respectively. No statistically significant difference was found between baseline and 3-, 6-, 12-months re-examinations (p > 0.05). The mean bone level reduction in maxilla was 0.33(${\pm}0.25$) at 3-months, 0.36(${\pm}0.33$) at 6-months, 0.56(${\pm}0.26$) at 12-months. And the mean bone level reduction in mandible was 0.35(${\pm}0.27$) at 3-months, 0,49(${\pm}0.27$) at 6-months, 0.68(${\pm}0.30$) at 12-months. No statistical difference in bone level reduction between implants placed in the maxilla and mandible. Histologically, the height of the junctional epithelium was about 2.09 mm. And the width was about 0.51 mm. Scattered fibroblasts and inflammatory cells, and dense collagen network with few vascular structures characterized the portion of connective tissue. The inflammatory cell infiltration was observed just beneath the apical end of junctional epithelium and the area of direct in contact with zirconia/alumina abutment. These results suggest the zirconia/alumina composite abutment can be used in variable intraoral condition, in posterior segment as well as anterior segment without adverse effects.

Changes In Mechanical Strength of Compression HIP Screws in Relation to Design Variations - A Biomechanical Analysis

  • Moon S. J.;Lee H. S.;Jun S. C.;Jung T. G.;Ahn S. Y.;Lee H.;Lee S. J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권2호
    • /
    • pp.123-127
    • /
    • 2005
  • Compression Hip Screw (CHS) is one of the most widely-used prostheses for the treatment of intertrochanteric fractures because of its strong fixation capability. Fractures at the neck and screw holes are frequently noted as some of its clinical drawbacks, which warrant more in-depth biomechanical analysis on its design variables. The purpose of this study was to evaluate changes in the strength with respect to the changes in design such as the plate thickness and the number of screw holes. Both mechanical test and FEM analysis were used to systematically investigate the sensitivities of the above-mentioned design variables. For the first part of the mechanical test, CHS (n=20) were tested until failure. The CHS specimens were classified into four groups: Group Ⅰ was the control group with the neck thickness of 6-㎜ and 5 screw holes on the side plate, Group Ⅱ 6-㎜ thick and 8 holes, Group Ⅲ 7.5-㎜ thick and 5 holes, and Group Ⅳ 7.5-㎜ thick and 8 holes. Then, the fatigue test was done for each group by imparting 50% and 75% of the failure loads for one million cycles. For the FEM analysis, FE models were made for each group. Appropriate loading and boundary conditions were applied based on the failure test results. Stresses were assessed. Mechanical test results indicated that the failure strength increased dramatically by 80% with thicker plate. However, the strength remained unchanged or decreased slightly despite the increase in number of holes. These results indicated the higher sensitivity of plate thickness to the implant strength. No fatigue failures were observed which suggested the implant could withstand at least one million cycles of fatigue load regardless of the design changes. Our FEM results also supported the above results by showing a similar trend in stress as those of mechanical test. In summary, our biomechanical results were able to show that plate thickness could be a more important variable in design for reinforcing the strength of CHS than the number of screw holes.

용접방법에 의한 타이타늄 연결부의 기계적 성질에 관한 연구 (MECHANICAL PROPERTIES OF TITANIUM CONNECTORS TREATED BY VARIOUS WELDING TECHNIQUES)

  • 이수영;장익태;허성주;임순호
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.545-566
    • /
    • 1999
  • The use of pure titanium and titanium alloys have been increased recently in fixed, removable prosthodontics and implant fields as a framework. But when they were used for superstructures of implant or metal framework of removable prosthesis, welding is necessary to reconnect the fracture site to control the casting distortions. To overcome the difficulties in soldering the titanium due to high oxidation property, much effort have been devoted. In this study, some of mechanical properties were compared between pure titanium and Ti-6Al-4V alloy by using after welding, electron beam welding technique and tungsten arc welding. Mechanical properties such as tensile strength, yield strength, elongation and microhardness were measured. And, in order to compare the effect of welding site and surrounding metal tissue according to the welding condition, SEM photographs were taken and element distribution was observed by Wave Dispersion Spectroscopy. Through analyses of the data, following results were obtained; 1. In items such as tensile strength, yield strength and elongation according to the welding techniques of pure titanium, only tungsten arc welded group showed significant lower value than other groups(P<0.05). 2. In items such as tensile strength and yield strength according to the welding techniques of Ti-6Al-4V alloy, control group and tungsten arc welded group showed significant difference among all the groups(P<0.05). 3. Ti-6Al-4V alloy exhibited significantly greater elongation than control group when the laser welding method and electron beam welding method were used, and elongation showed increasing tendency. 4. Pure titanium specimens exhibited increasing tendency of microhardness regardless of the weld-ing technique applied, and especially tungsten arc welded group demonstrated a great increase of microhardness than parent metal. 5. There was no hardness change in laser welded group and electron beam welded group of Ti-6Al-4V alloy, but in tungsten arc welded group, hardness changed greatly from parent metal to weld seam. 6. Through the metallographic examination and scanning electron microscopy, laser welding caused central fusion and recristallizations were formed and tungsten arc welding caused localized fusion to 0.3-0.7mm from the surface.

  • PDF

Grooved abutment가 임플란트 지대주 연결나사의 안정성에 미치는 영향 (Effects of grooved abutment on stability of implant abutment screw)

  • 심일광;양승원;심준성;김지환
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.387-392
    • /
    • 2016
  • 목적: 본 연구의 목적은 grooved abutment가 지대주 나사풀림 현상에 미치는 영향을 확인하는 것이다. 재료 및 방법: 2015년 3월부터 7월까지 연세대학교 치과대학병원 보철과에 내원한 50명, 51개 임플란트에 대해서 임플란트 보철 장착 후 6개월 점검 시 지대주 연결나사의 안정성을 평가하였다. 대조군은 groove가 없는 지대주를 사용한 30개 임플란트이었고, 실험군은 groove가 있는 지대주를 사용한 21개 임플란트이었으며, Astra, Straumann, Implantium, Osstem 시스템이 사용되었다. 6개월 점검 시에 지대주 연결나사의 풀림여부를 조사하였고, 동일한 힘으로 재체결 시 지대주 연결나사의 추가 회전각을 측정하였으며, 보철물 협측하방 부위에서 PTV를 측정하였다. SPSS 프로그램을 이용하여 정규성 분석 후 Mann-Whitney 분석을 시행하였다. 결과: 51개 임플란트에 대해 보철 장착 후 6개월 점검을 시행한 바, 나사 풀림이나 보철물 파절 등의 특이할 만한 합병증은 나타나지 않았다. 6개월 후 지대주 연결나사의 추가회전각은, 실험군 평균은 $4.75^{\circ}$이었고 대조군 평균은 $7.35^{\circ}$이었으며, 통계적으로 유의한 차이는 없었다 (P = .576). PTV에서도 유의한 차이는 없었다 (P = .767). 결론: 지대주의 groove 여부가 지대주 연결나사의 안정성에 미치는 영향은 유의한 차이가 없으나, 이에 대해 좀더 장기적이고 다수의 증례를 이용한 추가적인 연구가 필요해 보인다.

전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례 (Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system)

  • 양민수;방몽숙;박상원;임현필;윤귀덕;양홍서
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.33-38
    • /
    • 2013
  • 교합평면은 시상면적인 치열궁 형태를 나타내는 것으로, 악구강계를 구성하는 요소의 하나인 교합을 형태적으로 구성한다. 본 증례에서는 생체의 정중 시상면에 대한 수평, 측방좌표를 교합기상에 재현하여 상하악 치아 및 결손부 치조제에 대한 좌우 동적인 위치관계 얻기 위해 Shilla system (Hamans, Tokyo, Japan)을 이용하여 교합평면을 재구성 하였다. 본 증례의 환자는 41세의 남자 환자로 상악 전치부 10본금속-도재 고정성국소의치 파절 및 탈락과 전반적인 치료를 주소로 내원하였다. 임상 검사, 방사선 검사, 모형분석을 통해 임플란트 식립을 동반한 완전구강회복술을 하기로 결정하였다. Gothic Arch device (Centrofix; AmannGirrbach GmbH, Germany)를 이용하여 악간관계를 채득하고 마운팅 후, Shilla system을 이용하여 기존 교합평면을 평가, 분석하여 진단 납형을 제작하였다. 이를 토대로 방사선 스텐트를 제작하여 임플란트 식립하였고, 진단 납형을 이용하여 임시수복물을 제작하였다. 임시 수복물의 형태 및 교합 양식을 재현하기 위해 맞춤 전방유도판을 제작하고, 교차 마운팅을 시행하였으며 최종 수복물은 지르코니아 코핑을 이용한 완전 도재관으로 제작하였다. 이상과 같이 전악수복환자에서 진단과 치료 과정에서 Shilla system을 이용하여 적절한 심미적, 기능적 수복 결과를 얻을 수 있었다.

임플란트 나사에 적용되는 생역학적 원리: 문헌고찰 (Biomechanical considerations for the screw of implant prosthesis: A literature review)

  • 임소민;김대곤;박찬진;차민상;조리라
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.61-68
    • /
    • 2010
  • 연구 목적: 임플란트 보철물의 유지 나사에 적용되는 전하중은 나사를 조임으로써 임플란트와 지대주 사이에 인장력이 발생하면서 나사가 신장되는 힘을 말한다. 이 연구는 전하중에 영향을 미치는 생역학적 요인들과 나사 풀림에 기여하는 다양한 요인에 대하여 문헌을 고찰하고자 하였다. 연구 재료 및 방법: 1981년부터 2009년까지 발표된 나사 풀림을 다룬 임상연구 중 설정한 기준에 합당한 문헌을 요약하여 나사 풀림의 빈도를 밝혔고 나사의 안정성과 전하중에 관한 생역학을 다룬 문헌을 조사하고 요약하였다. 또한, 본 교실에서 연구한 실험실적 결과도 포함시켰다. 결과 및 결론: 나사 풀림의 정도는 나사에 토크를 가하는 기술이 발달함에 따라 현저히 감소하고 있다. 그 외에도 나사의 재질, 마찰계수를 감소시키기 위한 피복 기술의 발달 및 나사산의 모양 등 전하중에 영향을 줄 수 있는 요인을 고찰하였다. 전하중이 일정 수준 이하로 떨어지게 되면 나사의 움직임이 발생하게 되는데 이는 장기적으로 축적되어 피로파절 및 응착 마모, 소성 변형 등을 유발하게 되므로 주의해야 한다. 최적의 전하중을 주기 위해서는 토크 렌치를 이용하고 환자의 재내원시 다시 토크를 가하는 방법 등이 추천된다.

The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

  • Choi, Won Chul;Choi, Hyun Gon;Kim, Jee Nam;Lee, Myung Cheol;Shin, Dong Hyeok;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • 대한두개안면성형외과학회지
    • /
    • 제17권3호
    • /
    • pp.135-139
    • /
    • 2016
  • Background: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant removal has been developed in the last decade. The purpose of this study is to share the experience of authors and to demonstrate the efficacy of bioabsorbable mesh in a variety of craniofacial trauma operations. Methods: Between October 2008 and February 2015, bioabsorbable meshes were used to reconstruct various types of craniofacial bone fractures in 611 patients. Any displaced bone fragments were detached from the fracture site and fixed to the mesh. The resulting bone-mesh complex was designed and molded into an appropriate shape by the immersion in warm saline. The mesh was molded once again under simultaneous warm saline irrigation and suction. Results: In all patients, contour deformities were restored completely, and bone segments were fixed properly. The authors found that the bioabsorbable mesh provided rigid fixation without any evidence of integrity loss on postoperative computed tomography scans. Conclusion: Because bioabsorbable meshes are more flexible than bioabsorbable plates, they can be molded and could easily reconstruct the facial bone in three dimensions. Additionally, it is easy to attach bone fragments to the mesh. Bioabsorbable mesh and screws is effective and can be easily applied for fixation in various craniofacial trauma reconstructive scenarios.