• Title/Summary/Keyword: Implant fracture

Search Result 312, Processing Time 0.029 seconds

Reconstruction of extended orbital floor fracture using an implantation method of gamma-shaped porous polyethylene

  • Hwang, Woosuk;Kim, Jin Woo
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.3
    • /
    • pp.164-169
    • /
    • 2019
  • Background: The conventional surgical method for reconstructing orbital floor fractures involves restoration of orbital continuity by covering an onlay with a thin material under the periorbital region. However, in large orbital floor fractures, the implant after inserting is often dislocated, leading to malposition. This study aimed to propose a novel implanting method and compare it with existing methods. Methods: Among patients who underwent surgery for large orbital floor fractures, 24 who underwent the conventional onlay implanting method were compared with 21 who underwent the novel ${\gamma}$ implanting method that two implant sheets were stacked and bent to resemble the shape of the Greek alphabet ${\gamma}$. When inserting a ${\gamma}$-shaped implant, the posterior ledge of the orbital floor was placed between the two sheets and the bottom sheet was impacted onto the posterior wall of the maxilla to play a fixative role while the top sheet was placed above the residual orbital floor to support orbital contents. Wilcoxon signed-rank test and Mann-Whitney U test were used for data analyses. Results: Compared to the conventional onlay method, the gamma method resulted in better restoration of orbital contents, better improvement of enophthalmos, and fewer revision surgeries. Conclusion: Achieving good surgical outcomes for extended orbital floor fractures is known to be difficult. However, better surgical outcomes could be obtained by using the novel implantation method of impacting a ${\gamma}$-shaped porous polyethylene posteriorly.

Two Portal Approach(Endoscopic Transnasal and Subciliary) in Medial Orbital Wall Fracture (내시경을 이용한 비강내 접근법과 속눈썹밑 절개를 동시에 이용한 안와내벽 재건술)

  • Chang, Hyun;Dhong, Eun-Sang;Won, Chang-Hoon;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.552-556
    • /
    • 2006
  • Purpose: As the use of computed tomographic scanning spread, the diagnosis of blow-out fractures of the medial orbital wall increased. Conventionally, the surgery of blow-out fractures in medial orbital wall was performed by various approaches with external incision or endoscopic approach. Although the field of orbital surgery has progressed significantly during the last decade, accurate realignment and replacement of component is difficult due to lack of visualization of the fracture site, blind dissection of the orbital wall, and difficulty in insertion of implant. In order to overcome these shortcomings, we explored the use of endoscopic transnasal approach together with subciliary approach. Methods: The entrapped periorbital tissues in the ethmoid sinus were completely reduced endoscopically, and the bone defect of medial orbital wall was reconstructed with $Medpor^{(R)}$ insertion via subciliary approach. This technique was applied to 13 patients who had medial orbital wall fracture. Results: The patients were followed-up for 3 to 24 months with an average of 9 months. The postoperative courses were satisfactory in all cases. Conclusion: The conjunction of endoscopic transnasal and subciliary approach technique seems to produce good results in medial orbital wall fracture.

Surgical Treatment of Olecranon Fractures

  • Koh, Kyoung-Hwan;Oh, Hyoung-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.49-56
    • /
    • 2017
  • Since the olecranon fractures are caused by relatively low-energy injuries, such as a fall from standing height, they are usually found without comminution. Less commonly they can be developed by high-energy injuries and have severe concomitant comminution or injuries to surrounding structures of the elbow. Because the fracture by nature is intra-articular with the exception of some avulsion-type fracture, a majority of olecranon fractures are usually indicated for surgical treatment. Even if there is minimal displacement, surgical treatment is recommended because there is a possibility of further displacement by the traction force of triceps tendon. The most common type of olecranon fracture is displaced, simple non-comminuted fracture (that is, Mayo type IIA fractures). Although tension band wiring was the most widespread treatment method for these fractures previously, there is some trends toward fixation using locking plates. Primary goal of the surgery is to restore a congruent joint and extensor mechanisms by accurate reduction and stable fixation so that range of motion exercises can be performed. The literature has shown that good clinical outcomes are achieved irrespective of surgical fixation technique. However, since the soft tissue envelope around the elbow is poor and the implants are located at the subcutaneous layer, implant irritation is still the most common complication associated with surgical treatment.

A useful additional medial subbrow approach for the treatment of medial orbital wall fracture with subciliary technique

  • Kim, Seung Min;Kim, Cheol Keun;Jo, Dong In;Lee, Myung Chul;Kim, Ji Nam;Choi, Hyun Gon;Shin, Dong Hyeok;Kim, Soon Heum
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.2
    • /
    • pp.101-108
    • /
    • 2019
  • Background: To date, a variety of surgical approaches have been used to reconstruct the medial orbital wall fracture. Still however, there is still a controversy as to their applicability because of postoperative scars, injury of anatomical structures and limited visual fields. The purpose of this study was to introduce a useful additional medial subbrow approach for better reduction and securement more accurate implant pocket of medial orbital wall fracture with the subciliary technique. Methods: We had performed our technique for a total of 14 patients with medial orbital wall fracture at our medical institution between January 2016 and July 2017. All fractures were operated through subciliary technique combined with the additional medial subbrow approach. They underwent subciliary approach accompanied by medial wall dissection using a Louisville elevator through the slit incision of the medial subbrow procedure. This facilitated visualization of the medial wall fracture site and helped to ensure a more accurate pocket for implant insertion. Results: Postoperative outcomes showed sufficient coverage without displacement. Twelve cases of preoperative diplopia improved to two cases of postoperative diplopia. More than 2 mm enophthalmos was 14 cases preoperatively, improving to 0 case postoperatively. Without damage such as major vessels or extraocular muscles, enophthalmos was corrected and there was no restriction of eyeball motion. Conclusion: Our ancillary procedure was useful in dissecting the medial wall, and it was a safe method as to cause no significant complications in our clinical series. Also, there is an only nonvisible postoperative scar. Therefore, it is a recommendable surgical modality for medial orbital wall fracture.

Metallic Radial Head Prosthesis in Korea (요골두 금속 치환물의 국내 사용)

  • Han, Sang-Hwan;Moon, Jun-Gyu;Park, Jong-Wong;Jang, Ki-Mo
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.84-91
    • /
    • 2007
  • Purpose: The aim of this study was to report seven cases of metallic radial head prosthesis and present the limit of use in Korea. Materials and Methods: Metallic radial head arthroplasty was performed on 7 patients between April 2006 and December 2006, who had complex elbow injury including comminuted radial head fracture. Indication, operative findings and outcome were assessed. Availability and payment of implant were investigated. Results: All of the patients had more than one associated injury including coronoid fracture, olecranoan fracture, and ligament ruptures. According to Mason classification, there were three type III and four type IV fractures. All radial head fractures were too comminuted to reconstruct. There were two excellent results, four good, and one poor, as graded by Mayo score. There were no patient with instability and implant related complications. Insufficient supply of implant did not enable to do scheduled surgery in 2 cases. Current medical insurance did not cover charge for radial prosthesis, five patients could not help paying for that by themselves. Conclusion: Metallic radial head implants are useful when the radial head cannot be repaired reliably. Preoperative preparing and coverage by medical insurance based on appropriate indication are helpful for decision for a treatment option.

Survival analysis of dental implants in maxillary and mandibular molar regions; A 4$\sim$5 year report ($\cdot$하악 대구치 부위에 식립된 임플란트의 생존율에 대한 후향적 연구)

  • Jang, Jin-Wha;Ryoo, Gyeong-Ho;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.165-180
    • /
    • 2007
  • Dental Implants have been proved to be successful prosthetic modality in edentulous patients for 10 years. However, there are few reports on the survival of implant according to location in molar regions. The purpose of this study was to evaluate the $4{\sim}5$ years' cumulative survival rate and the cause of failure of dental implants in different locations for maxillary and mandibular molars. Among the implants placed in molar regions in Gwangju Mir Dental Hospital from Jan. 2001 to Jun. 2002, 473 implants from 166 patients(age range; $26{\sim}75$) were followed and evaluated retrospectively for the causes of failure. We included 417 implants in 126 periodontally compromised patients, 56 implants in 40 periodontal healthy patients, and 205 maxillary and 268 mandibular molar implants. Implant survival rates by various subject factors, surgical factors, fixture factors, and prosthetic factors at each location were compared using Chi-square test and Kaplan-Meier cumulative survival analysis was done for follow-up(FU) periods. The overall failure rate at 5 years was 1O.2%(subject level) and 5.5%(implant level). The overall survival rates of implants during the FU periods were 94.5% with 91.3% in maxillary first molar, 91.1% in maxillary second molar, 99.2% in mandibular first molar and 94,8% in mandibular second molar regions. The survival rates differed significantly between both jaws and among different implant locations(p<0.05), whereas the survival rates of functionally loaded implants were similar in different locations. The survival rates were not different according to gender, age, previous periodontal status, surgery stage, bone graft type, or the prosthetic type. The overall survival rate was low in dental implant of too wide diameter(${\geq}5.75$ mm) and the survival rate was significantly lower for wider implant diameter(p

Evaluation of the Availability of Implant placement using Ridge Expansion Osteotomy (REO) (치조능확장골절단술을 이용한 임프란트 식립술의 유용성 평가)

  • Kim, Yeong-Gyun;Yun, Pil-Yeong;Kim, Beom-Su
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.243-247
    • /
    • 2008
  • Purpose : Ridge expansion osteotomy (REO) has been introduced when it is necessary to expand narrow crestal ridge with simultaneous implant placement. This study has designed to evaluate the clinical availability of REO. Materials and methods : Subject were patients who had visited Seoul National University Bundang Hospital from July. 2003 to December, 2005 for implant placement using REO by one surgeon. Intraoperative and postoperative complication, failure of initial osseointegration and marginal bone resorption were estimated using electronic medical record and periapical radiography. Twenty?three patients, 8 males and 15 females, mean age 51, ranged 18 to 72, were treated for mean 26 months, ranged from 16 months to 46 months. Results : Mean diameter and length of implants placed at upper anterior, were 3.72mm and 13.32mm each other. Guided bone regeneration and ridge splitting were accompanied in this study. Five cases of cortical bone fracture, three cases of crestal bone loss more than 2mm, 2cases of gingival recession, and 2 cases of infection were noted, but there were no implants removed because of disintegration. Success rate of implant was 91.7%, even if survival rate of implant was 100%. In addition, there were no statistical significance between the success rate of REO and bone graft(p>0.05). Conclusion : Based on the results of the present study, it can be concluded that REO technique is reliable for implant placement at atrophic ridge with adequate height compared to bone graft and other osteotomies for ridge expansion, but care should be taken of esthetic problem such as gingival recession because of crestal bone resorption from trauma by osteotome.

  • PDF

Three dimensional finite element analysis of the stress on supporting bone by the abutment materials of dental implant (치과용 임플란트 지대주 재료에 따른 지지골 응력의 3차원 유한요소 분석)

  • Lee, Myung-Kon;Kim, Kap-Jin
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.41-47
    • /
    • 2018
  • Purpose: The purpose of this study was to analyze the biomechanical properties of the dental implants on the supporting bone using three-dimensional finite element method when three different abutment materials were applied to the implant system. Methods: Three different dental implant models were fabricated by applying Ti, PEEK, and CRE-PEEK (60% carbon-reinforced PEEK) to abutment material. The abutment and connecting screw from the fixture was applied with a tightening torque of 20 Ncm. And then, total loads of 150 N were applied in an $30^{\circ}oblique$ direction (to the vertical). The structural stability of dental implants on the supporting bone was analyzed using Von Mises stress and principal stress values. Results: The maximum tensile stress of the cortical bone was highest at 12.6 MPa in the PEEK abutment (Model-B). Ti abutment (Model-A) and CRE-PEEK abutment (Model-C) showed similar stress distributions (10.6 and 10.3 MPa, respectively). And the maximum compressive principal stress was similar in all models. The Von Mises stress value delivered to the bone around the implant was highest at 16.5 MPa in Model-B. On the other hand, Model-A and C showed similar stress distributions (14.0 and 13.8 MPa, respectively). In addition, the maximum equivalent stress applied to the abutment was highest at 629.8 MPa in Model-A. The stress distribution in Model-C was 573.9 MPa. Whereas, Model-B showed the lowest value at 165.6 MPa. Conclusion : The dental implant supporting bone system using PEEK material seems to have the possibility of supporting bone fracture. It was found that the CRE-PEEK abutment can reduce the elastic deformation and reduce the stress value of the interfacial bone.

The biocompatibility and mechanical properties of plasma sprayed zirconia coated abutment

  • Huang, Zhengfei;Wang, Zhifeng;Yin, Kaifeng;Li, Chuanhua;Guo, Meihua;Lan, Jing
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.157-166
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the clinical performance and reliability of plasma sprayed nanostructured zirconia (NSZ) coating. MATERIALS AND METHODS. This study consisted of three areas of analysis: (1) Mechanical property: surface roughness of NSZ coating and bond strength between NSZ coating and titanium specimens were measured, and the microstructure of bonding interface was also observed by scanning election microscope (SEM). (2) Biocompatibility: hemolysis tests, cell proliferation tests, and rat subcutaneous implant test were conducted to evaluate the biocompatibility of NSZ coating. (3) Mechanical compatibility: fracture and artificial aging tests were performed to measure the mechanical compatibility of NSZ-coated titanium abutments. RESULTS. In the mechanical study, 400 ㎛ thick NSZ coatings had the highest bond strength (71.22 ± 1.02 MPa), and a compact transition layer could be observed. In addition, NSZ coating showed excellent biocompatibility in both hemolysis tests and cell proliferation tests. In subcutaneous implant test, NSZ-coated plates showed similar inflammation elimination and fibrous tissue formation processes with that of titanium specimens. Regarding fatigue tests, all NSZ-coated abutments survived in the five-year fatigue test and showed sufficient fracture strength (407.65-663.7 N) for incisor teeth. CONCLUSION. In this study, the plasmasprayed NSZ-coated titanium abutments presented sufficient fracture strength and biocompatibility, and it was demonstrated that plasma spray was a reliable method to prepare high-quality zirconia coating.

Limited eye movement caused by clumping of fibrin glue used in blowout fracture surgery: a care report

  • Shin, Jin Yong;Lee, Nae-Ho;Kim, Min-Seok;Roh, Si-Gyun;Chung, Yoon Kyu
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.228-231
    • /
    • 2022
  • Fibrin glue is a topical agent widely used for hemostasis, wound healing, and surgical adhesion. Complications of fibrin glue itself are extremely rare because it is absorbed over time, but can occur as a result of inappropriate application. We report a case of a postoperative complication caused by inappropriate application of fibrin glue in blow-out fracture surgery. A 65-year-old male patient presented with periorbital swelling and an open wound on the right infraorbital area. Computed tomography showed a right orbital floor fracture. After reduction of the herniated tissue into the orbit, an implant was inserted and fibrin glue was applied to stabilize the implant. This procedure was performed without difficulty, but the patient complained of persistent diplopia and limited eyeball movement after surgery. An imaging study showed a mass-like lesion, which was not a hematoma, in the orbital cavity. In a second operation, the mass was identified as clotted fibrin glue that had not been applied properly. After removal, the patient's symptoms were relieved without further complications. Appropriate and careful application of fibrin glue is necessary to avoid unnecessary complications.