• 제목/요약/키워드: Implant fracture

검색결과 320건 처리시간 0.031초

Combination of metal artifact reduction and sharpening filter application for horizontal root fracture diagnosis in teeth adjacent to a zirconia implant

  • Debora Costa Ruiz;Larissa de Oliveira Reis;Rocharles Cavalcante Fontenele;Murilo Miranda-Viana;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • 제54권3호
    • /
    • pp.289-295
    • /
    • 2024
  • Purpose: This study examined the influence of metal artifact reduction (MAR), the application of sharpening filters, and their combination on the diagnosis of horizontal root fracture (HRF) in teeth adjacent to a zirconia implant on cone-beam computed tomography (CBCT) examinations. Materials and Methods: Nineteen single-rooted teeth (9 with HRF and 10 without) were individually positioned in the right central incisor socket of a dry human maxilla. A zirconia implant was placed adjacent to each tooth. Imaging was performed using an OP300 Maxio CBCT (Instrumentarium, Tuusula, Finland) unit with the following settings: a current of 8 mA, both MAR modes(enabled and disabled), a 5×5 cm field of view, a voxel size of 0.085 mm, and a peak kilovoltage of 90 kVp. Four oral and maxillofacial radiologists independently evaluated the CBCT scans under both MAR conditions and across 3 levels of sharpening filter application (none, Sharpen 1×, and Sharpen 2×). Diagnostic metrics were calculated and compared using 2-way analysis of variance (α=5%). The weighted kappa test was used to assess intra- and inter-examiner reliability in the diagnosis of HRF. Results: MAR tool activation, sharpening filter use, and their combination did not significantly impact the area under the receiver operating characteristic curve, sensitivity, or specificity of HRF diagnosis (P>0.05). Intra- and inter-examiner agreement ranged from fair to substantial. Conclusion: The diagnosis of HRF in a tooth adjacent to a zirconia implant is not affected by the activation of MAR, the application of a sharpening filter, or the combination of these tools.

Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation (견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술)

  • Ko, Sang-Hun
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Stability of implant screw joint (임플란트 나사의 안정성)

  • Chung, Chae-Heon;Kwak, Jong-Ha;Jang, Doo-IK
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제19권2호
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Simultaneous Implant Placement with Modified Ridge Splitting/Expansion Technique in the Narrow Edentulous Alveolar Ridge : 3 Cases Report (좁은 치조골에 변형된 치조능 분할술/확장술을 이용한 임플란트 동시 식립 : 3 가지 증례보고)

  • Lee, Jong-Bin;Lee, Jae-Hong;Kim, Young-Taek
    • The Journal of the Korean dental association
    • /
    • 제53권8호
    • /
    • pp.545-557
    • /
    • 2015
  • The modified ridge splitting/expansion technique combined with guided bone regeneration (GBR) for implant surgery is used to expand the narrow and atrophied edentulous alveolar ridge. Also, the simultaneous implant placement after ridge splitting/expansion technique can reduce the treatment and healing time. This case report includes three patients with a narrow edentulous alveolar ridge of the 2 to 4mm. All three patients underwent a fracture of thin buccal cortical bone plate, and these defects were corrected by the use of the guided bone regeneration (GBR). After 7 to 18 months, all surgical area was stable, and all implant showed a good healing state on the clinical and radiographic examination. In conclusion, though this surgical method is technique sensitive, the modified ridge splitting/expansion technique combined with GBR for implant surgery is recommended for a horizontal augmentation in the narrow edentulous alveolar ridge.

Large Intraorbital Cyst after Silicone Implant Insertion: A Case Report (Silicone Implant 삽입 후에 발생한 안와내 거대 낭종)

  • Ha, Sang Wook;Lee, Hye Kyung;Yoo, Won Min;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.659-662
    • /
    • 2006
  • Purpose: Alloplastic implants, such as methylmethacrylate, Teflon, silicone, Supramid are commonly used to cover the floor defect and to prevent reherniation of the displaced orbital tissue in orbital floor fracture. Silicone implant has been used for reconstruction of orbital wall defects because of pliability, advantage of carving and chemically inert nature. However, silicone implant also has complications including infection, extrusion, pain, dystopia and tissue reaction. Cyst formation around the silicone implant is a very rare complication. According to many reports, cysts around alloplastic implant in an orbital area are mostly hemorrhagic cysts consisted of blood breakdown product with fibrous capsule cell in histologic examination. Methods: The authors report atypical case and successful treatment of intraorbital hemorrhagic cyst around silicone implant of a 37-year-old male patient. Results: Preoperative symptoms of diplopia, exophthalmos, proptosis, vertical dystopia and ectropion of lower eyelid were resolved after surgical removal of implants with surrounding capsule. Conclusion: Clinical suspicion of plastic surgeon is important in diagnosis of intraorbital cyst of patients who have history of silicone implantation and computed tomography is the standard tool of diagnosis. During the operation, caution must be taken on delivering the whole capsule of intraorbital cyst along with silicone implant to prevent recurrence of the cyst.

Simultaneous Augmentation Rhinoplasty with Bony Reduction in Nasal Bone Fracture (비골골절 시 골절정복과 동시에 시행된 융비술)

  • Lim, Kwang-Ryeol;Kim Song, Jennifer;Kim, Hyung-Do;Hwang, So-Min;Jung, Yong-Hui;Ahn, Sung-Min
    • Archives of Craniofacial Surgery
    • /
    • 제11권2호
    • /
    • pp.77-84
    • /
    • 2010
  • Purpose: The nasal bones are the most common fracture sites of the facial bones, and a careful reduction may still result in secondary deformities, such as saddle nose, deviated nose, hump nose etc, requiring secondary cosmetic rhinoplasty. Therefore, this study examined the clinical characteristics of nasal bone fractures to propose guidelines for patient selection and surgical procedures to achieve more satisfactory results and to prevent secondary deformities with simultaneous augmentation rhinoplasty and bony reduction. Methods: The study was based on 26 out of 149 nasal bone fracture patients who underwent simultaneous augmentation rhinoplasty with bony reduction between May 2008 and April 2009. Retrospective analysis was performed according to the clinical data, surgical techniques and postoperative results. Results: Of the 26 patients, there were 15 males and 11 females. The incidence according to the Stranc's classification revealed that 62% of patients were injured by a frontal impact and 38% by a lateral impact. Frontal impact plane I (50%) was the most frequent type. At the follow up, 18 (81.2%) out of 22 patients were satisfied with their postoperative outcome, and the remaining 4 patients were fair. No one was dissatisfied. However, 5 cases in 3 patients (23%) had some complications; minimal implant deviation in 2 cases, minor irregularity on the nasal dorsum in 2 cases and palpable implant movement under palpation in 1 case. None of these cases required surgical correction. Conclusion: With the proper guidance, simultaneous augmentation rhinoplasty with bony reduction can prevent secondary deformities and satisfy the cosmetic outcomes.

치조제 분리술을 이용한 임프란트의 식립증례

  • Kim, Mi-Seong;Nam, Ok-Hyeon;Kim, Su-Gwan;Jo, Se-In;Kim, Sik;Kim, Hyeon-Ho;Gwon, Byeong-Gon
    • The Journal of the Korean dental association
    • /
    • 제40권9호통권400호
    • /
    • pp.709-715
    • /
    • 2002
  • Two patients with sufficient vertical bone height but insufficient bone width in the anterior mandibular edentulous area, less than 6mm in the buccolingual aspect, for implant placement were chosen for treatment with a ridge splitting procedure. The surgical technique involving greenstick fracture is described. This ridge splitting procedure could be simple placement of implants into ideal restorable positions in severely atrophic, knife-edged ridges and predictable for narrow edentulous alveolar ridge augmentation associated with implant placement. We experienced two cases to place implant with insufficient bone width in the anterior mandibular edentulous area for overdenture be ridge splitting technique. Thus, we will report two cases and review of the literature.

  • PDF

INFLUENCE OF IMPLANT-ABUTMENT INTERFACE DESIGN, IMPLANT DIAMETER AND PROSTHETIC TABLE WIDTH ON STRENGTH OF IMPLANT-ABUTMENT INTERFACE : THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (임플랜트의 지대주 연결방식, 임플랜트의 직경 및 지대주 연결부위의 직경 차이에 따른 응력분포에 관한 삼차원 유한요소분석)

  • Oh Se-Woong;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제41권4호
    • /
    • pp.393-404
    • /
    • 2003
  • Statement of problem. Higher incidence of prosthetic complications such as screw loosening, screw fracture has been reported for posterior single tooth implant. So, there is ongoing research regarding stability of implant-abutment interface. One of those research is increasing the implant diameter and prosthetic table width to improve joint stability. In another part of this research, internal conical type implant-abutment interface was developed and reported joint strength is higher than traditional external hex interface. Purpose. The purpose of this study is to compare stress distribution in single molar implant between external hex butt joint implant and internal conical joint implant when increasing the implant diameter and prosthetic table width : 4mm diameter, 5mm diameter, 5mm diameter/6mm prosthetic table width. Material and method. Non-linear finite element models were created and the 3-dimensional finite element analysis was performed to see the distribution of stress when 300N static loading was applied to model at $0^{\circ},\;15^{\circ},\;30^{\circ}$ off-axis angle. Results. The following results were obtained : 1. Internal conical joint showed lower tensile stress value than that of external hex butt joint. 2. When off-axis loading was applied, internal conical joint showed more effective stress distribution than external hex butt joint. 3. External hex butt joint showed lower tensile stress value when the implant diameter was increased. 4. Internal conical joint showed lower tensile stress value than external hex butt joint when the implant diameter was increased. 5. Both of these joint mechanism showed lower tensile stress value when the prosthetic table width was increased. Conclusion. Internal conical joint showed more effective stress distribution than external hex joint. Increasing implant diameter showed more effective stress distribution than increasing prosthetic table width.

Application of Lateral Osteotomy in Nasal Bone Fracture (비골 골절에서 외측 비골 절골술의 적용)

  • Lim, Kwang Ryeol;Song, Jennifer K.;Hwang, So Min;Jung, Yong Hui;Cho, Ka Hyung
    • Archives of Craniofacial Surgery
    • /
    • 제13권2호
    • /
    • pp.104-110
    • /
    • 2012
  • Purpose: Who may dare to state that optimal choice of treating nasal bone fracture is closed reduction? Few decades of authors' experience in nasal bone fracture has lead to believe that more active and assertive approach in nasal bone fracture by performing simultaneous lateral osteotomy may be applied in proper indications to acquire more accurate reduction and cosmetically satisfying result. Methods: From May 2008 to October 2009, among 241 nasal bone fracture patients, 20 patients underwent simultaneous lateral osteotomy with nasal bone fracture reduction. Followed by rigid septal correction, nasal cavity is packed to stabilize the fracture segment for safer osteotomy. Through intranasal incision, in selected cases of difficult reduction or for cosmetic purposes, various types of lateral osteotomy was performed corresponding to the fracture anatomy, conditions of the nasal cavity. Postoperative nasal packing was retained for one week and nasal dorsum splint for 3 weeks. Results: Lateral osteotomy was utilized for difficult cases of closed reduction, for correction of wide nose, hump and deviation in 9, 5, 2, and 4 cases, respectively. Patient satisfaction was scaled 90% in satisfaction and moderate in 10% (2 cases), complaining of mild nasal tip deviation. Physicians detected 2 cases of apparent deformity with patient recognition; one patient with mild step deformity at the osteotomy site and the other patient with minimal implant mobility. Conclusion: By accompanying profound understanding of the fracture anatomy, more active and assertive approach in nasal fracture reduction can be coincide with simultaneous lateral osteotomy to reduce the rate of secondary deformity and to obtain more cosmetically satisfying result.

Fixation with Bioabsorbable Polylactide Plate and Screws for the Treatment of the Ankle Fractures (생체 흡수성 판과 나사못을 이용한 족근 관절 골절의 치료)

  • Kwon, Duck-Joo;Lee, Yong-Beom;Shin, Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • 제13권1호
    • /
    • pp.80-84
    • /
    • 2009
  • Purpose: The purpose of this article is to assess the efficacy of a bioabsorbable polylactide (PLA) plate and screw for treating injuries of ankle fractures. Materials and Methods: 24 patients who underwent an open reduction and internal fixation operation for ankle fractures from July 2005 to March 2007 were enrolled into the study. There were 15 men and 9 women. The average age of the patients was 44 years and the average follow-up period was 16 years and two months (16.2 months). All cases were divided into low grade fracture patient (11) who belongs in type A and B of Danis-Weber classification and high grade fracture patient (13) who belongs in type C1, C2 of Danis-Weber classification, and each groups were analyzed by clinical (Meyer score) and radiological finding at the time of their last follow-up evaluation. Results: The clinical results according to Meyer scoring system, showed that all patient with low grade fracture had good to excellent result, but only 54% of patient with high grade fracture had good to excellent result. According to Cedell's radiologic finding, there were 91% cases above fair in low grade fracture. But there were 62% of patient above fair result in high grade fracture, the reduction losses were seen in 38% of patient with high grade fracture. Conclusion: Bioabsorbable PLA plate and screw is good internal fixation device which doesn't have additional operation for removal of implant because of slow absorption within the human body. It showed sufficient strength for acquisition and maintenance of reduction in low grade fracture, but need attention to use because of many cases of reduction loss in high grade fracture. So, it seems to be safe and effective when used in heeling of low grade fracture under considering about type of fracture sufficiently.

  • PDF