• Title/Summary/Keyword: Implant capsular contracture

Search Result 32, Processing Time 0.032 seconds

Augmentation Mammaplasty Using Implants: A Review

  • Takayanagi, Susumu
    • Archives of Plastic Surgery
    • /
    • v.39 no.5
    • /
    • pp.448-451
    • /
    • 2012
  • One of the techniques for augmentation mammaplasty is the procedure using implants. Even though this technique has been used for many years, there are still several controversial issues to be discussed and overcome for patient safety. In this review article, capsular contracture, leak or rupture of the implants, possible systemic disease, relation with breast cancer, and recent problems with Poly Implant Prothese implants are described and discussed.

Case of late hematoma after breast augmentation

  • Kim, Leslie;Castel, Nikki;Parsa, Fereydoun Don
    • Archives of Plastic Surgery
    • /
    • v.45 no.2
    • /
    • pp.177-179
    • /
    • 2018
  • We present a case report of a patient who experienced a late, spontaneous breast hematoma 26 years after primary breast augmentation. Late hematomas are a rare complication of breast augmentation with uncertain etiology. In this case, there was no trauma, calcifications, or implant rupture. We believe the patient's hematoma was secondary to erosion of a capsular vessel due to capsular contracture.

The Effect of Sterile Acellular Dermal Matrix Use on Complication Rates in Implant-Based Immediate Breast Reconstructions

  • Lee, Jun Ho;Park, Youngsoo;Choi, Kyoung Wook;Chung, Kyu-Jin;Kim, Tae Gon;Kim, Yong-Ha
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.523-528
    • /
    • 2016
  • Background The use of acellular dermal matrix (ADM) in implant-based immediate breast reconstruction has been increasing. The current ADMs available for breast reconstruction are offered as aseptic or sterile. No published studies have compared aseptic and sterile ADM in implant-based immediate breast reconstruction. The authors performed a retrospective study to evaluate the outcomes of aseptic versus sterile ADM in implant-based immediate breast reconstruction. Methods Implant-based immediate breast reconstructions with ADM conducted between April 2013 and January 2016 were included. The patients were divided into 2 groups: the aseptic ADM (AlloDerm) group and the sterile ADM (MegaDerm) group. Archived records were reviewed for demographic data and postoperative complication types and frequencies. The complications included were infection, flap necrosis, capsular contracture, seroma, hematoma, and explantation for any cause. Results Twenty patients were reconstructed with aseptic ADM, and 68 patients with sterile ADM. Rates of infection (15.0% vs. 10.3%), flap necrosis (5.0% vs. 7.4%), capsular contracture (20.0% vs. 14.7%), seroma (10.0% vs. 14.7%), hematoma (0% vs. 1.5%), and explantation (10.0% vs. 8.8%) were not significantly different in the 2 groups. Conclusions Sterile ADM did not provide better results regarding infectious complications than aseptic ADM in implant-based immediate breast reconstruction.

Clinical Durability and Deflation of Saline-Filled Breast Implant in Breast Reconstruction (유방재건술에 사용된 식염수 보형물의 임상적 내구성과 누출)

  • Kim, Il-Kug;Lee, Jun-Ho;Kim, Yong-Ha;Kim, Tae-Gon;Lee, Soo-Jung;Kang, Soo-Hwan
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.808-814
    • /
    • 2011
  • Purpose: Despite wide clinical use of breast implants, there is continued concern about the lifespan of these devices. The causes of explantation were infection, deflation of implant and patient's want. The deflation of saline-filled breast implant was related to strength and durability of implant shell. The purpose of this study is to evaluate the clinical durability of saline-filled breast implant through the analysis of duration until deflation occurred, causes, incidence and influencing factors. Methods: Retrospective analyses were conducted on clinical records for 19 cases of deflation of saline-filled breast implant from 201 cases of breast reconstruction with saline-filled implant between May 1995 and June 2011. The authors had been analyzed the causes of deflation, survival duration, symptom, sign, nipple excision, volume of implant, saline filling, method of reoperation, breast cancer stage and combined capsular contracture. Results: The causes of deflation were attributed to the cases that cannot be evaluated the causes in 15 cases, fall down in 1 case, mammography in 2 cases, accidental needle injury in 1 case. Mean survival duration was 4 years and 5 months. The duration of survival was less than 1 year for 5 cases, 1 year to 10 years for 10 cases, more than 10 years for 4 cases. The volume between 201 and 250 cc of deflated breast implant was rated as high by 14.0 percent. The deflation rate of underfilled implants was 11.4 percent, adequate filled implants was 9.3 percent. None of overfilled implant was deflated. The deflation of smooth surface implant was 5 of 152 cases. Textured implant was 14 of 49 cases. The capsular contracture of non-deflated breast implant was 28 of 182 cases and that of deflated breast implant was 6 of 19 cases. Conclusion: The patients who underwent saline-filled breast implant implantation should be informed that their implant could deflate. The analysis of clinical durability and causes of deflation in breast implant was important for the prediction and prevention of reopeation. The authors could suppose the causes of deflation of saline-filled breast implant through history, duration of survival, inspection of the shell of implant.

Breast Augmentation using Expandable Implants (확장성(더블루멘) 보형물을 이용한 유방확대술)

  • Sim, Hyung Bo;Nam, Sang Jae;Yoon, Sang Yup
    • Archives of Plastic Surgery
    • /
    • v.32 no.4
    • /
    • pp.416-420
    • /
    • 2005
  • Ideal results of augmentation mammaplasty consist of symmetry, natural shape, soft feeling and inconspicuous scar. In addition, patient's preferences about size and shape should be included. Static implants could not perfectly satisfy patients' desires for size and shape, but expandable implants enable to change the volume after the operation. From September 2001 to September 2004, 76 patients(150 breasts) underwent breast augmentation using permanent expandable implant. The procedure was unilateral in 2 women and bilateral in 74 women. Age ranged from 19 to 50 years(mean, 29 years). Fifty nine patients underwent simple augmentation mammaplasty, 7 patients were corrected of their severe asymmetry, 2 patients with the congenital breast deformity underwent mammaplasty using this, and 2 patients who had undergone unilateral mastectomy were reconstructed of their breasts using expandable implant. There were no definite complications such as capsular contracture, implant rupture, asymmetry. And there reported little dissatisfaction about the size. The permanent expandable implants might be good alternatives in cases of ordinary breast augmentation as well as tissue deficient patients, asymmetry, congenital anomaly, and breast reconstruction.

Implant Breast Reconstruction using AlloDerm Sling; Clinical Outcomes and Effect to Capsular Formation (알로덤 슬링술을 이용한 보형물 유방재건술; 임상경과 및 피막형성에 미치는 영향)

  • Yoon, Jung Ho;Kim, Young Seok;Roh, Tai Suk
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.755-760
    • /
    • 2009
  • Purpose: Breast surgeons usually insert tissue expander or implant beneath the subpectoral - subglandular dual plane in breast reconstruction. But sometimes it happens unsatisfactory lower pole fullness, asymmetric inframammary fold and breast shape because there is implant migration due to the pectoralis major muscle contraction and gravity. To solve all the problem like these, we introduce implant breast reconstruction using AlloDerm$^{(R)}$(LifeCell Corp., Branchburg, N.J.) sling. Methods: The AlloDerm$^{(R)}$ sling was used in 13 patients and 18 breasts for implant breast reconstruction. After mastectomy, costal and lower sternal insertion of pectoralis major muscle was detached. Rehydrated AlloDerm$^{(R)}$ was sutured to the chest wall and serratus anterior fascia at the level of inframammary fold downward and to lower border of the pectoralis major muscle upward like crescent shape with tension free technique after implant insertion into the subpectoral - subAlloDerm dual pocket. Results: We make satisfactory lower pole fullness, symmetric inframammary fold and breast shape. In conclusion, patients obtain relatively natural breast shape. There was no complication except one case of capsular contracture and one case of breast cellulitis. Conclusion: Implant breast reconstruction using AlloDerm$^{(R)}$ sling makes easy to get natural breast shape through satisfactory lower pole fullness, symmetric inframammary fold and implant positioning.

Outcome of complete acellular dermal matrix wrap with polyurethane implant in immediate prepectoral breast reconstruction

  • Naemonitou, Foteini;Mylvaganam, Senthurun;Salem, Fathi;Vidya, Raghavan
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.567-573
    • /
    • 2020
  • Background Polyurethane implants have been used on and off in breast reconstruction since 1991 while prepectoral breast reconstruction has gained popularity in recent times. In this study, we present our outcomes from the use of acellular dermal matrix (ADM) complete wrap with polyurethane implants in prepectoral breast reconstruction. Methods This is a retrospective review of prospectively maintained database from 41 patients receiving complete ADM wrap with prepectoral polyurethane implants over a 3-year period. Selection criteria were adapted from a previous study (4135 Trust Clinical Audit Database) evaluating prepectoral reconstruction with Braxon matrices. Patient demographics, operative data, surgical complications, and outcomes were collected and analyzed. Results A total of 52 implant reconstructions were performed in 41 patients with a mean follow-up of 14.3 months (range, 6-36 months). The overall reported complication rates including early (less than 6 weeks) and late complications. Early complications included two patients (4.9%) with wound dehiscence. One of which had an implant loss that was salvageable. Another patient (2%) developed red-breast syndrome and two women (4.9%) developed with seroma treated conservatively. Late complications included one patient (2%) with grade II capsular contraction, 12 patients with grade I-II rippling and two patients (4.9%) with grade III rippling. Conclusions We present our experience of prepectoral polyurethane implant using complete ADM wrap. This is one of the few papers to report on the outcome of the prepectoral use of polyurethane in immediate implant-based breast reconstruction. Our early observational series show satisfactory outcome and long-term results are warranted by a large multicenter study.

Reverse Abdominoplasty with Augmentation Mammoplasty Using Breast Implant: A Case Report (보형물을 이용한 유방성형술을 동반한 역복부성형술의 치험례)

  • Bae, In-Ho;Lee, Yoon-Ho
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.535-538
    • /
    • 2011
  • Purpose: The reverse abdominoplasty has been reported infrequently as a procedure to improve the upper abdominal wall contour. Especially, there have been rare cases on the surgical techniques with augmentation mammoplasty using implant. It is known to maintain the result. Methods: This is a retrospective review of the senior surgeon's patients who underwent reverse abdominoplasty with augmentation mammoplasty. A 63-year-old female was dissatisfied with her contracted breast and upper abdominal contour after previous abdominal wall liposuction. We performed reverse abdominoplasty with augmentation mammoplasty through same inframammary incision. Results: There was a significant improvement of the upper abdominal wall and breast contour. There was no perioperative complication. The patients was satisfied with the results and retained a good shape during the 3 months follow-up periods. Conclusion: Reverse abdominoplasty with augmentation mammoplasty is an acceptable technique that provides good results and should be considered in cases of upper abdominal laxity with capsular contracture on both breasts.

A Retrospective Analysis of Ruptured Breast Implants

  • Baek, Woo Yeol;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.734-739
    • /
    • 2014
  • Background Rupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants. Methods We performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone), duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management. Results Forty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case), microfat graft (2 case), removal only (14 case), and follow-up loss (17 case). Conclusions Saline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.