• Title/Summary/Keyword: Implant Treatment

Search Result 1,621, Processing Time 0.025 seconds

THE STUDY OF THE DENTAL PLAQUE FORMATION ON DIFFERENT IMPLANT SURFACES (임플란트 표면에 따른 인공치면세균막 형성에 관한 연구)

  • Kim, Jin-Woo;Han, Se-Jin;Kim, Kyung-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.325-340
    • /
    • 2008
  • The purpose of this study was to evaluate the artificial dental plaque by Streptococcus mutans on 4 different implant surfaces. In this study, the specimens were divided into 4 groups according to implant surface treatment. Uncoated implant group(n=5) which has an uncoated, smooth surfaced implant(Osstem, Korea), SLA implant group(n=5) which has an sandblasted large grit and acid-etched surface implant(Bicon, USA). Oxidized implant group(n=5) which has an oxidized surfaced implant (Osstem, Korea), and RBM implant group(n=5) which has resorbable blasting media(RBM) surfaced implant(Osstem, Korea). Acquired pellicle by human saliva and dental plaque by Streptococcus mutans were made on each implant surface. To analyze the plaque condition on implants surfaces, cell count and optical density were taken as a microbiologic method, and SEM(Scanning Electronic Microscope) findings was also taken for evaluation of surface condition. The following results were obtained. 1. Cell counting results of artificial dental plaque were Uncoated group($658.0{\pm}102.0$), RBM group($878.0{\pm}170.0$), SLA group ($946.0{\pm}42.0$), Oxidized group($992.0{\pm}40.0$), and there was difference between Oxidized group and Uncoated implant group(p<0.05). In case of modified cell counting results by v/w% were RBM group($197.8{\pm}45.2$), Oxidized group($207.04{\pm}8.34$), Uncoated group($261.6{\pm}40.6$), SLA group($315.4{\pm}14.0$), and there was difference between RBM group and SLA group(p<0.05). 2. Optical density results of artificial dental plaque after ultrasonic treatment was that there was difference among groups, and optical density of RBM group was higher than that of Uncoated group(p<0.05). In case of modified optical density results by v/w%, there was difference among groups, and the modified optical density of Uncoated group and SLA group was higher than those of Oxidized group and RBM group(P>0.05). 3. SEM findings of artificial dental plaque on the surfaces of implant as follows; there were artificial dental plaque on the surfaces of all test implants. Streptococcus mutans and by-product were observed at 10,000 times magnified condition on all test implants. Adhesion area of artificial dental plaque was about 1/2 of total surface after 24 hours incubate at $37^{\circ}C$. These results showed that there were differences among implant surfaces on the growth of Streptococcus mutans, and bacteria and by-product were covered about 1/2 area of total implant surfaces at 24 hours incubate at $37^{\circ}C$.

In situ dental implant installation after decontamination in a previously peri-implant diseased site: a pilot study

  • Kim, Young-Taek;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • Purpose: The aim of this study was to examine whether a previous peri-implantitis site can affect osseointegration, by comparing implant placement at a site where peri-implantitis was present and at a normal bone site. A second aim of this study was to identify the tissue and bone reaction after treating the contaminated implant surface to determine the optimal treatment for peri-implant diseases. Methods: A peri-implant mucositis model for dogs was prepared to determine the optimal treatment option for peri-implant mucositis or peri-implantitis. The implants were inserted partially to a length of 6 mm. The upper 4 mm part of the dental implants was exposed to the oral environment. Simple exposure for 2 weeks contaminated the implant surface. After 2 weeks, the implants were divided into three groups: untreated, swabbed with saline, and swabbed with $H_2O_2$. Three implants from each group were placed to the full length in the same spot. The other three implants were placed fully into newly prepared bone. After eight weeks of healing, the animals were sacrificed. Ground sections, representing the mid-buccal-lingual plane, were prepared for histological analysis. The analysis was evaluated clinically and histometrically. Results: The untreated implants and $H_2O_2$-swabbed implants showed gingival inflammation. Only the saline-swabbed implant group showed re-osseointegration and no gingival inflammation. There was no difference in regeneration height or bone-to-implant contact between in situ implant placement and implant placement in the new bone site. Conclusions: It can be concluded that cleaning with saline may be effective in implant decontamination. After implant surface decontamination, implant installation in a previous peri-implant diseased site may not interfere with osseointegration.

The retrospective study of the prognosis of implants in chronic periodontitis patients (만성 치주염 환자에서 임프란트의 예후에 관한 후향적 연구)

  • Kim, Ji-Eun;Park, Kwang-Ho;Cho, Kyoo-Sung;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.373-382
    • /
    • 2003
  • The successful use of osseointegrated implants to replace missing teeth has been demonstrated for both the completely and the partially edentulous patients. Many studies have confirmed an excellent long-term prognosis. The successful outcome of any implant procedure is surely dependent on the interrelationship of the various components that includes the following: biocompatibility of the implant material, macroscopic and microscopic nature of the implant surface, the status of the implant bed in both a health(noninfected) and a morphologic(bone quality) context, the surgical technique, the undisturbed healing phase, the subsequent prosthetic design, and long-term loading phase. Periodontally compromised patients have poor status of the implant bed and periodontal pathogen. No longitudinal data are available whether these factors affect the prognosis of implants. In this study, 102 machined $Br{{\aa}}nemark$ implants are inserted to analyze the success rate of 1-4 years and marginal bone loss in 49 chronic periodontitis patients. The following conclusions could be drawn from this study. 1. The cumulative success rate of implants at the 4-year of loading was 95.10%. 2. 5 failed implants have been removed. One implant have been removed due to infection, two implants were removed due to failure of osseointegration. and other two implants were removed due to mechanical failure caused by over-loading. 3. Mean marginal bone loss from the time of loading was 0.94mm at first year, 1.12mm at second year, 1.25mm at third year. These results suggest that implant therapy is good treatment modality in chronic periodontitis patients, and periodontal treatment including oral hygiene program is completed prior to insertion of implants.

An assessment of template-guided implant surgery in terms of accuracy and related factors

  • Lee, Jee-Ho;Park, Ji-Man;Kim, Soung-Min;Kim, Myung-Joo;Lee, Jong-Ho;Kim, Myung-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.440-447
    • /
    • 2013
  • PURPOSE. Template-guided implant therapy has developed hand-in-hand with computed tomography (CT) to improve the accuracy of implant surgery and future prosthodontic treatment. In our present study, the accuracy and causative factors for computer-assisted implant surgery were assessed to further validate the stable clinical application of this technique. MATERIALS AND METHODS. A total of 102 implants in 48 patients were included in this study. Implant surgery was performed with a stereolithographic template. Pre- and post-operative CTs were used to compare the planned and placed implants. Accuracy and related factors were statistically analyzed with the Spearman correlation method and the linear mixed model. Differences were considered to be statistically significant at $P{\leq}.05$. RESULTS. The mean errors of computer-assisted implant surgery were 1.09 mm at the coronal center, 1.56 mm at the apical center, and the axis deviation was $3.80^{\circ}$. The coronal and apical errors of the implants were found to be strongly correlated. The errors developed at the coronal center were magnified at the apical center by the fixture length. The case of anterior edentulous area and longer fixtures affected the accuracy of the implant template. CONCLUSION. The control of errors at the coronal center and stabilization of the anterior part of the template are needed for safe implant surgery and future prosthodontic treatment.

Analysis of surface form change after performing prophylaxis procedure on implant surface using various oral hygiene instruments (다양한 구강위생기구를 이용하여 임플란트 표면의 Prophylaxis 시행시 표면형태의 변화분석)

  • Lee, Sun-Goo;Lim, Sung-Bin;Chung, Chin-Hyung;Kwon, Sang-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.1-17
    • /
    • 2004
  • It is improtant that performing prophylaxis procedure on an infected implant surface in order to treat peri-implantitis should not change the surface roughness and composition, so that the surface can be recovered to almost same condition as initial implant surface. This thesis, therefore, studied an effect of various oral hygiene instrument on implant surface. A surface roughness measurement instrument and an infection electron microscope were used to observe a change on surface. The purpose of this study was to obtain a clinical guidelines during implant care and peri-implantitis treatment. The result were as follows 1. Ra values (surface roughness value) at experimental group 1, group 2, and group 5 were increased significantly as compared with comparison group(p<0.05). 2. When compared experimental group 1 with each experimental groups at which prohylaxis procedure was performed, mean values of Ra at experimental group 2, group 3, group 6, and group 7 were decreased significantly(p<0.05). 3. Mean value of Ra was lowest at experimental group 2, and highest at experimental group 2, and highest at experimental group 5. 4. Analysis of SEM showed that was significant surface change at experimental group 2, group 3, group 4, group 5, and group 6 as compared with comparison group(X1000). 5. Analysis fo EDX showed that a quantity of Ti on surface for experimental group 6 was very similar to that for comparison group. In conclusion, air-powder abrasive and citric acid, plastic instrument are safe methods to use for performing prophylaxis procedure on implant care or for cleaning and sterilization process on treatment of peri-implantitis, based on the result that those method did not affect implant surface roughness and Ti composition.

Full mouth rehabilitation utilizing computer guided implant surgery and CAD/CAM (Computer guided implant surgery와 CAD/CAM을 활용한 전악 수복 증례)

  • Kim, Sungjin;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.57-65
    • /
    • 2019
  • Computer aided design and manufacturing and implant surgery using a guide template improve restoration-driven implant treatment procedures. This case utilized those digital technologies to make definitive prostheses for a patient. According to the work flow of digital dentistry, cone beam computed tomography established the treatment plan, which was followed to make the guide template for implant placement. The template guided the implants to be installed as planned. The customized abutments and surveyed fixed restorations were digitally designed and made. The metal framework of the removable partial denture was cast from resin pattern using an additive manufacturing technique, and the artificial resin teeth were replaced with the zirconia onlays for occlusal stability. These full mouth rehabilitation procedures provided functionally and aesthetically satisfactory results for the patient.

Factors affecting maxillary sinus pneumatization following posterior maxillary tooth extraction

  • Lim, Hyun-Chang;Kim, Sangyup;Kim, Do-Hyup;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.285-295
    • /
    • 2021
  • Purpose: The aims of the present study were 1) to quantitatively evaluate the extent of sinus pneumatization and 2) to determine the factors affecting sinus pneumatization. Methods: Based on implant treatment records, a list of patients who underwent implant placement on the posterior maxilla was obtained. Among them, patients with pre-extraction and post-extraction (before implant placement) panoramic radiographs were selected. After excluding radiographs with low resolution and image distortion, the radiographs before and after extraction were superimposed using computer software. Subsequently, the extent of sinus pneumatization (the vertical change of the sinus floor) was measured. Simple and multiple mixed models were used to determine the factors affecting sinus pneumatization. Results: A total of 145 patients were eligible for the present investigation. The average extent of sinus pneumatization was 1.56±3.93 mm at 176 tooth sites. Male sex, single tooth extraction, extraction of an endodontically compromised tooth, a class I root-sinus relationship, and sinus membrane thickening >10 mm favored pneumatization, but without statistical significance. The maxillary second molar presented the greatest pneumatization (2.25±4.39 mm) compared with other tooth types. This finding was confirmed in the multiple mixed model, which demonstrated a statistically significant impact of the extraction of a second molar compared with the extraction of a first premolar. Conclusions: Maxillary sinus pneumatization was 1.56±3.93 mm on average. The extraction of a second molar led to the greatest extent of pneumatization, which should be considered in the treatment plan for this tooth site.

Overcoming and Preventing Dental Implant Complications: Abutment Fracture Case Report

  • Kahm, Se Hoon;Kim, Chang-Hyun;Kim, Sung-Joon
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.27-33
    • /
    • 2013
  • The introduction of osseointegrated dental implants in dentistry brought about a new era in everyday dental practice. For the past 50 years, prosthetic restoration with implant-supported prosthesis has developed into a viable and predictable treatment option. Alongside the increasing use of dental implants is the occurrence of many complications during implant placement (surgery), in the mechanical or prosthetic problem, and in the biological aspect. In particular, abutment or screw fracture as one of the mechanical complications can put the dentist in a tight spot in a clinical situation. It is hard to remove the fractured abutment and screw to restore it properly. Therefore, it is very important that clinicians consider possible complications in advance and make an appropriate treatment plan. We discuss cases of abutment fracture and mechanical/prosthetic complications together with the causes and solutions.

Implant treatment to reduce complications : Maxillary sinus elevation and bone graft (lateral wall approach) Failures and Problem solving (Complication을 줄이기 위한 임플란트 치료 상악동거상술 및 골 이식술(측벽접근법) 실패 및 문제점 해결)

  • Choi, Byung-Joon
    • The Journal of the Korean dental association
    • /
    • v.58 no.9
    • /
    • pp.573-582
    • /
    • 2020
  • Today, maxillary sinus graft is considered to be the most prognostic of bone augmentation surgery as a preprosthetic treatment. Implant survival rates of more than 95% can be expected if appropriate decisions are made on the basis of implants, implant surface morphology, and use of a shield over the maxillary sinus front-wall. In addition, maxillary sinus grafty has a low rate of complications, and even if complications occur during or after maxillary sinus graft, most are localized and easily recovered.

  • PDF

Pharmacologic management for the patient with paresthesia after implant surgery or extraction (임프란트 수술이나 발치 후 지각이상 환자에서의 약물치료)

  • Kim, Seong-Taek;Kim, Il-Young;Gang, Hee-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.109-113
    • /
    • 2003
  • The inferior alveolar nerve provides unilateral innervation to the dentition, labial mucosa and skin from about commissure to the mental protuberance. Injury to this nerve resulting in sensory impairment can be a distressing problem to some patients. The causes of this problem include trauma, extraction, implant surgery and any maxillofacial surgery and generally the altered sensation is temporary. The surgical procedure has been the most common treatment for this condition but it has some complications. The antidepressants and anticonvulsants have been effective to the treatment of trigeminal dysesthesia. This case report suggests that the use of antidepressants and anticonvulsants is an alternative method to treat the paresthesia after implant surgery or extraction.