• Title/Summary/Keyword: Implant Treatment

Search Result 1,621, Processing Time 0.028 seconds

Functional Endoscopic Sinus Surgery for a Patient with Maxillary Sinusitis Occurring after Implant Placement

  • You, Jae-Seek;Kim, Su-Gwan;Oh, Ji-Su;Jeong, Gyeong-Dal;Mah, Deuk-Hyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.331-336
    • /
    • 2013
  • Maxillary sinus membrane elevation and bone graft have been performed routinely in alveolar bone with insufficient residual bone height. There are a number of causes for development of maxillary sinusitis after these procedures. When maxillary sinusitis is caused by sinus membrane elevation, bone graft, and implant placement, various treatment such as medication, incision and drainage (I&D), implant removal, and the Caldwell-Luc procedure can be considered. Removal of an implant or the Caldwell-Luc procedure can be harmful if inflammation is not present in the oral cavity and survival of grafted bone and implant osseointegration can be expected despite the presence of maxillary sinusitis. In this case, functional endoscopic sinus surgery, which was often used in the otorhinolaryngology department, was performed without removal of the implant for a patient with maxillary sinusitis after one month following implant placement. Thus, we report on this case with a review of the literature.

Correlation between quality of sleep and dental fear in implant surgery patients (치과 임플란트 수술 환자의 수면 질과 공포감의 관련성)

  • Jin, Mi-Young;Kim, Sun-Ok;Yu, Byeng-Chul
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.3
    • /
    • pp.371-379
    • /
    • 2014
  • Objectives : The purpose of this study is to investigate the correlation between quality of sleep and dental fear in implant surgery patients. Methods : A self-reported questionnaire was filled out by 153 implant patients from December 2012 to February 2013 in dental clinics and hospitals in Busan and Changwon. Data were analyzed by descriptive analysis, t-test, ANOVA and multiple regression analysis using SAS version 9.20. Results : The quality of sleep in the implant patients was $41.0{\pm}6.0$. The systemic diseases influenced on the quality of sleep and dental fear also affected the quality of sleep. Conclusions : The results of the analysis of a relationship between the fear perception of dental implant surgery patients and the quality of their sleep showed that the patients with systemic diseases, the patients with a fear by the physical stimulation relating to implant treatment showed the low quality of sleep.

Effect of Sustained-Release of Adenosine by Elvax 40P Implant on Mouse Mammary Development (생쥐의 유선발달에 있어서 Elvax 40P Implant를 이용한 서방형 Adenosine의 역할)

  • 여인서;박춘근;홍병주
    • Korean Journal of Animal Reproduction
    • /
    • v.16 no.4
    • /
    • pp.387-397
    • /
    • 1993
  • To examine local response of adenosie(purine nucleoside) on the developing mammary gland, Elvax 40P implants containing adenosine were surgically implanted into mammary fat pad of the five week old female ICR mice. Inguinal(the 4th) mammary glands of anesthetized mice were exposed andplaced the implants for 12 days. One gland was treated with an adenosine implant, while the contralateral gland received a blank implant as control. For whole-mount preparations, glands were stained with alum carmine, and for histological observation, micro-selected mammary glands were stained with hematoxylin and eosin Y. Implantation with Elvax 40P did not affect on the damage of neighboring mammary tissue. Adenosie 25 or 250$\mu\textrm{g}$ per slow-release implant stimulated local mammary end bud formation of ovariectomized mice such as end bud size and numbers of end bud per gland in a dose dependent manner(P<0.05), and lower concentration of adenosie(2.5 or 25$\mu\textrm{g}$/implant) increased numbers of end bud(P<0.05) and end bud size(P<0.1) of intact mice. Adenosine treatment and intact ovarian function had moderate interation effects on the stimulation of end bud formation at 2.5$\mu\textrm{g}$ adenosine/implant(P<0.1). In histological observation, adenosine implants increased numbers of mammary epithelial type of cells at mammary duct in the presence or absece ofovary. These results indicate that adenosine should be one of regulators in mouse mammary ductal growth.

  • PDF

Peri-implant disease: what we know and what we need to know

  • Valente, Nicola Alberto;Andreana, Sebastiano
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.3
    • /
    • pp.136-151
    • /
    • 2016
  • Peri-implant disease is a serious problem that plagues today's dentistry, both in terms of therapy and epidemiology. With the expansion of the practice of implantology and an increasing number of implants placed annually, the frequency of peri-implant disease has greatly expanded. Its clinical manifestations, in the absence of a globally established classification, are peri-implant mucositis and peri-implantitis, the counterparts of gingivitis and periodontitis, respectively. However, many doubts remain about its features. Official diagnostic criteria, globally recognized by the dental community, have not yet been introduced. The latest studies using metagenomic methods are casting doubt on the assumption of microbial equivalence between periodontal and peri-implant crevices. Research on most of the features of peri-implant disease remains at an early stage; moreover, there is not a commonly accepted treatment for it. In any case, although the evidence so far collected is limited, we need to be aware of the current state of the science regarding this topic to better understand and ultimately prevent this disease.

Maxillary Anterior Implant Placement with Various Bone Agumentation on Atrophic Thin Ridge : Case Reports (다양한 골증대술을 동반한 상악전치부 임플란트 식립 증례)

  • Chee, Young-Deok;Jo, I-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.145-155
    • /
    • 2007
  • The advent of osseointegration and advances in biomaterials and techniques have contributed to increased application of dental implants in the restoration of maxillary partial edentulous patients. Often, in these patients, soft and hard tissue defects result from a variety of causes, such as infection, trauma, and tooth loss. These create an anatomically less favorable foundation for ideal implant placement. Reconstruction of the atrophic maxillary alveolar bone through a variety of regenerative surgical procedures has become predictable; it may be necessary prior to implant placement or simultaneously at the time of implant surgery to provide a restoration with a good long-term prognosis. Regenerative procedures are used for horizontal and vertical ridge augmentation. Many different techniques exist for effective bone augmentation. The approach is largely dependent on the extent of the defect and specific procedures to be performed for the implant reconstruction. It is most appropriate to use an evidenced-based approach when a treatment plan is being developed for bone augmentation cases. The cases presented in this article clinically demonstrate the efficacy of using a autogenous block graft, guided bone regeneration, ridge split, immediated implant placement technique on the atrophic maxillary area.

A 10-YEAR RETROSPECTIVE CLINICAL STUDY OF $BR{\AA}NEMARK$ IMPLANTS ($Br{\aa}nemark$ 임플랜트의 10년 후향적 임상연구)

  • Bae, Jung-Yoon;Shin, Sang-Wan;Cho, Hyun-Jung;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.48-59
    • /
    • 2007
  • Statement of problems: There are few studies which reported the survival rates of the specific dental implant systems in the Korean population with the follow-up periods longer than 5 years. Purpose: This retrospective clinical study was aimed to evaluate cumulative survival rate (CSR) of $Br{\aa}nemark$ implants followed for 10 years and to determine risk factors for implant failure. Material and methods: A total of 271 $Br{\aa}nemark$ implants in 83 patients were investigated with several identified risk factors. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR. Results: Thirty implants failed. The 10-year implant CSR was 82.5%. Cox regression analysis demonstrated a significant predictive association between overall CSR and implant length (P<.05). Conclusion: An acceptable long-term result of $Br{\aa}nemark$ implant was achieved and implant length showed a significant association with the CSR.

Ridge split for implant placement in very thin alveolar ridge (매우 얇은 치조골에서 치조능 분할 확장술을 통한 임플란트 치료)

  • Kim, Sin-Guen;Lee, Hee-Sung;Park, Jong-Wook;Nam, Jong-Hoon;Bok, Sung-Cheol;Park, Ki-Nam;Choi, Dong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.3
    • /
    • pp.229-233
    • /
    • 2011
  • For implant treatment there must be sufficient bone to house the implant body. At least 5mm wide residual bone is needed and usually a 6mm width is preferred by clinicians. However, surgeons sometimes find patients with a narrow ridge, which makes it difficult to place an implant. Therefore, many clinicians perform bone graft or a ridge splitting technique to overcome these poor conditions. The time and cost can be reduced using the ridge splitting technique with immediate implant placement. Recently, many studies reported reliable consequences of ridge splitting technique. This paper reports a successful of implant placement with a ridge splitting technique in a very thin alveolar ridge.

Implant-supported overdenture with prefabricated bar attachment system in mandibular edentulous patient

  • Ha, Seung-Ryong;Kim, Sung-Hun;Song, Seung-Il;Hong, Seong-Tae;Kim, Gy-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.254-258
    • /
    • 2012
  • Implant-supported overdenture is a reliable treatment option for the patients with edentulous mandible when they have difficulty in using complete dentures. Several options have been used for implant-supported overdenture attachments. Among these, bar attachment system has greater retention and better maintainability than others. SFI-Bar$^{(R)}$ is prefabricated and can be adjustable at chairside. Therefore, laboratory procedures such as soldering and welding are unnecessary, which leads to fewer errors and lower costs. A 67-year-old female patient presented, complaining of mobility of lower anterior teeth with old denture. She had been wearing complete denture in the maxilla and removable partial denture in the mandible with severe bone loss. After extracting the teeth, two implants were placed in front of mental foramen, and SFI-Bar$^{(R)}$ was connected. A tube bar was seated to two adapters through large ball joints and fixation screws, connecting each implant. The length of the tube bar was adjusted according to inter-implant distance. Then, a female part was attached to the bar beneath the new denture. This clinical report describes two-implant-supported overdenture using the SFI-Bar$^{(R)}$ system in a mandibular edentulous patient.

3D-printed titanium implant with pre-mounted dental implants for mandible reconstruction: a case report

  • Park, Jung-Hyun;Odkhuu, Michidgerel;Cho, Sura;Li, Jingwen;Park, Bo-Young;Kim, Jin-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.28.1-28.4
    • /
    • 2020
  • Background: This clinical case presented a novel method of segmental mandible reconstruction using 3D-printed titanium implant with pre-mounted dental implants that was planned to rehabilitate occlusion. Case presentation: A 53-year-old male who suffered osteoradionecrosis due to the radiation after squamous cell carcinoma resection. The 3D-printed titanium implant with pre-mounted dental implant fixtures was simulated and fabricated with selective laser melting method. The implant was successfully inserted, and the discontinuous mandible defect was rehabilitated without postoperative infection or foreign body reaction during follow-ups, until a year. Conclusions: The 3D-printed titanium implant would be the one of the suitable treatment modalities for mandible reconstruction considering all the aspect of mandibular functions.

Case report: Application of Implant Supported Removable Partial Denture due to Multiple Dental Implant Loss of the Fixed Implant Supported Prosthesis (다수의 임플란트발거로 임플란트 고정성 보철이 실패한 환자에서의 잔존 임플란트를 이용한 부분 가철성 국소의치 수복증례)

  • Kang, Jeong Kyung;Nam, Gi Hoon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2014
  • There are several treatment options for rehabilitation of partial edentulism including the use of conventional or implant-retained fixed prostheses. However, such prosthetic options cannot always be possible because of compromised general and oral health (i.e. loss of supporting tissues, medical reasons, extensive surgical protocol and osseointegration failure of dental implant) as well as the affordability of patients. In some cases, removable partial denture provides easier access for oral hygiene procedures and the ability to correct discrepancies in dental arch relationships than implant fixed prosthesis. Recently, Implant Supported Removable Partial Denture (ISRPD) where to place dental implant in strategic position has been suggested to improve the limitation and shortcomings of conventional RPD. ISPRD can overcome mechanical limition of conventional RPD by placing implant in a favorable position and can be cost-effective, prosthetic solution for partially edentulous patients who are not immediate candidates for extensive, fixed implant supported restorations. Incorporation of dental implants to improve the RPD support and retention and to enhance patient acceptance should be considered when treatment planning for RPD. In this case, 59 years old male patient who received dental treatment of implant fixed prosthesis on both side of the upper jaw and implant overdenture on lower jaw showed implant abutment screw fracture on #15i and osseointegration failure on multiple number of implants. After removing failed implants, we planned ISRPD using #15i,24i,25i,26i and #23 natural tooth for RPD abutment. We fabricated #23 surveyed crown,#24i=25i=26i surveyed bridge and #15i gold coping for support,retention and stability for RPD. Periodic follow up check for 2years has been performed since the ISRPD delivery to the patient. No sign of screw loosening, fracture or bone resorption around abutment implants were detected.