• 제목/요약/키워드: Implant Patient

검색결과 990건 처리시간 0.027초

Silicone Implant 삽입 후에 발생한 안와내 거대 낭종 (Large Intraorbital Cyst after Silicone Implant Insertion: A Case Report)

  • 하상욱;이혜경;유원민;탁관철
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.659-662
    • /
    • 2006
  • Purpose: Alloplastic implants, such as methylmethacrylate, Teflon, silicone, Supramid are commonly used to cover the floor defect and to prevent reherniation of the displaced orbital tissue in orbital floor fracture. Silicone implant has been used for reconstruction of orbital wall defects because of pliability, advantage of carving and chemically inert nature. However, silicone implant also has complications including infection, extrusion, pain, dystopia and tissue reaction. Cyst formation around the silicone implant is a very rare complication. According to many reports, cysts around alloplastic implant in an orbital area are mostly hemorrhagic cysts consisted of blood breakdown product with fibrous capsule cell in histologic examination. Methods: The authors report atypical case and successful treatment of intraorbital hemorrhagic cyst around silicone implant of a 37-year-old male patient. Results: Preoperative symptoms of diplopia, exophthalmos, proptosis, vertical dystopia and ectropion of lower eyelid were resolved after surgical removal of implants with surrounding capsule. Conclusion: Clinical suspicion of plastic surgeon is important in diagnosis of intraorbital cyst of patients who have history of silicone implantation and computed tomography is the standard tool of diagnosis. During the operation, caution must be taken on delivering the whole capsule of intraorbital cyst along with silicone implant to prevent recurrence of the cyst.

미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구 (Multicentric retrospective clinical study on the clinical application of mini implant system)

  • 김영균;여인성;이양진;김운규;문경남;전승준;조용석;윤필영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권4호
    • /
    • pp.325-330
    • /
    • 2010
  • Introduction: Mini-implant system is applicable to areas of narrow space and area requiring temporary loading support. The purpose of this study was to evaluate the clinical outcome of a mini-implant system as well as the application of mini-implant system in the dental clinical field. Materials and Methods: The patients who had been operated from Jan 2007 to Dec 2007 in the four dental facility including Seoul National University Bundang Hospital were enrolled. To evaluate the factors associated with the clinical outcome, the patients were classified according to gender, age, area of surgery, type of implant, diameter and length of the implant, and the purpose of the mini-implant system application. Results: From 147 implants, only three implants failed, one of them was for temporary loading. There were no serious surgical or prosthetic complications in this study. Conclusion: An analysis of the preliminary data revealed a satisfactory clinical outcome. However, more long-term evaluation of narrow ridge type as well as the patient’s satisfaction on the use of a provisional type mini-implant system is needed.

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

근단 변위 판막술을 사용한 임플란트 주위 각화조직 폭경의 증대: 증례보고 (Increase of the Width of Peri-implant Keratinized Tissue using Apically Positioned Flap: Case Report)

  • 지영덕;선화경
    • 구강회복응용과학지
    • /
    • 제29권4호
    • /
    • pp.407-417
    • /
    • 2013
  • 임플란트 치료의 유지단계에서 임플란트 주변 연조직의 문제 중 하나는 부착조직의 부족한 범위이다. 각화 조직은 치아 및 임플란트 주변에서 구강 위생의 유지 및 개선에 있어서 중요한 역할을 한다. 유리 치은 이식술은 연조직 부족을 해결하고 임플란트 보철의 장기간의 예후를 증가시키기 위해 최적의 임플란트 주변 건강을 제공한다. 그러나 유리 치은 이식술 치료를 받은 환자들은 구개와 같은 공여부 상의 통증 및 불편감을 호소한다. 뿐만 아니라 술자에게 있어 기술적인 난이도를 요구하며, 시간이 오래걸리고 이상적인 형태와 비교하였을 때 종종 조직의 색깔 차이가 발생하는 등의 단점이 있다. 근단변위판막술은 임플란트 2차 수술과 동반하여 또는 이후에 간단히 부착 조직을 증대시키기 위해 선택된다. 이번 증례보고에서는 유리치은이식술을 대신하여 작은 범위의 임플란트 부위에서 근단변위판막술을 통한 임플란트 주변 각화 조직의 폭경이 성공적으로 증가했음을 보이고자 한다.

Energy-dispersive X-ray spectroscopic investigation of a fractured non-submerged dental implant associated with abutment fracture

  • Truc Thi Hoang Nguyen;Mi Young Eo;Kezia Rachellea Mustakim;Mi Hyun Seo;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권1호
    • /
    • pp.43-48
    • /
    • 2023
  • The biocompatibility and durability of implant fixtures are major concerns for dentists and patients. Mechanical complications of the implant include abutment screw loosening, screw fracture, loss of implant prostheses, and implant fracture. This case report aims to describe management of a case of fixture damage that occurred after screw fracture in a tissue level, internal connection implant and microscopic evaluation of the fractured fixture. A trephine bur was used to remove the fixture, and the socket was grafted using allogeneic bone material. The failed implant was examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), which revealed a fractured fixture with both normal and irregular bone patterns. The SEM and EDS results give an enlightenment of the failed fixture surface micromorphology with microfracture and contaminated chemical compositions. Noticeably, the significantly high level of gold (Au) on the implant surface and the trace amounts of Au and titanium (Ti) in the bone tissue were recorded, which might have resulted from instability and micro-movement of the implant-abutment connection over an extended period of time. Further study with larger number of patient and different types of implants is needed for further conclusion.

Reliability of implant stability measuring devices depending on various clinical conditions: an in vitro study

  • Han-Na Lee;Myoung-Sub Kim;Jeong-Yol Lee;Xu Zihan;Jae-Jun Ryu;Ji-Suk Shim
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.126-135
    • /
    • 2023
  • PURPOSE. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. MATERIALS AND METHODS. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. RESULTS. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). CONCLUSION. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest.

Implants and all-ceramic restorations in a patient treated for aggressive periodontitis: a case report

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권3호
    • /
    • pp.97-101
    • /
    • 2010
  • A 23-year-old female with aggressive periodontitis was treated using dental implants and LAVA system. The severely compromised teeth were extracted irrespective of initial conservative periodontal treatment. An implant-supported overdenture with 4 implants was fabricated for the maxilla and all-ceramic restorations for the mandible. Esthetic and functional goals were achieved with team approach involving periodontists and prosthodontists. This case report describes a treatment procedure for a generalized aggressive periodontitis patient with severe bone resorption.

두경부 PET/CT검사 시 인공음영 감소에 관한 연구 (환자 피폭선량 경감) (The Study of Decrease Artifact when Scanning Head and Neck PET/CT(Decrease Radiation Dose of Patient))

  • 김기진;김가중;유세종;김정호
    • 대한안전경영과학회지
    • /
    • 제18권1호
    • /
    • pp.153-158
    • /
    • 2016
  • Beam hardening artifact can be caused by metal material when performing PET exam. Therefore, we studied a solution decreasing artifact caused by metallic dental implant. The higher voltage, the lesser artifact in CT exam. But Higher voltage dosen't affect PET exam. The thicker silicon the lesser artifact in CT and PET exam. Both methods make less artifact in CT and PET exam. But considering safety of patient, the way of using silicon is better.

퇴축이 심한 하악구치부에서 양측성 하치조신경 전위술을 이용한 인공치아의 식립

  • 손동석;이수경;박도영
    • 대한치과의사협회지
    • /
    • 제37권4호통권359호
    • /
    • pp.279-286
    • /
    • 1999
  • In patients with severely atrophic mandibular posterior area, implant placement is a problematic surgical procedure. Inferior alveolar nerve transpositioning technique offers better initial stability of implant and reduce the risk of permanent nerve damages. In this case report, the patient has bilateral atrophic mandibular posterior edentulous area. We placed 3 implants on each mandibular posterior area in conjunction with bilateral inferior alveolar nerve transpositioning to achieve sufficient bone height. The patient complained of paresthesia in lower lip and chin area and ptosis of lower lip after surgery. Neurosensory function was normal in 10 weeks after surgery.

  • PDF

Debridement, antibiotics, and implant retention in infected shoulder arthroplasty caused by Serratia marcescens: a case report

  • Lim, Sungjoon;Lee, Jun-Bum;Shin, Myoung Yeol;Jeon, In-Ho
    • Clinics in Shoulder and Elbow
    • /
    • 제25권2호
    • /
    • pp.154-157
    • /
    • 2022
  • Periprosthetic joint infection (PJI) is one of the most devastating complications that can occur after shoulder arthroplasty. Although staged revision arthroplasty is the standard treatment in many cases, surgical intervention with debridement, antibiotics, and implant retention (DAIR) can be an effective option for acute PJI. We report a complex case of infected reverse shoulder arthroplasty (RSA) in a 73-year-old male. The patient had been previously treated for infected nonunion of a proximal humerus fracture caused by methicillin-resistant Staphylococcus epidermidis. He presented with a sinus tract 16 days after the implantation of RSA and was diagnosed with PJI caused by Serratia marcescens. The patient was successfully treated with DAIR and was free of infection at the last follow-up visit at 4 years postoperatively.