Journal of the Korean Academy of Esthetic Dentistry
/
v.25
no.1
/
pp.25-34
/
2016
Treatment of missing mandibular 4 incisors is often thought to be easier then other place during surgical and prothetic procedure. But clinicians encounter unexpected difficulties such as restricted implant site due to mesio-distal width of mandibular incisors, limited space as a result of crowing and mesial drift, esthetic problem after severe alveolar bone resorption, and difficulties of provisionalization Through cases, possible treatment options for missing mandibular incisors would be discussed. Treatment options for missing mandibular 4 incisors Place narrow type implant or one body mini implant on exact tooth position when there is no bone resorption Regular size implant on interseptal bone area when there is severe bone resorption Consider using resin bonded bridge(resin retained bridge/resin bonded fixed partial denture) as a tentative prosthesis when patient resists extracting remaining incisors with poor prognosis.
Edentulous patients with severe alveolar bone resorption have trouble with using traditional complete denture. In order to overcome these problems, implant-retained overdenture was developed. SFI-bar$^{(R)}$ system can save time and cost compared to other existing bar systems which need complicated laboratory procedures because it can be adjusted directly in a patient's mouth. A 55-year-old male, who had experienced a fractured lower old implant-retained overdenture, wanted a durable and painless denture. The fractured Locator$^{(R)}$ attachments were removed and edentulous mandible was restored with SFI-bar$^{(R)}$. A 77-year-old female with a medical history of the Parkinson's disease and severely absorbed alveolar bone of mandible, wanted to wear a retentive mandibular denture without pain. After placing two implants in front of mental foramen, two adaptors were connected to two implants and a tube bar was connected to the adaptors. A female part fitted to the bar was attached to the new denture. These clinical reports describe two-implant-retained overdenture using the SFI-bar$^{(R)}$ system in mandibular edentulous patients. Since the patients were satisfied esthetically and functionally during 2 years' observation, we would like to report cases.
In the case of single tooth replacement, a fixed prosthesis or a dental implant is the treatment option commonly selected as first choice. However, any amount of sound tooth structure should be removed to prepare the abutment teeth for full coverage retainer. The adjacent tooth damage can be avoided placing a dental implant. However, depending on the patient's oral condition and any other circumstances, it may be impossible or delayed. In this case resin bonded fixed partial denture was selected as an alternative that can restore single tooth loss without much tooth structure removal to the young patients and the patients with gingival recession. We report these patients were satisfied with esthetic and function.
Currently CAD/CAM technology has been used widely in dentistry. But it has mainly been focused on fabrication of fixed partial dentures and implant-supported prosthesis. DENTCA company uses new cutting edge of CAD/CAM technology to revolutionize denture production. With developing a CAD/CAM technology of DENTCA company, it is possible to make complete dentures with minimum visits to the clinic. The aim of this article is to introduce a new denture-making method by CAD/CAM.
Journal of Dental Rehabilitation and Applied Science
/
v.23
no.2
/
pp.139-144
/
2007
Prosthodontic treatment planning for various edentulous arches is not an easy issue for dentists. Especially, in case of removable partial denture, we must have a knowledge of overall treatment procedures, and a careful approach is needed. Recently, interest of dental implant and case reports are increasing, the decrease of the removable partial denture is true, but dental implantation takes longer treatment period and it is more expensive. Also, there are still some limitations like lack of available alveolar bone, patient's general condition, and chronic periodontitis. Therefore, sometimes implantation is impossible. Finally, implantation cannot be adapted to every single patient. Currently, the clasp type removable partial dentures are used routinely, giving patients many unesthetic and functional difficulties. With better laboratory technique, removable partial denture with attachment and removable partial denture in rigid type increase patient's happiness level much more than predicted. The case presented in this article, clinically demonstrate the efficiency of using a telescopic system to improve esthetic and functional recovery for patients who lose multiple teeth.
Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.
This study was performed to evaluate the effects of number and alignment of implant fixture and various bar designs on the retention of denture and the stress distribution. Six kinds of photoelastic mandibular models and nine kinds of overdenture specimens were designed. A unilateral vertical load was gradually applied on the right first molar to calculate the maximal dislodgement load of each specimen. A unilateral vertical load of 17 Kgf was applied on the right first molar and a vertical load of 10 Kgf was applied on the interincisal edge region. The stress pattern which developed in each photoelastic model was analyzed by the reflection polariscope. The results obtained were as follows: 1. The maximal dislodgement load reversely increased with the distance from the loading point to the implant fixture, while it linearly increased with that from the most posterior implant fixture to the mesial clip. The maximal dislodgement load also increased with the use of a cantilever bar. 2. Under the posterior vertical load, the stress to the supporting tissue of the denture base increased with the distance from the loading point to the implant future. The stress concentration on the apical area of the implant future reversely increased with the distance from the loading point to the implant future. 3. In the overdentures supported by two implant fixtures under the posterior vertical load. the specimen implanted on lateral incisor areas with a cantilever bar exhibited more favorable stress distribution than that without a cantilever bar. The specimen implanted on the canine areas without a cantilever bar, however, exhibited more favorable stress distribution. 4. In the overdentures supported by three implant fixtures. the specimen implanted ell the midline and canine areas exhibited more favorable stress distribution than that implanted oil the midline and the first premolar areas. 5. In the overdentures supported by four implant fixtures. the specimen implanted with two adjacent implant fixtures exhibited more favorable stress distribution than that implanted at equal distance under the posterior vertical load. 6. Under the anterior vertical load, the overdentures supported by three implant fixtures exhibited stress concentration on the supporting structure of the middle implant future. In overdentures supported by two or four implant futures, no significant difference was noted in stress distribution between the types of bars. These results indicate that the greater the number of implant fixtures, the better the stress distribution is. A favorable stress distribution may be obtained in the overdentures supported by two or three implant fixtures, if the location and the design of the bar are appropriate.
The purpose of this review is to examine the performance of attachments used in implant-supported overdenture (IOD) in both clinical and in vitro settings and report the compiled findings, comparisons, and trends in the research literature. Articles published in PubMed on IOD attachment systems and performance were reviewed. Non-original articles were excluded. For each article included, the type of study, number of implants, number of attachment systems, and study outcome were recorded. Of the 283 articles found, 158 met the inclusion criteria. Ninety-four articles were clinical studies and 64 articles were in vitro studies. Studies on retention were the most common for in vitro studies, and four or more attachment systems were compared in most articles with significant differences in outcome. A clinical outcome of one attachment system was most common for clinical studies, while most studies had neutral outcomes overall. Ball attachment was the most commonly tested IOD attachment system. The trend in the literature showed that there is a large discrepancy between the study designs and outcomes between the clinical and the in vitro studies for IOD. Further clinical studies that can validate in vitro research should be encouraged to address this discrepancy between the two areas.
By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.
Objectives: This study aims to provide data that will improve the scope of national health insurance coverage by surveying the awareness of health insurance benefits, specifically for implants and dentures, among dental workers. Methods: Information was collected through questionnaires completed by 194 dental workers at dental hospitals and clinics. The multiple logistic regression analysis was conducted to confirm influential factors in recognizing the health insurance benefits application for dentures and implants. Results: Regarding the awareness about the validity of health insurance benefits, satisfaction with the appropriateness on the subjects of the denture application and implant application are appeared to be high with each 3.369 and 3.673. Regarding satisfaction with the appropriateness of free post-maintenance for implants, the awareness level regarding the validity of health insurance benefits was indicated as high at 3.673. Conclusions: The categories and levels of appropriate insurance benefits must be restructured continuously.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.