• 제목/요약/키워드: Impedance transducer

검색결과 152건 처리시간 0.023초

Development of an Impedance Matching Layer in an Ultrasound Transducer with Gradient Properties

  • Jeong, Jihoon
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.374-379
    • /
    • 2018
  • The piezocomposite transducer is widely used because it is highly efficient in transforming electric energy into mechanical energy, and its frequency range is broader than that of other types of ultrasound transducers. A general piezocomposite transducer is composed of an acoustic lens, impedance matching layers, piezoelectric materials, and backing layers. When an input voltage is applied to a piezoelectric material as an active material, it generates sound waves while vibrating. At that time, an impedance matching layer helps the sound waves to propagate forward while reducing the impedance mismatch that may occur at the interface between the active material and its front material. The impedance mismatch has a negative effect on the signal of an ultrasound transducer; thus, it is important to design a matching layer to overcome the issue. In this study, an optimized feature of a matching layer with gradient properties is studied. An objective function is defined to minimize both the average and the deviation of the reflection coefficients that are functions of the frequencies. As a result, an improvement in the signal characteristics with respect to the sensitivity and bandwidth is reported.

초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구 (Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency)

  • 김홍래;김성천;김광기;김영우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

소나 송신기의 정합회로 설계를 위한 수중 음향 압전 트랜스듀서의 등가회로 파라미터 추정 (Estimation of Equivalent Circuit Parameters of Underwater Acoustic Piezoelectric Transducer for Matching Network Design of Sonar Transmitter)

  • 이정민;이병화;백광렬
    • 한국군사과학기술학회지
    • /
    • 제12권3호
    • /
    • pp.282-289
    • /
    • 2009
  • This paper presents an estimation technique of the equivalent circuit parameters for an underwater acoustic piezoelectric transducer from the measured impedance. Estimated equivalent circuit can be used for the design of the impedance matching network of the sonar transmitter. A fitness function is proposed to minimize the error between the calculated impedance of the equivalent circuit and the measured impedance of the transducer. The equivalent circuit parameters are estimated by using the fitness function and the PSO(Particle Swarm Optimization) algorithm. The effectiveness of the proposed method is verified by the applications to a sandwich-type transducer and a dummy load. In addition, the impedance matching network is also designed by using the estimated equivalent circuit model.

Computation of the Mutual Radiation Impedance in the Acoustic Transducer Array: A Literature Survey

  • Paeng, Dong-Guk;Bok, Tae-Hoon;Lee, Jong-Kil
    • The Journal of the Acoustical Society of Korea
    • /
    • 제28권2E호
    • /
    • pp.51-59
    • /
    • 2009
  • Mutual radiation impedance becomes more important in the design and analysis of acoustic transducers for higher power, better beam pattern, and wider bandwidth at low frequency sonar systems. This review paper focused on literature survey about the researches of mutual radiation impedance in the acoustic transducer arrays over 60 years. The papers of mutual radiation impedance were summarized in terms of transducer array structures on various baffle geometries such as planar, cylindrical, spherical, conformal, spheroidal, and elliptic cylindrical arrays. Then the computation schemes of solving conventional quadruple integral in the definition of mutual radiation impedance were surveyed including spatial convolution method, which reduces the quadruple integral to a double integral for efficient computation.

광대역 초음파 변환기를 위한 전기 임피던스 정합 연구 (Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer)

  • 김건우;김기복;백광세
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 초음파탐상법을 이용하여 마이크로미터의 크기 작은 결함을 검출하기 위해서는 높은 공진주파수와 큰 분해능의 초음파 변환기가 필요하다. 초음파 변환기의 공진주파수와 분해능은 변환기에 사용된 압전소자의 두께, 후면재 및 탐상 시스템 간의 전기 임피던스 정합과 밀접한 관련이 있으며, 이 중 전기 임피던스 매칭은 초음파 변환기와 초음파탐상 시스템 사이의 서로 다른 입 출력단을 연결하는 과정에서, 두 연결단의 전기적 임피던스 차이에 의한 에너지 반사와 손실을 줄이는 중요한 역할을 한다. 임피던스 정합에서 흔히 많이 사용하는 방법은 LC-정합회로이다. 이러한 LC-정합을 통해 탐상 시스템과 초음파 변환기의 전기 임피던스를 $50{\Omega}$으로 맞추어 두 연결단 사이의 임피던스 차이를 보정해 줌으로서 초음파 변환기에서 발생되는 전기신호의 손실을 줄 수 있다. 본 연구에서는 15 MHz의 공진주파수를 가지는 광대역 수침형 초음파 탐촉자를 제작하고 광대역 특성을 갖는 초음파 변환기를 위한 LC 임피던스 정합법을 적용하였다.

미립자 집단 최적화 알고리즘을 이용한 다중모드 수중 음향 압전 트랜스듀서의 등가회로 모델링 (Equivalent Circuit Modeling of Multiple Modes Underwater Acoustic Piezoelectric Transducer Using Particle Swarm Optimization Algorithm)

  • 이정민;이병화;백광렬
    • 한국음향학회지
    • /
    • 제28권4호
    • /
    • pp.363-369
    • /
    • 2009
  • 본 논문에서는 인접된 다중모드 공진점을 갖는 수중 음향 압전 트랜스듀서의 전기적 등가회로 모델을 추정하는 방법을 제안하였다. 트랜스듀서의 실측된 임피던스와 추정된 등가모델의 임피던스 오차가 최소가 되도록 공진모드간 결합 영향을 고려한 적합도 함수를 제안하고, 미립자 집단 최적화 (PSO:Particle Swarm Optimization) 알고리즘을 이용하여 등가회로의 미지상수를 추정하였다. 3개의 공진점을 갖는 샌드위치형 예제 트랜스듀서에 대하여 제안된 방법을 적용하여 등가회로를 모델링하고, 수중에서의 임피던스 측정치와 추정된 등가모델의 임피던스를 비교함으로써 제안된 기법의 타당성을 검증하였다.

과실 비파괴평가용 초음파 변환기 개발 (Development of Ultrasonic Transducer for Nondestructive Evaluation of Whole Fruit)

  • 김기복;이상대;김만수
    • Journal of Biosystems Engineering
    • /
    • 제32권4호
    • /
    • pp.269-275
    • /
    • 2007
  • In this study, ultrasonic transducers for non-destructive contact measurement of whole fruits were developed. The design parameters for ultrasonic transducer such as acoustical impedance of fruits, kinds of piezoelectric materials, ultrasonic wave frequency, and transducer diameter were investigated. In order to match the acoustical impedance between piezoelectric material and fruit, various materials were fabricated and evaluated. Also to control the sensitivity and bandwidth of the ultrasonic transducer, various backing materials were fabricated and evaluated. Especially, the wear plate of the ultrasonic transducer was designed and fabricated considering the curvature of fruit. The central frequencies of two developed ultrasonic transducers were about 100 kHz and 200 kHz, respectively. With the developed ultrasonic transducers, non-destructive evaluation of the fruit will be possible.

유한요소법을 이용한 원통형 압전변환기의 입력임피던스 해석 (Input Impedance Analysis of Piezoelectric Cylinder Transducer using Finite Element Method)

  • 김천덕;서희선;김대환;윤종락
    • 한국음향학회지
    • /
    • 제11권6호
    • /
    • pp.32-40
    • /
    • 1992
  • This study shows how the finite element method for the structural problems could be applied in the electromechanical impedance analysis of an in-air piezoelectric cylinder transducer and then compares the numerical results by the FEM with the measured results using the impedance analyzer. The results also show that the comparison between both results could be applied to examine the mechanical properties of the added unknown material to transducer such as an acoustic window.

  • PDF

Power Transmission Determined by the Mutual Impedance and the Transducer Power Gain in the Near Field Region

  • Kim, Che-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.152-155
    • /
    • 2011
  • This paper describes the role of mutual impedance and the transducer power gain which comes from key parameters to determine the amount of wireless power especially in a near-field environment. These two key parameters are applied to the two configurations; one is a dipole-dipole, and the other is a dipole-metal plate-loop configuration. Discussions are given on the achievable maximum power transfer between the sender and the receiver affected by the matching and the pass blockage.

장방형 트랜스듀서의 자기방사 임피던스 계산 (Calculation of Self-radiation Impedance for a Rectangular Transducer)

  • 이기욱;김무준;하강열;김천덕
    • 한국음향학회지
    • /
    • 제19권7호
    • /
    • pp.85-89
    • /
    • 2000
  • 본 논문에서는 기 확립한 정방형 진동면의 수열을 사용한 자기 및 상호방사 임피던스 계산법을 확대 적용하여 임의정수의 종횡비를 갖는 장방형 트랜스듀서의 자기방사 임피던스 계산법을 제시하였다. 이 방법은 짧은 시간내에 비교적 정확한 계산 결과를 얻을 수 있는데, 분할한 음원요소의 수에 따른 계산정도 및 계산시간을 고찰한 후, 종횡비가 다른 몇몇 장방형 트랜스듀서의 자기방사 임피던스를 산출하여 기존의 문헌치와 비교하였다.

  • PDF