• Title/Summary/Keyword: Impedance frequency characteristics

Search Result 647, Processing Time 0.031 seconds

Frequency Controllable Ultrasonic knife and made by multi-layered PZT ultrasonic transducer (다층 압전진동자를 이용한 주파수 가변 초음파 메스의 개발)

  • 김무준;하강열
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.506-512
    • /
    • 1997
  • Ultrasonic knives have been successfully used for the surgery of many medical fields. However, the conventional ultrasonic knives for surgical operation cannot be controlled its resonant frequency. So if the material to cut has different characteristic impedance then different ultrasonic knife will be needed. Because the optimum driving frequency of ultrasonic knife is different by characteristic impedance of material. In this work, using a frequency variable ultrasonic transducer made of multi-layered PZT vibrator, a frequency controllable ultrasonic knife will be suggested. The design and computation principles will be also derived. For this work, firstly, the characteristics of this ultrasonic knife will be analyzed by transmission line model equivalent circuit, and the free admittance characteristics and vibrational velocity distributions will be obtained. Secondly, we will design and make the frequency controllable electrical oscillator for driving this ultrasonic knife.

  • PDF

Analysis of Frequency Response Characteristic Considering Semiconducting Screen in Underground Distribution Cables (지중배전케이블에서 반도전층을 고려한 주파수 응답 및 전파특성 분석)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1091-1098
    • /
    • 2012
  • This paper describes frequency response and propagation characteristics considering semiconducting screen in distribution cables. In CIGRE WG 21-05, Simplified Approach(SA) and Rigorous Approach(RA) which can revise the permittivity considering semiconducting screen propose for more detailed EMTP model and frequency dependant analysis. In this paper, the frequency dependent characteristics of complex permittivity are variously analysed by cole-cole function of RA. The attenuation, propagation velocity and surge impedance according to frequency range(1 kHz to 500 MHz) and cable length are also analysed by SA and EMTP simulation in distribution cables. The propagation velocity considering semiconducting screen is slower, and it is saturated over the range of 1 MHz. The signal is significantly attenuated as frequency range is high.

Analysis of Channel Noise and Impedance Characteristics for High-Speed Power-Line Communication (고속 전력선 통신을 위한 전력선채널 잡음 및 임피던스 특성 분석)

  • 김정훈;김선효;김상태;이영철;신철재
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.37-40
    • /
    • 2001
  • Subject of this paper is analysis of channel noise and impedance characteristics for high speed power line communication to concerned noise of transmission line and impedance in the frequency range up to 30MHz. Parameters of transmission line was inducted from experimentally power line channel measurement. Moreover, Analysis of compared based on measurement of channel characters with simulation test for appear characters.

  • PDF

Transient Impedance Characteristics of Grounding Rods (봉상접지극의 과도임피던스 특성)

  • 김일권;김점식;송재용;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.568-572
    • /
    • 2000
  • This paper describes the experimental results of a transient impedance characteristics of grounding rods to a square pulse and standard lightning impulse current. The test were performed on single grounding rod($\phi$ 10mm, 1m) and triple-grounding rods( $\phi$ 10mm, 1m) of equilateral triangles with 5m spacing. For measurements of transient impedance, a pulse generator which can produce square wave of 30ns rise time and 20U Pulse duration was designed and fabricated. In the experiment, transient impedance of the grounding systems have been investigated from the recorded potential and current waveforms. The results showed that the value of the transient impedance is quite higher than the stationary resistance, and provide useful information for the value of a grounding system considered transient characteristics under a high frequency condition such as lightning stokes and ground-fault.

  • PDF

Computation of Critical Length for Linear Grounding Electrodes (직선형 접지전극의 임계길이의 산정)

  • Kim, Ki-Bok;Lee, Bok-Hee;Joe, Jeong-Hyeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.67-74
    • /
    • 2009
  • For the surge currents like lightning currents containing high frequency components and the abnormal currents having high frequencies which cause the EMI(Electromagnetic interference) problems for the electronic devices and communication instruments, the linear grounding electrodes have the significantly composite impedance characteristics which are dependent on the frequency of the applied current. The impedance of a grounding electrode is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode having the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical length. In this paper, the critical lengths for the vertically and horizontally-buried grounding electrodes are calculated by using the distributed parameter circuit model. The propriety of the simulations has been confirmed by comparing the simulated results with the measured results.

RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module (TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선)

  • 이동수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.4
    • /
    • pp.8-12
    • /
    • 2003
  • Characteristics of optical transceiver module in radio frequency(RF) band were investigated with TO-can packaged Fabry-Perot laser diode(FP-LD). R-L-C parameters for equivalent circuit model of the LD were extracted with an impedance analyzer. With this model, impedance matching to the packaged LD could be performed by eliminating inductive components of the leads in the package by using lumped chip capacitors that have opposite reactance, while it shows resonance dip in low frequency band. The resonance dip could be removed using lumped elements for impedance matching by shifting the resonance frequency to the region out of interest.

Wideband Impedance Transformer Using a Coaxial Cable (동축선을 이용한 광대역 임피던스 트랜스포머)

  • Park, Ung-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.789-794
    • /
    • 2011
  • A coaxial-cable impedance transformer used in wideband frequency range is generally restricted to the fixed impedance transformation ratio as n2:1 or 1:n2(n: the number of coaxial cables). In this paper, we propose a new coaxial-cable impedance transformer to have an arbitrary impedance transformation ratio. We have fabricated three impedance transformers($50-{\Omega}$ to $25-{\Omega}$, $50-{\Omega}$ to $20-{\Omega}$ and $50-{\Omega}$ to $9-{\Omega}$) to confirm the operation characteristic of the suggested impedance transformer. The reflection characteristics (S11) of the fabricated $50-{\Omega}$ to $25-{\Omega}$ and $50-{\Omega}$ to $20-{\Omega}$ impedance transformer were less than -15dB over about 3-octaves frequency range and the reflection characteristic (S11) of the fabricated $50-{\Omega}$ to $9-{\Omega}$ impedance transformer was less than -15dB over about 1-octave frequency range, respectively.

Humidity Sensing Characteristics of TiO2 Thin Films Fabricated by R.F.Sputtering Method (R.F.스퍼터링법에 의해 제작된 TiO2 박막의 습도감지특성)

  • You, Do-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.974-979
    • /
    • 2013
  • $TiO_2$ thin films are fabricated using R.F.sputtering method. $TiO_2$ thin films are coated on $Al_2O_3$ substrate printed IDE(interdigitated electrode). Impedance of thin films decreases according to increase relative humidity and it increases according to decrease measuring frequency. When substrate temperature is room temperature, impedance of thin films is from 45.68[MHz] to 37.76[MHz] within the limits from 30[%RH] to 75[%RH] at 1[kHz]. Whereas when substrate temperature is 100[$^{\circ}C$], impedance of thin films is from 692[kHz] to 539[kHz] within the limits from 30[%RH] to 75[%RH] at 1[kHz]. Impedance variation of thin films is bigger in low frequency regions than in high frequency regions. When substrate temperature is 100[$^{\circ}C$], impedance of thin films is lower than that of room temperature.

Detection Algorithm and Characteristics on DC Residual Current based on Analysis of IEC60479 Impedance Model for Human Body (IEC60479 인체 임피던스 모델에 근거한 직류누설전류의 특성 및 검출 알고리즘)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.305-312
    • /
    • 2018
  • DC distribution systems has recently taken the spotlight. Concerns over human safety and stability facility are raised in DC distribution systems. Std. IEC 60479 provides basic guidance on "the effects of shock current on human beings and livestock" for use in the establishment of electrical safety requirements and suggests an electrical impedance of the human body. This study analyzes impedance spectrums based on the electrical equivalent impedance circuit for the human body; human body impedances measured by experiments are analyzed below the fundamental frequency (60 Hz). The analysis shows that the equivalent impedance circuit for the human body should be modified at least in low-frequency range below the fundamental frequency (60 Hz). The DC residual current detection method that can classify electric shock accidents of humans and electric leakages of facilities is proposed by applying the analysis result. The detection method is verified by experiments on livestock.

Transient Grounding Impedance Characteristics of a Concrete Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 콘크리트봉 접지전극의 과도 접지임피던스 특성)

  • Kim, Kyung-Chul;Kim, Jong-Uk;Lee, Kyu-Jin;Choi, Jong-Ki;Choi, Sun-Kyu;Kim, Dong-Myung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2010
  • Grounding insures a reference potential point for electric devices and also provides a law resistance path for fault or transient currents in the earth. The grounding impedance as a function of frequency is necessary for determining its performance since fault or transient currents could contain a wide range of frequencies. A concrete rod electrode is one of the commonly used grounding electrodes in electric distribution systems. In this paper, the grounding impedance of concrete rods has been measured in frequency raging from 60[Hz] up to 100[kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the EDSA software program.