• Title/Summary/Keyword: Impedance angle

Search Result 184, Processing Time 0.029 seconds

Full Bridge Resonant Inverter Using Asymmetrical Control with Resonant-frequency Tracking for Ultrasonic Cleaning Applications

  • Jittakort, Jirapong;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1150-1159
    • /
    • 2017
  • Flexibility in the power control of ultrasonic transducers has remained a challenge for cleaning applications. This paper introduces a modification of the existing piezoelectric ceramic transducer (PCT) circuit to increase the range of operation through its impedance characteristics. The output power is controlled using the asymmetrical voltage-cancellation (AVC) method. Together with a phase-locked loop control, the switching frequency of the inverter is automatically adjusted to maintain a lagging phase angle under load-parameter variations during the cleaning process. With the proposed modification, the region of the zero-voltage switching (ZVS) operation is extended, which results in a wider range of output power control. A hardware prototype is constructed and the control algorithm is implemented using an STM32F4 microcontroller. Simulation and experimental results are provided to verify the proposed method for a 50-W PCT. The operating frequency and output power ranges under study are 37 - 41 kHz and 15.8 - 50 W, respectively.

Haptic-Aided Design Using a Haptic Chair Capable of Adjustable Backrest (등판 조절이 가능한 햅틱의자를 이용한 햅틱 보조 설계)

  • Huh, Seok-Haeng;Lee, Sang-Duck;Song, Jae-Bok
    • The Journal of Korea Robotics Society
    • /
    • v.4 no.3
    • /
    • pp.243-249
    • /
    • 2009
  • In modern society, people spend most of their time on various types of chairs. However, it is not easy for a designer to design a comfortable chair because satisfaction with the chair depends not only on the quantitative elements such as size, but also on the qualitative element such as the user's feeling. To deal with these problems, there have been many studies on designing ergonomic chairs. This paper proposes the haptic-aided design (HAD) system to design an ergonomic chair. Based on the HAD system, the designer can experience whether the chair is comfortable or not through the haptic device, and also can modify the design parameters instantaneously. The haptic chair capable of controlling the design parameters in real time was proposed as a haptic simulator. The controllable parameters, such as seat height, reclining angle, stiffness of the backrest, and so on were selected based on the previous research related to ergonomic chairs. The proposed methodology will help reduce the development cost and time by replacing the process of making the real mock-ups and prototypes with the haptic chair.

  • PDF

Characteristics and Applications of the Tapered Feedline with Strong Coupling (강한 결합성을 갖는 테이퍼 라인을 이용한 공진기 급전선의 특성 및 응용)

  • 한상민;최준호;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.8
    • /
    • pp.878-883
    • /
    • 2003
  • New feeding structures using linearly and exponentially tapered lines to planar microstrip resonators are proposed. These can overcome the design problems from coupling losses and impedance mismatching by increasing the coupling efficiency. The variation of its feeding angle is evaluated for the insertion loss and bandwidth and the feedline length is optimized at ${\lambda}_g$/2. The ring resonators and patches fed by the tapered line have been designed and implemented. The experimental results show that the insertion loss is enhanced by about 7 dB. Both rings and antennas are better matched, without disturbing the single-mode resonance or distorting their radiation pattern

Application and Control of UPFC for Improving Power System Oscillation Damping (전력시스템 동요억제를 위한 UPFC 적용 및 제어)

  • Kim, Y.S.;Kim, T.J.;Lee, B.H.;Han, H.G.;Son, K.M.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1124-1126
    • /
    • 1997
  • The Unified Power Flow Controller(UPFC) with a series inverter and a shunt inverter ia able to control all three line Parameters(voltage, impedance and phase angle) and so UPFC technology has the potential to enhance the implementation and broad application of the FACTS concept with improved Performance. In this Paper, the UPFC is applied in order to improve the power flow oscillation damping. The modal performance measure is minimized in order to determine the optimal parameters of UPFC controller for damping Power flow oscillations. The dynamics of the injected voltage of UPFC is represented as a first order delay element. The UPFC controller used here is of the PIO type and the input signal to the controller is the active power flow through the UPFC. The effect of UPFC application to the Power system are analyzed from the stand point of power system oscillation damping.

  • PDF

Fabrication of dual mode ultrasonic transducers with PZT piezoelectric ceramics (PZT 압전 세라믹스를 사용한 2중 모우드 초음파 트랜스듀서 제작)

  • 김연보;노용래;남효덕
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.572-579
    • /
    • 1995
  • Most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigate the mechanism of dual mode transducers that generate both of the longitudinal and shear waves simultaneously with single PZT element. The study is aimed to find the optimally desired cut by examining the anisotropic piezoelectric properties. Theory predicts that a mixed P/S mode transducer can be constructed using a rotated Z-cut of PZT piezoelectric ceramics. We study the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves as much as equally strong. The results are verified by the waveform in pulse-echo computer simulation and experiments. When the transducer is subjected to impedance analysis, it shows two thickness mode resonances, each of which being a mixed P/S thickness mode. By examining wave speeds on E transmitter delay line receiver setup, it is confirmed that the transducer can transmit and detect both longitudinal and shear wave simultaneously.

  • PDF

An analysis of the relationship between the Cold pattern and Anthropometry, Bio Impedance Analysis (BIA) and Quality of Life in Jeju Haenyeo (제주 해녀의 한증과 인체측량, 생체전기임피던스 지표 및 삶의 질과의 연관성 분석)

  • Lee, Eunyoung;Kim, Sujung;Lee, Siwoo;Cha, Seongwon;Lee, Youngseop;Mun, Sujeong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.67-74
    • /
    • 2016
  • Objectives : The purpose of this study was to analyze the relationship between the Cold-pattern and the quantitative index through the results of an anthropometric method and Bio Impedance Analysis (BIA) of the Haenyeo living in Jeju island. Furthermore, we will examine the effect of Cold-pattern on the quality of life. Methods : BIA indices were acquired directly from Inbody770 and questionnaires were collected by Gallup Korea professional surveyor through face to face interviews. Binary regression analysis and linear regression analysis were used to examine the association between collected data. Results : Total of 175 of people were participated in this study. First, we examined the difference of the indicators in the Cold-pattern group and the non-Cold pattern group by the average comparison of the anthropometry and BIA indices. Most of the non-Cold pattern group showed high quality of life, BIA and anthropometry. In the relationship between Cold-pattern and anthropometry and BIA indices, BMI and PA indices were found to affect the Cold-pattern on a group basis. As the BMI increased by $1kg/m^2$, probability of not being non-Cold pattern was 1.13 times. and as the PA increased by $1^{\circ}$, probability of not being non-Cold pattern was 2.4 times. In the case of EQ5D value, the quality of life of ${\beta}$ was increased by 0.08 in non-Cold pattern (p <.05), EQ5D VAS of ${\beta}$ was also increased by 10.05 (p <.05). Conclusions : This study showed that BMI and PA could be used as a clinical index to evaluate the Cold-pattern as a clinical indicator, and there is a difference in quality of life according to Cold-pattern.

A Ku-Band Reduced Height Waveguide to Microstrip Mode Converter with a Short Transition Length (짧은 천이길이를 갖는 Ku-대역 감소단축도파관 대 마이크로스트립 모드 변환기)

  • Oh, Hyun-Seok;Yeorn, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1435-1444
    • /
    • 2008
  • In this paper, we designed a reduced height waveguide(WG) to microstrip mode converter with a short transition length. The mode converter is composed of a mode converter using E-plane probe and a modified impedance transformer. The mode converter was designed using a probe shorted to top of a 50 ohm ridge WG. The modified impedance transformer was designed to connect the mode converter to the reduced height WG. For wide bandwidth operation, the coupling of the two parts was tuned. The structure of the mode converter was optimized for low loss and wide bandwidth, and the optimized mode converter was fabricated. The performance of the mode converter was extracted using the thru and line S-parameters for back-to-back connections, and the connector loss was calibrated. The mode converter has a right angle structure and short transition length, 7.2 mm. The mode converter shows excellent performances; the insertion loss of 0.12 dB at 15 GHz, and the return loss above 10 dB for the full Ku-band.

Electrical Resistivity of ITZ According to the Type of Aggregate (골재 종류별 시멘트 경화체 계면의 전기저항 특성)

  • Kim, Ho-Jin;Bae, Je Hyun;Jung, Young-Hoon;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.268-275
    • /
    • 2021
  • The three factors that determine the strength of concrete are the strength of cement paste, aggregate and ITZ(Interfacial Transition Zone) between aggregate and cement paste. Out of these, the strength of ITZ is the most vulnerable. ITZ is formed in 10~50㎛, the ratio of calcium hydroxide is high, and CSH appears low ratio. A high calcium hydroxide ratio causes a decrease in the bond strength of ITZ. ITZ is due to further weak area. The problem of ITZ appears as a more disadvantageous factor when it used lightweight aggregate. The previous study of ITZ properties have measured interfacial toughness, identified influencing factors ITZ, and it progressed SEM and XRD analysis on cement matrix without using coarse aggregates. also it was identified microstructure using EMPA-BSE equipment. However, in previous studies, it is difficult to understand the microstructure and mechanical properties. Therefore, in this study, a method of measuring electrical resistance using EIS(Electrochemical Impedance Spectroscopy) measuring equipment was adopted to identify the ITZ between natural aggregate and lightweight aggregate, and it was tested the change of ITZ by surface coating of lightweight aggregate with ground granulated blast furnace slag. As a result, the compressive strength of natural aggregate and lightweight aggregate appear high strength of natural aggregate with high density, surface coating lightweight aggregate appear strength higher than natural aggregate. The electrical resistivity of ITZ according to the aggregate appeared difference.

RF Gas Sensor Using 4-Port Hybrid Coupler with Conducting Polymer (전도성 고분자 물질이 결합된 하이브리드 커플러를 적용한 RF 가스 센서)

  • Lee, Yong-Joo;Kim, Byung-Hyun;Lee, Hee-Jo;Hong, Yunseog;Lee, Seung Hwan;Choi, Hyang Hee;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • In this paper, a gas sensor using a modified $90^{\circ}$ hybrid coupler structure with conducting polymer which operates at 2.4 GHz is represented. Conducting polymers are used to the gas sensing material in proposed sensors. The conducting polymer varies its electrical property, such as work function and conductivity corresponding to the certain gas. To verify this variation of electrical property of conducting polymer at microwave frequencies, the conducting polymer is incorporated with the $90^{\circ}$ hybrid coupler structure, and this proposed sensor operates as reflection type variable attenuator and variable phase shifter. The conducting polymer is employed as impedence-variable transmission lines that cause a impedance mismatching between the general transmission line and conducting polymer. The experiment was conducted with 100 ppm ethanol gas at temperature of $28^{\circ}C$ and relative humidity of 85 %. As a result, the amplitude deviation of $S_{21}$ is 0.13 dB and the frequency satisfying ${\angle}S_{21}=360^{\circ}$ is shifted about 2.875 MHz.

Analysis of Current Limiting Characteristics According to Fault Angles in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (일체화된 삼상 자속구속형 고온초전도 전류제한기의 사고각에 따른 전류제한 특성 분석)

  • Park, Chung-Ryul;Du, Ho-Ik;Yim, Seong-Woo;Hyun, Ok-Bae;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.255-256
    • /
    • 2006
  • In this paper, we investigated the. characteristics of fault current limiting according to fault angle in the integrated three-phase flux-lock type SFCL in fault types such as the single-line-to-ground fault, the double-line-to-ground fault and the three-line-to-ground fault. When the SFCL is operating under normal condition, the magnetic flux generated between primary and secondary coils of each single phase is canceled out perfectly, so that the impedance of the SFCL is also not generated and the power system can be operated normally without any loss, However, if a fault occurs even in any phase out of three phases, quench happened in SFCL elements and the current flowing secondary coil is restricted abruptly. Finally, the balance of magnetic flux in whole SFCL system is destroyed, and the fault currents in every phase could be limited at the same time irrespective of the fault types. As a result, the developed SFCL in this study were operated normally as expected and the purpose of the integration of 3 phase current limiting was also achieved successfully. However, the fault current limiting characteristics of the SFCL was dependant on the quench characteristics of HTSC elements in each phase, and it was expected that the improvement of the SFCL could be possible through the introduction of HTSC elements which have better critical characteristics.

  • PDF