• Title/Summary/Keyword: Impedance Meter

Search Result 61, Processing Time 0.023 seconds

A study on the pulp response of posterior composite resins in relation to the thickness of remaining dentin (잔존상아질 후경에 따른 구치용 복합레진의 치수반응에 관한 연구)

  • Ahn, Sang-Hun
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.265-282
    • /
    • 1988
  • The pulp response of posterior composite resins in relation to the thickness of remaining dentin was studied with 120 teeth from 6 dogs, Class V. cavities were prepared on the cervical area of facial surfaces. The thickness of remaining dentin was controlled with Caries Meter$^{(R)}$. The cavities of group A were prepared to show the electrical impedance of 22-26$K{\Omega}$(thickness of remaining dentin:0.4-0.5mm). The cavities of group B, 50-55$K{\Omega}$(thickness of remaining dentin: 0.8-0.9mm). Zinc - Oxide Eugenol cement, Estilux$^{(R)}$ posterior, Heliomolar$^{(R)}$ radiopaque, P-30$^{(R)}$ and Scotchbond$^{(R)}$+P-30$^{(R)}$ were filled in each cavity. After 3days, 1 week, 2 weeks, 4 weeks, 9 weeks and 13 weeks, the teeth and pulp tissue were processed routinely and stained with Hematoxylin and Eosin. Pathological tissue changes were observed with light microscope. The following results were obtained. I. The pulp response of group A cavties was severer than that of group B cavities. 2. In the pulp of group A cavities which were filled with Zinc-Oxide Eugenol Cement, only vascular changes were observed after 3 days and 1 week, severe acute inflammation after 4 weeks, moderate acute inflammation after 9 weeks, and chronic inflammation and formation of granulation tissue after 13 weeks. 3. In the pulp of group A cavities which were filled with Estilux$^{(R)}$ posterior, only vascular changes were observed after 3 days and 1 week. But the inflammatory response has became much severer with the elapsed experimental period. 4. In the pulp of group A cavities which were filled with Heliomolar$^{(R)}$ radiopaque, the inflammatory response with the elapsed experimental period was not severer than that of the pulp of group A cavities which were filled with other materials. 5. In the group B cavities, the difference of pulp response by filling materials was not recognizable. In the group A cavities, the pulp response of Estilux$^{(R)}$ posterior was severest and in order P-30$^{(R)}$, Heliomolar$^{(R)}$ radiopaque was slighter.

  • PDF

(1-x)$(Na_{0.5}K_{0.5})NbO_3-xLiNbO_3$ 무연 압전세라믹스의 첨가물질에 따른 전기적 특성 평가

  • U, Deok-Hyeon;Ryu, Seong-Rim;Yun, Man-Sun;Gwon, Sun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.260-260
    • /
    • 2007
  • 강유전성 세라믹스 재료로써는 PZT계열의 세라믹재료가 널리 쓰이고 있다. 이는 우수한 유전 및 압전특성을 가지고 있으나, PbO을 다량 함유하고 있어 $1000^{\circ}C$이상에서 PbO가 급격하게 휘발되는 성질에 따라서 조성의 변동이 생겨 재현성이 어려우며 이를 방지하기 위하여 과잉 PbO를 첨가시키기 때문에 PbO휘발로 인한 강한 독성이 인체에 유해하다. 최근에는 Pb의 환경문제가 대두됨에 따라 이를 대체할 다른 물질의 개발이 활발하게 연구되고 있다. 대표적인 비납계 강유전 세라믹스인 $(Na_{0.5}K_{0.5})NbO_3$ ($d_{33}$ = 120 pC/N, Kp = 39%, Qm = 210, 이하 NKN라 표기) 조성은 $KNbO_3,\;NaNbO_3$ 상태도에 따라 순수한 NKN 세라믹스는 $1140^{\circ}C$에서 안정상을 가지나, 높은 온도로 인하여$Na_2O$$K_2O$가 쉽게 휘발됨에 따라 화학량 비의 변화가 생겨 이차 상을 형성하기도 한다. 따라서 본 연구에서는 $LiNbO_3$의 새로운 고용체를 추가시켜 기본 NKN조성에 압전성 및 고온에서의 상안정성을 향상시키고자 하였다. 최적 조성을 설계하기 위하여 (1-x)$(Na_{0.5}K_{0.5})NbO_3-xLiNbO_3$, x=(0,0.02,0.04,0.06,0.08)의 범위에서 조성을 변화시키면서 실험하였다. 시편 제작은 일반적인 세라믹스 소결 공정을 적용하였는데, $850^{\circ}C$에서 5시간 하소 후 $1080^{\circ}C$에서 2시간 소결하였다. 하소 및 소결 후에는 XRD분석을 통해 perovskite구조를 확인하였고, 미세구조 확인을 위해 주사전자현미경 (SEM)으로 관찰하였다. 압전특성을 평가하기 위해 압전 $d_{33}$-meter를 사용하였으며, impedance analyzer (HP 4194A)를 이용하여 전기적 특성을 측정하였다.

  • PDF

Prevalence of dynapenic obesity and sarcopenic obesity and their associations with cardiovascular disease risk factors in peritoneal dialysis patients

  • Tabibi, Hadi;As'habi, Atefeh;Najafi, Iraj;Hedayati, Mehdi
    • Kidney Research and Clinical Practice
    • /
    • v.37 no.4
    • /
    • pp.404-413
    • /
    • 2018
  • Background: Dynapenic obesity and sarcopenic obesity increase cardiovascular disease (CVD) and mortality in nonuremic patients. The present study was designed to determine the prevalence of dynapenic obesity and sarcopenic obesity and their associations with CVD risk factors in peritoneal dialysis (PD) patients. Methods: All eligible PD patients in Tehran peritoneal dialysis centers were included in this cross-sectional study. Skeletal muscle mass and fat mass were assessed using bioelectrical impedance analysis. Muscle strength and physical performance were determined using hand grip strength and a 4-meter walk gait speed test, respectively. In addition, a 5-mL blood sample was obtained from each patient. Results: The prevalence of dynapenic obesity and sarcopenic obesity were 11.4% and 3.8% in PD patients, respectively. Serum high-sensitive C-reactive protein (hs-CRP), soluble intercellular adhesion molecule type 1, triglyceride, total cholesterol, and low-density lipoprotein cholesterol were significantly higher in PD patients with dynapenic obesity than in dynapenic nonobese and nondynapenic nonobese patients. Similarly, serum concentrations of CVD risk factors in PD patients with sarcopenic obesity were higher than in nonsarcopenic nonobese patients, but these differences were statistically significant only for serum hs-CRP and triglyceride. In addition, muscle strength and skeletal muscle mass percentage were negatively associated with markers of inflammation and dyslipidemia, whereas body fat percentage was positively associated with these CVD risk factors. Conclusion: This study indicates that although the prevalence of dynapenic obesity and sarcopenic obesity are relatively low in PD patients, these disorders may be associated with CVD risk factors.

An Experiment and Analysis for Standardize Measurement on CCFL (냉음극 형광램프의 표준화 계측을 위한 실험과 분석)

  • Jin, Dong-Jun;Jeong, Jong-Mun;Jeong, Hee-Suk;Kim, Jin-Shon;Lee, Min-Kyu;Kim, Jung-Hyun;Koo, Je-Huan;Gwon, Gi-Cheong;Kang, June-Gill;Choi, Eun-Ha;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.331-340
    • /
    • 2008
  • A method of measuring the current and voltage is suggested in the circuit of cold cathode fluorescent lamps (CCFLs) which are driven at a high frequency of $50{\sim}100\;kHz$ and a high voltage of several kV. It is difficult to measure the current and voltage in the lamp circuit, because the impedance of the probe at high voltage side causes the leakage current and the variation of luminance. According to the analysis of equivalence circuit with the probe impedance and leakage current, the proper measuring method is to adjust the input DC voltage and to keep the specific luminance when the probe is installed at a high voltage circuit. The lamp current is detected with a current probe or a high frequency current meter at the ground side and the voltage is measured with a high voltage probe at the high voltage side of lamp. The lamp voltage($V_C$) is measured between the ballast capacitor and the lamp electrode, and the output voltage($V_I$) of inverter is measured between inverter output and ballast capacitor. As the phases of lamp voltage($V_C$) and current ($I_G$) are nearly the same values, the real power of lamp is the product of the lamp voltage($V_C$) by the lamp current($I_G$). The measured value of the phase difference between inverter output voltage($V_I$) and lamp current($I_G$) is appreciably deviated from the calculated value at $cos{\theta}=V_C/V_I$.

The Association between Total Body Fat and Serum Lipids Concentrations in College Students (대학생에서 혈액 지질 수준과 체지방과의 관련성)

  • Lee, Jun-Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.233-238
    • /
    • 2017
  • This study was conducted to investigate the relationship between body fat content and serum lipids in college students. A total of 61 (15 males and 46 females) students of W university in Iksan, between June 2015 and July 2015, were enrolled for analysis. The relationship of serum lipid with BMI, and body fat percent measured by impedance fat meter (InBody 520) was analyzed. The study population was divided into three groups according to the InBody 520's guideline. Group I accounted for 26.7% of men and 10.9% of women. Weight and BMI were significantly different among the three groups in men and women (p<0.05); whereas height was not. In men, serum total cholesterol, triglyceride, low density lipoprotein cholesterol, and hemoglobin were significantly different between the three groups (p<0.05). Conversely, in women, serum total cholesterol, low density lipoprotein cholesterol, and alanine transferase were significantly different between the three groups (p<0.05). However, there were no differences in other variables between the three groups. BMI was significantly different among three groups in both men and women (p<0.05). In men and women, body fat percent was correlated with BMI, weight, total cholesterol, and low density lipoprotein cholesterol. Multiple regression analysis on total cholesterol indicates that body fat percent, BMI, and hemoglobin were not significantly independent variables in men and women. This study showed that body fat percent was significantly associated with other obesity markers and serum lipids.

Body Fat Percent and Serum Lipid Level of School Children by Obesity Index (대구지역(大邱地域) 일부(一部) 국민학교(國民學校) 아동(兒童)의 비만도별(肥滿度別) 체지방(體脂肪) 비율(比率)과 혈청지질치(血淸脂質値))

  • Kim, In-Sook;Lee, Kyeong-Soo;Kang, Pock-Soo
    • Journal of the Korean Society of School Health
    • /
    • v.7 no.2
    • /
    • pp.125-133
    • /
    • 1994
  • This study was conducted to identify the relationship between body fat percent/serum lipid level and obesity index among school children. The study subjects were 277 boys and 266 girls aged between 10 and 11 years old in a selected elementary school in Taegu City. The survey was conducted for the period of two months from May 1 to June 30, 1993. A $R{\ddot{o}}hrer$index(weight/height3) was calculated for each individual as a measure of obesity. Three groups were classified as underweight($R{\ddot{o}}hrer$ index < 109), normal($109{\leq}$ $R{\ddot{o}}hrer$ index < 140), and overweight ($R{\ddot{o}}hrer$ index ${\geq}140$). As for the body fat percent, fat weight, lean body mass were measured by impedance fat, meter(Model SIF-891). Serum total cholesterol. high-density lipoprotein, and triglyceride were measured by automated clinical chemistry analyzer(Astra system). Obesity was found 18.1% in boys and 14.7% in girls. Body weight, fat percent, fat weight, and lean body mass were significantly different among three groups classified by $R{\ddot{o}}hrer$ index in both sexes. Serum total cholesterol, triglyceride, atherogenic index and T-CHO/HDL ratio were also significantly different among three groups in both sexes. Serum total cholesterol, low-density lipoprotein, trigylceride, atherogenic index of boys were positively correlated with height, weight. $R{\ddot{o}}hrer$ index, fat weight, lean body mass, and triglyceride. The negative correlation was found in high-density lipoprotein against height, weight, Rohrer index, fat percent, fat weight, lean body mass. Triglyceride and atherogenic index of the girls were positively correlated with height, weight, $R{\ddot{o}}hrer$ index, fat percent, fat weight, lean body mass. The negative correlation was found in high-density lipoprotein against height, weight, $R{\ddot{o}}hrer$ index, fat percent, fat weight, lean body mass. These findings suggest that the prevention of obesity and hyperlipidemia among school children is very important. Thus adoption of healthy life-style is strongly recommended in school health programs in order to prevent the obesity and hyperlipidemia.

  • PDF

Electrical Properties of Piezoelectric Generator Fabricated with PNN-PZT Ceramic (PNN-PZT 압전 세라믹을 이용하여 제작한 발전소자의 전기적 특성 평가)

  • Lee, Myung-Woo;Kim, Sung-Jin;Yoon, Man-Soon;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.190-190
    • /
    • 2008
  • 자연적으로 발생되는 파도, 비, 우박 등과 철도, 차량 및 엘리베이터 등과 같은 인위적인 설치, 이동에 의해 발생되는 진동에너지는 우리 일상생활에서 가장 흔하게 발생할 수 있는 에너지원인데, 이러한 진동에너지는 압전 소재를 이용하여 재생 가능하여 최근에는 이에 대한 연구가 활발히 진행되어 왔다. 예를 들면, 미국의 MIT에서는 인간이 걸을 때 신발에 가해지는 압력을 이용하여 전력을 발생시키는 연구를 진행하여 2.9 mW의 전력을 얻었다. 특히 이러한 기술은 인간의 걷기 운동 등과 같은 일상적인 동작으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수가 있어서, 소형 전자기기 등에 서 기존 이차전지를 대체 또는 보완 할 수 있는 기술로 검토되고 있다. PZT계 세라믹스는 높은 유전상수와 우수한 압전특성으로 이러한 압전발전 분야에서 가장 널리 사용되어지고 있다. 하지만 에너지 효율을 높이기 위하여 적층 구조의 제작 시 구조적 특성상 내부전극이 도포된 상태에서 동시 소결이 필요한데, $1000^{\circ}C$ 이상의 높은 소결온도 때문에 소재 원가가 낮은 Ag전극 대신 값비싼 Pd나 pt가 다량 함유된 Ag/Pd, Ag/Pt 전극이 사용되고 있어 경제성이 떨어지는 단점을 갖게 된다. 순수 Ag 전극을 사용하거나 Ag의 비율이 높은 내부전극을 사용하기 위해서는 $900^{\circ}C$ 이하에서 소결되고 우수한 전기적 특성을 보이는 압전 세라믹스 소재를 개발 하는 것이 필요하다. 따라서 본 연구에서는 압전특성이 우수한 $(Pb_{1-x}Cd_x)(Ni_{1/3}Nb_{2/3})_{0.25}(Zr_{0.35}/Ti_{0.4})O_3$ 계의 조성을 설계하고, 소결온도를 낮추기 위해서 2 단계 하소법을 이용하였다. 또한 $MnCO_3$, $SiO_2$, $Pb_3O_4$ 등을 소랑 첨가하여 액상 소걸 특성을 부여하여 소결 온도를 감소시키려는 시도도 하였다. 소결체의 전체적인 제조 공정은 일반적인 벌크 세라믹의 소걸 공정을 따랐다. 최종 소결된 시편을 XRD분석을 통하여 상을 확인하였고 SEM을 이용하여 미세조직을 관찰 하였다. 전기적 특성을 평가하기 위하여 두께를 1mm로 연마한 시편에 Ag 전극을 도포하여 $650^{\circ}C$ 에서 열처리한 후, 분극처리 하였다. Impedance analyzer를 이용하여 압전 특성 (전기기계결합계수 및 기계적품질계수)을 측정 하였고, 압전전하상수는 $d_{33}$-meter로 측정하였다. 본 연구에서는 압전체에 가해지는 하중의 크기, 시편의 크기, 하중을 가하는 방법, 에너지 저장회로의 최적화 등을 다양하게 시도하면서 에너지 변환 및 저장 효율을 평가하였다.

  • PDF

Low Temperature Sintering of PNN-PZT Ceramic for Piezoelectric Generator and Its Piezoelectric Properties (압전 발전시스템 개발을 위한 PNN-PZT 세라믹스의 저온소결 및 압전특성 평가)

  • Lee, Myung-Woo;Kim, Sung-Jin;Yoon, Man-Soon;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.306-306
    • /
    • 2008
  • 기계적 에너지를 전기적 에너지로 변환하는 에너지 변환소자인 압전 세라믹스는 액추에이터, 변압기, 초음파모터, 초음파 소자 및 각종 센서로 응용되고 있으며, 그 응용분야는 크게 증가하고 있다. 최근에는 이러한 압전 소자를 앞으로 도래하는 ubiquitous, 무선 모바일 시대의 휴대용 전자제품, robotics, MEMS 분야 등의 대체 에너지원으로 응용하기 위한 연구가 진행되고 있다. 특히 인간의 걷기 운동 등과 같은 일상적인 동작으로 필요한 전력을 얻을 수 있고, 세라믹 소자를 이용하기 때문에 전자노이즈가 발생되지 않을 뿐 아니라 반영구적으로 사용할 수 가 있어서, 기존 이차전지를 대체 또는 보완 할 수 있는 방안도 검토되고 있다. PZT계 세라믹스는 높은 유전상수와 우수한 압전특성으로 전자세라믹스 분야에서 가장 널리 사용되어지고 있지만 $1200^{\circ}C$ 이상의 높은 소결온도 때문에 $1000^{\circ}C$ 부근에서 급격히 휘발되는 PbO로 인한 환경오염과 기본조성의 변화로 인한 압전 특성의 저하가 문제시 되고 있다. 또한 적층 세라믹스의 제작 시 구조적 특성상 내부전극이 도포된 상태에서 동시 소결이 필요한데, 융점이 낮은 Ag전극 대신 값비싼 Pd나 Pt가 다량 함유된 Ag/Pd, Ag/Pt 전극이 사용되고 있어 경제성이 떨어지는 단점을 갖게 된다. 순수 Ag 전극을 사용하거나 Ag의 비율이 높은 내부전극을 사용하기 위해서는 $900^{\circ}C$ 이하에서 소결되고 우수한 전기적 특성을 보이는 압전 세라믹스를 개발 하는 것이 필요하다. 따라서 본 연구에서는 압전특성이 우수한 $(Pb_{1-x}Cd_x)(Ni_{1/3}/Nb_{2/3})_{0.25}(Zr_{0.35}/Ti_{0.4})O_3$ 계의 조성을 설계하고, 소걸온도를 낮추기 위해서 2 단계 하소법을 이용하였다. 또한 $MnCO_3$, $SiO_2$, $Pb_3O_4$ 등을 소량 첨가하여 액상 소결 특성을 부여하여 소결 온도를 감소시키려는 시도도 하였다. 분말을 볼 밀링 (ball milling)을 통해 24시간 동안 혼합하고, 혼합된 분말은 $800^{\circ}C$에서 2시간 동안 하소하였다. 하소한 분말을 다시 72시간 동안 볼 밀링 하여 최종 분말을 얻었다. 최종 분말에 PVB를 첨가하여 직경 15mm의 디스크 형태로 성형한 후, 850~$975^{\circ}C$ 범위에서 온도를 변화시키면서 소결을 하였다. 최종 분말 및 소결된 시편을 XRD분석을 통하여 상을 확인하였고, SEM을 이용하여 미세조직을 관찰 하였다. 전기적 특성을 평가하기 위하여 두께를 1mm로 연마한 시편에 Ag 전극을 도포하여 $650^{\circ}C$에서 열처리한 후, 분극처리 하였다. 압전특성은 $d_{33}$-meter로 측정하였고, impedance analyzer를 이용하여 압전 특성 (전기기계결합계수 및 기계적품질계수)을 측정 하였다. 또한 강유전체 특성 평가 장치 (Precision-LC)를 이용하여 분극-전계 특성을 평가하였다. 이상의 연구를 통하여 소결 온도가 $900^{\circ}C$인 경우에서도 양호한 압전 특성을 확보 할 수 있었다.

  • PDF

The effect of Park Golf exercise on body composition and sleep of the elderly (파크골프운동이 노인의 신체구성 및 수면에 미치는 영향)

  • Choe, Myouung-Ja
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1529-1536
    • /
    • 2012
  • The purpose of this study is the investigation of park golf exercise impact on body composition and sleep. Measuring body composition was using multi-frequency impedance meter (Inbody720) for the Weight,% Body Fat, BMI, WHR. And there was using Oh,jinju(1998) as a measurement tool for sleep. Looking at changes in body composition, In the experimental groups, before the experiment body weight $60.56{\pm}6.25kg$, BMI $25.40{\pm}12.4kg/m^2$, %BodyFat $36.46{\pm}4.67%$, WHR $0.93{\pm}0.17$, after 12weeks, weight $58.3{\pm}7.16kg$, BMI $24.28{\pm}2.32kg/m^2$, %BodyFat $35.1{\pm}3.02%$, WHR $0.92{\pm}0.16$ as a significant decrease(p <.05) have appeared. After conducting an exercise program, experimental sleep score increased from 42.03 to 47.43 (increased 5.37) and control group increased from 42.48 to 43.4(increased 0.94). Between the two groups were statistically significant differences. In this study, performed 12weeks of the park golf exercise has a positive effect on body composition and sleep of the elderly.

A Study On Design of ZigBee Chip Communication Module for Remote Radiation Measurement (원격 방사선 측정을 위한 ZigBee 원칩형 통신 모듈 설계에 대한 연구)

  • Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.18 no.4
    • /
    • pp.552-558
    • /
    • 2014
  • This paper suggests how to design a ZigBee-chip-based communication module to remotely measure radiation level. The suggested communication module consists of two control processors for the chip as generally required to configure a ZigBee system, and one chip module to configure a ZigBee RF device. The ZigBee-chip-based communication module for remote radiation measurement consists of a wireless communication controller; sensor and high-voltage generator; charger and power supply circuit; wired communication part; and RF circuit and antenna. The wireless communication controller is to control wireless communication for ZigBee and to measure radiation level remotely. The sensor and high-voltage generator generates 500 V in two consecutive series to amplify and filter pulses of radiation detected by G-M Tube. The charger and power supply circuit part is to charge lithium-ion battery and supply power to one-chip processors. The wired communication part serves as a RS-485/422 interface to enable USB interface and wired remote communication for interfacing with PC and debugging. RF circuit and antenna applies an RLC passive component for chip antenna to configure BALUN and antenna impedance matching circuit, allowing wireless communication. After configuring the ZigBee-chip-based communication module, tests were conducted to measure radiation level remotely: data were successfully transmitted in 10-meter and 100-meter distances, measuring radiation level in a remote condition. The communication module allows an environment where radiation level can be remotely measured in an economically beneficial way as it not only consumes less electricity but also costs less. By securing linearity of a radiation measuring device and by minimizing the device itself, it is possible to set up an environment where radiation can be measured in a reliable manner, and radiation level is monitored real-time.