• 제목/요약/키워드: Impedance Curve

검색결과 135건 처리시간 0.027초

$Al_2O_3$조성변화에 따른 YIG의 주파수 및 자기특성 (The frequency and magnetic characteristics of YIG with the variation of $Al_2O_3$ additions)

  • 홍기원;김명호;장경욱;이준웅
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권6호
    • /
    • pp.787-794
    • /
    • 1995
  • To improvement the magnetic and frequency properties of YIG(Yttrium-Iron Garnet) in microwave region, it is investigated that the effect of $Al^{3+}$ ions on magnetic and frequency characteristics of YIG, using samples of basic YIG composition( $Y_{3}$F $e_{5}$ $O_{l2}$) added with A1$_{2}$ $O_{3}$ from 0 to 2.5 [mol%]. The measurment is conducted mainly for the structural properties and magnetical properties. The structural properties is measured using SEM(Scanning Electro Microscope), EDX(Energy-dispersive X-ray spectrometer) and XRD(X-ray diffraction equipment). The magnetical properties is measured with B-H curve tracer and impedance analyzer. As a result, it is confin-ned that the effect of eddy current loss is minimized while maintaining high saturation flux density of YIG, when YIG is added with 0.5 [mol%] of A1$_{2}$ $O_{3}$.>.>.

  • PDF

동잡음 저감을 위한 심전도 전극 특성에 대한 연구 (Study on Characteristics of ECG Electrodes for Motion Artifact Reduction)

  • 강영환;박재순;조범기;최상동;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

결함 접지 구조를 이용한 새로운 5-단 저역 통과 여파기 (A New Type of 5-Pole Low Pass Filter Using Defected Ground Structure)

  • 임종식;김철수;안달;정용채;남상욱;김광수
    • 한국전자파학회논문지
    • /
    • 제16권6호
    • /
    • pp.594-602
    • /
    • 2005
  • 본 논문에서는 결함 접지 구조(Defected Ground Structure, DGS)를 이용하여 설계한, 전송 선로의 폭이 매우 넓어진 새로운 형태의 5-단 저역 통과 여파기(5-pole Low Pass Filters, LPF)를 제시한다. 이를 위하여 종래에 제시 되었던 3-단 DGS LPF설계 방법을 임의의 N-단 LPF설계에도 적용할 수 있도록 일반화 시키고$(N\geq5)$, 한 예로써 5-단 LPF를 설계 및 측정 결과가 제시된다. LPF원형 회로로부터 필요한 소자값들을 갖는 서로 다른 크기의 DGS를 결정하기 위하여, 매우 정확한 인덕턴스 값을 예측해 주는 곡선 맞춤(curve-fitting) 방법도 제시되었다. 제안하는 5-단 LPF는 병렬 캐패시턴스 구현을 위해 개방 스터브 대신 선폭이 크게 보상된 낮은 임피던스의 전송 선로를 갖는다. 따라서 개방 스터브를 사용할 때 필수적으로 요구되는 T-나 Cross-불연속 접합 소자가 없고, 또한 기존의 LPF에서 직렬 인덕턴스 때문에 필요했던 높은 임피던스 전송 선로가 없다.

인체 흉부 영상 복원을 위한 행렬 적응 조정 방법의 적용 (Application of Matrix Adaptive Regularization Method for Human Thorax Image Reconstruction)

  • 전민호;김경연
    • 전기전자학회논문지
    • /
    • 제19권1호
    • /
    • pp.33-40
    • /
    • 2015
  • 전기 임피던스 단층촬영법(EIT)에서 역문제는 매우 높은 비정치성이므로 이것을 완화시키기 위해서 사전정보가 사용되고 EIT 역문제를 푸는 과정에서 만족스러운 복원성능을 갖기 위해 조정 기법은 적용된다. 반복적 Gauss-Newton 방법은 정확성과 빠른 수렴속도로 인해서 일반적으로 역문제를 푸는데 사용되지만 항상 좋은 성능을 내는 것은 아니며 조정 인자 선택에 따라 성능이 좌지우지된다. 비록 L-곡선과 같이 조정 인자를 결정하는데 이용할 수 있는 여러 가지 방법들이 존재하지만 이러한 방법들이 모든 경우에 적용할 수 있는 것은 아니다. 게다가 조정 인자는 스칼라이고 반복 연산동안 변하지 않는다. 그러므로 이 논문에서는 복원 성능을 향상시키기 위해서 조정 인자를 결정해주는 새로운 방법을 사용하였다. 각각의 반복 연산과정에서 도전율의 norm을 구하고 이것을 대각 행렬형태인 조정 인자를 구하는데 사용한다. 제안한 방법을 인체 흉부 영상 복원에 적용하였고, 기존의 방법들과 복원 성능을 비교하였다. 모의실험 결과, 기존의 방법들과 비교해서 개선된 성능을 확인할 수 있었다.

Electrical Charateristics of Step-down Piezoelectric Transformer

  • Shin Hoonbum;Ahn HyungKeun;Han Deuk-Young
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.47-51
    • /
    • 2001
  • In this paper, we have explained electrical characteristics of a step-down Rosen type piezoelectric transformer for AC-adapter. When the electric voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, then output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. From the piezoelectric direct and converse effects, symbolic expressions between the electric inputs and outputs of the step-down piezoelectric transformer have derived with an equivalent circuit model. With the symbolic expressions, load and frequency characteristics have discussed through simulation. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformers were measured under the various conditions of loads and frequencies. First we measured resonant frequency from impedance curve and got equivalent impedance value of the piezoelectric transformer from admittance plot. It was shown from experiments that output voltage has increased and resonant frequency has changed according to various resistor loads. Output current has decreased inversely proportional to changing of loads. Moreover, the measured values of output voltage and current are well agreed with the simulated values of the proposed equivalent circuit model.

  • PDF

염료 감응형 태양전지에서 수분의 함량에 따른 셀의 전기 화학적 특성 연구 (The Study on the Cell Electrochemical Properties with Increasing Water content in Dye-Sensitized Solar cells)

  • 서현우;김동민
    • 한국수소및신에너지학회논문집
    • /
    • 제25권3호
    • /
    • pp.289-296
    • /
    • 2014
  • Here, we have studied the effect of water added electrolyte on the photovoltaic performance of dye-sensitized solar cells (DSSCs). It was found that open-circuit voltage ($V_{oc}$) increased and short-circuit current density ($j_{sc}$) decreased with the increase of the amount of added water in the electrolyte of the DSSCs. Electrochemical impedance spectroscopy (EIS) study showed that the electrolyte with added water shifted the dye loaded $TiO_2$ conduction band upward that eventually increased $V_{oc}$ of the cells. On the other hand, the upward shift of $TiO_2$ conduction band decreased the driving force for the electron injection from the lowest unoccupied molecular orbital (LUMO) of the dye molecules to the conduction band of $TiO_2$ that resulted in decreased $j_{sc}$.

MEA 제조 방법에 따른 직접 메탄올 연료전지의 성능저하 현상 평가 (Effect of MEA fabrication on the performance degradation of DMFC)

  • 조윤환;조용훈;박현서;원호연;성영은
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.60-67
    • /
    • 2007
  • Catalyst coated membrane [CCM] type and catalyst coated substrate [CCS] type of membrane electrode assembly [MEA] were manufactured and evaluated their performance. Degradation test were conducted to find the difference of long term stability in two types of MEA and the factor for performance degradation problem occurred. Performance degradation test of single cell in two different types of MEA were carried out when current density was $200mA/cm^{2}$. The degradation test had proceeded for 230 hours and performance degradation was checked by I-V curve and impedance measurement at regular intervals. Also, MEA before/after operation and changes of catalyst layer were characterized by SEM, TEM, and XRD. Maximum power density of CCM type was higher than that of CCS type. Meanwhile, an increase of particle size of catalyst and an increase of impedance resistance after long term operation were observed. In the case of using CCM type MEA, the performance was deteriorated 38% of initial performance. In the case of using CCS type MEA, the performance was deteriorated 43% of initial performance. In consideration of difference of initial performance, performance of CCM type is higher than that of CCS type but both types had similar problems during degradation test.

  • PDF

대형 스플리터 소음기 성능에 대한 3차원 수치해석적 연구 (Three-dimensional Numerical Study on Acoustic Performance of Large Splitter Silencers)

  • 백성현;이창헌;권대훈;이일재
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.139-147
    • /
    • 2017
  • Acoustic performance of splitter silencers was investigated by using 3-dimensional commercial software and experiments. Flow resistivity of sound absorbing material was indirectly estimated by using an impedance tube setup and a curve fitting method. In addition the acoustic impedance of perforated plate was determined by an empirical formulation. Such properties have been used as input parameters in the commercial software. The prediction for a splitter silencer with 1000 mm length was compared with the experimental result. The numerical method is then applied to identify the effects of number of splitters, length of splitters, absorptive material density, and porosity of a perforated plate on the performance of the splitter silencers. As the number and length of splitter increases, the acoustic performance significantly increases. Although the increase of density of absorptive material also increase the acoustic performance, a change in the density over a certain level hardly affect it. The increase of porosity will enhance the performance especially at higher frequencies.

Design Analysis of Step-down Multilayer Piezoelectric Transformer

  • Hoonbum Shin;Hyungkeun Ahn;Han, Deuk-Young
    • Journal of Power Electronics
    • /
    • 제3권2호
    • /
    • pp.139-144
    • /
    • 2003
  • In this paper, 11 and 13 layered step-down piezoelectric transformers were fabricated and their electrical characteristics have been analyzed for AC-adapter. When the voltage is applied to the driving piezoelectric vibrator polarized in the longitudinal direction, the output voltage is generated at the generating piezoelectric vibrator polarized in the thickness direction due to the piezoelectric effects. From the piezoelectric direct and converse effects, symbolic expressions between the electric inputs and outputs of the step-down piezoelectric transformer are derived with an equivalent circuit model. With those expressions, load and frequency characteristics are discussed through the simulations. Output voltage and current from a 11-layered and a 13-layered piezoelectric transformers were measured under the different load and frequency conditions. First we measured resonant frequency from impedance curve and got equivalent impedance value of the piezoelectric transformer from admittance plot. It was shown from experiments that output voltage increase s and resonant frequency changes according to the various resistor loads. Output current decreases inversely proportional to the change of loads. Moreover, the measured output voltage and current are well matched with the simulated results obtained from the proposed equivalent circuit model. Furthermore, a new step-down piezoelectric transformer has been suggested to Increase the output power based on a simulation result having a driving piezoelectric vibrator polarized thickness direction.

염료 감응형 태양전지에서 시간의 경과에 따른 셀의 특성 저하 연구 (Time Dependent Degradation of Cell in Dye-Sensitized Solar Cell)

  • 서현우;김기수;백현덕;김동민
    • 한국수소및신에너지학회논문집
    • /
    • 제24권5호
    • /
    • pp.421-427
    • /
    • 2013
  • We report on the time dependent degradation of cell in dye-sensitized solar cells (DSSC). The photovoltaic performance of DSSC over a period of time was investigated in liquid electrolyte based on triiodide/iodide during six days. It was found that the short circuit current density ($j_{sc}$) of the cell dropped from 9.9 to $7mA/cm^2$ while efficiency (${\eta}$) of the cell decreased from 4.4 to 3.3%. The parameters corresponding to fundamental electronic and ionic processes in a working DSSC are determined from the electrochemical impedance spectrascopy (EIS) at open-circuit potential ($V_{oc}$). EIS study of the DSSC in the this work showed that the electron life time ${\tau}_r$ and chemical capacitance $C_{\mu}$ decreased significantly after six days. It was correlated the $j_{sc}$ and efficiency decreased after six days.