• 제목/요약/키워드: Impact vibration

검색결과 1,462건 처리시간 0.025초

성인 보행에 따른 충격력 특성에 관한 연구 (Impact Power Characteristics by Walking for Adults)

  • 김경우;최현중;최경석;강재식;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.800-803
    • /
    • 2005
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. Running and jumping impact sound by child and walking by adult are one of the most irritating noises in an apartment buildings. It's necessary to know that the impact power characteristics of real impact source in an apartment buildings. This study aims to investigate the impact power and impact time of normal walking and fast walking for 62 adults. It is shown that when the weight of the person increase, the maximum impact power increases. The impact power waveform for the adults walking varies for subjects walking types. The normal walking impact power lower than that of fast walking and impact time is higher than that of fast walking. The range of the impact power generated by adults walking is less than 1000 N.

  • PDF

주택성능등급제도내 바닥충격음 개선방안 연구 (A Study on Improvement of Floor Impact Noise Section in the Housing Performance Grading Indication System)

  • 고종철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.593-594
    • /
    • 2008
  • The purpose of this study is to review and to suggest improvement concerning floor impact noise section of the housing performance grading indication system. After a result, the main improvement is to resolve the discrepancies in the rules or regulations such as design specification(standard floor system) or design performance(accredited floor system) and as-built performance like 58 dB.

  • PDF

바닥충격음 예측법에 관한 연구 (A study on the method for calculation the floor impact sound)

  • 이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.184-190
    • /
    • 2003
  • In this study, several methods for measuring floor impact sound were introduced. Among them, the simple methods (impedance method and diffuse index method) which can be easily applied to site works were investigated. Moreover, the comparison between the calculation results using diffuse index method and the experimental results measured in real apartment structures was conducted. Consequently, the modified diffuse index method, which can be practically used for predicting the performance of to the floor impact sound of apartment structures and can meet the allowable tolerance of Grade I (${\pm}$5㏈), was proposed.

  • PDF

수진 거리에 따른 방진구의 진동 저감 연구 (A Study on the Vibration Reduction of Borehole by the Receive Distance)

  • 송정언;김승곤;홍웅기
    • 환경영향평가
    • /
    • 제23권3호
    • /
    • pp.169-176
    • /
    • 2014
  • The purpose of this study is to estimate the vibration reduction effect of the borehole which is controlled the vibration propagation in the ground. For this study, we measured the vibration velocity before and after the borehole installation. The results are as follows: The peak particle velocity(PPV) and peak vector sum(PVS) was reduced by the borehole. And also, the deviation of vibration velocity before and after the borehole installation showed large values in longitudinal and vertical component depending on the receive distance, and increased depending on the size of vibration energy. Finally, the vibration isolation efficiency was 25~35 percentage at 1.5m receive distance, and was 4~14 percentage at 3.0m receive distance. It was found that the vibration isolation efficiency was good in small vibration energy, but was not good at long receive distance.

Dynamics of an elastic beam and a jumping oscillator moving in the longitudinal direction of the beam

  • Baeza, Luis;Ouyang, Huajiang
    • Structural Engineering and Mechanics
    • /
    • 제30권3호
    • /
    • pp.369-382
    • /
    • 2008
  • An oscillator of two lumped masses linked through a vertical spring moves forward in the horizontal direction, initially at a certain height, over a horizontal Euler beam and descends on it due to its own weight. Vibration of the beam and the oscillator is excited at the onset of the ensuing impact. The impact produced by the descending oscillator is assumed to be either perfectly elastic or perfectly plastic. If the impact is perfectly elastic, the oscillator bounces off and hits the beam a number of times as it moves forward in the longitudinal direction of the beam, exchanging its dynamics with that of the beam. If the impact is perfectly plastic, the oscillator (initially) sticks to the beam after its first impact and then may separate and reattach to the beam as it moves along the beam. Further events of separation and reattachment may follow. This interesting and seemingly simple dynamic problem actually displays rather complicated dynamic behaviour and has never been studied in the past. It is found through simulated numerical examples that multiple events of separation and impact can take place for both perfectly elastic impact and perfectly plastic impact (though more of these in the case of perfectly elastic impact) and the dynamic response of the oscillator and the beam looks noisy when there is an event of impact because impact excites higher-frequency components. For the perfectly plastic impact, the oscillator can experience multiple events of consecutive separation from the beam and subsequent reattachment to it.

실충격음과 표준충격원으로 발생된 바닥충격음의 비교 (Selection of the standard impact sounds similar to the human impact sounds in reinforced concrete floors)

  • 사토신이치;이평직;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1167-1172
    • /
    • 2007
  • This study investigates human floor impact sounds; not only the children's jumping and running represented by heavy-weight impact source such as bang machine and impact ball but also the high-heel walking and the light weight object dropping represented by tapping machine in the standard measurements. However, due to reliability problems as a standard impactor, bang machine has not been included in the new draft of ISO 10140 Part 3: Measurement of impact sound insulation. Therefore, the procedure to convert the floor impact sound level of the bang machine into that of the impact ball has been demanded because the bang machine has been only the standard heavy-weight standard impact source and much of its data has been collected, This study indicates that the use of impact ball is reliable and that the bang machine data can be successfully converted into the impact ball data in case of box-frame type reinforced concrete structures.

  • PDF

임팩트 볼에 의한 중량충격음 측정에 있어서 수음실 음장특성의 영향 (Effects of the sound field characteristics of the receiving room on heavy-weight impact sound measurement generated by impact ball)

  • 유승엽;이신영;정영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.622-625
    • /
    • 2006
  • This study is a fundamental investigation for standardization of the heavy-weight floor impact measuring method by the impact ball. The distribution chrematistics of floor impact sound level and reverberation time in a receiving room of the testing building for floor impact sound were measured with variations of number and arrangement of the sound-absorbing materials. Total 8 cases were investigated. The distribution of the floor impact sound level($L_{i,\;Fmax}$) was measured at 30 points with same intervals. The absorption coefficient of the room is 0.10 in case of installation of 6 absorbing materials and 0.02 in case of non-installation. The distribution shape of the impact sound pressure level was similar to the result of the bang machine driving at the measured frequency range. However, the overall reduction of the impact sound level investigated in the 125 to 500 Hz shows that the sound absorption characteristics of the receiving room actually affects the result of the heavy-weight impact measurement.

  • PDF

발파해체시 낙하충격진동 예측에 관한 연구 (A Study for Felling Impact Vibration Prediction from Blasting Demolition)

  • 임대규;임영기
    • 화약ㆍ발파
    • /
    • 제22권3호
    • /
    • pp.43-55
    • /
    • 2004
  • 최근 들어 타워형 구조물의 사용 연한이 초과함에 따라 구조물 안전 진단 결과에 따라 철거 작업 혹은 국부적인 성능개선 공사론 수행하고 있다. 그러나 철거 작업시 가능한 한 휴지기간(Shut down)을 단축하여야 한다는 측면 및 경제성 측면에서 발파해체공법은 매우 매력적인 철거수단으로 관심이 증대되고 있으나, 철거시 발생되는 진동으로 인해 인접한 정밀 기기류에 대한 영향을 우려하여 철거 기간과 비용측면에서 상대적으로 불리한 기계식 철거공법을 선호하고 있다. 따라서, 본 연구는 연돌과 같은 타워형 구조물의 발파해체시 붕괴된 부재가 지면과 충돌시 발생되는 지반진동 수준을 예측하는 기법과 진동을 저감할 수 있는 각종 방법에 대한 효과를 축소모형시험을 통해 도출하였다.

주파수 응답함수를 이용한 콘크리트 슬래브 가속도 및 바닥충격소음 예측 (Prediction of Concrete Slab Acceleration and Floor Impact Noise Using Frequency Response Function)

  • 문대호;박홍근;황재승
    • 한국소음진동공학회논문집
    • /
    • 제24권6호
    • /
    • pp.483-492
    • /
    • 2014
  • Uncomfortable feelings of occupants by indoor floor impact noise in a residential building are not accurately represented by the floor impact noise from a standard impact source. It is due to the characteristics of standard impact sources, which are different from the impact forces produced by occupants. It varies significantly by impact source, and it is not easy to be replicated for testing. As a result, the indoor floor impact noise under different acoustic conditions cannot be directly compared. Using frequency response function(FRF), which represents the input-output relationships of a dynamic system, it is possible to examine the characteristics of the system. Especially, FRF can predict the response of a linear dynamic system subjected to various excitation. To determine the relationship between impact force and the corresponding response of dynamic system in residential building, the acceleration response of a concrete slab and the floor impact noise in the living room, produced by bang-machine and rubber-ball excitation, were measured. The test results are compared to the estimates based on FRF and impact force spectrum.

완충재 종류에 따른 중량바닥충격음 저감특성 평가 (A Study on the Heavy-weight Floor Impact Sound Reduction Evaluation of Characteristics by Resilient Materials)

  • 김경우;양관섭;정진연;임정빈;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1145-1148
    • /
    • 2007
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material, which has the most to do with the floor impact sound reduction. The resilient materials available in Korea include EPS (Styrofoam), recycled urethane types, EVA (Ethylene Vinylacetate) foam rubber, foam PE (Polyethylene), glass fiber & rock wool, recycled tire, foam polypropylene, compressed polyester, and other synthetic materials. In this study, we tested floor impact sound reduction characteristic to a lot of kinds of resilient material. The result of test showed that the amount of the heavy-weight impact sound reduction appeared by being influenced from this dynamic stiffness of resilient material. The dynamic stiffness looked like between other resilient materials, a similar to the amount of the heavy-weight impact sound reduction was shown.

  • PDF