• 제목/요약/키워드: Impact resistance

검색결과 1,037건 처리시간 0.039초

Impact resistance of polypropylene fiber reinforced concrete two-way slabs

  • Al-Rousan, Rajai Z.;Alhassan, Mohammed A.;Al-Salman, Harith
    • Structural Engineering and Mechanics
    • /
    • 제62권3호
    • /
    • pp.373-380
    • /
    • 2017
  • Concrete structures are often subjected to long-term static and short-term dynamic loads. Due to a relatively low tensile strength and energy dissipating characteristics, the impact resistance of concrete is considered poor. This study investigates the feasibility of using polypropylene fibers to improve the impact resistance of reinforced concrete slabs. Fourteen polypropylene fiber reinforced concrete slabs were fabricated and tested using a drop weight test. The effects of slab thickness, fiber volume fractions, and impact energy on the dynamic behaviors were evaluated mainly in terms of impact resistant, crack patterns, and failure modes. The post impact induced strains versus time responses were obtained for all slabs. The results showed that adding the polypropylene fiber at a dosage of 0.90% by volume of concrete leads to significant improvement in the overall structural behavior of the slabs and their resistance to impact loading. Interestingly, the enhancement in the behavior of the slabs using a higher fiber dosage of 1.2% was not as good as achieved with 0.90%.

Evaluation of Impact Resistance of Steel Fiber and Organic Fiber Reinforced Concrete and Mortar

  • Kim, Gyu-Yong;Hwang, Heon-Kyu;Nam, Jeong-Soo;Kim, Hong-Seop;Park, Jong-Ho;Kim, Jeong-Jin
    • 한국건축시공학회지
    • /
    • 제12권4호
    • /
    • pp.377-385
    • /
    • 2012
  • In this study, the Impact resistance of steel fiber and organic fiber reinforced concrete and mortar was evaluated and the improvement in toughness resulting from an increase in compressive strength and mixing fiber for impact resistance on performance was examined. The types of fiber were steel fiber, PP and PVA, and these were mixed in at 0.1, 0.5 and 1.0 vol.%, respectively. Impact resistance is evaluated with an apparatus for testing impact resistance performance by high-speed projectile crash by gas-pressure. For the experimental conditions, Specimen size was $100{\times}100{\times}20$, 30mm ($width{\times}height{\times}thickness$). Projectile diameter was 7 and 10 mm and impact speed is 350m/s. After impact test, destruction grade, penetration depth, spalling thickness and crater area were evaluated. Through this evaluation, it was found that as compressive strength is increased, penetration is suppressed. In addition, as the mixing ratio of fiber is increased, the spalling thickness and crater area are suppressed. Organic fibers have lower density than the steel fiber, and population number per unit area is bigger. As a result, the improvement of impact resistance is more significant thanks to dispersion and degraded attachment performance.

교각의 선박충돌 설계강도 (Design Strength of Bridge Piers against Ship Collision)

  • 이성로;배용귀
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.659-662
    • /
    • 2004
  • An analysis of the AF is performed for each bridge pier exposed to ship collision. From this analysis, the impact lateral resistance can be determined for each pier. The bridge pier impact resistance is selected using a probability-based analysis procedure in which the predicted AF, from the ship collision risk assessment is compared to an acceptance criterion. In this study, the acceptance criterion is allocated to each pier using allocation weights based on the previous predictions. To determine the design impact lateral resistance of bridge components such pylon and pier, the numerical analysis is performed iteratively with the analysis variable of impact resistance ratio of pylon to pier. The design impact lateral resistance can vary greatly among the components of the same bridge, depending upon the waterway geometry, available water depth, bridge geometry, and vessel traffic characteristics.

  • PDF

압축강도 및 비상체의 크기에 따른 고강도 콘크리트의 내충격 성능평가 (Evaluation of Impact Resistance Performance of High Strength Concrete by Projectile Size and Compressive Strength)

  • 김홍섭;김규용;미야우치 히로유키;남정수;전영석;구경모
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.7-10
    • /
    • 2011
  • In this study, evaluation system of impact resistance performance is proposed. Compressive strength of concrete is 40, 60 and 80MPa. It evaluate impact resistance performance to use projectile 6, 7 and 8mm size. As a result, safety performance is more higher when the compressive strength is increased in. Compared with Hughes's formula, evaluation system of impact resistance performance is appropriated.

  • PDF

섬유혼입율 변화에 따른 HPFRCC의 내충격 특성 (Impact Resistance Characteristics of HPFRCC Depending on Various Fiber Replacing Ratio)

  • 박용준;김대건;문경식;한상휴;김규용;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.75-76
    • /
    • 2015
  • This study has examined the impact resistance and blast resistance characteristics of HPFRCC as a research on impact resistance and blast resistance characteristics using high volume mortar and high velocity projectile for evaluating the protection performance of actual buildings as small quantity experiment of laboratory conditions is performed although there was an instance of performing research on mortar that has reinforced fiber followed by the rise of problems on the damage of human life and buildings created due to explosion and shock. As a result, the destruction loss area and depth have decreased in case of the surface compared to the rear side. As tensile strength and tenacity have increased with the increased fiber replacing ratio, a tendency of destruction loss area and depth getting decreased was shown as the impact resistance has increased.

  • PDF

반복충격을 받은 UHPC의 내충격성능 평가 (Evaluation of Impact resistance of UHPC Under Repeated Impact)

  • 정민승;김규용;이상규;황의철;김경태;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.161-162
    • /
    • 2018
  • In this study, it evaluate the impact resistance of UHPC by repeated impact. smooth steel fiber and polyvinyl alcohol fiber were reinforced in UHPC respectively. Overall, the impact resistance of the specimens reinforced with 0.4vol.% PVA fiber was high, and the crater diameter was small in specimens using 13mm fiber. When 19 mm steel fiber is used, the fracture depth is small due to the increase of macro crack resistance compared with other specimens. On the other hand, in the case of the fracture area, it is considered that the use of the fiber of 13 mm causes an increase in the stress dispersion effect to occur small.

  • PDF

석고보드 벽체의 시공높이에 따른 수평하중저항성 및 내충격성 변동 특성 (Variation Characteristics of Stiffness and Impact Resistance under Conastruction Height of Gypsum Board Wall)

  • 송정현;김기준;안홍진;신윤호;지석원;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.184-185
    • /
    • 2014
  • The purpose of this study is to experimentally evaluate the variation characteristics of stiffness and impact resistance under the construction height of gypsum board wall at the actual construction site. The method suggested in previous study was applied on the test method of horizontal load resistance and impact resistance. As a result of horizontal load resistance test, when the wall height is 2,400 mm, the maximum displacement is 13.6 mm and residual deformation is 0.5 mm, and when the wall height is 3,000 mm, the maximum displacement is 31.3 mm and the residual displacement is 6.8 mm. As a result of impact resistance test, the residual deformation of each specimen at 20 cm of fall height were 1.02 mm and 0.08 mm, respectively, the residual deformation at 40 cm of fall height were 1.58 mm and 0.35 mm, respectively, and the residual deformation at 60 cm of fall height were 2.23 mm and 2.48 mm, respectively.

  • PDF

질화유리의 고속충돌 저항물성 (A Resistance Property Against High Velocity Impact on Oxynitride Glasses)

  • 김창욱;이형복
    • 한국세라믹학회지
    • /
    • 제43권10호
    • /
    • pp.646-652
    • /
    • 2006
  • Several oxynitride glasses were fabricated by means of adding $Si_3N_4$ powders as nitrogen source to Ca-Al-Si-O-N (CAS) and Mg-Al-Si-O-N (MAS) glass powders, and heat-treated in graphite crucible at 1600$^{\circ}C$ for 1 h. The physical and mechanical properties as well as impact resistance were generally increased and compared with each other. The impact resistance properties of those manufactured glasses were evaluated by DOP (depth of penetration) method which is a way to analyze armor materials. There were two means to be used herein; the copper jet impacted at hyper velocity by exploding K2l5 warhead and tungsten heavy alloy (WHA) impact bar at high velocity by firing in 30 mm solid propellent gun. The impact resistance properties against copper jet were increased and then decreased with increasing nitrogen content, while those against WHA bar were not changed apparently with nitrogen content.

Safety Evaluation of Fire Resistant Extruded Panel for Partition Wall System

  • Choi, Duck-Jin;Kim, Jin-Man
    • 한국건축시공학회지
    • /
    • 제12권6호
    • /
    • pp.586-595
    • /
    • 2012
  • While the extruded cement panel has many advantages compared to drywall, it has limited applicability in buildings due to its low fire resistance. However, an extruded panel in which the fire resistance has been dramatically enhanced through the addition of a-hemihydrate gypsum is expected to become widely applied as a partition wall or interior material for buildings. To ensure its applicability, certain safety requirements for use, such as the leaning load by residents, the impact by indoor articles, and the fire, need to be taken into consideration. The purpose of this study is to review the impact load resistance, horizontal load resistance, and fire resistance as required safety properties for the partition wall and interior materials of the extruded panel that includes a-hemihydrate gypsum. The results of this study show that the impact load resistance of the extruded panel that includes a-hemihydrate gypsum achieves SD grade for industrial buildings, and the horizontal impact load resistance achieves HD grade for public buildings. In addition, it provides fire-resistance for approximately 7 minutes longer than the existing extruded cement panel. Based on this result, it is confirmed the extruded panel incorporating a-hemihydrate gypsum has adequate safety properties for use as partition wall or interior material.

ALC 블록 벽체에 시공한 석재 아트월의 내충격성 평가 (Evaluation of Impact Resistance of Interior Stone Walls Constructed on the ALC Block Wall)

  • 고봉천;이덕주;김현;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2019
  • Interior stone walls are using commonly in non-bearing lightweight walls of apartments. The stones of interior wall were two types, one is a granite stone, another is a marble stone. Granite stone is attached by the epoxy adhesive and marble stone is attached by dedicated anchor and fastener. The impact resistance test was carried out interior stone walls in accordance with KS F 2613. The test methods included the impact resistance tests by each of soft impact body and hard impact body. The results of the test have proved that interior stone walls can withstand the soft impact bodies and hard impact bodies that are likely to happen in everyday life.

  • PDF