• Title/Summary/Keyword: Impact Safety

Search Result 2,652, Processing Time 0.031 seconds

A Theoretical Study on the Compressibility Factor of Hydrogen Gas in the High Pressure Tank (고압탱크에서 수소가스의 압축성 인자에 관한 이론적 연구)

  • JI-QIANG LI;HENG XU;JI-CHAO LI;JEONG-TAE KWON
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.2
    • /
    • pp.162-168
    • /
    • 2023
  • The fast refueling process of compressed hydrogen has an important impact on the filling efficiency and safety. With the development and use of hydrogen energy, the demand for precision measurement of filling hydrogen thermodynamic parameters is also increasing. In this paper, the compressibility factor calculation model of high-pressure hydrogen gas was studied, and the basic equation of state and thermo-physical parameters were calculated. The hydrogen density data provided by the National Institute of Standards and Technology was compared with the calculation results of each model. Results show that at a pressure of 0.1-100 MPa and a temperature of 233-363 K, the calculation accuracy of the Zheng-Li equation of state was less than 0.5%. In the range of 0.1-70 MPa, the accuracy of Redich-Kwong equation is less than 3%. The hydrogen pressure more influences on the compressibility factor than the hydrogen temperature does. Using the Zheng-Li equation of state to calculate the compressibility factor of on-board high pressure hydrogen can obtain high accuracy.

Synergistic bond properties of new steel fibers with rounded-end from carbon nanotubes reinforced ultra-high performance concrete matrix

  • Nguyen Dinh Trung;Dinh Tran Ngoc Huy;Dmitry Olegovich Bokov;Maria Jade Catalan Opulencia;Fahad Alsaikhan;Irfan Ahmad;Guljakhan Karlibaeva
    • Advances in nano research
    • /
    • v.14 no.4
    • /
    • pp.363-373
    • /
    • 2023
  • A novel type of steel fiber with a rounded-end shape is presented to improve the bonding behavior of fibers with Carbon Nanotubes (CNT)-reinforced Ultra-High Performance Concrete (UHPC) matrix. For this purpose, by performing a parametric study and using the nonlinear finite element method, the impact of geometric characteristics of the fiber end on its bonding behavior with UHPC has been studied. The cohesive zone model investigates the interface between the fibers and the cement matrix. The mechanical properties of the cohesive zone model are determined by calibrating the finite element results and the experimental fiber pull-out test. Also, the results are evaluated with the straight steel fibers outcomes. Using the novel presented fibers, the bond strength has significantly improved compared to the straight steel fibers. The new proposed fibers increase bond strength by 1.1 times for the same diameter of fibers. By creating fillet at the contact area between the rounded end and the fiber, bond strength is significantly improved, the maximum fiber capacity is reachable, and the pull-out occurs in the form of fracture and tearing of the fibers, which is the most desirable bonding mode for fibers. This also improves the energy absorbed by the fibers and is 4.4 times more than the corresponding straight fibers.

Comparative Assessment of Quality Changes in Refrigerated Foods Stored in Open-type and Door-type Refrigerators: Towards Developing Quality Indicators (냉장 중 품질변화 측정 지표 개발을 위한 냉장고 형태별(개방형 및 도어형) 저장 중 주요 냉장 식품의 품질변화 측정)

  • A-Ra Jang;Hyunji Song;Hyunwoo Joung;Euijin Choo;Sun-Young Lee
    • Journal of the FoodService Safety
    • /
    • v.4 no.1
    • /
    • pp.7-20
    • /
    • 2023
  • This study was conducted to investigate the impact of refrigerator type and temperature fluctuations on the quality changes of refrigerated foods. Phycochemical and sensory quality, as well as microbial growth, were measured for various foods stored in open- or door-type refrigerators set at 5℃ during storage. The average temperatures recorded were 11.50±1.14℃ in an open refrigerator, and 6.34±0.97℃ in a closed refrigerator. The average surface temperatures of the food items were 9.60±1.20 and 6.00±0.80℃ for open and closed refrigerators, respectively. Significant changes in color and appearance quality were observed in lettuce, mackerel, ground beef, and cut pineapples when stored in open refrigerators. Ready-to-Eat foods such as gimbap and sandwiches exhibited higher levels of microbiological proliferation when stored in open refrigerators compared to closed refrigerators. Processed foods, such as sterilized milk and packaged tofu, did not show significant differences in quality among various types of refrigerators. The installation of refrigerator doors can effectively minimize temperature fluctuations caused by external factors, thereby reducing variations in food quality. These findings provide essential insights into the quality changes associated with the implementation of refrigerator doors, serving as fundamental data for ensuring optimal food preservation.

Insight from sirtuins interactome: topological prominence and multifaceted roles of SIRT1 in modulating immunity, aging, and cancer

  • Nur Diyana Zulkifli;Nurulisa Zulkifle
    • Genomics & Informatics
    • /
    • v.21 no.2
    • /
    • pp.23.1-23.9
    • /
    • 2023
  • The mammalian sirtuin family, consisting of SIRT1-SIRT7, plays a vital role in various biological processes, including cancer, diabetes, neurodegeneration, cardiovascular disease, cellular metabolism, and cellular homeostasis maintenance. Due to their involvement in these biological processes, modulating sirtuin activity seems promising to impact immuneand aging-related diseases, as well as cancer pathways. However, more understanding is required regarding the safety and efficacy of sirtuin-targeted therapies due to the complex regulatory mechanisms that govern their activity, particularly in the context of multiple targets. In this study, the interaction landscape of the sirtuin family was analyzed using a systems biology approach. A sirtuin protein-protein interaction network was built using the Cytoscape platform and analyzed using the NetworkAnalyzer and stringApp plugins. The result revealed the sirtuin family's association with numerous proteins that play diverse roles, suggesting a complex interplay between sirtuins and other proteins. Based on network topological and functional analysis, SIRT1 was identified as the most prominent among sirtuin family members, demonstrating that 25 of its protein partners are involved in cancer, 22 in innate immune response, and 29 in aging, with some being linked to a combination of two or more pathways. This study lays the foundation for the development of novel therapies that can target sirtuins with precision and efficacy. By illustrating the various interactions among the proteins in the sirtuin family, we have revealed the multifaceted roles of SIRT1 and provided a framework for their possible roles to be precisely understood, manipulated, and translated into therapeutics in the future.

Customer satisfaction and skin care shop selection factors in the pandemic era impact on revisit intention (팬데믹 시대의 피부관리숍 선택요인이 고객만족도와 재방문 의도에 미치는 영향)

  • Byoung Ock Lee;Soo Nam Hong
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.25 no.2
    • /
    • pp.83-95
    • /
    • 2023
  • The purpose of this study was to identify the effect of skin care salons' decision factors on customer satisfaction and revisit intention during the COVID-19 pandemic. The subjects of this study were 220 women in their 20s to 50s who reside in Seoul and the Gyeonggi-do area and are users of skin care salons. The data was statistically analyzed using SPSS V.25.0 and detailed research results are as follows. For the analysis of this study, frequency analysis, factor analysis, reliability verification, independent sample T-Test, one-way analysis of variance, post hoc test, Duncan test, and regression analysis were conducted. First, as a result of examining whether skin care salon decision factors during the pandemic have a positive (+) effect on customer satisfaction, hygienic environment satisfaction and service environment satisfaction, which are sub-factors of customer satisfaction, had a significant effect on professionalism, kind service, and distance, which are sub-factors of decision factors, and are independent variables. Second, as a result of examining whether skin care salon decision factors during the pandemic have a positive (+) effect on revisit intention, decision factors, which are independent variables, including professionalism, kind service, price, and distance showed significant effects on human revisit intention, As for physical revisiting intention, only kind service, distance, and professionalism showed significant effects, while price did not have a significant effect. Third, as a result of examining whether customer satisfaction during the pandemic has a positive (+) effect on revisiting intention, the service environment satisfaction and hygienic environment satisfaction, which were sub-factors of independent variables, showed significant results for human and physical revisit intentions. In this study, service environment and hygienic environment satisfaction were important variables for skin care salon decision factors. Professionalism and kind service were important for human revisit intention. Therefore, overall service environment, hygiene, and safety should be prioritized to increase revisit intention and efforts must be made to retain and improve customer satisfaction

Vulnerabilities and Attack Methods in Visible Light Communications Channel (가시광 통신 채널의 취약성 및 공격 방법)

  • Park, So-Hyun;Joo, Soyoung;Lee, Il-Gu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.469-471
    • /
    • 2021
  • As wireless communication technology advances to ensure high accuracy and safety at high speeds, research and development of Visible Light Communication (VLC) technology has been accelerated as an alternative to traditional radio frequency (RF) technology. As the radio spectrum of RF communication becomes more congested and demand for bandwidth continues to increase, VLCs that can use unlicensed frequency band are proposed as a solution. However, VLC channels have broadcasting characteristics that make them easily exposed to eavesdropping and jamming attacks, and are vulnerable to MITM (Man-In-The-Middle) due to their line of sight (LOS) propagation characteristics. These attacks on VLC channels compromise the confidentiality, integrity, and availability of communications links and data, resulting in higher data retransmission rates, reducing throughput and increasing power consumption, resulting in lower data transmission efficiency. In this work, we model vulnerable VLC channels to analyze the impact of attacks and communications vulnerabilities by malicious jammers.

  • PDF

Activity concentrations and radiological hazard assessments of 226Ra, 232Th, 40K, and 137Cs in soil samples obtained from the Dongnam Institute of Radiological & Medical Science, Korea

  • Jieun Lee;HyoJin Kim;Yong Uk Kye; Dong Yeon Lee;Wol Soon Jo;Chang Geun Lee;Jeung Kee Kim;Jeong-Hwa Baek;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2388-2394
    • /
    • 2023
  • The radioactivity concentration of environmental radionuclides was analyzed for soil and sand at eight locations within a radius of 255 m centered on the Dongnam Institute of Radiological & Medical Science (DIRAMS), Korea. The average activity concentrations of 40K, 137Cs, 226Ra, and 232Th were 661.1 Bq/kg-dry, 0.9 Bq/kg-dry, 21.9 Bq/kg-dry, and 11.1 Bq/kg-dry, respectively. The activity of 40K and 137Cs was lower than the 3-year (2017-2019) average reported by the Korea Institute of Nuclear Safety, respectively. Due to the nature of granite-rich soil, the radioactivity of 40K was 0.6-fold higher than in other countries, while 137Cs was in the normal fluctuation range (15-30 Bq/kg-dry) of the concentration of radioactive fallout from nuclear tests. The activity of 226Ra and 232Th was lower than in Korean soils reported by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). The average activity concentrations of 232Th and 40K for the soil and sand samples from DIRAMS were within the range specified by UNSCEAR in 2000. The radium equivalent activity and internal and external hazard index values were below the recommended limits (1 mSv/y). These radionuclide concentration (226Ra, 232Th, 40K, and 137Cs) data can be used for regional environmental monitoring and ecological impact assessments of nuclear power plant accidents.

Analysis of Potential Construction Risk Types in Formal Documents Using Text Mining (텍스트 마이닝을 통한 건설공사 공문 잠재적 리스크 유형 분석)

  • Eom, Sae Ho;Cha, Gichun;Park, Sun Kyu;Park, Seunghee;Park, Jongho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.91-98
    • /
    • 2023
  • Since risks occurring in construction projects can have a significant impact on schedules and costs, there have been many studies on this topic. However, risk analysis is often limited to only certain construction situations,and experience-dependent decision-making is therefore mainly performed. Data-based analyses have only been partially applied to safety and contract documents. Therefore, in this study, cluster analysis and a Word2Vec algorithm were applied to formal documents that contain important elements for contractors or clients. An initial classification of document content into six types was performed through cluster analysis, and 157 occurrence types were subdivided through application of the Word2Vec algorithm. The derived terms were re-classified into five categories and reviewed as to whether the terms could develop into potential construction risk factors. Identifying potential construction risk factors will be helpful as basic data for process management in the construction industry.

An Adaptive Tuned Heave Plate (ATHP) for suppressing heave motion of floating platforms

  • Ruisheng Ma;Kaiming Bi;Haoran Zuo
    • Smart Structures and Systems
    • /
    • v.31 no.3
    • /
    • pp.283-299
    • /
    • 2023
  • Structural stability of floating platforms has long since been a crucial issue in the field of marine engineering. Excessive motions would not only deteriorate the operating conditions but also seriously impact the safety, service life, and production efficiency. In recent decades, several control devices have been proposed to reduce unwanted motions, and an attractive one is the tuned heave plate (THP). However, the THP system may reduce or even lose its effectiveness when it is mistuned due to the shift of dominant wave frequency. In the present study, a novel adaptive tuned heave plate (ATHP) is proposed based on inerter by adjusting its inertance, which allows to overcome the limitation of the conventional THP and realize adaptations to the dominant wave frequencies in real time. Specifically, the analytical model of a representative semisubmersible platform (SSP) equipped with an ATHP is created, and the equations of motion are formulated accordingly. Two optimization strategies (i.e., J1 and J2 optimizations) are developed to determine the optimum design parameters of ATHP. The control effectiveness of the optimized ATHP is then examined in the frequency domain by comparing to those without control and controlled by the conventional THP. Moreover, parametric analyses are systematically performed to evaluate the influences of the pre-specified frequency ratio, damping ratio, heave plate sizes, peak periods and wave heights on the performance of ATHP. Furthermore, a Simulink model is also developed to examine the control performance of ATHP in the time domain. It is demonstrated that the proposed ATHP could adaptively adjust the optimum inertance-to-mass ratio by tracking the dominant wave frequencies in real time, and the proposed system shows better control performance than the conventional THP.

Exposure Characteristics of Indoor Air Pollutants in Some Local Pubic Buses (IoT 기반 시내버스 실내공기질 노출 특성)

  • Kim, Ho-Hyun
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.1
    • /
    • pp.44-51
    • /
    • 2022
  • Background: Air pollution is increasing together with industrialization and urbanization. In order to reduce air pollution, public transportation is recommended rather than private cars, and the number of passengers using public transportation is increasing accordingly. This study observes the concentration of indoor pollutants in city buses over time. Through this means, we intend to suggest a plan to manage the indoor air quality in city buses. Objectives: The concentration of indoor pollution in public transportation was investigated from April 2021 to January 2022. Based on this, we evaluated the exposure to indoor pollutants. Methods: Six city bus lines in an industrial city were selected for the research, and indoor pollution was measured through IoT (Internet of Things)-based sensor-type measuring devices. The concentration of pollutants was measured every minute, and statistical data were constructed based on the measurement results. Results: In all the city buses studied, the average concentration of pollutants were below the guidelines. However, some measurement results showed cases of exceeding the guidelines. As a result of the analysis by time zone, there were more cases in which pollutants exceeded the standard value during rush hour compared to at other times. A risk assessment for PM10 was performed by evaluating the excess mortality risk from exposure and the risk from inhalation exposure. Conclusions: All measured indoor pollutants in the city buses did not exceed the guidelines. Also, the risk assessment results were found to be within the level of safety. However, if a city bus is used for a long time, there is a possibility that there may be an impact on the human body due to inhalation exposure, so additional management is required.